Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Creep-fatigue behavior of alloy 617 - 18581

Alloy 617 is the leading candidate material for the intermediate heat exchanger for the very high temperature reactor (VHTR). It is thought that creep-fatigue resistance is likely to be the life-limiting material property for this application. As part of evaluating the behavior of this material in the expected service conditions, creep fatigue testing of Alloy 617 was performed at 850 and 950 deg. C for several strain ranges and hold times. Creep-fatigue degradation was observed, characterized by reduced cycles to failure when a hold time was added at peak tensile strain, compared to fatigue values. At 850 deg. C, increasing the tensile hold duration continued to degrade the creep fatigue resistance, at least to the investigated strain controlled hold time of up to 60 minutes at the 0.3% strain range and 240 minutes at the 1.0% strain range. At 950 deg. C, the creep fatigue cycles to failure are not further reduced with increasing hold duration, indicating saturation occurs at relatively short hold times. The creep and fatigue damage fractions have been calculated using the ASME methodology and plotted on a creep fatigue interaction D diagram. The impact of selecting different parameters on calculation of the creep damage fraction has been evaluated and will be discussed in this paper. Additional damage fractions from creep fatigue tests at 800 and 1000 deg. C on a different heat of Alloy 617 have been determined and are plotted on the D diagram along with results of the current testing. The combined data represent a comprehensive evaluation of Alloy 617 behavior under the ASME methodology and result in a consistent creep-fatigue damage envelope. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Simplified Fission Product Poison Model for Operator Training

Accurate but simple models of xenon and samarium concentration variation with reactor power changes are desirable to support development of reactor theory fundamentals training material for power or research reactor operators. Generation of plots of xenon and samarium concentrations with time can be made without reliance on the nuclear properties of a particular reactor core if the differential equations governing the time-dependent behavior of xenon and samarium and their precursors are recast in terms of equilibrium values. There is currently no method available for generating realistic plots of fission product behavior during power transients that is accessible to Operations training instructors other than hand drawings or adaption of existing commercial material. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

EXSAN: An Interactive Version of the Nuclear Cross Section Data Handbook - 25687

Neutron cross section measurements and data files have advanced significantly since 1989 when Los Alamos published 'A Nuclear Cross Section Data Handbook', a detailed compendium of point-wise cross section plots and pie charts of relative contributions of individual reactions to the total cross section for 129 isotopes. Other compendiums with similar data and analysis tools have also been published. The intent of this work is to develop a modern, open-source application for interactive exploration and analysis of Evaluated Nuclear Data File (ENDF) libraries that also allows users to create their own 'Nuclear Cross Section Data Handbooks'. EXSAN is an easy-to-use graphical user interface application for exploring ENDF photon and neutron cross sections developed in Python. In addition to interactive plotting, EXSAN includes methods for computing rank-order lists of cross section for any energy and calculating composite cross sections for isotopic and elemental compositions and additional batch automation features. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance Improvements of Poincaré Analysis for Exascale Fusion Simulations

Understanding the time-varying magnetic field in a fusion device is critical for the successful design and construction of clean-burning fusion power plants. Poincaré analysis provides a powerful method for the visualization of magnetic fields in fusion devices. However, Poincaré plots can be very computationally expensive making it impractical, for example, to generate these plots in situ during a simulation. In this short paper, we describe a collaboration among computer science and physics researchers to develop a new Poincaré tool that provides a significant reduction in the time to generate analysis results.

