Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Qualification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Status of Metallic Structural Materials for Molten Salt Reactors

In the US and around the world, significant interest surrounds development and deployment of nuclear systems using molten salts to transfer heat. Several configurations are being explored, including the use of fluoride salts either as the primary coolant of a reactor with solid fuel or with the fissile material dissolved in the salt. Molten Salt Reactors (MSRs) with fluoride salt typically have a thermal neutron spectrum. There are also fast-spectrum reactors that could use chloride salts to transfer heat. As a result of operation of the Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory during the 1960s, a system with uranium fuel dissolved in a fluoride-salt medium is the most well-established technology. A nickel alloy with about 6%Cr and molybdenum as a solid solution strengthening agent was developed and deployed for all structural applications in this reactor. The alloy was commercialized as Hastelloy N. During these experiments and in post-decommissioning characterization of material behavior, it was determined that the most significant challenges for structural materials are embrittlement, from helium introduced by transmutation of Ni, and corrosion and grain boundary embrittlement from the fission product tellurium. The MSRE had an outlet temperature of approximately 650°C. The mechanical properties of Hastelloy N are not sufficient to support long-term operation of an MSR above this temperature. Qualification of a material for use in the ASME Boiler and Pressure Vessel Code, Section III, “Rules for Construction of Nuclear Facility Components,” Division 5, “High Temperature Reactors,” will facilitate licensing with the Nuclear Regulatory Commission. Hastelloy N has not been qualified for use in nuclear construction, and significant additional characterization would be required for Code qualification. Given that this alloy is susceptible to He embrittlement and has limited high-temperature strength, it is not recommended that Code qualification be pursued. Instead, it is recommended that a systematic development program be initiated to develop new nickel alloys that contain a fine, stable dispersion of intermetallic particles to trap He at the interface between the matrix and particle and with increased solid solution strengthening from addition of refractory elements. Extensive screening of attractive alloy compositions for elevated temperature strength, microstructural stability, weldability, and resistance to He embrittlement (characterized using ion implantation) will lead to an alloy down-selection for commercialization and Code qualification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Assessment of the Viability of Scaled Annular Pellet Fabrication Technologies

The DOE-NE AFC program broadly supports the creation of novel fuel forms including intermetallics, composites, and dopants for high uranium density compounds. While data can be obtained for key performance indicators such as thermal expansion and oxidation resistance in steam, fuel qualification remains a time intensive process. As such, accelerated fuel qualification methods are a recent focus of the program. By first looking at systems with known historical irradiation testing information, like UO 2 , the method of accelerated burnup testing can be validated, followed by use on novel materials with less information available, like silicides and nitrides. The biggest time delay in doing irradiation testing is reaching a “high burnup” fuel, to effectively model how the fuel will behave when it has been fully used. Reaching this point conventionally could take upwards of 30 years. Accelerated burnup would be approaching the threshold of “high burnup”, something on the order or 50GWd/MTU, more quickly, which although achievable in test reactors requires a decade to achieve using current irradiation testing schemes. To achieve this faster rate, the fuel is likely going to be subject to thermal effects commiserate with the increased heat by more fission. In a normal fuel pellet, this increased temperature would operate less efficiently because the thermal diffusivity of the pellet only allows it to transfer heat so quickly, thus causing a high centerline temperature and noticeable stress along the diameter of the pellet. Solutions could include smaller pellets, which would have a greater surface area giving off heat relative to their volume, or “shaped” fuel designs modifying the thermal behavior. The concept that drives the annular pellet design is reduction of the thermal gradient caused from the high “centerline” temperature at the center of a normal pellet to its surface. By removing the center of the pellet, the new centerline will instead be closer to an edge (whether that be the inner or outer edge), allowing cooling to wick away more heat than the traditional design. In an ideal world, the center of the pellet could also have a heat wick running through it allowing heat to be transported away from throughout the pellet. This increase in heat removal would allow the pellet to be subjected to higher energy output, and thus accelerate the burn-up process. UO 2 has been the staple fuel form of nuclear energy for decades, and replacement of this functionally understood material can only be done with sufficient fuel qualification. Increasing the burnup allows us to characterize new fuels with limited to no operational experience behind them, including carbides, nitrides, and silicide’s. Production of the unique geometries detailed herein will allow us to cut qualification times from multi-decadal experiments into the sub-decadal range, vastly increasing the quantity and quality of information available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

