Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Increases in Future AR Count and Size: Overview of the ARTMIP Tier 2 CMIP5/6 Experiment

Abstract The Atmospheric River (AR) Tracking Method Intercomparison Project (ARTMIP) is a community effort to systematically assess how the uncertainties from AR detectors (ARDTs) impact our scientific understanding of ARs. This study describes the ARTMIP Tier 2 experimental design and initial results using the Coupled Model Intercomparison Project (CMIP) Phases 5 and 6 multi‐model ensembles. We show that AR statistics from a given ARDT in CMIP5/6 historical simulations compare remarkably well with the MERRA‐2 reanalysis. In CMIP5/6 future simulations, most ARDTs project a global increase in AR frequency, counts, and sizes, especially along the western coastlines of the Pacific and Atlantic oceans. We find that the choice of ARDT is the dominant contributor to the uncertainty in projected AR frequency when compared with model choice. These results imply that new projects investigating future changes in ARs should explicitly consider ARDT uncertainty as a core part of the experimental design.

54 ENVIRONMENTAL SCIENCES↗

First beam tests of prototype silicon modules for the CMS High Granularity Endcap Calorimeter

The High Luminosity phase of the Large Hadron Collider will deliver 10 times more integrated luminosity than the existing collider, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry. As part of its upgrade program, the Compact Muon Solenoid collaboration is designing a high-granularity calorimeter (HGCAL) to replace the existing endcap calorimeters. It will feature unprecedented transverse and longitudinal readout and triggering segmentation for both electromagnetic and hadronic sections. The electromagnetic section and a large fraction of the hadronic section will be based on hexagonal silicon sensors of 0.5–1 cm 2 cell size, with the remainder of the hadronic section being based on highly-segmented scintillators with silicon photomultiplier readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. First hexagonal silicon modules, using the existing Skiroc2 front-end ASIC developed for CALICE, have been tested in beams at Fermilab and CERN in 2016. Here, we present results from these tests, in terms of system stability, calibration with minimum-ionizing particles and resolution (energy, position and timing) for electrons, and the comparisons of these quantities with GEANT4-based simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of differential cross sections of Higgs boson production through gluon fusion in the $H\rightarrow WW^{*}\rightarrow e\nu \mu \nu$ final state at $\sqrt{s} = 13$ TeV with the ATLAS detector

Higgs boson production via gluon–gluon fusion is measured in the $H\rightarrow WW^{*}\rightarrow e\nu \mu \nu$ decay channel. The dataset utilized corresponds to an integrated luminosity of 139 fb -1 collected by the ATLAS detector from $\sqrt{s} = 13$ TeV proton–proton collisions delivered by the Large Hadron Collider between 2015 and 2018. Differential cross sections are measured in a fiducial phase space restricted to the production of at most one additional jet. The results are consistent with Standard Model expectations, derived using different Monte Carlo generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Wrapper to Use a Machine-Learning-Based Algorithm for Earthquake Monitoring

Seismology is one of the main sciences used to monitor volcanic activity worldwide. Fast, efficient, and accurate seismicity detectors are crucial to assess the activity level of a volcano in near–real time and to issue timely warnings. Traditional real–time seismic processing software uses phase onset pickers followed by a phase association algorithm to declare an event and estimate its location. The pickers typically do not identify whether the detected phase is a P or S arrival, which can have a negative impact on hypocentral location quality and complicates phase association. We implemented the deep–neural–network–based method PhaseNet to identify in real time P and S seismic waves on data from one– and three–component seismometers. We tuned the Earthworm binder_ew associator module to use the phase identification from PhaseNet to detect and locate the events, which we archive in a SeisComP3 database. We assessed the performance of the algorithm by comparing the results with existing catalogs built to monitor seismic and volcanic activity in Mayotte and the Lesser Antilles region. Our algorithm, which we refer to as PhaseWorm, showed promising results in both contexts and clearly outperformed the previous automatic method implemented in Mayotte. As a result, this innovative real–time processing system is now operational for seismicity monitoring in Mayotte and Martinique.