Pugmire, Dave↗

Reactor Network Analysis with Various Reaction Mechanisms to Investigate Hydrogen vs. Methane Fuel at Varying Flame Temperatures with Experimental Data

Emissions data were evaluated for a set of test hardware that adapts Collins Aerospace’s aeroengine liquid fueled injector technology to a ground-based turbine. The hardware was specifically developed to operate on 100% hydrogen; however it has the ability to operate on both pure methane and hydrogen and mixtures in between. 16 injector configurations and seven factors (air split, fuel and air swirl, pressure drop, preheat temperature, fuel composition, and flame temperature) were investigated based on a Box Behnken statistical model. Of the 16, configuration 3 was selected for further discussion being in the middle of the statistical design space. A chemical reactor network was developed based on the experimental data obtained and was assessed with three different mechanisms: GRI Mech 3.0, UCSD, and Galway. All factors were held constant except the fuel composition to directly compare chemical pathways for methane and hydrogen. This study was conducted across different flame temperatures of 1500K, 1675K, and 1850K for both hydrogen and methane. Additional lower flame temperatures of 1100K and 1300K were evaluated for hydrogen. Moreover, results for fully premixed and non-premixed results were compared to obtain information on the implications of mixedness on emissions. These results were compared with the Leonard and Stegmaier plot for methane and a similar plot was constructed for hydrogen.

08 HYDROGEN↗

Search for 2p2h Interactions in the NOνA Near Detector

The physics of 2p2h interactions and their contribution to the NO$\nu$A near detector data are not fully understood. This study attempts to shed some light on these interactions and the accuracy of the models used to simulate them through a search for a specific 2p2h interaction in the NO$\nu$A near detector. By performing an event selection algorithm based on particle identifier algorithms run over reconstructed data, a signal region is created to minimize the background while maximizing the number of 2p2h events where a muon neutrino interacts with a neutron and a proton coupled by a meson exchange current and produces two protons and one muon. In the signal region, separation is found between the signal events and the background in plots of the angles between the protons and the muon. Although a full statistical analysis is not completed in this study, comparing the angle plots for simulation and data shows that the model used to simulate the events reasonably approximates reality and that the near detector data likely includes signal events. Signal events are also identified in event displays, further indicating that there is some contribution of the signal to the overall NO$\nu$A near detector data.

Gable, Kyle↗

Oscilloscope Data Push Program

This paper details the development of a Python program designed to automate the data acquisition and conversion for an oscilloscope for the purposes of a one-off/temporary data acquisition system for users that readily need data, and do not have the option of obtaining a Data Acquisition (DAQ) solution. Creating DAQ systems for analyzing a system requires expensive electronics and a dedicated team of engineers for support. Traditionally, manual data collection and processing are time consuming and prone to error. By automating these processes, the cost, efficiency and accuracy of data handling are improved upon. This project involves the creation of a program that interacts with the oscilloscope. During this interaction, there are various functions being performed such as the acquisition of waveform data via floating points, generating plots with the acquired wave points, and storing of floating points in a CSV file format for future reference and plotting purposes. While the initial aim of the project included continuous logging to a cloud database, this was deferred due to time constraints. The results portrayed an almost-instant rate of data collection with a buffer time, showcasing the potential for further integration and real-time data processing.

Osei-Tutu, Jason↗

Impedance-Based State-of-Health Estimation for Lithium-Ion Battery Management Systems

This paper discusses an impedance-based state-of-health (SOH) estimation for lithium-ion battery management systems. Features obtained from the Nyquist plot of the electrochemical impedance spectroscopy (EIS) are utilized to estimate the SOH. Two commercial lithium-ion batteries were aged (cycled) in the laboratory to collect aging and impedance data. An algorithm for SOH estimation is presented and evaluated. The performance evaluation results show that the SOH features extracted from the Nyquist plot can be utilized for SOH estimation. Estimated SOH values can be then utilized in various battery management systems (BMS) functions such as for calibrating the available capacity, adjusting charging/discharging strategies, and protection.

Al-Smadi, Mohammad↗

CritView User’s Guide Rev. 2

This document serves as a user’s guide for the CritView code, version 1.05. It supersedes the previous revision (Rev. 1), which was applicable to version 1.04 of CritView. This release of CritView also includes version 1.09 of the database, which replaces version 1.08. The CritView code is used as an electronic equivalent of a nuclear criticality handbook (e.g., ARH-600). This code takes an electronic data library and allows the user to plot data as needed. This approach has two distinct advantages over a paper handbook. First, the database can be easily expanded to include additional data sources (e.g., other handbooks, configurations, or modeling techniques). Secondly, the code provides flexibility by allowing the user to easily change the units and parameters of the plots.