V31 Test Report

The V31 containment vessel was procured by the US Army Recovered Chemical Material Directorate (RCMD) as a third - generation EDS containment vessel. It is the fifth EDS vessel to be fabricated under Code Case 2564 of the 2019 ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is twenty-four (24) pounds TNT - equivalent for up to 1092 detonations. This report documents the results of explosive tests that were performed on the vessel at Sandia National Laboratories in Albuquerque, New Mexico to qualify the vessel for field operations use. There were three design basis configurations for qualification testing. Qualification test (1) consisted of a simulated M55 rocket motor and warhead assembly of 24lbs of Composition C-4 (30 lb TNT equivalent). This test was considered the maximum load case, based on modeling and simulation methods performed by Sandia prior to the vessel design phase. Qualification test (2) consisted of a regular, right circular cylinder, unitary charge, located central to the vessel interior of 19.2 lb of Composition C-4 (24 lb TNT equivalent). Qualification test (3) consisted of a 12-pack of regular, right circular cylinders of 2 lb each, distributed evenly inside the vessel (totaling 19.2 lb of C-4, or 24 lb TNT equivalent). All vessel acceptance criteria were met.

42 ENGINEERING↗

V31 Test Report

The V31 containment vessel was procured by the US Army Recovered Chemical Materiel Directorate (RCMD) as a third-generation EDS containment vessel. It is the fifth EDS vessel to be fabricated under Code Case 2564 of the 2019 ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is twenty-four (24) pounds TNT-equivalent for up to 1092 detonations. This report documents the results of explosive tests that were performed on the vessel at Sandia National Laboratories in Albuquerque, New Mexico to qualify the vessel for field operations use. There were three design basis configurations for qualification testing. Qualification test (1) consisted of a simulated M55 rocket motor and warhead assembly of 24lbs of Composition C-4 (30 lb TNT equivalent). This test was considered the maximum load case, based on modeling and simulation methods performed by Sandia prior to the vessel design phase. Qualification test (2) consisted of a regular, right circular cylinder, unitary charge, located central to the vessel interior of 19.2 lb of Composition C-4 (24 lb TNT equivalent). Qualification test (3) consisted of a 12-pack of regular, right circular cylinders of 2 lb each, distributed evenly inside the vessel (totaling 19.2 lb of C-4, or 24 lb TNT equivalent). All vessel acceptance criteria were met .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Phase Consensus Roadmap for Development of Condition-Based Cable Reliability Assurance

The objective of this work was to develop a first phase consensus roadmap for condition-based qualification (CBQ) of electrical cables. With CBQ, qualification of Class 1E electrical cables moves from a time-based approach to a condition-based approach, which is anticipated to be safer in terms of reliability and conservatism, and more cost effective in the long run. However, due to barriers, the CBQ approach has not yet been adopted by U.S. nuclear power plants (NPPs). Based upon a review of current work evaluating CBQ, the limitation of available condition monitoring technology seems to be the largest barrier. The importance of condition monitoring, or more specifically selecting appropriate condition indicators, during CBQ cannot be understated. However, selecting appropriate condition indicators is challenged by techniques that are destructive and only evaluate cable degradation locally. Further, arguably, no one identified condition indicator fully establishes cable condition. Thus, additional work is necessary to evaluate potential condition indicators towards CBQ. In addition to the requirements of IEC/IEEE Std. 60780-323, ideal condition indicators should include a) both destructive and non-destructive approaches, b) both local and global measurements, c) real-time (i.e., online) monitoring that trends with degradation, d) enable correlation with qualified levels of degradation, and e) be established within a repository of condition indicators with applicable materials and/or components and their acceptance criteria. Additional work is needed in development of technology and methodology prior to adoption of CBQ, especially for extending qualified life of installed components. Education and early experience by the industry and regulators will be required for this change in approach as an alternative to re-analysis. A series of workshops that bring together stakeholders to identify and address gaps will be needed. The longstanding cooperative working group of cable researchers from the U.S. Department of Energy, the Electric Power Research Institute, and the Nuclear Regulatory Commission forms a valuable starting point for development of a consensus roadmap to condition-based qualification approach as a viable options for qualification of cable systems in U.S. light water reactors.

