A study of improved MHR 50/100 toward a higher level of inherent safety

A new concept of the Mitsubishi small-sized High temperature gas-cooled modular Reactors (MHR-50/100) had been developed and published in papers. The study results of the first design concept show that the MHR-50/100 can achieve the inherent safety level set as a design target in case of water ingress during steam generator tube rupture accident. And more specifically, the reactor was shown to remain stable during long-term station black out (SBO) with protection of only passive devices during a depressurization accident and with additional motion of steam dump system during a water ingress accident. Recently greater requirements for safety of future nuclear plants including the MHR-50/100 have been expected. This study has thus made a key design improvement for the MHR-50/100 in order to secure the inherent safety aspect without reliance on active steam dump system in case of a water ingress accident. The innovative technologies listed below have been created and investigated to achieve the improved MHR-50/100 design; (1) Design improvement of steam generator, (2) Heat balance optimization of steam cycle, (3) Control system design of differential pressure between primary helium gas and water/steam, (4) Study on operation procedure during a water ingress accident. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrity assessment of the ferritic / austenitic dissimilar weld joint between intermediate heat exchanger and steam generator in fast reactor

Integrity of the modified 9Cr-1Mo / alloy 800 dissimilar joint welded with Inconel 182 electrodes has been assessed under creep condition based on the detailed analysis of microstructure and stress distribution across the joint by finite element analysis. A hardness peak at the ferritic / austenitic weld interface and a hardness trough at the inter-critical heat affected zone (HAZ) in ferritic base metal developed. Un-tempered martensite was found at the ferritic / austenitic weld interface to impart high hardness in it; whereas annealing of martensitic structure of modified 9Cr-1Mo steel by inter-critical heating during welding thermal cycle resulted in hardness tough in the inter-critical HAZ. Creep tests were carried out on the joint and ferritic steel base metal at 823 K over a stress range of 160-320 MPa. The joint possessed lower creep rupture strength than its ferritic steel base metal. Failure of the joint at relatively lower stresses occurred at the ferritic / austenitic weld interface; whereas it occurred at inter-critical region of HAZ at moderate stresses. Cavity nucleation associated with the weld interface particles led to premature failure of the joint. Finite element analysis of stress distribution across the weld joint considering the micro-mechanical strength inhomogeneity across it revealed higher von-Mises and principal stresses at the weld interface. These stresses induced preferential creep cavitation at the weld interface. Role of precipitate in enhancing creep cavitation at the weld interface has been elucidated based on the FE analysis of stress distribution across it. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On-line measurements of RuO{sub 4} during a PWR severe accident

After the Fukushima accident, it became essential to have a way to monitor in real time the evolution of a nuclear reactor during a severe accident, in order to react efficiently and minimize the industrial, ecological and health consequences of the accident. Among gaseous fission products, the tetroxide of ruthenium RuO{sub 4} is of prime importance since it has a significant radiological impact. Ruthenium is a low volatile fission product but in case of the rupture of the vessel lower head by the molten corium, the air entering into the vessel oxidizes Ru into gaseous RuO{sub 4}, which is not trapped by the Filtered Containment Venting Systems. To monitor the presence of RuO{sub 4} allows making a diagnosis of the core degradation and quantifying the release into the atmosphere. To determine the presence of RuO{sub 4}, FTIR spectrometry was selected. To study the feasibility of the monitoring, high-resolution IR measurements were realized at the French synchrotron facility SOLEIL on the infrared beam line AILES. Thereafter, theoretical calculations were done to simulate the FTIR spectrum to describe the specific IR fingerprint of the molecule for each isotope and based on its partial pressure in the air. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fuel cladding post-quench LOCA embrittlement: mechanical test relevance

