Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

SU-E-T-457: Design and Characterization of An Economical 192Ir Hemi-Brain Small Animal Irradiator

Purpose: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. Methods: A high dose rate 192Ir brachytherapy source from a commercially available afterloader was used with a 1.3 centimeter thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit is equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film. The penumbra from the small animal irradiator was compared under similar collimating conditions to the penumbra from 6 MV photons, 6 MeV electrons, and 20 MeV electrons from a linear accelerator as well as 300 kVp photons from an orthovoltage unit and Monte Carlo simulated 90 MeV protons. Results: The tungsten collimator provides a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator. Additionally, the penumbra was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. Conclusions: The small animal irradiator described here can be built for under $1,000 and used in conjunction with any commercial brachytherapy afterloader to provide a convenient and cost-effective option for small animal irradiation experiments. The unit offers high dose rate delivery and sharp penumbra, which is ideal for hemi-brain irradiation of mice. With slight modifications to the design, irradiation of sites other than the brain could be accomplished easily. Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring a sharp penumbra.

07 ISOTOPE AND RADIATION SOURCES↗

Effects of various Mg/Si ratios on microstructure and performance property of Al-Mg-Si alloy cables

High quality AA6101 aluminum cables are critical to electrical industry to meet the energy consumption requests. In the present work, the influence of Mg/Si ratios on the electrical conductivity and mechanical properties of AA6101 aluminum alloy was investigated. Wheatstone Bridge method and tensile test were employed to characterize the mechanical properties. X-ray Diffraction (XRD), Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) were used to understand the morphology of the precipitation and the mechanism of age hardening. It is found that excessive Si benefits high strength and high conductivity while excessive Mg plays a negative role in the strength and the conductivity of AA6101 cables. Excessive Si elements promote both the precipitating rate and quantity of β″ phase therefore increase the tensile strength. Excessive Si elements also help with decreasing the lattice distortion, which contributes to the enhancement of the conductivity. Excessive Mg elements lead to more dissolved Mg after aging treatment, therefore increase lattice distortion of the matrix and promote the deposit of coarse Mg-enriched secondary phase. - Highlights: •A new available method to improve the mechanical and electrical properties of Al-Mg-Si alloy •Investigation on the role of various Mg/Si ratios in the changes of comprehensive performances •Discussions on the morphology of the precipitation phases and the mechanism of hardening.

36 MATERIALS SCIENCE↗

Adopting Biophysics Methods in Pursuit of Biogeophysical Research: Advancing the Measurement and Modeling of Electrical Signatures of Microbe-Mineral Transformations Impacting Contaminant Transport (Final Report)

This exploratory project involved laboratory experiments to investigate three hypotheses: (H1) Physics-based modeling of low-frequency dispersions (henceforth referred to as alpha) measured in broadband dielectric spectroscopy (DS) data can quantify pore-scale geometric changes impacting contaminant transport resulting from biomineralization; (H2) Physics-based modeling of high-frequency dispersions (henceforth referred to as beta) measured in broadband dielectric spectroscopy data can quantify rates of mineral growth in/on the cell wall; (H3) Application of this measurement and modeling approach can enhance geophysical interpretation of bioremediation experiments conducted at the RIFLE IFC by providing constraints on bioremediation efficiency (biomass concentration, mineral uptake within the cell wall, biomineralization rate). We tested H1 by performing DS measurements (alpha and beta range) on iron (Fe) particles of dimensions similar to microbial cells, dispersed within agar gels over a range of Fe concentrations. We have tested the ability of the physics-based modeling to predict volume concentrations of the Fe particles by assuming that the Fe particles are polarizable inclusions within an otherwise nonpolarizable medium. We evaluated the smallest volume concentration that can be detected with the DS method. Similar experiments and modeling have been performed on the sulfate-reducing bacteria D. vulgaris. Synchrotron x-ray absorption measurements were conducted to determine the local structure of biominerals coatings on D. vulgaris which were grown in the presence of different Fe concentrations. We imaged the mineral growth on cell wall using SEM. We used dielectric spectroscopy to differentiate between iron sulfide precipitates of biotic and abiotic nature. Biotic measurements were made on D. vulgaris bacteria grown in the presence of different concentrations of iron to form different thicknesses of iron sulfide precipitates around themselves and abiotic measurements were made on different concentrations of pyrrhotite particles suspended in agar. Results show a decrease in dielectric permittivity as a function of frequency for biotic minerals and an opposite trend is observed for abiotic minerals. Our results suggest that dielectric spectroscopy offers a noninvasive and fast approach for distinguishing between abiotic and biotic mineral precipitates.

