Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Wind Monitor

NASA needed a way to make high-resolution measurements of the wind profile before launching Saturn vehicles. The standard smooth-surface weather balloons zigzagged or spiraled as they ascended due to air vortices that shed off the surface at various positions, which made accurate radar-tracking measurement impossible. A Marshall Space Flight Center engineer modified the surface of the balloons with conical dixie cups, which stabilized them. Now produced by Orbital Sciences Corporation, the Jimsphere is the standard device at all U.S. missile/launch vehicle ranges.

Source record↗

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

The Potential for a Ka-band (32 GHz) Worldwide VLBI Network

Ka-band (32 GHz, 9mm) Very Long Baseline Interferometric (VLBI) networking has now begun and has tremendous potential for expansion over the next few years. Ka-band VLBI astrometry from NASA's Deep Space Network has already developed a catalog of 470 observable sources with highly accurate positions. Now, several antennas worldwide are planning or are considering adding Ka-band VLBI capability. Thus, there is now an opportunity to create a worldwide Ka-band network with potential for high resolution imaging and astrometry. With baselines approaching a Giga-lambda, a Ka-band network would be able to probe source structure at the nano-radian (200 as) level ( 100X better than Hubble) and thus gain insight into the astrophysics of the most compact regions of emission in active galactic nuclei. We discuss the advantages of Ka-band, show the known sources and candidates, simulate projected baseline (uv) coverage, and discuss potential radio frequency feeds. The combination of these elements demonstrates the feasibility of a worldwide Ka network within the next few years!

quasar↗

Optical Displacement Sensor (ODS), a LISA's inertial reference sensor candidate.

We propose here an optical displacement sensor (ODS) as a supplemental or backup sensor for the LISA inertial reference sensor concept. This simple ODS consists of a laser diode and a quad-cell photodiode (both commercially available). The inertial mass’ reflective surface directs the laser beam onto the quad-cell photodiode. Changes in the inertial mass’ position and orientation are then extracted from ratios of the differences and sums of the quad-cell photodiode outputs. A simpler proto-type using a 200 microns wide slit has demonstrated a resolution of 10 nm/√Hz at 1 mHz and 1 nm/√Hz above 5 mHz. The electronics noise was 1 nm/√Hz at and above 1 mHz with simple and off the shelf electronics components. Although this ODs’ current performance does not meet the LISA’s system requirement’ of 1 nm/ at 1 mHz, we think that is achievable in the near future

Abramocivi, Alex↗

Deletion of Cdkn1a in Mice Rescues Reduced Osteogenesis in Microgravity and Increases Coupled Osteoclastic Bone Degenerative Activity and Bone Loss

Elevated Cdkn1a/p21 levels in mouse bone during spaceflight have led us to hypothesize that this cell cycle inhibitor could regulate osteogenesis in response to mechanical unloading in microgravity. Cdkn1a interacts with cyclins CDK1/2/4,6 during G1 and S phases, and suppression of its expression by mechanical stretch enhances proliferation and mineralization in osteoblastic cell cultures. To test this hypothesis in a whole-organism model, we used C57BL/J6 WT/Cdkn1a-null mice in the NASA RR-10, 30-day ISS microgravity experiment. To quantify active mineralization in microgravity mice were injected with Calcein seven and two days before euthanasia on-orbit, followed by high-resolution confocal imaging of optically cleared femoral endosteal surfaces. To quantify cortical and cancellous bone parameters we conducted microCT analyses of the femur and tibia. Confocal imaging revealed a population of mineralizing calcein-positive single osteoblasts, and multicellular surfaces of mineralization by osteocytes in lacunae. The Cdkn1a-null genotype shows a greater ratio of early-osteoblasts to late-osteocytes and reduced mineralization versus WT. Additionally, in microgravity WT bones have a large (80%) decrease in active mineralization, but remarkably Cdkn1a deletion fully rescued mineralized surface loss. MicroCT shows trends for moderate spaceflight bone loss in WT femurs, and significant losses in the tibia, while Cdkn1a-null femurs showed much larger significant tissue losses, including 25% thinner trabeculae (p < 0.01),40% thinner cortical bone (p < 0.005), and 10% lower percent cortical bone area (p < 0.05). These results indicate that endogenous bone Cdkn1a plays a key role in mechanosensitive downregulation of osteoprecursor proliferation and promotes osteocytic differentiation. In microgravity however, while Cdkn1a deletion rescues mineralization, bone loss quantified by microCT is greatly increased, likely due to the molecular coupling of osteogenesis and osteoclastogenesis. This molecular mechanism opens the possibility for potential pharmacological approaches to mitigate bone loss in space simultaneously targeting Cdkn1a and osteoclast inhibition.