During a loss-of-coolant-accident (LOCA), the fuel cladding is submitted to a high temperature increase in a steam environment, along with an internal pressure increase which would eventually lead to ballooning and burst of the cladding. Steam could then penetrate through the burst opening and lead to inner surface oxidation and secondary-hydriding of the cladding. Post-quench cladding rupture can then occur either in two-sided oxidized area with wall thinning due to ballooning, or in single-sided oxidized area with large hydrogen content. Common tests involved in the evaluation of the post-quench ductility are Ring Compression Tests (RCT), Expansion Due to Compression Test (EDC) or Axial Tensile Tests (AT). Questions arise about these mechanical tests, as for instance, the influence on sample failure of the oxide layer thickness partitioning between inner and outer diameter. A systematic study was carried out to compare several mechanical tests on both single-sided and two-sided Zircaloy-4 oxidized samples. Five different mechanical tests were compared, including RCT: C-shaped ring Compression Test (CCT), Axial Tensile test (AT), Ring Tensile Test with well-defined machined gage section (RTT) and plain Ring Tensile Test (pRTT). All samples were taken from cladding tubes which had been oxidized in steam at 1200 Celsius degrees and then water-quenched. Mechanical tests were performed at room temperature and two to three samples were tested for each oxidation conditions and for every sample geometry to assess the reproducibility. Metallographic examinations were carried out to measure the ZrO{sub 2} and αZr(O) layer thicknesses and the ex-β/α(O) phase fraction. Mean hydrogen content measurements were also performed systematically on each sample. Results indicate that the different mechanical tests have not the same sensitivity to the oxide layer partitioning: RTT and pRTT load at failure seems to depend mainly on the cumulated oxide layer thickness rather than on its partitioning, whereas this parameter has an impact on CCT and AT test results. For all tensile tests, stresses at failure were derived from load-displacement curves. The failure of brittle samples was assumed to be governed by linear elastic fracture mechanics. Using conventional stress intensity factor solution, a value of the material fracture toughness controlling the sample failure was determined from experimental results and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full core LOCA analysis for BWR/6 - Methodology and first results

As part of collaboration between the Paul Scherrer Institute (PSI) and the Swiss regulator ENSI, a study aimed at core-wide estimates of the fuel rod behaviour during large-break loss-of-coolant-accidents (LB-LOCA) in BWR/6 plants was recently conducted on the basis of a Swiss reactor. To perform such full core LOCA analysis, a methodology consisting of a multi-physics sequence of interfaced best-estimate models and codes was established: CASMO-4E/SIMULATE-3 (C4/S3) for the core modelling, TRACE for the plant system analysis and FALCON for the fuel thermomechanical calculations during base irradiation (BI) as well as for the transient analyses (TA). As starting point, reference C4/S3 models validated for all operated cycles of the given plant were used to select as situation target, a recent cycle representative of modern BWR core loadings and fuel assembly designs. Based on the selected C4/S3 cycle model, PSI in-house computational modules were developed or updated in order to set up the TRACE full core model with regards to assembly geometries, fuel rods thermophysical properties and initial 3-D power distributions. Also, an interface to FALCON BI models was established for the transfer of the irradiation history, including primarily linear heat generation rates (LHGR), for an equivalent fuel pin. For each assembly, the power of the equivalent pin is defined with the maximum power of all pins at each axial position. However, in order to reduce the computational time of the fuel performance analyses, the whole core was subdivided into groups of assemblies, each represented by the most powerful assembly within the group. On this basis, the FALCON BI analyses were conducted with coupling to the PSI advanced model for gas release and swelling (GRWS-A) and an interface was developed to transfer the calculated fuel rod characteristics at end of irradiation to initialize the core fuel rods heat structures in the TRACE model. Subsequently, double-ended recirculation line rupture scenarios at hot-full-power (HFP) conditions were investigated with TRACE in order to determine a conservative transient case as function of cycle burnup, single failure criterion and availability of safety systems. For the most conservative case of this study, an interface was set-up to transfer the TRACE results as boundary conditions to the FALCON TA models, including thus primarily time and axial distributions of the clad outer temperatures. As final step, the FALCON TA were conducted for the representative assemblies in order to infer core-wide estimates of the fuel rod behaviour with specific focus on equivalent cladding reacted levels, hoop strains as well as margins to failure criteria. The objective of this paper is to present this methodology along with the obtained first results. Regarding the latter, it is found that principally, even for the most conservative LOCA scenario of this study, the clad temperature excursion remains mild enough at all core locations such that no significant rod ballooning and no cladding failure is predicted, something in line with corresponding analyses conducted earlier for BWR/4 plants. (authors)