42 ENGINEERING↗

Draft ASME Code Case to qualify L-PBF 316H material for Section III, Division 5 applications

This report documents the AMMT program’s development and submission of a draft ASME Code Case to qualify Laser Powder Bed Fusion (L PBF) Type 316H stainless steel for Section III, Divi-sion 5 Class A and SM high temperature nuclear applications. It summarizes the technical basis, the comprehensive high temperature mechanical test database assembled between 2023–2026, and the proposed code language and qualification framework submitted to ASME. The work was co-ordinated across multiple national laboratories and leverages prior ASME efforts to integrate additive manufacturing into the Boiler & Pressure Vessel Code. The body of the report describes the experimental database and analysis supporting the Code Case: tensile, creep, fatigue, creep fatigue, and thermal aging tests collected from multiple additive manufacturing sites, machine types, and powder lots, with material processed by a solution anneal heat treatment. The dataset — including both full size and subsized specimens and tests oriented parallel and perpendicular to build direction — shows limited tensile anisotropy, tensile properties comparable to wrought 316H, creep strength within the scatter of wrought material, but markedly reduced creep ductility above about 650 °C associated with rapid σ phase formation in L PBF microstructures. The draft Code Case itself prescribes a staged qualification model (manufacturing process qualification, component qualification, and per build witness testing), treats L PBF components as equivalent to Type 316 weld metal for design and inspection, and requires mechanical, chemical, and metallographic controls tied to ASTM/ISO 52946. Key acceptance criteria include tensile tests within a 90% prediction interval of the AMMT dataset, a creep fatigue screening test adapted from ASME Section III, Division 5, Subsection HB, HBB 2800 but with the cycle acceptance reduced to 100 for L PBF material, and double volumetric inspection of production components. The report concludes that the present data support treating L PBF 316H as analogous to conventional fusion weld metal for Division 5 design and inspection, while highlighting important caveats: the σ phase driven loss of creep ductility above ~650 °C, preliminary indications of enhanced creep fatigue sensitivity in some lots, and remaining gaps in long term aging and additional cyclic testing. Recommended next actions include completing outstanding cyclic and long duration creep/aging tests on the solution annealed condition, supporting inclusion of the 316H chemistry and heat treatment in ASTM/ISO 52946, and continuing engagement with ASME and NRC during balloting and review to enable industry adoption.

Messner, Mark C. (ORCID:0000000200404385)↗

Mercury CEM Calibration

Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The outputs of mercury generators are compared to one another using a nesting procedure which allows direct comparison of one generator with another and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define generator performance as affected by variables such as pressure, temperature, line voltage, and shipping. WRI is focusing efforts to determine actual generator performance related to the variables defined in the qualification portion of the interim protocol. The protocol will then be further revised by EPA based on what can actually be achieved with the generators. Another focus of the study is to evaluate approaches for field verification of generator performance. Upcoming work includes evaluation of oxidized mercury calibration generators, for which a separate protocol will be prepared by EPA. In addition, the variability of the spectrometers/analyzers under various environmental conditions needs to be defined and understood better. A main objective of the current work is to provide data on the performance and capabilities of elemental mercury generator/calibration systems for the development of realistic NIST traceability protocols for mercury vapor standards for continuous emission CEM calibration. This work is providing a direct contribution to the enablement of continuous emissions monitoring at coal-fired power plants in conformance with the CAMR. EPA Specification 12 states that mercury CEMs must be calibrated with NIST-traceable standards (Federal Register 2005). The initial draft of an elemental mercury generator traceability protocol was circulated by EPA in May 2007 for comment, and an interim protocol was issued in August 2007 (EPA 2007). Initially it was assumed that the calibration and implementation of mercury CEMs would be relatively simple, and implementation would follow the implementation of the Clean Air Interstate Rule (CAIR) SO{sub 2} and NO{sub x} monitoring, and sulfur emissions cap and trade. However, mercury has proven to be significantly more difficult to accurately determine than was originally thought. The purpose of the current phase of this project is to evaluate issues related to the use of dynamic elemental mercury calibrators that are based on mercury vapor headspace above elemental mercury at a particular temperature.

