Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Approach to forecasting daily maximum ozone levels in St. Louis

Measurements taken in 1976 from the St. Louis Regional Air Pollution Study (RAPS) data base, conducted by EPA, were analyzed to determine an optimum set of air-quality and meteorological variables for predicting maximum ozone levels for each day in 1976. A 'leaps and bounds' regression analysis was used to identify the best subset of variables. Three particular variables, the 9 a.m. ozone level, the forecasted maximum temperature, and the 6-9 a.m. averaged wind speed, have useful forecasting utility. The trajectory history of air masses entering St. Louis was studied, and it was concluded that transport-related variables contribute to the appearance of very high ozone levels. The final empirical forecast model predicts the daily maximum ozone over 341 days with a standard deviation of 11 ppb, which approaches the estimated error.

Prior, E. J.↗

Atmospheric carbon dioxide and chlorofluoromethanes - Combined effects on stratospheric ozone, temperature, and surface temperature

The effects of combined CO2 and CFCl3 and CF2Cl2 time-dependent scenarios on atmospheric O3 and temperature are described; the steady-state levels of O3 and surface temperature, to which the chlorofluoromethane scenario tends in the presence of twice and four time ambient CO2, are examined; and surface temperature changes, caused by the combined effects, are established. A description of the model and of the experiments is presented. Results indicate that (1) the total ozone time history is significantly different from that due to the chlorofluoromethane alone; (2) a local ozone minimum occurs in the upper stratosphere about 45 years from the present with a subsequent ozone increase, then decline; and (3) steady-state solutions indicate that tropospheric temperature and water vapor increases, associated with increased infrared opacity, cause significant changes in tropospheric ozone levels for 2 x CO2 and 4 x CO2, without the addition of chlorofluoromethanes.

Callis, L. B.↗

Calibration of a mass spectrometer experiment for ozone

A system with which to calibrate a stratospheric mass spectrometer experiment for ozone has been developed and evaluated. The stability of ozone and the formation of impurities within the calibration volume were measured. The half-life of ozone is about 12 hours, its purity ranges from 95% to 99% and is known to within 1%. The total calibration accuracy of the mass spectrometer experiment for ozone is about + or - 2%.

Anderson, S.↗

Measurement of heavy ozone in the stratosphere

The distribution of heavy ozone (molecular mass 50) has been measured for the first time in the stratosphere with a mass spectrometer system. During a balloon descent after midnight on September 4, 1980, a pronounced enhancement of heavy ozone was found. The maximum in the isotopic ratio, (O-18)(O-16)2/(O-16)3, occurred at 32 km where the enhancement of heavy ozone was over 40%. The ratio decreased toward higher and lower altitudes, and reached the standard value below 24 km. These measurements confirm an earlier prediction that there exists a preferred production mechanism for heavy ozone in the stratosphere.

Mauersberger, K.↗

Ozone Trend Detectability

The detection of anthropogenic disturbances in the Earth's ozone layer was studied. Two topics were addressed: (1) the level at which a trend in total ozoning is detected by existing data sources; and (2) empirical evidence in the prediction of the depletion in total ozone. Error sources are identified. The predictability of climatological series, whether empirical models can be trusted, and how errors in the Dobson total ozone data impact trend detectability, are discussed.

Campbell, J. W.↗

Atmospheric ozone profiles from high resolution UV spectra obtained with a balloon-borne spectrometer

High resolution solar spectra at high and low sun angles are analyzed by a layer-by-layer three-wavelength differential absorption method. Ozone amounts are derived from the ratio of a low sun angle scan through a long atmosphere path to a high sun angle scan through a negligible atmosphere path. Ozone volume-mixing ratio profiles are derived and agree with standard profiles. The accuracy of the ozone profiles is found to be limited mostly by the accuracy of the ozone absorption coefficients, and suggestions are made for improving the accuracy of the results in future measurements.

Gillis, J. R.↗

Stratospheric ozone and hydroxyl radical measurements by balloon-borne lidar

An experiment is reported in which a balloon-borne lidar system was used to measure ozone and the hydroxyl radical in the stratosphere by two lidar techniques. Ozone was measured in the 20-37 km altitude range using differential absorption lidar, and the hydroxyl radical was measured in the 34-37 km range using remote laser-induced fluorescence. Ozone concentrations were determined with a vertical resolution of 0.5 km, and in addition, horizontally resolved ozone measurements with 0.15-km resolution were obtained over a 2-km range. The temporal variation of the hydroxyl radical concentration ranged from 40 parts/trillion shortly after noon to about 5 parts/trillion two hours after sunset. Possible modifications to the system are discussed which can yield an improvement in the sensitivity of between one and two orders of magnitude, thus permitting measurements of the hydroxyl radical in the 20-30-km altitude range.

Heaps, W. S.↗

An airborne lidar system for ozone and aerosol profiling in the troposphere and lower stratosphere

A description is presented of an airborne UV optical radar (lidar) system, taking into account also the first range-resolved ozone measurements from an aircraft using the differential absorption lidar (Dial) technique. The discussed system is the first to use an aircraft platform for ozone profile measurements. The Dial technique determines the average gas concentration over some selected range interval. The airborne Dial system uses two high conversion efficiency dye lasers which are optically pumped by two frequency-doubled Nd:YAG lasers. The first remote measurements of ozone profiles with an airborne Dial system were made during flight tests between May 22 and June 6, 1980. The UV Dial system was operated at a nominal altitude of 3.2 km. Initial measurements of ozone and aerosol profiles with the Dial system were performed on 4 flights in the vicinity of the Chesapeake Bay.