Eduardo A.C. Almeida↗

Validation of an Erythema-Weighted UV Model Using Broadband Solar Irradiance Measurements From Eleven U.S. Sites: Preprint

Erythema-weighted UV solar irradiance (UV-E) has a potential impact on human health if the recommended maximum exposure times are exceeded. In spite of this, it is not measured at most sites that measure Global Horizontal Irradiance (GHI). However, since UV-E is highly correlated with GHI and total ozone content it can be estimated from this information with sufficient accuracy to assisst in public health recommendations. The Power Model (PM) provides a simple method to estimate the erythema-weighted UV irradiance (UV-E) from measured GHI, total ozone column and air mass. In this work, the performance of the PM method is assessed using high-quality data from 11 sites in the continental U.S. (part of SURFRAD and SOLRAD networks) and total ozone estimates publicly available from the MERRA-2 re-analysis database. A three year period (2021- 2023) at 1-minute frequency is considered. The results (for time aggregations of 5 and 60 minutes) show a high Pearson's correlations (> 0.99), consistently positive mean bias deviations (below 13%) and dispersions in the 8-19% range at all sites. Relative values are expressed in terms of the corresponding measurement mean. The performance indicators remain consistent across time resolutions (5 or 60 minutes), suggesting that the model's performance is robust and not significantly affected by short-term variability (which is captured by GHI). Spatial patterns reveal higher biases and RMSD in northern and eastern locations. These values represent a significant improvement over widely used satellite-based global UV-E estimates and open the possibility of using the PM with satellite-based GHI estimates for operational UV-E mapping over the contiguous U.S. territory.

14 SOLAR ENERGY↗

Detection of defects in atomic-resolution images of materials using cycle analysis

The automated detection of defects in high-angle annular dark-field Z-contrast (HAADF) scanning-transmission-electron microscopy (STEM) images has been a major challenge. Here, we report an approach for the automated detection and categorization of structural defects based on changes in the material’s local atomic geometry. The approach applies geometric graph theory to the already-found positions of atomic-column centers and is capable of detecting and categorizing any defect in thin diperiodic structures (i.e., “2D materials”) and a large subset of defects in thick diperiodic structures (i.e., 3D or bulk-like materials). Despite the somewhat limited applicability of the approach in detecting and categorizing defects in thicker bulk-like materials, it provides potentially informative insights into the presence of defects. The categorization of defects can be used to screen large quantities of data and to provide statistical data about the distribution of defects within a material. This methodology is applicable to atomic column locations extracted from any type of high-resolution image, but here we demonstrate it for HAADF STEM images.

36 MATERIALS SCIENCE↗

High-Resolution Imaging of Unstained Polymer Materials

Electron microscopy has played an important role in polymer characterization. Traditionally, electron diffraction is used to study crystalline polymers while transmission electron microscopy is used to study microphase separation in stained block copolymers and other multiphase systems. We describe developments that eliminate the barrier between these two approaches - it is now possible to image polymer crystals with atomic resolution. The focus of this Review is on high-resolution imaging (30 Å and smaller) of unstained polymers. Recent advances in hardware allow for capturing numerous (as many as 105) low-dose images from an unperturbed specimen; beam damage is a significant barrier to high-resolution electron microscopy of polymers. Machine-learning-based software is then used to sort and average the images to retrieve pristine structural information from a collection of noisy images. Acknowledging the heterogeneity in polymer samples prior to averaging is essential. Molecular conformations in a wide range of amphiphilic block copolymers, polymerized ionic liquids, and conjugated polymers can be gleaned from two-dimensional projections (2D), three-dimensional (3D) tomograms, and four-dimensional (4D) scanning transmission electron microscopy (STEM) data sets where 2D diffraction patterns are taken as a function of position. Some methods such as phase contrast STEM have been used to image closely related materials such as metal-organic frameworks but not polymers. With improvements in hardware and software, such methods may soon be applied to polymers. Our goal is to provide a comprehensive understanding of the strategies toward the high-resolution imaging of radiation sensitive polymer materials at different length scales.