01 COAL, LIGNITE, AND PEAT↗

Electronic delay ignition module for single bridgewire Apollo standard initiator

An engineering model and a qualification model of the EDIM were constructed and tested to Scout flight qualification criteria. The qualification model incorporated design improvements resulting from the engineering model tests. Compatibility with single bridgewire Apollo standard initiator (SBASI) was proven by test firing forty-five (45) SBASI's with worst case voltage and temperature conditions. The EDIM was successfully qualified for Scout flight application with no failures during testing of the qualification unit. Included is a method of implementing the EDIM into Scout vehicle hardware and the ground support equipment necessary to check out the system.

Ward, R. D.↗

Vibration testing of the JE-M-604-4-IUE rocket motor (Thiokol P/N E 28639-03)

The NASA International Ultraviolet Explorer (IUE) rocket motor (TE-M-604-4), a solid fuel, spherical rocket motor, was vibration tested in the Impact, Vibration, and Acceleration (IVA) Test Unit of the von Karman Gas Dynamics Facility (VKF). The objective of the test program was to subject the motor to qualification levels of sinusoidal and random vibration prior to the altitude firing of the motor in the Propulsion Development Test Cell (T-3), Engine Test Facility (ETF), AEDC. The vibration testing consisted of a low level sine survey from 5 to 2,000 Hz, followed by a qualification level sine sweep and qualification level random vibration. A second low level sine survey followed the qualification level testing. This sequence of testing was accomplished in each of three orthogonal axes. No motor problems were observed due to the imposition of these dynamic environments.

Alt, R. E.↗

Intermediate load modules for test and evaluation

Photovoltaic modules were tested for qualification. Tests involved the following: (1) delivery of 20 solar cells for use as reference cells; (2) module documentation and inspection plans specifying the 10 Group I modules; (3) design review of module documentation from Group I modules; (4) revise module documentation to overcome any problems of deficiencies associated with the Group I modules; (5) delivery of 10 Group II modules built to revised specifications; (6) testing of Group II modules to the criteria as outlined in qualification specification. It is found that the solarvolt MSP43E40B satisfies the design criteria of qualification specification for intermediate load modules. Design changes were made in the Group I modules to overcome the deficiencies which allowed Group II modules to pass the qualification tests.

Source record↗

Support for life-cycle product reuse in NASA's SSE

The Software Support Environment (SSE) is a software factory for the production of Space Station Freedom Program operational software. The SSE is to be centrally developed and maintained and used to configure software production facilities in the field. The PRC product TTCQF provides for an automated qualification process and analysis of existing code that can be used for software reuse. The interrogation subsystem permits user queries of the reusable data and components which have been identified by an analyzer and qualified with associated metrics. The concept includes reuse of non-code life-cycle components such as requirements and designs. Possible types of reusable life-cycle components include templates, generics, and as-is items. Qualification of reusable elements requires analysis (separation of candidate components into primitives), qualification (evaluation of primitives for reusability according to reusability criteria) and loading (placing qualified elements into appropriate libraries). There can be different qualifications for different installations, methodologies, applications and components. Identifying reusable software and related components is labor-intensive and is best carried out as an integrated function of an SSE.

