XFEL structures of the influenza M2 proton channel: Room temperature water networks and insights into proton conduction
Room temperature structure of the Influenza A M2 channel wild type transmembrane domain at low pH (pH 5.5)
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Room temperature structure of the Influenza A M2 channel wild type transmembrane domain at low pH (pH 5.5)
Ionic liquids (ILs) are promising pretreatment solvents for lignocellulosic biomass, but are largely prepared from petroleum precursors. Benzaldehydes from depolymerized lignin, such as vanillin, syringaldehyde, and 4-methoxy benzaldehyde, represent renewable feedstocks for the synthesis of ionic liquids. We herein report syntheses of novel lignin-derived ionic liquids, with extended N -alkyl chains, and examine their melting points, cellulose dissolution capacities, and toxicity profiles against Daphnia magna and E. coli strain 1A1. The latter organism has been engineered to produce isoprenol, a drop-in biofuel and precursor for commodity chemicals. The new N,N -diethyl and N,N -dipropyl methyl benzylammonium ILs were liquids at room temperature, showing 75–100 °C decreased melting points as compared to their N,N,N -trimethyl benzylammonium analog. Extension of N -alkyl chains also increased antibacterial activity threefold, while ionic liquids prepared from vanillin showed 2- to 4-fold lower toxicity as compared to those prepared from syringaldehyde and 4-methoxybenzaldehyde. The trend of antibacterial activity for anions of lignin-derived ILs was found to be methanesulfonate < acetate < hydroxide. Microcrystalline cellulose dissolution, from 2 to 4 wt% after 20 min at 100 °C, was observed in all new ILs using light microscopy and IR spectroscopy. Ionic liquids prepared from H-, S- and G-lignin oxidation products provided differential cytotoxic activity against E. coli and D. magna , suggesting these compounds could be tailored for application specificity within a biorefinery.
A ppb-level formaldehyde (H 2 CO) sensor was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) room temperature interband cascade laser (ICL) emitting at 3.59 μm and a miniature dense pattern multipass gas cell with >50 m optical path length. Performance of the sensor was investigated with two measurement schemes: direct absorption (DAS) and wavelength modulation spectroscopy (WMS). With an integration time of less than 1.5 second, a detection limit of ~3 ppbv for H 2 CO measurement with precision of 1.25 ppbv for DAS and 0.58 ppbv for WMS, respectively, was achieved without zero air based background subtraction. An Allan-Werle variance analysis indicated that the precisions can be further improved to 0.26 ppbv @ 300s for DAS and 69 pptv @ 90 s for WMS, respectively. Finally, a side-by-side comparison between two measurement schemes is also discussed in detail.
High-dimensional quantum key distribution (HDQKD) is a promising avenue to address the inherent limitations of basic quantum key distribution (QKD) protocols. However, experimental realizations of HDQKD to date have relied on indeterministic photon sources that limit the achievable key rate. In this paper, we demonstrate a full emulation of a HDQKD system using a single colloidal giant quantum dot (gQD) as a deterministic, compact, and room-temperature single-photon source (SPS). We demonstrate a practical protocol by encoding information in a high-dimensional space (d = 3) of the orbital angular momentum of the photons. Our experimental configuration incorporates two spatial light modulators for encoding and decoding the spatial information carried by individual photons. Our experimental demonstration establishes the feasibility of utilizing high radiative quantum yield gQDs as practical SPSs for HDQKD. We also experimentally demonstrate surpassing the traditional d = 2 QKD capacity with comparable error rates, indicating a significant improvement in performance while maintaining reliability.
Materials were developed and tested in support of the U.S. Department of Energy, Office of Nuclear Energy, Fuel Cycle Technology Separations and Waste Forms Campaign. Specifically, materials are being developed for the removal of Xenon and krypton from gaseous products of nuclear fuel reprocessing unit operations. During FY 2012, Three Metal organic framework (MOF) structures were investigated in greater detail for the removal and storage of Xe and Kr from air at room temperature. Our breakthrough measurements on Nickel based MOF could capture and separate parts per million levels of Xe from Air (40 ppm Kr, 78% N2, 21% O2, 0.9% Ar, 0.03% CO2). Similarly, the selectivity can be changed from Xe > Kr to Xe < Kr simply by changing the temperature in another MOF. Also for the first time we estimated the cost of the metal organic frameworks in bulk.
An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.
Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.
This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.
Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.
