Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Second-Harmonic Generation of Subterahertz Gyrotron Radiation by Frequency Doubling in InP:Fe and Its Application for Magnetospectroscopy of Semiconductor Structures

The possibility of obtaining intense terahertz radiation due to second-order lattice nonlinearity in indium-phosphide crystals doped with iron is discussed. As a source of radiation, subterahertz gyrotrons are considered. It is shown that the efficiency of frequency doubling can reach 3%, which opens up the possibility for developing a new generation of terahertz radiation sources. The possibility of applying second-harmonic radiation for the magnetospectroscopy of semiconductor structures with quasi-Dirac dispersion is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear relativistic single-electron Thomson scattering power spectrum for incoming laser of arbitrary intensity

The classical nonlinear incoherent Thomson scattering power spectrum from a single relativistic electron with incoming laser radiation of any intensity, investigated numerically by the present authors in a previous publication, displayed both an approximate quadratic behavior in frequency and a redshift of the power spectrum for high intensity incoming radiation. The present work is devoted to justify, in a more general setup, those numerical findings. Those justifications are reinforced by extending suitably analytical approaches, as developed by other authors. Moreover, our analytical treatment exhibits differences between the Doppler-like frequencies for linear and circular polarization of the incoming radiation. Those differences depend nonlinearly on the laser intensity and on the electron initial velocity and do not appear to have been displayed by previous authors. Those Doppler-like frequencies and their differences are validated by new Monte Carlo computations beyond our previuos ones and reported here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An In-situ and Direct Confirmation of Super-Planckian Thermal Radiation Emitted From a Metallic Photonic-Crystal at Optical Wavelengths

Planck’s law predicts the distribution of radiation energy, color and intensity, emitted from a hot object at thermal equilibrium. The Law also sets the upper limit of radiation intensity, the blackbody limit. Recent experiments reveal that micro-structured tungsten can exhibit significant deviation from the blackbody spectrum. However, whether thermal radiation with weak non-equilibrium pumping can exceed the blackbody limit in the far field remains un-answered experimentally. Here, we compare thermal radiation from a micro-cavity/tungsten photonic crystal (W-PC) and a blackbody, which are both measured from the same sample and also in-situ. We show that thermal radiation can exceed the blackbody limit by >8 times at λ=1.7 μm resonant wavelength in the far-field. Our observation is consistent with a recent calculation by Wang and John performed for a 2D W-PC filament. This finding is attributed to non-equilibrium excitation of localized surface plasmon resonances coupled to nonlinear oscillators and the propagation of the electromagnetic waves through non-linear Bloch waves of the W-PC structure. This discovery could help create super-intense narrow band thermal light sources and even an infrared emitter with a laser-like input-output characteristic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Processes of interaction of laser radiation with porous transparent materials during their ablation

The effect of ytterbium fibre laser radiation with λ = 1.07 μm on the pressed micropowders of transparent oxides and fluorides (CaF{sub 2}, Y{sub 2}O{sub 3}, Al{sub 2}O{sub 3}, YSZ, etc.) having low absorption coefficients is theoretically studied. Using the numerical modelling, it is established that the radiation scattering in the medium of particles 0.5 – 4.6 μm in diameter leads to the concentration of radiation in the local regions of the medium, with the intensity level exceeding the intensity of the incident radiation (0.46 MW cm{sup −2}) by many times. It is shown that with the growth of the refractive index n of the material from 1.38 (MgF{sub 2}) to 2.12 (YSZ) the intensity of radiation in the region of the strongest local maximum increases from 3.8 to 31 MW cm{sup −2}. In our opinion, this factor can be dominant in determining the possibility of achieving the ablation of such a medium by means of the radiation having an intensity of no greater than 1 MW cm{sup −2}. This hypothesis is experimentally checked by the example of preparing a nanopowder of CaF{sub 2} (n = 1.43) and 1 % Nd : Y{sub 2}O{sub 3} (n = 1.91) by evaporating the pressed target with the porosity 50 % by the continuous-wave radiation of the ytterbium fibre laser with the power 600 W and the intensity 0.4 MW cm{sup −2}. Inside the CaF{sub 2} target, the scattered radiation intensity is smaller than the optical breakdown threshold, and the target is not evaporated. Under the same conditions, the target made of higher-melting 1 % Nd : Y{sub 2}O{sub 3} evaporates well, and the efficiency of the nanopowder production amounts to 23 g h{sup −1}. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vector Analysis of Prostate Patient Setup With Image-Guided Radiation Therapy via kV Cone Beam Computed Tomography