Shotton, Charles↗

SMEX-Lite Modular Solar Array Architecture

For the most part, Goddard solar arrays have been custom designs that are unique to each mission. The solar panel design has been frozen prior to issuing an RFP for their procurement. There has typically been 6-9 months between RFP release and contract award, followed by an additional 24 months for performance of the contract. For Small Explorer (SMEX) missions, with three years between mission definition and launch, this has been a significant problem. The SMEX solar panels have been sufficiently small that the contract performance period has been reduced to 12-15 months. The bulk of this time is used up in the final design definition and fabrication of flight solar cell assemblies. Even so, it has been virtually impossible to have the spacecraft design at a level of maturity sufficient to freeze the solar panel geometry and release the RFP in time to avoid schedule problems with integrating the solar panels to the spacecraft. With that in mind, the SMEX-Lite project team developed a modular architecture for the assembly of solar arrays to greatly reduce the cost and schedule associated with the development of a mission- specific solar array. In the modular architecture, solar cells are fabricated onto small substrate panels. This modular panel (approximately 8.5" x 17" in this case) becomes the building block for constructing solar arrays for multiple missions with varying power requirements and geometrical arrangements. The mechanical framework that holds these modules together as a solar array is the only mission-unique design, changing in size and shape as required for each mission. There are several advantages to this approach. First, the typical solar array development cycle requires a mission unique design, procurement, and qualification including a custom qualification panel. With the modular architecture, a single qualification of the SMEX-Lite modules and the associated mechanical framework in a typical configuration provided a qualification by similarity to multiple missions. It then becomes possible to procure solar array modules in advance of mission definition and respond quickly and inexpensively to a selected mission's unique requirements. The solar array modular architecture allows the procurement of solar array modules before the array geometry has been frozen. This reduces the effect of procurement lead-time on the mission integration and test flow by as much as 50%. Second, by spreading the non-recurring costs over multiple missions, the cost per unit area is also reduced. In the case of the SMEX-Lite procurement, this reduction was by about one third of the cost per unit area compared to previous SMEX mission-unique procurements. Third, the modular architecture greatly facilitates the infusion of new solar cell technologies into flight programs as these technologies become available. New solar cell technologies need only be fabricated onto a standard-sized module to be incorporated into the next available mission. The modular solar array can be flown in a mixed configuration with some new and some standard cell technologies. Since each module has its own wiring terminals, the array can be arranged as desired electrically with little impact to cost and schedule. The solar array modular architecture does impose some additional constraints on systems and subsystem engineers. First, they must work with discrete solar array modules rather than size the array to fit exactly within an available envelope. The array area is constrained to an integer multiple of the module area. Second, the modular design is optimized for space radiation and thermal environments not greatly different from a typical SMEX LEO environment. For example, a mission with a highly elliptical orbit (e.g., Polar, SMEX/FAST) would require thicker coverglasses to protect the solar cells from the more intense radiation environment.

Lyons, John↗

Low-Pressure Generator Makes Cleanrooms Cleaner

Scientists at NASA's Kennedy Space Center work in cleanrooms: laboratories with high degrees of cleanliness provided by strict control of particles such as dust, lint, or human skin. They are contaminant-free facilities, where the air is repeatedly filtered, and surfaces are smooth to prevent particles from getting lodged. Technicians working in these environments wear specially designed cleanroom "bunny suits" and booties over their street clothes, as well as gloves and face masks to avoid any contamination that may be imparted from the outside world. Even normal paper is not allowed in cleanrooms, only cleanroom low-particulate paper. These are sensitive environments where precision work, like the production of silicon chips or hard disk drives, is performed. Often in cleanrooms, positive air pressure is used to force particles outside of the isolated area. The air pressure in the Kennedy cleanrooms is monitored using high-accuracy, low-differential pressure transducers that require periodic calibration. Calibration of the transducers is a tricky business. In prior years, the analysis was performed by sending the transducers to the Kennedy Standards Laboratory, where a very expensive cross-floated, labor- intensive, dead-weight test was conducted. In the early 1990s, scientists at Kennedy determined to develop a technique and find equipment to perform qualification testing on new low-differential pressure transducers in an accurate, cost-effective manner onsite, without requiring an environmentally controlled room. They decided to use the highly accurate, cost-effective Setra Model C264 as the test transducer. For qualification testing of the Setra, though, a portable, lower-cost calibrator was needed that could control the differential pressure to a high degree of resolution and transfer the accuracy of the Standards Laboratory testing to the qualification testing. The researchers decided that, to generate the low-differential pressure setpoints needed for qualification testing, very small gas volume changes could be made against the test article, and a corresponding pressure change would be detected by a pressure standard. This allowed the researchers to recreate cleanroom air pressure settings without the use of a cleanroom. Thus was born the low-differential pressure generator. In 1993, a prototype was developed using a pair of PVC tanks, a volume controller, and a 1-pound-per-square-inch pressure standard. By 1995, the prototype was perfected into the unit that is still used today.