42 ENGINEERING↗

Development of surface modified Zr cladding by coating technology for ATF

It is expected that the accident tolerance fuels (ATF) will provide an enhanced fuel performance of active cooling in the reactor core for a longer time period during design-basis events as well as maintain or improve the fuel performance during normal operations and operational transients. Thus, various ATF cladding concepts have being suggested and developed in many countries. Among them, the coated cladding concept is studied in this work after the considerations of various performances in both the accidents and normal operation of LWRs. In the surface coated cladding concepts, the combination of coating material and coating method is a very important factor to determine the ATF cladding performance. As a new coating material, Cr-based alloy was developed to increase the corrosion resistance under normal operation as well as the oxidation resistance during an accident. From the high temperature oxidation test at 1200 Celsius degrees, the Cr-based alloy showed a superior oxidation resistance to Zircaloy-4 cladding, and showed more improved corrosion resistance than Zircaloy-4 cladding under 360 Celsius degrees PWR simulated loop conditions. The 3D laser coating and a combination of arc ion plating and laser beam scanning were developed to obtain a good adhesion property of corrosion resistance alloy coated on a Zr substrate. The corrosion resistance alloy (Cr-based alloy and FeCrAl alloy) coated layer used by two types of coating methods was maintained without peeling off during the ring compression test at room temperature, although some cracks were formed on the coated layer. After a high-temperature oxidation test at 1200 Celsius degrees for 2000 s, a very thin oxide layer, which was a few microns, was formed on the corrosion resistance alloy layer. However, the ZrO{sub 2} phase, which was thicker than 100 μm was formed on the Zr alloy cladding surface. Thus, it is known that the high-temperature oxidation resistance of commercial Zr alloy cladding can be considerably improved by the coating of corrosion resistant alloys. In addition, the partial oxide dispersion strengthened (ODS) treatment using a laser beam scanning (LBS) method was applied to decrease the ballooning and rupture opening during accident conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental validation on the operational and cooling performance of the passive safety system with Atlas

After the Fukushima accident, passive safety systems are considered as the most promising alternatives to reinforce the safety and reliability of an ultimate heat removal system without any operator actions. In Korea, a passive auxiliary feedwater system (PAFS) was developed and adopted to a GEN-III+ nuclear power plant, APR+ to completely replace the conventional auxiliary feedwater system. The integral effect tests were performed to validate the cooling and operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. The representative design basis accidents (DBAs) such as a feedwater line break, a steam line break, and a steam generator tube rupture transients were experimentally simulated in this study. In addition, an integral effect test was performed for simulating a station blackout transient as a limiting beyond DBA. From the integral effect test results, it could be concluded that the APR+ has the capability of coping with the hypothetical DBA and bDBA by adopting PAFS and proper set-points of its operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

APR1400 In-Core Instrumentation Penetration Failure by Zirconia Melt

Light water reactors have many penetrations at the reactor vessel lower head which are called ICI (in-core instrumentation tubes), ICM-GT (in-core monitoring guide tubes), CRGT (control rod guide tubes) and drain tubes. For Korean PWRs (pressurized water reactors), there are dozens of bottom-up type ICI penetration tubes (45 for OPR1000 and 61 for APR1400). For the typical BWRs (boiling water reactors), hundreds of penetrations are positioned at the reactor vessel lower head due to the structural complexity at the reactor upper head. These penetrations are regarded as the most vulnerable structures during a severe accident as they could be failed by high temperature of melt (or debris) and its decay heat. That is, tube rupture and/or tube ejection could occur because there exist an empty hole inside the penetration tube which can be a melt flow path, and they are attached to the inside of the reactor vessel by a partial weld with a gap between the tubes and reactor vessel. Therefore, the research on the penetration failure is of importance, as it could lead to melt discharge into the containment and subsequent release of radioactive materials to the environment due to the containment failure. This paper focuses on the experimental investigation on the tube ejection failure for the APR1400 ICI penetration. The tube ejection experiments were performed as it was exposed to high temperature of zirconia melt and high pressure. The tube ejection failure experiments were performed for the APR1400 in-core instrumentation penetration nozzle. Zirconia melt was used as a simulant of molten corium and interacted with the penetration specimen. The specimen was pressurized up to 2.6 bar during the interaction with melt to induce the tube ejection. The penetration weld was heated up to its melting temperature, and the penetration tube and weld above the reactor vessel surface were eroded severely by the melt. However, even though it was estimated that the weld failure occurred and the reactor vessel with stainless steel cladding was ablated severely by the melt, the tube ejection did not take place, and consequently the integrity for the APR1400 ICI penetration was confirmed in the present experimental conditions. The goal of this research is to improve the penetrations failure models in MAAP5 codes based on the experimental data. To achieve this goal, it is necessary to increase the heat flux and pressure acting on the penetration tube to find the conditions for the tube ejection failure. Moreover, the penetration failure experiments will be performed by delivering melt into the penetration specimen to simulate the melt relocation process in a real severe accident situation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Estimation of LOCA break size using cascaded support vector regression - 334