This project addresses room-temperature electrochemical etching as an energy-efficient route to synthesis of 3D nanoporous carbon networks and layered 2D carbons and related structures, as well as provides fundamental understanding of structure and properties of materials produced by this method. Carbide-derived-carbons (CDCs) are a growing class of nanostructured carbon materials with properties that are desirable for many applications, such as electrical energy and gas storage. The structure of these functional materials is tunable by the choice of the starting carbide precursor, synthesis method, and process parameters. Moving from high-temperature synthesis of CDCs through vacuum decomposition above 1400°C and chlorination above 400°C, our studies under the previous DOE BES support led to identification of precursor materials and processing conditions for CDC synthesis at temperatures as low as 200°C, resulting in amorphous and highly reactive porous carbons. We also investigated synthesis of monolithic CDC films from carbide films at 250-1200°C. The results of our early studies provided new insights into CDC formation, led to development of materials for capacitive energy storage, and enabled fundamental understanding of the electrolyte ions confinement in nanoporous carbons.
Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.
Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by ratcheting up the 1 star level for fixed and inverter ACs to the level of today’s five star rating for inverter ACs by 2022. Bulk procurement (similar to the Domestic Efficient Lighting Program) and incentive programs can complement the accelerated ratcheting up of star levels. Similar programs can also be implemented for other types of ACs.
Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment
Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficient and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia, the highest-efficiency RAC models employ the low-GWP refrigerants R-32 or R-290. • RACs are available in most regions and worldwide that surpass the highest efficiency levels recognized by labeling programs. • Fixed-speed RACs using high-GWP and ozone-depleting R-22 refrigerant still dominate the market in many emerging economies. There is significant scope to improve RAC efficiency and transition to low-GWP refrigerants using commercially available technology and to design market-transformation programs for high-efficiency, low-GWP equipment including standards, labeling, procurement, and incentive programs.
The U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA), Los Alamos Field Office (NA-LA) proposes to enclose the existing loading dock to create a conference room at building 303, located within Technical Area (TA) 16, Los Alamos National Laboratory (LANL). TA-16-303 has been determined eligible for listing in the National Register of Historic Places in correspondence with the New Mexico State Historic Preservation Division dated June 22, 2003. Eligibility status is based on its historical significance during the Cold War at Los Alamos and its representative architectural style, which is associated with high explosives research and development in support of the nation’s nuclear weapons program. As shown in the enclosed photograph, key architectural elements include a flat roof with overhangs, unpainted reinforced-concrete construction, green painted doors and trim.
Increasing incomes, electrification, and urbanization—as well as a warming world—are driving up the global stock of air conditioners (ACs), particularly in emerging economies with hot climates. AC energy consumption is expected to increase substantially as the global stock of room ACs rises to 1.5 billion in 2030 and 2.5 billion in 2050. Hence, improving AC energy efficiency will be critical to reducing AC energy, cost (consumer lifecycle cost, electricity generation cost, etc.), peak load, and emissions impacts. The 2016 Kigali Amendment to the Montreal Protocol offers an opportunity to improve AC energy efficiency in tandem with the phasedown of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. Based on the most recent information, a literature review, and interviews with manufacturers and industry experts, we find the main barriers to deploying high-efficiency ACs include concerns about market demand and cost, which could be mitigated by appropriately improved design of market-transformation programs such as standards and labeling, incentive, and procurement programs. The main barriers to the low-GWP refrigerant transition include the need for timely revision of safety standards and associated costs for capacity-building activities allowing safe use of low-GWP refrigerants in ACs. Policy action and the market transformation can be accelerated by advancing the refrigerant transition and efficiency improvements in parallel.
The ability to integrate ceramics with other materials has been limited by the high temperature s (>800C) associated with ceramic processing. A novel process, known as aerosol deposition (AD), capable of preparing ceramic films at room temperature (RT) has been the subject of recent interest in the thermal spray and microelectronics communities. In this process, ceramic particles are accelerated using pressurized gas, impacted on a substrate and form a dense film under vacuum. This revolutionary process eliminates high temperature processing, enabling new coatings and microelectronic device integration as a back end of line process, in which ceramics can be deposited on metals, plastics, and glasses . Future impact s of this technology on Sandia's mission could include improved ceramic integration, miniaturized magnetic circulators in radar applications, new RF communication products, modification of commercial - off - the - shelf electronics, fabrication of conformal capacitors, thin batteries, glass - to - metal seals, and transparent electronics. Currently, optimization for RT solid - state deposition of ceramics is achieved empirically and fundamental mechanisms for ceramic particle - particle bonding are not well understood. Obtaining this knowledge will allow process - microstructure - property relation ship realization and will enable a differentiating ceramic integration capability. This LDRD leveraged Sandias existing equipment and capabilities in simulation, experimentation, and materials characterization to discover the fundamental mechanisms for ceramic particle deformation, particle - substrate bonding, and particle - particle bonding in RT consolidated films. RT deformation of individual Al 2 O 3 particles was examined computationally and experimentally as a model system for understanding the complex dynamics associated with in vacuo RT deposition conditions associated with AD. Subsequently, particle - substrate bonding and particle - particle bonding in AD Al 2 O 3 consolidated films were examined computationally and experimentally. Fundamental mechanisms behind the AD process were proposed.
A handout describing the Electronic Public Reading Room at Los Alamos National Laboratory is provided.