54 ENVIRONMENTAL SCIENCES↗

A novel in situ trigger combination method

Searches for rare physics processes using particle detectors in high-luminosity colliding hadronic beam environments require the use of multi-level trigger systems to reject colossal background rates in real time. In analyses like the search for the Higgs boson, there is a need to maximize the signal acceptance by combining multiple different trigger chains when forming the offline data sample. In such statistically limited searches, datasets are often amassed over periods of several years, during which the trigger characteristics evolve and system performance can vary significantly. Reliable production cross-section measurements and upper limits must take into account a detailed understanding of the effective trigger inefficiency for every selected candidate event. We present as an example the complex situation of three trigger chains, based on missing energy and jet energy, that were combined in the context of the search for the Higgs (H) boson produced in association with a $W$ boson at the Collider Detector at Fermilab (CDF). We briefly review the existing techniques for combining triggers, namely the inclusion, division, and exclusion methods. We introduce and describe a novel fourth in situ method whereby, for each candidate event, only the trigger chain with the highest a priori probability of selecting the event is considered. We compare the inclusion and novel in situ methods for signal event yields in the CDF $WH$ search. This new combination method, by virtue of its scalability to large numbers of differing trigger chains and insensitivity to correlations between triggers, will benefit future long-running collider experiments, including those currently operating on the Large Hadron Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single–Column Model Simulations of Subtropical Marine Boundary–Layer Cloud Transitions Under Weakening Inversions

Results are presented of the GASS/EUCLIPSE single-column model inter-comparison study on the subtropical marine low-level cloud transition. A central goal is to establish the performance of state-of-the-art boundary-layer schemes for weather and climate models for this cloud regime, using large-eddy simulations of the same scenes as a reference. A novelty is that the comparison covers four different cases instead of one, in order to broaden the covered parameter space. Three cases are situated in the North-Eastern Pacific, while one reflects conditions in the North-Eastern Atlantic. A set of variables is considered that reflects key aspects of the transition process, making use of simple metrics to establish the model performance. Using this method some longstanding problems in low level cloud representation are identified. Considerable spread exists among models concerning the cloud amount, its vertical structure and the associated impact on radiative transfer. Here, the sign and amplitude of these biases differ somewhat per case, depending on how far the transition has progressed. After cloud breakup the ensemble median exhibits the well-known “too few too bright” problem. The boundary layer deepening rate and its state of decoupling are both underestimated, while the representation of the thin capping cloud layer appears complicated by a lack of vertical resolution. Encouragingly, some models are successful in representing the full set of variables, in particular the vertical structure and diurnal cycle of the cloud layer in transition. An intriguing result is that the median of the model ensemble performs best, inspiring a new approach in subgrid parameterization.

54 ENVIRONMENTAL SCIENCES↗

Development of a 3D optical scanning-based automatic quality assurance system for proton range compensators

Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation. Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS). To verify the geometrical accuracy, the planned RC data (PRC), calculated with the treatment planning system (TPS), were reconstructed and coregistered with the measured RC data (MRC) based on the beam isocenter. The PRC and MRC inner surfaces were compared with composite analysis (CA) using 3DVS, using the CA pass rate for quantitative analysis. To evaluate the detection accuracy of the system, the authors designed a fake PRC by artificially adding small cubic islands with side lengths of 1.5, 2.5, and 3.5 mm on the inner surface of the PRC and performed CA with the depth difference and distance-to-agreement tolerances of [1 mm, 1 mm], [2 mm, 2 mm], and [3 mm, 3 mm]. In addition, the authors performed clinical tests using seven RCs [computerized milling machine (CMM)-RCs] manufactured by CMM, which were designed for treating various disease sites. The systematic offsets of the seven CMM-RCs were evaluated through the automatic registration function of AutoRCQA. For comparison with conventional technique, the authors measured the thickness at three points in each of the seven CMM-RCs using a manual depth measurement device and calculated thickness difference based on the TPS data (TPS-manual measurement). These results were compared with data obtained from 3DVS. The geometrical accuracy of each CMM-RC inner surface was investigated using the TPS data by performing CA with the same criteria. The authors also measured the net processing time, including the scan and analysis time. Results: The AutoRCQA system accurately detected all fake objects in accordance with the given criteria. The median systematic offset of the seven CMM-RCs was 0.08 mm (interquartile range: −0.25 to 0.37 mm) and −0.08 mm (−0.58 to 0.01 mm) in the X- and Y-directions, respectively, while the median distance difference was 0.37 mm (0.23–0.94 mm). The median thickness difference of the TPS-manual measurement at points 1, 2, and 3 was −0.4 mm (−0.4 to −0.2 mm), −0.2 mm (−0.3 to 0.0 mm), and −0.3 mm (−0.6 to −0.1 mm), respectively, while the median difference of 3DMS was 0.0 mm (−0.1 to 0.2 mm), 0.0 mm (−0.1 to 0.3 mm), and 0.1 mm (−0.1 to 0.2 mm), respectively. Thus, 3DMS showed slightly better values compared to the manual measurements for points 1 and 3 in statistical analysis (p < 0.05). The average pass rate of the seven CMM-RCs was 97.97% ± 1.68% for 1-mm CA conditions, increasing to 99.98% ± 0.03% and 100% ± 0.00% for 2- and 3-mm CA conditions, respectively. The average net analysis time was 18.01 ± 1.65 min. Conclusions: The authors have developed an automated 3DS-based proton RC QA system and verified its performance. The AutoRCQA system may improve the accuracy and efficiency of QA for RCs.

07 ISOTOPE AND RADIATION SOURCES↗

Adaptive Mesh Refinement for Parallel in Time Methods

The project applied the multigrid-reduction-in-time (MGRIT) algorithm to an existing sub-cycled adaptive mesh refinement (AMR) code to investigate the performance of flows dominated by inertial physics. Previous work demonstrated good performance from MGRIT+AMR applied to flows dominated by diffusive physics. Consistent with previous experience, inertial physics negatively affected convergence rates and performance. Efforts to circumvent this issue by appealing to the physics of turbulence were investigated. It has been demonstrated that scales can be effectively transferred between multigrid levels for a turbulent flow resulting in a) partial convergence observed and b) nearly identical results to sequential time-stepping. Performance improvements have not yet been demonstrated - attempts at coarsening the grid on coarser MG levels compromises the solution quality and leads to divergence. This report summarize the accomplishments for the time-frame from 10/5/2020 to 12/31/2020 with an informal no-cost-extension to 05/20/2021

97 MATHEMATICS AND COMPUTING↗

Estimation of the Water Table Position in Unconfined Aquifers with MODFLOW 6

Abstract The numerical estimation of the position of the water table in unconfined aquifers is important for many practical applications. Its determination through observations or analytical methods is restricted to a few cases. Therefore, it is often estimated through numerical simulations, which may be affected by numerical artifacts and/or poor stability. We use MODFLOW to estimate the position of the water table for a seemingly simple example problem and demonstrate difficulties that can be faced when performing this kind of numerical simulation. We explain the causes for the numerical challenges that originate from the properties of the mathematical equations that must be solved. Based on the results of more than 600 steady‐state simulations, we show how the stability of the numerical solution can be affected by the values of physical parameters that define the problem (e.g., recharge rate, anisotropy ratio, and other parameters that control the numerical algorithm such as settings of the linear and nonlinear solution methods). Finally, we comment on some best practices to apply numerical simulations to estimate the water table position.