36 MATERIALS SCIENCE↗

Verification Challenges of Dynamic Testing of Space Flight Hardware

The Six Degree-of-Freedom Dynamic Test System (SDTS) is a test facility at the National Aeronautics and Space Administration (NASA) Johnson Space Center in Houston, Texas for performing dynamic verification of space structures and hardware. Some examples of past and current tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility is able to integrate a dynamic simulation of on-orbit spacecraft mating or demating using flight-like mechanical interface hardware. A force moment sensor is utilized for input to the simulation during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents many unique challenges, one particular area of interest is with respect to the use of external measurement systems to ensure accurate feedback of dynamic contact. There are many commercial off-the-shelf (COTS) measurement systems available on the market, and the test facility measurement systems have evolved over time to include two separate COTS systems. The first system incorporates infra-red sensing cameras, while the second system employs a laser interferometer to determine position and orientation data. The specific technical challenges with the measurement systems in a large dynamic environment include changing thermal and humidity levels, operational area and measurement volume, dynamic tracking, and data synchronization. The facility is located in an expansive high-bay area that is occasionally exposed to outside temperature when large retractable doors at each end of the building are opened. The laser interferometer system, in particular, is vulnerable to the environmental changes in the building. The operational area of the test facility itself is sizeable, ranging from seven meters wide and five meters deep to as much as seven meters high. Both facility measurement systems have desirable measurement volumes and the accuracies vary within the respective volumes. In addition, because this is a dynamic facility with a moving test bed, direct line-of-sight may not be available at all times between the measurement sensors and the tracking targets. Finally, the feedback data from the active test bed along with the two external measurement systems must be synchronized to allow for data correlation. To ensure the desired accuracy and resolution of these systems, calibration of the systems must be performed regularly. New innovations in sensor technology itself are periodically incorporated into the facility s overall measurement scheme. In addressing the challenges of the measurement systems, the facility is able to provide essential position and orientation data to verify the dynamic performance of space flight hardware.

Winnitoy, Susan↗

Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small–field animal irradiation studies

To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm 2 , 1 × 1 cm 2 , and 0.5 × 0.5 cm 2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm 2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm 2 field and 4.3 % for the 0.5 × 0.5 cm 2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film’s finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm 2 and the 1 × 1 cm 2 fields and within 1 mm for the larger field of 2 × 2 cm 2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1–4 cm) for the 1 × 1 cm 2 and 2 × 2 cm 2 and within 5% for the 0.5 × 0.5 cm 2 field. This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Altogether, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Secondary-electron imaging of bulk crystalline specimens in an aberration corrected $\text{STEM}$

Atomic-scale electron microscopy traditionally probes thin specimens, with thickness below 100 nm, and its feasibility for bulk samples has not been documented. Here in this study, we explore the practicality of scanning transmission electron microscope (STEM) imaging with secondary electrons (SE), using a silicon-wedge specimen having a maximum thickness of 18 μm. We find that the atomic structure is present in the entire thickness range of the SE images although the background intensity increases moderately with thickness. The consistent intensity of secondary electron (SE) images at atomic positions and the modest increase in intensity in between (background) observed in silicon suggest a limited contribution from SEs generated by backscattered electrons, a conclusion supported by our multislice calculations. We conclude that achieving atomic resolution in SE imaging for bulk specimens is indeed attainable using aberration-corrected STEM and that an aberration-corrected scanning electron microscope (SEM) may have the capacity for atomic-level resolution, holding great promise for future strides in materials research.

25 ENERGY STORAGE↗

Atomically Dispersed Metals on Well-Defined Supports including Zeolites and Metal–Organic Frameworks: Structure, Bonding, Reactivity, and Catalysis

When metals in supported catalysts are atomically dispersed, they are usually cationic and bonded chemically to supports. Investigations of noble metals in this class are growing rapidly, leading to discoveries of catalysts with new properties. Characterization of these materials is challenging because the metal atoms reside on surfaces that are typically nonuniform in composition and structure. We posit that understanding of structures and catalytic properties of these materials is emerging most strongly from investigations of structurally uniform catalysts (metal atoms dispersed on crystalline supports) which can be characterized incisively with atomic-resolution electron microscopy, X-ray absorption spectroscopy, and infrared spectroscopy, bolstered by density functional theory. We assess the literature of such catalysts supported on zeotype materials, metal–organic frameworks, and covalent organic frameworks. Finally, assessing characterization, reactivity, and catalytic performance of catalysts for oxidation, hydrogenation, the water–gas shift reaction, and others, we consider metal–support interactions and ligand effects for various metal–support combinations, evaluating the degree of structural uniformity of exemplary catalysts and summarizing structure–reactivity and structure–catalytic property relationships.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗

Investigation of SL 1115 X-ray telescope

A polished Kanigen coated beryllium mirror to be used in a glancing incidence X-ray telescope was evaluated. X-ray photographs of the image of a standard high resolution test target were recorded at 8.34 A and the focal plane of the telescope was determined. Reflection efficiency data was obtained using proportional counters and sources at wavelengths of 8.34, 13.3, and 44 A. These data were compared with similar data taken with another metal mirror. The results of the comparison are that the mirror tested in this program shows better resolution and less scattering than the other mirror previously tested. This mirror was chosen as the flight mirror for the SL 1115 X-Ray Telescope to fly on a Skylark sounding rocket. Also, a position sensitive detector placed in the focal plane of the SL 1115 X-Ray Telescope (flight payload) was successfully calibrated using a 10 arc second point source and at wavelengths of 8.34, 13.3, 27, and 44 A.

Froechtenigt, J. F.↗

Description of the ISEE satellite-to-satellite kilometric wavelength interferometer system

The International Sun-Earth Explorer (ISEE) spacecraft 1 and 2 carry receivers for detecting electromagnetic waves with kilometric wavelengths. For selected receiver frequencies from 30 kHz to 2 MHz, a 10-kHz bandwidth channel is single-sideband mixed down to baseband. These analog data and a reference frequency, which is a submultiple of the local oscillator frequency, are transmitted to ground stations and tape recorded along with the precise time and frequency information. Cross correlation of these tape recorded signals constitutes a satellite-to-satellite interferometer with a fringe spacing of 0.4 to 41 arcmin (at a range of 10,000 to 100 km spacing between spacecraft for 250 kHz in frequency) and with a time-delay resolution of 32 microsec for a 10-kHz bandwidth, which gives an angular resolution of 3 min to 6 deg of arc. For kilometric radiation at earth, sources in the size range of 25 to 2500 km can be identified (from 20 earth radii) and located in relative position ranging from 0.02 to 2 earth radii, depending on spacecraft spacing. Reception and analysis of solar and Jovian bursts may also be possible.

Shawhan, S. D.↗

Gamma ray detection with long NaI/Tl/ scintillator bars

Test measurements with a prototype NaI(Tl) scintillator for energy, position, and timing measurements in gamma ray astronomy are reported. The scintillator bar is 100 x 5 x 5 cu cm in size, and allows detection of the arrival times and pulse heights of signals from two photomultiplier tubes, one at each end of the bar. Data is gathered on the energy loss, linear position, and time-of-flight of gamma ray interactions within the bar over an energy range of 0.5-20 MeV. A mean attenuation coefficient of 0.015/cm has been determined, as have a FWHM resolution of 5 cm, 9.4%, and 10 nsec at an energy of 0.662 MeV. At 1.25 MeV the timing resolution was 6 nsec, and at 6.13 MeV the spatial resolution was 2.2 cm. The instrument is a prototype of a Compton scatter telescope being constructed for two balloon flights, one each in the Northern and Southern Hemispheres, in 1984.

Zych, A. D.↗

Advanced Very High Resolution Radiometer (AVHRR) sensor comparison characteristics

Advantages and limitations of the AVHRR multichannel sea surface temperature (MCSST) detecting technique using NOAA satellites are discussed. The error characteristics of MCSST's from statistical tables and regional AVHRR error characteristics from global anomaly charts are also discussed. Some soruces of errors and positive findings are reviewed.

Mcclain, E. P.↗

Laser Rayleigh-Scattering During Space Shuttle Entry

Report presents detailed study of capabilities and requirements for equipment of proposed ultraviolet Rayleigh-scattering instrument to be carried aboard Space Shuttle. Density of atmosphere around flightpath measured. With accuracy and resolution, measurements adequate for detection of small-scale meteorological structure affecting analysis of flight dynamic data of reentering spacecraft. Also discusses extensions of concept to measurements of location of, and density as function of position in, shock wave of Space Shuttle. Measurements provide baseline data for verification of computer models of high-enthalpy hypersonic, nonequilibrium, and viscous conditions.

Mckenzie, Robert L.↗