Finfrock, Scott H. [Savannah River Nuclear Solutio↗

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment’s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force

We report a rapid and robust separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing in a microfluidic device. A piezoelectric transducer (PZT) generates acoustic standing waves in the microchannel. These standing waves induce acoustic radiation force fields that direct microparticles towards the nodes (i.e., pressure minima) or the anti-nodes (i.e., pressure maxima) of the standing waves depending on the relative compressidensity between the particle and the suspending liquid.[1] For particles larger than 2 {micro}m, the transverse velocities generated by these force fields enable continuous, high throughput separation. Extensive work in the last decade [2-4] has demonstrated acoustic focusing for manipulating microparticles or biological samples in microfluidic devices. This prior work has primarily focused on experimental realization of acoustic focusing without modeling or with limited one-dimensional modeling estimates. We recently developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices.[1] Here we compare results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. Figure 1 shows a typical experimental acoustic focusing result for microparticles (diameter = 2.0 {micro}m) in a 500 {micro}m wide by 200 {micro}m deep microchannel. In this case, the PZT driving frequency and voltage are, respectively, 1.459 MHz and 6.6 V. The microparticles tightly focus (full width half maximum (FWHM) {approx}30 {micro}m) less than 30 s after the initiation of the acoustic field. We simulated the same geometry and operating conditions for comparison. The surface plot in Figure 2 illustrates the two-dimensional pressure field orthogonal to the flow direction (x-direction) from the simulation. The superimposed vector plot shows the acoustic radiation force in this plane. The dark regions and the light regions respectively represent the nodes and anti-nodes of the acoustic pressure field. The corresponding force field predicts acoustic focusing at the center of the microchannel, which is confirmed by the experimental results shown in Figure 1. We demonstrated the separation of Saccharomyces cerevisiae (typical cell size of 4-6 {micro}m depending on the cell growth stage, measured using a Coulter counter) and MS2 bacteriophage (typical diameter {approx}30 nm [5]) using acoustic focusing (Figure 3). A mixture of S. cerevisiae and MS2 labeled with Ribogreen was prepared and injected into one inlet of the microchip (i.e., half of the microchannel was filled with the sample). We varied driving voltages from 1.96 to 4.76 V, while fixing the driving frequency at 1.459 MHz and flow rate at 20 {micro}l/min. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. Increased driving voltages enhanced the acoustic focusing of the yeast cells thereby achieving good separation. We are able to achieve yields of > 80% and sample purities of > 90% in this continuous-flow sample preparation device.

42 ENGINEERING↗

Mercury + VisIt: Integration of a Real-Time Graphical Analysis Capability into a Monte Carlo Transport Code

Validation of the problem definition and analysis of the results (tallies) produced during a Monte Carlo particle transport calculation can be a complicated, time-intensive processes. The time required for a person to create an accurate, validated combinatorial geometry (CG) or mesh-based representation of a complex problem, free of common errors such as gaps and overlapping cells, can range from days to weeks. The ability to interrogate the internal structure of a complex, three-dimensional (3-D) geometry, prior to running the transport calculation, can improve the user's confidence in the validity of the problem definition. With regard to the analysis of results, the process of extracting tally data from printed tables within a file is laborious and not an intuitive approach to understanding the results. The ability to display tally information overlaid on top of the problem geometry can decrease the time required for analysis and increase the user's understanding of the results. To this end, our team has integrated VisIt, a parallel, production-quality visualization and data analysis tool into Mercury, a massively-parallel Monte Carlo particle transport code. VisIt provides an API for real time visualization of a simulation as it is running. The user may select which plots to display from the VisIt GUI, or by sending VisIt a Python script from Mercury. The frequency at which plots are updated can be set and the user can visualize the simulation results as it is running.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MCNPX graphics and arithmetic tally upgrades

The MCNPX MCPLOT package is the tool used to plot tallies and cross-sections. We report on an assortment of upgrades to MCPLOT that are intended to improve the appearance of two-dimensional tally and cross-section plots. We have also expanded the content and versatility of the MCPLOT 'help' command. Finally, we describe the initial phase of capability implementation to post-process tally data using arithmetic operations. These improvements will enable users to better display and manipulate simulation results.