Geology↗

Enhanced performance of wearable piezoelectric nanogenerator fabricated by two-step hydrothermal process

A simple two-step hydrothermal process was proposed for enhancing the performance of the nanogenerator on flexible and wearable terylene-fabric substrate. With this method, a significant enhancement in output voltage of the nanogenerator from ∼10 mV to 7 V was achieved, comparing with the one by conventional one-step process. In addition, another advantage with the devices synthesized by two-step hydrothermal process was that their output voltages are only sensitive to strain rather than strain rate. The devices with a high output voltage have the ability to power common electric devices and will have important applications in flexible electronics and wearable devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy

Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r{sub s}) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI{sub SPORT}) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r{sub s} values of contrast to the global gamma passing rates with criteria of 2%/2 mm, 2%/1 mm, and 1%/2 mm were 0.536, 0.473, and 0.718, respectively. The respective values for variance were 0.551, 0.481, and 0.688. In the case of local gamma passing rates, the r{sub s} values of contrast were 0.547, 0.578, and 0.620, respectively, and those of variance were 0.519, 0.527, and 0.569. All of the r{sub s} values in those cases were statistically significant (p < 0.003). In the cases of global and local gamma passing rates, MI{sub SPORT} showed the highest correlations among the conventional modulation indices. For global passing rates, r{sub s} values of MI{sub SPORT} were −0.420, −0.330, and −0.632, respectively, and those for local passing rates were −0.455, −0.490 and −0.502. The values of r{sub s} of contrast, variance, and MI{sub SPORT} with the MLC errors were −0.863, −0.828, and 0.795, respectively, all with statistical significances (p < 0.001). The correlations with statistical significances between variance and dose-volumetric differences were observed more frequently than the others. Conclusions: The contrast (d = 1) and variance (d = 1) calculated from fluence maps of VMAT plans showed considerable correlations with the plan deliverability, indicating their potential use as indicators for assessing the degree of modulation of VMAT plans. Both contrast and variance consistently showed better performance than the conventional modulation indices for VMAT.

60 APPLIED LIFE SCIENCES↗

X-Ray Spectra from General Relativistic Radiation Magnetohydrodynamic Simulations of Thin Disks

We compare X-ray emission from several general relativistic, multifrequency, radiation magnetohydrodynamic simulations of thin black hole accretion disks with different accretion rates and spins. The simulations were performed using the M1 closure scheme, resolved with 12 frequency (energy) bins logarithmically spaced from 5 × 10 −3 to 5 × 10 3 ​​​ keV. We apply a general relativistic Monte Carlo transport code to postprocess the simulation data with greater fidelity in frequency resolution and Compton scattering treatment. Despite the relatively few energy bins and Kompaneets approximation to Compton scattering utilized in the M1 method, we find generally good agreement between the methods. Both produce prominent thermal profiles with peaks around 2–2.5 keV, where agreement is particularly strong and representative of the soft state. Both also find weaker (lower-luminosity) thermally sourced emission extending out to 100 keV due to the hotter innermost regions of the disks. Inverse Compton scattering becomes increasingly effective at hardening spectral outputs with increasing black hole spin, and becomes the dominant mechanism for photons that escape with energies between 10 to several hundred keV. At very high rates of spin, the radiation flux in this upscattered component becomes comparable to the thermal flux, a phenomenon typically associated with intermediate states. Beyond 10 4 keV, we observe faint, free–free emission from hot, optically thin coronal regions developing near the horizon, common to both spinning and nonspinning black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Strategy of Using Intratreatment Hypoxia Imaging to Selectively and Safely Guide Radiation Dose De-escalation Concurrent With Chemotherapy for Locoregionally Advanced Human Papillomavirus–Related Oropharyngeal Carcinoma