Purpose: To analyze the daily setup variations in a cohort of intensity-modulated radiation therapy (IMRT) prostate cancer patients who had received daily image-guided RT without the use of fiducial markers to determine if daily image guidance is necessary. Methods and Materials: 2134 Kilovoltage (kV) cone beam computed tomography (CBCT) images were analyzed, with three shifts recorded for each image. The number of times that the vector of the combined shifts would have exceeded the planning tumor volume (PTV) margin was tallied. Then, the average scalar shift of the first five images was removed from all subsequent images for a given patient, and the number of days for which the shift vector was greater than the three-dimensional clinical tumor volume-PTV (3D CTV-PTV) margin (8 mm, created with rolling ball technique) was recorded. Additionally, the scalar shifts from every other fraction were studied to determine if the individual patient's shift vector would be adequately sampled if CBCT was not performed daily, thus reducing patient imaging dose without compromising treatment quality. Results: There were 297 cases where the vector shift was initially greater than the PTV margin. By correcting each patient's data set by the average shift of their first five images the total was 248 cases. By considering only every other image of each patient data set (after correction for the first 5 days), only 137 days in which the CTV was outside the PTV would have been seen. Conclusions: Daily imaging is recommended for prostate cancer IMRT patients in order to know the 3D (vector) position of the CTV and to ensure that it is always within the PTV margin. Correcting the data set by the average shift from the first 5 days reduces the overall number of outlier days but does not eliminate them completely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Objectively Quantifying Radiation Esophagitis With Novel Computed Tomography–Based Metrics

Purpose: To study radiation-induced esophageal expansion as an objective measure of radiation esophagitis in patients with non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy. Methods and Materials: Eighty-five patients had weekly intra-treatment CT imaging and esophagitis scoring according to Common Terminlogy Criteria for Adverse Events 4.0, (24 Grade 0, 45 Grade 2, and 16 Grade 3). Nineteen esophageal expansion metrics based on mean, maximum, spatial length, and volume of expansion were calculated as voxel-based relative volume change, using the Jacobian determinant from deformable image registration between the planning and weekly CTs. An anatomic variability correction method was validated and applied to these metrics to reduce uncertainty. An analysis of expansion metrics and radiation esophagitis grade was conducted using normal tissue complication probability from univariate logistic regression and Spearman rank for grade 2 and grade 3 esophagitis endpoints, as well as the timing of expansion and esophagitis grade. Metrics' performance in classifying esophagitis was tested with receiver operating characteristic analysis. Results: Expansion increased with esophagitis grade. Thirteen of 19 expansion metrics had receiver operating characteristic area under the curve values >0.80 for both grade 2 and grade 3 esophagitis endpoints, with the highest performance from maximum axial expansion (MaxExp1) and esophageal length with axial expansion ≥30% (LenExp30%) with area under the curve values of 0.93 and 0.91 for grade 2, 0.90 and 0.90 for grade 3 esophagitis, respectively. Conclusions: Esophageal expansion may be a suitable objective measure of esophagitis, particularly maximum axial esophageal expansion and esophageal length with axial expansion ≥30%, with 2.1 Jacobian value and 98.6 mm as the metric value for 50% probability of grade 3 esophagitis. The uncertainty in esophageal Jacobian calculations can be reduced with anatomic correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VMAT vs. 7-Field-IMRT: Assessing the Dosimetric Parameters of Prostate Cancer Treatment with a 292-Patient Sample

We compared normal tissue radiation dose for the treatment of prostate cancer using 2 different radiation therapy delivery methods: volumetric modulated arc therapy (VMAT) vs. fixed-field intensity-modulated radiation therapy (IMRT). Radiotherapy plans for 292 prostate cancer patients treated with VMAT to a total dose of 7740 cGy were analyzed retrospectively. Fixed-angle, 7-field IMRT plans were created using the same computed tomography datasets and contours. Radiation doses to the planning target volume (PTV) and organs at risk (bladder, rectum, penile bulb, and femoral heads) were measured, means were calculated for both treatment methods, and dose-volume comparisons were made with 2-tailed, paired t-tests. The mean dose to the bladder was lower with VMAT at all measured volumes: 5, 10, 15, 25, 35, and 50% (p < 0.05). The mean doses to 5 and 10% of the rectum, the high-dose regions, were lower with VMAT (p < 0.05). The mean dose to 15% of the rectal volume was not significantly different (p = 0.95). VMAT exposed larger rectal volumes (25, 35, and 50%) to more radiation than fixed-field IMRT (p < 0.05). Average mean dose to the penile bulb (p < 0.05) and mean dose to 10% of the femoral heads (p < 0.05) were lower with VMAT. VMAT therapy for prostate cancer has dosimetric advantages for critical structures, notably for high-dose regions compared with fixed-field IMRT, without compromising PTV coverage. This may translate into reduced acute and chronic toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation therapy of synchronous bilateral breast carcinoma (SBBC) using multiple techniques