97 MATHEMATICS AND COMPUTING↗

Numerical evaluation of effective unsaturated hydraulic properties for fractured rocks

To represent a heterogeneous unsaturated fractured rock by its homogeneous equivalent, Monte Carlo simulations are used to obtain upscaled (effective) flow properties. In this study, we present a numerical procedure for upscaling the van Genuchten parameters of unsaturated fractured rocks by conducting Monte Carlo simulations of the unsaturated flow in a domain under gravity-dominated regime. The simulation domain can be chosen as the scale of block size in the field-scale modeling. The effective conductivity is computed from the steady-state flux at the lower boundary and plotted as a function of the averaging pressure head or saturation over the domain. The scatter plot is then fitted using van Genuchten model and three parameters, i.e., the saturated conductivity K{sub s}, the air-entry parameter {alpha}, the pore-size distribution parameter n, corresponding to this model are considered as the effective K{sub s}, effective {alpha}, and effective n, respectively.

58 GEOSCIENCES↗

Acoustic monitoring method and system in laser-induced optical breakdown (LIOB)

An acoustic monitoring method and system in laser-induced optical breakdown (LIOB) provides information which characterize material which is broken down, microbubbles in the material, and/or the microenvironment of the microbubbles. In one embodiment of the invention, femtosecond laser pulses are focused just inside the surface of a volume of aqueous solution which may include dendrimer nanocomposite (DNC) particles. A tightly focused, high frequency, single-element ultrasonic transducer is positioned such that its focus coincides axially and laterally with this laser focus. When optical breakdown occurs, a microbubble forms and a shock or pressure wave is emitted (i.e., acoustic emission). In addition to this acoustic signal, the microbubble may be actively probed with pulse-echo measurements from the same transducer. After the microbubble forms, received pulse-echo signals have an extra pulse, describing the microbubble location and providing a measure of axial microbubble size. Wavefield plots of successive recordings illustrate the generation, growth, and collapse of microbubbles due to optical breakdown. These same plots can also be used to quantify LIOB thresholds.

47 OTHER INSTRUMENTATION↗

Uranium 238U/235U isotope ratios as indicators of reduction: Results from an in situ biostimulation experiment at Rifle, Colorado, USA

The attenuation of groundwater contamination via chemical reaction is traditionally evaluated by monitoring contaminant concentration through time. However, this method can be confounded by common transport processes (e.g. dilution, sorption). Isotopic techniques bypass the limits of concentration methods, and so may provide improved accuracy in determining the extent of reaction. We apply measurements of {sup 238}U/{sup 235}U to a U bioremediation field experiment at the Rifle Integrated Field Research Challenge Site in Rifle, Colorado (USA). An array of monitoring and injection wells was installed on a 100 m{sup 2} plot where U(VI) contamination was present in the groundwater. Acetate-amended groundwater was injected along an up-gradient gallery to encourage the growth of dissimilatory metal reducing bacteria (e.g. Geobacter species). During amendment, U concentration dropped by an order of magnitude in the experiment plot. We measured {sup 238}U/{sup 235}U in samples from one monitoring well by MC-ICP-MS using a double isotope tracer method. A significant {approx}1.00{per_thousand} decrease in {sup 238}U/{sup 235}U occurred in the groundwater as U(VI) concentration decreased. The relationship between {sup 238}U/{sup 235}U and concentration corresponds approximately to a Rayleigh distillation curve with an effective fractionation factor ({alpha}) of 1.00046. We attribute the observed U isotope fractionation to a nuclear field shift effect during enzymatic reduction of U(VI){sub (aq)} to U(IV){sub (s)}.

54 ENVIRONMENTAL SCIENCES↗