A failure of emergency core cooling system (ECCS) during a certain small break loss of coolant accident (SBLOCA) can cause a severe core uncovery and fuel failure. The safety injection systems (SISs) might not function properly in case of a SBLOCA, due to the slight change of pressure in the pipes. Early trend of the major parameters has to be observed and the accurate information has to be given to the nuclear power plant (NPP) operators by precisely identifying the break size to effectively manage accidents. In this study, the objective is to provide to operators the information on the break size in a short time by considering the accident situations such as hot-leg LOCA, cold-leg LOCA, steam generator tube rupture (SGTR). A cascaded support vector regression (CSVR) is used in order to estimate the break size. The simulation data set was obtained from the optimized power plant reactor 1000 (OPR1000) using modular accident analysis program (MAAP) code. And genetic algorithm (GA) was used to select the input variables of the CSVR model and optimize its parameters. As a result of this study, the CSVR model estimate very well the break size of LOCAs. If the operators can predict the break size in the LOCA, they can response quickly and properly to LOCA circumstances to prevent the core uncovery and fuel failure. Also, it will be possible to more efficiently manage beyond design basis accidents. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characteristics Analysis of SGTR accidents under the Shutdown Conditions

The Steam Generator Tube Rupture (SGTR) accident is one of design basis accidents that could result in undesirable radiation release as it bypasses the containment. According to Ref. [1], SGTRs have been experienced in several nuclear power plants and Ulchin 4 of Korea is one of them. Basically, SGTR analysis assumes that it occurs at full power, the SGTR at Ulchin 4 in 2002, was in the shutdown condition. Therefore, the transient behavior was different from the cases in full power conditions and especially, the effectiveness of Emergency Operating Procedure (EOP) needs to be checked if it is also applicable to the shutdown conditions, because EOP is prepared for full power conditions. In this paper, we set up a MARS-KS code model for Ulchin 4 unit and simulated the SGTR accident for benchmarking the model to the actual plant behavior during the accident. And then, several case studies were done to investigate the consequence of SGTR and the effectiveness of the EOP, focusing on the amount of the primary to secondary discharge flow which was influenced by operator actions. At the end, we'll discuss about the EOP for the shutdown conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Proposed Correlation for Critical Flow Rate of Steam/Water Flow

In the safety analysis of loss-of-coolant-accident (LOCA) and steam generator tube rupture (SGTR) scenarios of light water reactors, a modeling of a break is very important to predict the accident's result. For example, the design of a break simulator to simulate a LOCA in light water reactors requires accurate knowledge of the leakage flow through the break, whose shape can be assumed as an orifice or a nozzle according to the characteristics of the break shape. In the case of a small-break LOCA (SBLOCA) scenario, the critical flow mostly occurs by sub-cooled and saturated liquid water including a two-phase water flow at relatively high-pressure conditions. Among previous critical flow maps, Moody's maps are well known for their critical flow rate and pressure of a single component and two-phase mixture with respect to the upstream enthalpy and pressure. In Moody's model, a slip ratio defined by maximizing the critical flow rate with respect to the slip ratio was introduced, and thus its predictions tended to be too conservative. Later, Moody suggested other maps based on a homogeneous equilibrium model (HEM), and they were useful to predict a choked condition for a given upstream condition. However, their predictions of the critical flow rate seemed to show quite an underestimation compared to various test data. The author suggested more practicable critical flow maps for a critical mass flux and pressure of a steam-water flow with respect to the upstream stagnation conditions using an extended Henry-Fauske model. From a comparison with the selected test data, suggested maps showed conservative predictions within reasonable ranges. In this report, a new correlation for the critical flow rate was developed to simulate the suggested critical flow maps within a reasonable range of error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulations of a Helical Tube Bundle in Cross-Flow for Application to Flow-Induced Vibration