58 GEOSCIENCES↗

OASIS: Optimal Analysis-Specific Importance Sampling for event generation

We propose a technique called Optimal Analysis-Specific Importance Sampling (OASIS) to reduce the number of simulated events required for a high-energy experimental analysis to reach a target sensitivity. We provide recipes to obtain the optimal sampling distributions which preferentially focus the event generation on the regions of phase space with high utility to the experimental analyses. OASIS leads to a conservation of resources at all stages of the Monte Carlo pipeline, including full-detector simulation, and is complementary to approaches which seek to speed-up the simulation pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning

The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating μ + →e + γ decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR (μ + →e + γ) ≤ 4.2×10 –13 at 90% confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of 6×10 –14 . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG (7×10 7 μ + /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for an Excess of Events in the Super-Kamiokande Detector in the Directions of the Astrophysical Neutrinos Reported by the IceCube Collaboration

We introduce the results of a search in the Super-Kamiokande (SK) detector for excesses of neutrinos with energies above a few GeV that are in the direction of the track events reported in IceCube. Data from all SK phases (SK-I through SK-IV) were used, spanning a period from April 1996 to April 2016 and corresponding to an exposure of 225 kilotonne-years . We considered the 14 IceCube track events from a data set with 1347 livetime days taken from 2010 to 2014. We use Poisson counting to determine if there is an excess of neutrinos detected in SK in a 10 ° search cone (5 ° for the highest energy data set) around the reconstructed direction of the IceCube event. No abundant excess was found in any of the search directions we examined. We also looked for coincidences with a recently reported IceCube multiplet event. No events were detected within a ± 500 s time window around the first detected event, and no significant excess was seen from that direction over the lifetime of SK.

79 ASTRONOMY AND ASTROPHYSICS↗

Lithium Wall Conditioning And Surface Dust Detection On NSTX

Lithium evaporation onto NSTX plasma facing components (PFC) has resulted in improved energy confinement, and reductions in the number and amplitude of edge-localized modes (ELMs) up to the point of complete ELM suppression. The associated PFC surface chemistry has been investigated with a novel plasma material interface probe connected to an in-vacuo surface analysis station. Analysis has demonstrated that binding of D atoms to the polycrystalline graphite material of the PFCs is fundamentally changed by lithium - in particular deuterium atoms become weakly bonded near lithium atoms themselves bound to either oxygen or the carbon from the underlying material. Surface dust inside NSTX has been detected in real-time using a highly sensitive electrostatic dust detector. In a separate experiment, electrostatic removal of dust via three concentric spiral-shaped electrodes covered by a dielectric and driven by a high voltage 3-phase waveform was evaluated for potential application to fusion reactors

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Results of $\nu_e$ Appearance Analysis and Electron Neutrino Identification at NOvA

NOvA is a long-baseline accelerator-based neutrino oscillation experiment that is optimized for $\nu_\mu\to\nu_e$ measurements. It uses the upgraded NuMI beam from Fermilab and measures electron-neutrino appearance and muon-neutrino disappearance at its Far Detector in Ash River, Minnesota. The $\nu_e$ appearance analysis at NOvA aims to resolve the neutrino mass hierarchy problem and to constrain the CP-violating phase. The first data set of $2.74\times10^{20}$ protons on target (POT) equivalent exposure taken by NOvA has been analyzed. The first measurement of electron-neutrino appearance in NOvA provides solid evidence of $\nu_\mu\to\nu_e$ oscillation with the NuMI beam line. Electron-neutrino identification is the key ingredient for the $\nu_e$ appearance analysis. The electron-identification algorithm used to produce the primary results presented here compares 3-D shower-energy profiles with Monte Carlo prototypes to construct likelihoods for each particle hypothesis. Particle likelihoods, among other event-topology variables, are used as inputs to an Artificial Neural Network for the final electron-neutrino identification. The design and implementation of this algorithm is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Results of Electron-Neutrino Appearance Measurement at NOvA

NOvA is a long-baseline accelerator-based neutrino oscillation experiment that is optimized for $\nu_e$ measurements. It uses the upgraded NuMI beam from Fermilab and measures electron-neutrino appearance and muon-neutrino disappearance at its Far Detector in Ash River, Minnesota. The $\nu_e$ appearance analysis at NOvA aims to resolve the neutrino mass hierarchy problem and to constrain the CP-violating phase. The first measurement of electron-neutrino appearance in NOvA based on its first year's data was produced in 2015, providing solid evidence of $\nu_e$ oscillation with the NuMI beam line and some hints on mass-hierarchy and CP. This talk will discuss the second $\nu_e$ oscillation analysis at NOvA, which is based on 2 years of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. Here, in this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-G-207-00: Emerging Applications of X-Ray Imaging