Purpose: To report a small substudy of an ongoing large, multi-arm study using functional imaging to assess pre-/intratreatment hypoxia for all head and neck cancer, in which we hypothesized that pre- and early-treatment hypoxia assessment using functional positron emission tomography (PET) imaging may help select which human papillomavirus (HPV)-positive (HPV{sup +}) oropharyngeal cancer (OPC) patients can safely receive radiation de-escalation without jeopardizing treatment outcomes. Methods and Materials: Patients with HPV{sup +} oropharyngeal carcinoma were enrolled on an institutional review board–approved prospective study of which de-escalation based on imaging response was done for node(s) only. Pretreatment {sup 18}F-fluorodeoxyglucose and dynamic {sup 18}F-FMISO (fluoromisonidazole) positron emission tomography (PET) scans were performed. For patients with pretreatment hypoxia on{sup 18}F-FMISO PET (defined as a >1.2 tumor to muscle standard uptake value ratio), a repeat scan was done 1 week after chemoradiation. Patients without pretreatment hypoxia or with resolution of hypoxia on repeat scan received a 10-Gy dose reduction to metastatic lymph node(s). The 2-year local, regional, distant metastasis–free, and overall survival rates were estimated using the Kaplan-Meier product-limit method. A subset of patients had biopsy of a hypoxic node done under image guidance. Results: Thirty-three HPV{sup +} OPC patients were enrolled in this pilot study. One hundred percent showed pretreatment hypoxia (at primary site and/or node[s]), and among these, 48% resolved (at primary site and/or node[s]); 30% met criteria and received 10-Gy reduction to the lymph node(s). At the median follow-up of 32 months (range, 21-61 months), the 2-year locoregional control rate was 100%. One patient failed distantly with persistence of hypoxia on {sup 18}F-FMISO PET. The 2-year distant metastasis–free rate was 97%. The 2-year OS rate was 100%. Hypoxia on imaging was confirmed pathologically. Conclusions: Hypoxia is present in HPV{sup +} tumors but resolves within 1 week of treatment in 48% of cases either at the primary site and/or lymph node(s). Our 100% locoregional control rate suggests that intratreatment functional imaging used to selectively de-escalate node(s) to 60 Gy was confirmed safe using our stringent imaging criteria. Intratreatment functional imaging warrants further study to determine its ultimate role in de-escalation treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An investigation of a novel reusable radiochromic sheet for 2D dose measurement

Purpose Radiochromic film remains a useful and versatile clinical dosimetry tool. Current film options are single use. Here, we introduce a novel prototype two‐dimensional (2D) radiochromic sheet, which optically clears naturally at room temperature after irradiation and can be reused. We evaluate the sheets for potential as a 2D dosimeter and as a radiochromic bolus with capability for dose measurement. Methods A novel derivative of reusable Presage ® was manufactured into thin sheets of 5 mm thickness. The sheets contained 2% cumin‐leucomalachitegreen‐diethylamine (LMG‐DEA) and plasticizer (up to 25% by weight). Irradiation experiments were performed to characterize the response to megavoltage radiation, including dose sensitivity, temporal decay rate, consistency of repeat irradiations, intra and inter‐sheet reproducibility, multi‐modality response (electrons and photons), and temperature sensitivity (22°C to 36°C). The local change in optical‐density (ΔOD), before and after radiation, was obtained with a flat‐bed film scanner and extracting the red channel. Repeat scanning enabled investigation of the temporal decay of ΔOD. Additional studies investigated clinical utility of the sheets through application to IMRT treatment plans (prostate and a TG119 commissioning plan), and a chest wall electron boost treatment. In the latter test, the sheet performed as a radiochromic bolus. Results The radiation induced OD change in the sheets was found to be proportional to dose and to exponentially decay to baseline in ~24 h (R2 = 0.9986). The sheet could be reused and had similar sensitivity (within 1% after the first irradiation) for at least eight irradiations. Importantly, no memory of previous irradiations was observed within measurement uncertainty. The consistency of dose response from photons (6 and 15 MV) and electrons (6–20 MeV) was found to be within calibration uncertainty (~1%). The dose sensitivity of the sheets had a temperature dependence of 0.0012 ΔOD/°C. For the short (1 min) single field IMRT QA verification, good agreement was observed between the Presage sheet and EBT film (gamma pass rate 97% at 3% 3 mm dose‐difference and distance‐to‐agreement tolerance, with a 10% threshold). For the longer (~13 min) TG‐119 9‐field IMRT verification the gamma agreement was lower at 93% pass rate at 5% 3 mm, 10% threshold, when compared with Eclipse. The lower rate is attributed to uncertainty arising from signal decay during irradiation and indicates a current limitation. For the electron cutout treatment, both Presage and EBT agreed well (within 2% RMS difference) but differed from the Eclipse treatment plan (~7% RMS difference) indicating some limitations to the Eclipse modeling in this case. The worst case estimates of uncertainty introduced by the signal decay for deliveries of 2, 5, and 10 min are 0.6%, 1.4%, and 2.8% respectively. Conclusions Reusable Presage sheets show promise for 2D dose measurement and as a radiochromic bolus for in vivo dose measurement. The current prototype is suitable for deliveries of length up to 5 min, where the uncertainty introduced by signal decay is anticipated to be ~1% (worst case 1.4%), or for longer deliveries where there is no temporal modulation (e.g. physical compensators, or open beams). Additionally, spatial resolution is limited by sheet thickness and scanner resolution, resulting in a practical resolution of 0.8 mm.