Helical tubes have been used in a number of systems, including the energy and chemical processing industries. Helical-Coil Steam Generators (HCSGs) in particular have special application in systems for which spatial constraints are important. Variants of these designs are notably included in a number of integral-vessel small modular reactor (SMR) designs which are currently in development by multiple companies. These designs typically have the primary side located within the vessel, with the secondary side flowing upward through the helical tubes. One complexity in implementing an HCSG within the reactor pressure vessel is that any potential flow-induced vibration (FIV) can impact reactor safety. In a typical power plant, heat exchanger tube failures caused by FIV can be costly, but generally do not have immediate impact on the core safety due to their relative isolation from the core area. In an integral-vessel design, a tube rupture could eject material from the secondary side into the primary flow, potentially damaging the core itself or other crucial components. Thus a higher degree of confidence in predicting and/or preventing FIV should be attained for implementing the helical tubes in these designs. A significant campaign is currently underway to address the topic of FIV in helical tube arrays. The U.S. Department of Energy, under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) initiative, has deemed this a 'high-impact problem'. This will include both experimental and computational contributions from a consortium consisting of multiple universities, industry partners, and national laboratories, including Argonne National Laboratory. The primary industrial partner is NuScale, which will see direct benefits from this initiative to the development of their SMR and its component design. The primary focus of this paper is to establish some of the computational efforts that have been made to this stage and the initial benchmarking of computational tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of TDLAS for Water Vapor Concentration Measurement during VHTR Steam Ingress

Very-high-temperature reactors (VHTR) utilize a graphite-moderated, helium-cooled design that provides higher efficiencies and a low-carbon source of process heat (>700 deg. C) for many industrial applications. Safety concerns have led to extensive accident condition investigations. Steam generator heat-exchanger tube rupture accidents (SGTR) can lead to increased reactor core steam density, which causes neutron slowing-down and chemical corrosion of the graphite fuel elements and structural columns. It is important to be able to computationally model the propagation of steam throughout the lower plenum and nuclear reactor core, but experimental data is needed to validate such models. The primary objective of this project is to instrument a scaled down experiment of a VHTR designed by Ohio State University (OSU), with tunable diode laser absorption spectroscopy (TDLAS) diagnostics to measure steam concentration changes and map how water vapor propagates through the test facility's lower plenum and core. The basic principle of absorption spectroscopy is based on a molecular species ability to absorb photons of specific energies. A collimated laser beam of known energy is passed through a test section containing a sample gas. When a transition of the absorbing gas species resonates with the laser frequency, a certain amount of energy will be absorbed based on the rovibrational characteristics of the molecule. The intensity of the transmitted laser light can be measured by a detector after exiting the test section. The Beer-Lambert Law of absorbance is used to recover this information relating beam attenuation to the system dimensions, gas composition, pressure, and temperature. The line-strength is a function of temperature alone and relates the fraction of molecules in a given rovibrational state through the partition function. The partition function describes the statistical properties of a system in thermodynamic equilibrium where the states obey a Boltzmann distribution. Thus, the number density of molecules in a particular state can be determined from the total internal partition function at a particular temperature. The lineshape function of a given absorption transition is derived from the physical interaction between the absorbing species and is dependent on temperature and pressure. Random thermal motion of absorbing molecules result in broadening of the linewidth, called Doppler broadening, which follows a Gaussian distribution. Molecular collisions result in broadening and shifting of the linewidth, called pressure broadening, which follows a Lorentzian distribution. The overall lineshape results in a Voigt profile, which is a convolution of the Gaussian and Lorentzian distributions. The Voigt profile does not have a simple analytical form and is most often calculated numerically or approximated by complex functions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pressure Drop-Flow Rate Curves for Single Phase Steam in Steam Generator U-tubes During Severe Accidents