Last few years has witnessed the development of novel of X-ray imaging modalities, such as spectral CT, phase contrast CT, and X-ray acoustic/fluorescence/luminescence imaging. This symposium will present the recent advances of these emerging X-ray imaging modalities and update the attendees with knowledge in various related topics, including X-ray photon-counting detectors, X-ray physics underlying the emerging applications beyond the traditional X-ray imaging, image reconstruction for the novel modalities, characterization and evaluation of the systems, and their practical implications. In addition, the concept and practical aspects of X-ray activatable targeted nanoparticles for molecular X-ray imaging will be discussed in the context of X-ray fluorescence and luminescence CT. Learning Objectives: Present background knowledge of various emerging X-ray imaging techniques, such as spectral CT, phase contrast CT and X-ray fluorescence/luminescence CT. Discuss the practical need, technical aspects and current status of the emerging X-ray imaging modalities. Describe utility and future impact of the new generation of X-ray imaging applications.

60 APPLIED LIFE SCIENCES↗

TU-G-207-02: Clinical Applications of X-Ray Phase Contrast Imaging: Where Do We Stand?

Last few years has witnessed the development of novel of X-ray imaging modalities, such as spectral CT, phase contrast CT, and X-ray acoustic/fluorescence/luminescence imaging. This symposium will present the recent advances of these emerging X-ray imaging modalities and update the attendees with knowledge in various related topics, including X-ray photon-counting detectors, X-ray physics underlying the emerging applications beyond the traditional X-ray imaging, image reconstruction for the novel modalities, characterization and evaluation of the systems, and their practical implications. In addition, the concept and practical aspects of X-ray activatable targeted nanoparticles for molecular X-ray imaging will be discussed in the context of X-ray fluorescence and luminescence CT. Learning Objectives: Present background knowledge of various emerging X-ray imaging techniques, such as spectral CT, phase contrast CT and X-ray fluorescence/luminescence CT. Discuss the practical need, technical aspects and current status of the emerging X-ray imaging modalities. Describe utility and future impact of the new generation of X-ray imaging applications.

60 APPLIED LIFE SCIENCES↗

TU-G-207-03: High Spatial Resolution and High Sensitivity X-Ray Fluorescence Imaging

Last few years has witnessed the development of novel of X-ray imaging modalities, such as spectral CT, phase contrast CT, and X-ray acoustic/fluorescence/luminescence imaging. This symposium will present the recent advances of these emerging X-ray imaging modalities and update the attendees with knowledge in various related topics, including X-ray photon-counting detectors, X-ray physics underlying the emerging applications beyond the traditional X-ray imaging, image reconstruction for the novel modalities, characterization and evaluation of the systems, and their practical implications. In addition, the concept and practical aspects of X-ray activatable targeted nanoparticles for molecular X-ray imaging will be discussed in the context of X-ray fluorescence and luminescence CT. Learning Objectives: Present background knowledge of various emerging X-ray imaging techniques, such as spectral CT, phase contrast CT and X-ray fluorescence/luminescence CT. Discuss the practical need, technical aspects and current status of the emerging X-ray imaging modalities. Describe utility and future impact of the new generation of X-ray imaging applications.

60 APPLIED LIFE SCIENCES↗

Flash Lamp Integrating Sphere Technique for Measuring the Dynamic Reflectance of Shocked Materials

Accurate reflectance (R) measurements of metals undergoing shock wave compression can benefit high pressure research in several ways. For example, pressure dependent reflectance measurements can be used to deduce electronic band structure, and discrete changes with pressure or temperature may indicate the occurrence of a phase boundary. Additionally, knowledge of the wavelength dependent emissivity (1 -R, for opaque samples) of the metal surface is essential for accurate pyrometric temperature measurement because the radiance is a function of both the temperature and emissivity. We have developed a method for measuring dynamic reflectance in the visible and near IR spectral regions with nanosecond response time and less than 1.5% uncertainty. The method utilizes an integrating sphere fitted with a xenon flash-lamp illumination source. Because of the integrating sphere, the measurements are insensitive to changes in surface curvature or tilt. The in-situ high brightness of the flash-lamp exceeds the sample’s thermal radiance and also enables the use of solid state detectors for recording the reflectance signals with minimal noise. Using the method, we have examined the dynamic reflectance of gallium and tin subjected to shock compression from high explosives. The results suggest significant reflectance changes across phase boundaries for both metals. We have also used the method to determine the spectral emissivity of shock compressed tin at the interface between tin and a LiF window. The results were used to perform emissivity corrections to previous pyrometry data and obtain shock temperatures of the tin/LiF interface with uncertainties of less than 2%.