Collins, Cielle↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

Fast Multilevel Solvers for a Class of Discrete Fourth Order Parabolic Problems

In this paper, we study fast iterative solvers for the solution of fourth order parabolic equations discretized by mixed finite element methods. We propose to use consistent mass matrix in the discretization and use lumped mass matrix to construct efficient preconditioners. We provide eigenvalue analysis for the preconditioned system and estimate the convergence rate of the preconditioned GMRes method. Furthermore, we show that these preconditioners only need to be solved inexactly by optimal multigrid algorithms. Our numerical examples indicate that the proposed preconditioners are very efficient and robust with respect to both discretization parameters and diffusion coefficients. We also investigate the performance of multigrid algorithms with either collective smoothers or distributive smoothers when solving the preconditioner systems.

97 MATHEMATICS AND COMPUTING↗

Improving Corrosion Resistance and Corrosive Wear Resistance of Aluminum Alloy Drill Pipe by Surface Nanocrystallization and Micro-arc Oxidation

To improve the corrosion and wear resistance performance of aluminum alloy drill pipes in geological and petroleum drilling applications, a strengthening coating was prepared on the surface of the 2618 aluminum alloy by combining treatment with ultrasonic cold forging technology (UCFT) and micro-arc oxidation (MAO). The effects of the strengthening coating on the corrosion and wear resistance of the aluminum alloy were evaluated by electrochemical and tribological tests. The results demonstrated that the corrosion and wear resistance of the aluminum alloy were improved by the UCFT and MAO technologies, especially the salt corrosion resistance. The corrosion morphology of the strengthening coating primarily included pitting, micro-cracks and NaCl attachment. In addition, the UCFT + MAO composite coating exhibited the best wear performance. The wear rate of the UCFT + MAO composite coating was lower than that of the aluminum alloy by 94%. The results provided support for this excellent surface treatment technology for the corrosion and wear resistance of aluminum alloy drill pipes, and they also present a feasible evaluation method for drill pipes.

36 MATERIALS SCIENCE↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards high data-rate diffusive molecular communications: A review on performance enhancement strategies

Diffusive molecular communications (DiMC) have recently gained attention as a candidate for nano- to micro- and macro-scale communications due to its simplicity and energy efficiency. As signal propagation is solely enabled by Brownian motion mechanics, DiMC faces severe inter-symbol interference (ISI), which limits reliable and high data-rate communications. Herein, recent literature on DiMC performance enhancement strategies is surveyed; key research directions are identified. Signaling design and associated design constraints are presented. Here, studies on fundamental information theoretic limits of DiMC channel are reviewed. Classical and novel transceiver designs are discussed with an emphasis on methods for ISI mitigation and performance-complexity tradeoffs. Key parameter estimation strategies such as synchronization and channel estimation are considered in conjunction with asynchronous and timing error robust receiver methods. Finally, source and channel coding in the context of DiMC is presented.

42 ENGINEERING↗