Thermally induced steam generator tube rupture (TI-SGTR) can occur in pressurized water reactors (PWRs) with U-tube steam generators (SGs) during high pressure severe accident sequences resulting in containment bypass. Robust natural circulation patterns including in-vessel natural circulation and countercurrent flow to and from the SGs of superheated steam and other hot gases heats cooler structures in the reactor coolant system (RCS). The buoyancy driven flows return cooler and denser gases back to the core slowing the progression of some core degradation phenomena and failure of the lower head. As much as 50 percent of the decay energy and energy produced from core degradation oxidation reactions can be transported from the core to SGs resulting in the heat up and thermal creep of RCS pressure boundary components including hot leg nozzles, pressurizer surge line, and the SG tubes, many of which contain flaws. The creep failure of an individual tube is dependent on the transitory heating of the tube, a function of the mass flow rate through the tube and local temperature history of steam entering the tube. Buoyancy driven natural circulation flow rates are determined by changes in gravitational head, a combination of changes in fluid density due to heat transfer and change in elevation, and irreversible pressure drops resulting primarily from friction loss in the flow paths and other form losses. The nonuniform flow distribution in U-tubes of varying lengths and heights during single-phase liquid and two-phase natural circulation has been extensively studied in scaled test facilities and verified numerically in previous works. We hypothesize the countercurrent natural circulation of single-phase superheated steam in U-tube SGs is governed by the same characteristic pressure drop-flow rates curves of single-phase liquid and two-phase natural circulations in U-tubes connected to common plena derived in. Secondly, we propose flow distribution is a function of U-tube geometry - height, length, hydraulic diameter, etc., and the larger SGs of Combustion Engineering (CE) style 2 x 4 PWRs, which are the focus of this study, will show greater nonuniformity in tube by tube flow rates and ratio of forward flowing tubes to reverse flowing tubes. This work derives characteristic pressure drop-flow rate curves for single-phase superheated steam in CE-type SGs during a high pressure station blackout (SBO) sequence with failed auxiliary feedwater (AFW) and dry secondary side which is closely related to the TI-SGTR event. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integral Effect Test of ATLAS Facility on Multiple Failure in a Prolonged Station Blackout

Since the Fukushima accident, the design extension conditions (DECs) in a nuclear power plant (NPP) have attracted more importance with respect to nuclear reactor safety, and a consensus has been developed such that these high-risk multiple failure accidents should be revisited from the viewpoint of a reinforcement of the 'defense in depth' concept. In particular, a station blackout (SBO) is one of the most important DECs because a loss of the heat sink without an appropriate accident measure might lead to a core uncovery, core damage, and ultimately, a core meltdown under high pressure. SBO has been recognized to be one of the risk-contributing sequences when combined with additional failure of components such as a reactor coolant pump (RCP) seal leakage or a steam generator tube rupture (SGTR). The RCP seal failure could occur due to a loss of continuous cooling through the seal during SBO. The SGTR during SBO can be a potentially important risk due to the release of the fission product with bypassing the containment boundary. The objective of this study is to experimentally simulate and analyze a prolonged SBO scenario in a thermal hydraulic integral effect test facility, ATLAS. As test items in OECD-ATLAS project, two tests for the SBO condition were conducted with additional failures, that is, a RCP seal failure (A2.1 test) and a SGTR (A2.2 test). In those tests, both the effect of the additional failure on reactor safety and the natural circulation characteristics during prolonged SBO conditions could be investigated. The present test can provide physical insight into the system response during the prolonged SBO scenario combined with the multiple failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operator Action Time Evaluation of Emergency Water Injection Strategy for Extreme SGTR Accidents