Stevens, Gerald↗

Observation of Electron Neutrino Appearance in the NuMI Beam with the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment that uses two functionally identical detectors separated by 810 kilometers at locations 14 milliradians off-axis from the NuMI muon neutrino beam at Fermilab. At these locations the beam energy peaks at 2 GeV. This baseline is the longest in the world for an accelerator-based neutrino oscillation experiment, which enhances the sensitivity to the neutrino mass ordering. The experiment studies oscillations of the muon neutrino and anti-neutrino beam that is produced. Both detectors completed commissioning in the summer of 2014 and continue to collect data. One of the primary physics goals of the experiment is the measurement of electron neutrino appearance in the muon neutrino beam which yields measurements of the oscillation parameters sin 2 2θ 13 , δ , and the neutrino mass ordering within the standard model of neutrino oscillations. This thesis presents the analysis of data collected between February 2014 and May 2015, corresponding to 3.52 X 10 20 protons-on-target. In this first analysis NOvA recorded 6 electron neutrino candidates, which is a 3.3σ observation of electron neutrino appearance. The T2K experiment performs the same measurement on a baseline of 295 kilometers and has a 1 σ preference for the normal mass ordering over the inverted ordering over the phase space of the CP violating parameter δ, which is also weakly seen in the NOvA result. By the summer of 2016 NOvA will triple its statistics due to increased beam power and a completed detector. If electron neutrinos continue to be observed at the current rate NOvA will be able to establish a mass ordering preference at a similar confidence level to T2K.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quality assurance and quality control of the $26~\text {m}^2$ SiPM production for the DarkSide-20k dark matter experiment

DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with 50 tonnes of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text {m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text {m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77 K at the wafer level with a custom-designed probe station. As of March 2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm 2.5$%, which exceeds the 80% specification defined in the original DarkSide-20k production plan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of nanoparticle collision cross section distribution functions in low pressure plasma synthesis reactors via ion mobility spectrometry

Low pressure (< 20 Torr) non-thermal plasma flow tube reactors are often used for the synthesis of high purity nanoparticles (NPs) via nucleation and subsequent growth from vapor phase precursors. In spite of their utility, process monitoring (i.e. output NP size characterization) in such reactors is difficult, as there is a dearth of techniques available for online nanoparticle size distribution function measurement. In this study, we developed and applied an ion mobility spectrometry (IMS) system consisting of a low pressure differential mobility analyzer (LPDMA) and electrical detector to determine the collision cross section distribution functions of Si NPs synthesized in a radiofrequency non-thermal SiH4-Ar plasma operated at ~2 Torr (266 Pa). The collision cross section, roughly proportional to projected area, is a parameter quantifying the size and structure of nanometer scale species in the vapor phase. We introduce the collision cross section distribution function as a metric for potential use in online process monitoring in NP synthesis. Proper inversion of the collision cross section distribution function requires a priori knowledge of the LPDMA transfer function. We utilized a tandem differential mobility analyzer approach, coupled with a Twomey-Markwoski based scheme to determine LPDMA transfer functions. Subsequent application of these transfer functions in collision cross section distribution function determination showed that at the outlet of the non-thermal plasma flow tube reactor, both negatively and positively charged Si NPs persisted with nearly identical collision cross section distribution functions. NPs were found to have mode “mobility equivalent” diameters near 10 nm, and via TEM analysis were found to persist at the reactor outlet as small aggregates composed of ~5 nm diameter primary particles. Size distributions functions inferred from collision cross section measurements were compared to size distribution functions inferred from TEM images; excellent agreement was found between IMS and TEM for both mean mobility equivalent diameter and distribution function width. In total, this study shows that (1) IMS is a viable approach for process monitoring in non-thermal plasma NP flow tube synthesis systems, (2) although NPs are modestly aggregated at low-pressure plasma reactor outlets, the extent of aggregation is considerably less than observed in most atmospheric pressure and equilibrium NP synthesis systems (e.g. flames), and (3) after exiting the plasma reactor, the decharging of NPs from highly negatively charge states to a bipolar charge distribution likely drives aggregation on the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