Source record↗

Developing Standards to Qualify a Fine Water Mist Fire Extinguisher for Human Spaceflight

NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen systems increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide, so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. Compared to the carbon dioxide based Portable Fire Extinguisher, the flight qualification of Fine Water Mist systems requires special care. Qualification of the CO2 based Portable Fire Extinguisher began with the assumption that any fire on ISS would be extinguished if the air in the fire environment reached a critical concentration of CO2. Qualification of a CO2 based system requires the developers to make assertions and assumptions about vehicle geometry and the ability of the extinguisher to deliver CO2 in different geometric configurations, but the developers did not need to make assertions or assumptions about the size of the fire, the temperature, or the heat generation rate. Fine Water Mist systems extinguish a fire predominantly by removing heat -- so qualification standards must evaluate geometry, but also temperature, heat transfer, and heat generation rate. This paper outlines and describes the methods used to develop standards used to qualify Fine Water Mist systems for a human spaceflight environment.

Graf, John↗

Ruby on Rails Applications

Ruby on Rails is an open source web application framework for the Ruby programming language. The first application I built was a web application to manage and authenticate other applications. One of the main requirements for this application was a single sign-on service. This allowed authentication to be built in one location and be implemented in many different applications. For example, users would be able to login using their existing credentials, and be able to access other NASA applications without authenticating again. The second application I worked on was an internal qualification plan app. Previously, the viewing of employee qualifications was managed through Excel spread sheets. I built a database driven application to streamline the process of managing qualifications. Employees would be able to login securely to view, edit and update their personal qualifications.

Hochstadt, Jake↗

Performance Assessment of Refractory Concrete Used on the Space Shuttle's Launch Pad

The John F. Kennedy Space Center (KSC) maintains several facilities for launching space vehicles. During recent launches it has been observed that the refractory concrete materials that protect the steel-framed flame duct are breaking away from this base structure and are being projected at high velocities. There is significant concern that these projected pieces can strike the launch complex or space vehicle during the launch, jeopardizing the safety of the mission. A qualification program is in place to evaluate the performance of different refractory concretes and data from these tests have been used to assess the performance of the refractory concretes. However, there is significant variation in the test results, possibly making the existing qualification test program unreliable. This paper will evaluate data from past qualification tests, identify potential key performance indicators for the launch complex, and will recommend a new qualification test program that can be used to better qualify refractory concrete.

Trejo, David↗

Wear of Steel and Ti6Al4V Rollers in Vacuum

This investigation was prompted by results of a qualification test of a mechanism to be used for the James Webb Space Telescope. Post-test inspections of the qualification test article revealed some loose wear debris and wear of the steel rollers and the mating Ti6Al4V surfaces. An engineering assessment of the design and observations from the tested qualification unit suggested that roller misalignment was a controlling factor. The wear phenomena were investigated using dedicated laboratory experiments. Tests were done using a vacuum roller rig for a range of roller misalignment angles. The wear in these tests was mainly adhesive wear. The measured wear rates were highly correlated to the misalignment angle. For all tests with some roller misalignment, the steel rollers lost mass while the titanium rollers gained mass indicating strong adhesion of the steel with the titanium alloy. Inspection of the rollers revealed that the adhesive wear was a two-way process as titanium alloy was found on the steel rollers and vice versa. The qualification test unit made use of 440F steel rollers in the annealed condition. Both annealed 440F steel rollers and hardened 440C rollers were tested in the vacuum roller rig to investigate possibility to reduce wear rates and the risk of loose debris formation. The 440F and 440C rollers had differing wear behaviors with significantly lesser wear rates for the 440C. For the test condition of zero roller misalignment, the adhesive wear rates were very low, but still some loose debris was formed

Krantz, Timothy L.↗