In terms of severe accidents caused by earthquakes or tsunamis that are beyond expectation, a special safety inspection for operating plants, following the Fukushima accident, has been conducted by the government of Korea to verify that nation's nuclear power plants have been adequately designed to respond to extreme accidents. The inspection results show that Korean nuclear power plants in operation have no imminent risk for an expected maximum potential earthquake or coastal flooding based on the up-to-date investigation. However, there is a need to implement long- and short-term safety improvements in order to secure the level of safety for natural beyond-design-basis events. One of the measures to increase the mitigation capability during extreme accidents is installing the injection flow paths to provide emergency cooling water of extemal sources using fire engines to the steam generators (SGs) or reactor cooling system (RCS). An emergency cooling water system consists of a fixed pipe connected from the RCS or SGs to the outside of the containment. A standby valve is installed on the pipe. Following the occurrence of an extreme accident, movable equipment (for example, a fire truck hose) can be connected to the pipe hole at the opening of the isolation valve. The emergency cooling water injection strategy was not taken into account for the steam generator tube rupture (SGTR) accident management strategy of the OPR-1000. Therefore, it is necessary to develop some guidelines or strategies to cope with an extreme SGTR scenarios using the newly installed injection flow paths and fire engines. As long as the fission products released from the core during severe accidents are kept inside the containment, there may be several ways to reduce the radionuclide release into the environment, for example, by using plant safety features. The containment bypass sequences, however, allow the fission products to be released into the environment or directly to the auxiliary building. The SGTR accidents, which are one of the containment bypass sequences, have shown during various probabilistic safety assessments (PSAs) to be contributors to plant risk, mainly because of their potential for causing a release outside containment. This paper is intended to be an investigation of the characteristics of accident progressions and assessments for the mitigative effectiveness of the external cooling water injection strategies during extreme SGTR accidents in a typical OPR-1000 plant. Analyses were performed using a MAAP computer code version 5.03. The MAAP code is a system-level computer code capable of conducting integral analyses of potential severe accident progressions in nuclear power plants, whose main purpose is to support a level 2 PSA or severe accident management strategy developments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved Safety Injection Flow Map Associated with Target RCS Depressurization to Maintain Core Coolability of OPR1000

In Korea, Severe Accident Management Guidance (SAMG) for Optimized Power Reactor (OPR1000) has been developed through the research results related to the WOG SAMG, in which the operation phase shifts from the Emergency Operation Procedure (EOP) to the SAMG when the Core Exit Temperature (CET) reaches 923 K. Among 7 mitigation strategies envisioned, the third management strategy, injecting coolant into Reactor Coolant System (RCS) by depressurizing the RCS is one of the key strategies to fortify the in-vessel retention capability. As an aid to such mitigation strategy, a safety injection (SI) flow map has been developed by Lee et al. for predicting required flow rate associated with target RCS depressurization to recover in-vessel coolability. The mechanistic SI flow map used the CET increase rate and core water level decrease rate obtained from MELCOR code simulation. It should be noted that during the severe accident, the total heat generated is sum of the decay heat and the oxidation heat. Thus, it is necessary to consider additional heat sources by oxidation reaction between cladding, structure, control rod, and hot steam prior to the injection of coolant. It was believed that the SI model estimated required flow rate rather conservatively by considering the expected amount decay heat and the accumulated heat in the core based on the RCS pressure. However, it was confirmed that the SI model developed by Lee et al. could not represent the total heat removal especially since start of oxidation. Under transient conditions, the heat sources accumulated in the heat structures (fuel, cladding, supporting structures) should be embarked in the model for accurate contribution of the total heat source to the required flow rate. Therefore, the objective of this study is to improve the previous SI flow map predicting the injection flow rate associated with target RCS depressurization to satisfy the in-vessel coolability during severe accidents. Additional terms were developed to reflect accurate heat accumulating and included in the existing model. Resulting SI flow map includes the target RCS depressurization, which enables discharge of the required flow rate by utilizing the flow rate-pressure curve with operation of two high pressure safety injections (HPSIs). Also recent MELCOR simulation result of a postulated steam generator tube rupture (SGTR) accident verified the accuracy of the improved map.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Efficient fluid-structure interaction simulation of viscoplastic and fracturing thin-shells subjected to underwater shock loading

The fluid-structure interaction simulation of shock-loaded thin-walled structures requires numerical methods that can cope with large deformations as well as local topology changes. We present a robust level-set-based approach that integrates a Lagrangian thin-shell finite element solver with fracture and fragmentation capabilities into an Eulerian Cartesian fluid solver with embedded boundary and mesh adaptation capability. As main computational applications, we consider the plastic deformation and rupture of thin plates subjected to explosion and piston-induced pressure waves in water.

42 ENGINEERING↗