The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V{sub 95%}, V{sub 105%}, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and V{sub XGy}, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p mean and of approximately 5.7% in V{sub 95%} dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in D{sub mean} and V{sub 95%}. IMRT was the best in terms of conformity index and homogeneity index (p 30Gy and V{sub 40Gy} was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V{sub 5%} and V{sub 10%}, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Terahertz radiation by beating Langmuir waves

An intense terahertz (THz) radiation generated by the beating of two Langmuir waves, which are excited by the forward Raman scattering, is analyzed theoretically. The radiation energy per shot can be as high as 0.1 J, with the duration of 10 ps. Appropriate plasma density and the laser characteristics are examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct measurements by Voyagers 1 and 2 of the polarization of terrestrial kilometric radiation

Measurements of the polarization of intense terrestrial kilometric radiation obtained with planetary radio astronomy experiments on Voyager-1 and 2 during the early portions of each flight show the signals to be predominantly left-hand circularly polarized. Since these emissions were most probably generated above the Northern Hemisphere auroral zone, we conclude that the radiation is emitted primarily in the extraordinary mode.

Kaiser, M. L.↗

4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy

The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy delivery, due to the fact that multiple solutions are admissible for imposing the same intensity map over a moving target in this technique of irradiation. The realization of this type of delivery provides a treatment methodology that delivers treatment plans for moving patient anatomy that are superior to any treatments possible for static patient body anatomy. This paper is devoted to exploring this idea. To this end, a simple, though clinically realistic example is developed and presented that shows modified DMLC leaf motions that deliver a predetermined intensity to a moving target while reducing the dose delivered to organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High expression of Ki-67 acts a poor prognosis indicator in locally advanced nasopharyngeal carcinoma

Nasopharyngeal carcinoma (NPC) is a common head and neck malignancy in Southern China and Southeast Asia compared with Western countries. The standard treatment for NPC is radiotherapy. However, radioresistance remains a serious obstacle to satisfactory treatment, it can cause local recurrence and distant metastases in some patients after treatment by radiation. We retrospectively reviewed 108 NPC patients (7th AJCC Ⅲ-Ⅳa) who have received intensity modulated radiation therapy (IMRT) between August 2008 and January 2012 at Xiangya Hospital of Central South University. Ninety-eight patients with >60% reduction of tumor size after radiation treatment were regarded as radiation sensitive, Ten patients with <40% reduction of tumor size after radiation treatment were regarded as radiation resistant. Using immunohistochemistry, we found that the high expression rate of Ki-67 in radiation resistant and radiation sensitive patients was 80.0% and 42.6%, respectively, and the difference was statistically significant (p = 0.025). The 5-year progress free survival rates in patients with low and high expression of Ki-67 was 70.7% and 48.0%, respectively, and the difference was statistically significant (p = 0.0008). Multivariate Cox regression analysis identified that high expression of Ki-67 was an independent negative prognostic factor in nasopharyngeal carcinoma patients [Hazard ratio (95% CI), 2.098(1.101, 3.996); p = 0.024]. These results demonstrate that high expression of Ki-67 contributes to radiation resistance and acts a poor prognosis indicator in patients with locally advanced nasopharyngeal carcinoma. - Highlights: • Radiation resistance remains a serious obstacle in some locally advanced nasopharyngeal carcinoma patients after treatment by radiation. • The proportion of Ki67 + cells after radiotherapy provided an independent variable of responsiveness to radiotherapy in squamous cell carcinoma of the head and neck. • The expression of Ki67 association with radiation resistance in locally advanced nasopharyngeal carcinoma.

60 APPLIED LIFE SCIENCES↗