Browell, E. V.↗

A procedure for estimating the information content of SBUV ozone profiles

A description is presented of a new procedure for determining ozone mixing ratios in the upper stratosphere from satellite observations of backscattered ultraviolet (SBUV) radiance. The employed approach is based on a SBUV inversion procedure. The inversion algorithm can best be described as a series of sequentially performed operations, taking into account the determination of a first guess profile, the representation of the ozone profile by a polynomial, the extension of the profile outside the measurement region, error assessment, the optimal ozone profile, and the utilization of iteration. It is found that the described ozone profiling algorithm can be implemented with sufficient computational speed to be used operationally for the inversion of SBUV data.

Cunnold, D. M.↗

Satellite profile measurements of stratospheric ozone

A description is presented of preliminary results obtained in connection with the Stratospheric Aerosol and Gas Experiment (SAGE). SAGE, which uses a limb scanning solar radiometer, is an experiment aboard the Applications Explorer Mission 2 spacecraft which was launched on February 18, 1979. The instrument utilizes the technique of solar occultation to measure limb-path atmospheric extinction profiles which are inverted to yield vertical profiles of various atmospheric constituents in the latitude range from 79 deg South to 79 deg North. The ozone spectral channel is centered at 0.60 micrometers in the middle of the Chappuis absorption band. The general characteristics of the ozone profile measurements are shown in a graph. Each profile represents a day's average of approximately 15 measurements at the latitude band indicated. The SAGE ozone measurements are generating a highly detailed picture of the stratospheric ozone distribution.

Mccormick, M. P.↗

A preliminary assessment of the problems in the use of interference filter photometers to determine total ozone

In the spring of 1979 an investigation was started involving the intercomparison of five ground based instruments designed to measure total ozone. The instruments considered include the Dobson spectrometer, the Russian M-83 ozonometer, the Brewer Ozone Spectrophotometer, the New Zealand (Canterbury) filter photometer, and the SenTran Company filter photometer. Three of these instruments use optical filters to make spectrophotometric determinations of total atmospheric ozone. The M-83 uses glass absorption filters to isolate the ultraviolet bands used. The Canterbury and the SenTran instruments use narrow-bandpass dielectric interference filters for the same purpose. Instruments employing optical filters are very appealing since they can be made small, rugged, and relatively inexpensive. However, the results of the reported investigation show that serious problems must be resolved before any filter instrument can be considered reliable enough for the conduction of long term, meaningful ozone measurements.

Gerlach, J. C.↗

Ozone variations and radiative-photochemical damping during a stratospheric warming

Ozone variations expected in the uppermost stratosphere and mesosphere during a warming are estimated by a photochemical calculation based on temperatures measured at 40-80 km during the February 1966 warming at Fort Churchill, Canada. A simple linearized model of radiative-photochemical relaxation is then used to describe the coupled response of ozone and temperature to a specified heating due to dynamical forcing. By comparing the joint radiative-photochemical relaxation time with that for infrared emission alone shows that the ozone perturbation induced by the warming reduces the recovery time to approximately 65% of the pure radiative value near 70 km and to 90% near 50 km. Thus, the ozone changes induced by the dynamically forced temperature increases have a significant impact on the evolution of the warming.

Frederick, J. E.↗

Global pictures of the ozone field from high altitudes from DE-I

Detailed synoptic views of the column ozone field can be obtained by the Spin-Scan Ozone Imager (SOI) (Keating et al., 1981) aboard the Dynamics Explorer I satellite. The eccentric polar orbit with an apogee altitude of 23,000 km allows high resolution global-scale images to be obtained within 12 minutes, and allows regions to be viewed for long periods of time. At perigee, a pixel size of nadir measurements of 3 km is possible, and measurements are determined using the backscattered ultraviolet technique. A wavelength measurement of 317.5 nm is used as there are limitations in filter locations and it allows comparison with Nimbus 7 SBUV/TOMS data. Consideration of the reflectivities of this data aids in checking the SOI data reduction algorithm. SOI data show short-term (less than one day) variations in the observed ozone field, and a negative correlation (greater than 0.9) between ozone and tropopause heights. It is expected, due to this correlation, that SOI data will aid in understanding the time evolution of dynamics near the tropopause.

Keating, G. M.↗

Total ozone and surface temperature correlations during 1972 - 1981

Ten years of Dobson spectrophotometer total ozone measurements and surface temperature observations were used to construct monthly mean values of the two parameters. The variability of both parameters is greatest in the months of January and February. Indeed, in January there is an apparent correlation between high total ozone values and abnormally low surface temperatures. However, the correlation does not hold in February. By reviewing the history of stratospheric warmings during this period, it is argued that the ozone and surface temperature correlation is influenced by the advection or lack of advection of ozone rich arctic air resulting from sudden stratospheric warmings.

Parsons, C. L.↗

Satellite observed ozone variations and solar activity

The degree of association between total and stratospheric ozone and solar ultraviolet irradiance is evaluated based on mean monthly latitudinally averaged ozone observations from the Nimbus-4 BUV data set. The mean monthly 10.7 cm solar flux f(10.7), adjusted for varying earth-sun distance, is used as a convenient index of solar UV variation. Results show no obvious relationship between total ozone and solar ultraviolet irradiance based on analysis of satellite data over a period of seven years, even though such a relationship has been suggested from theoretical considerations. However, the analysis does indicate that there may be a positive response in the upper tropical stratosphere, at a height of about 45-50 km such that there is an increase in the ozone concentration following an increase in solar UV radiation, which is assumed to be indicated by an increase in f(10.7) flux

London, J.↗

Periodic and aperiodic ozone variations in the middle and upper stratosphere

Umkehr, ozonesonde and satellite observations are used to determine the height/latitude distribution of the amplitude and phase of the periodic components of the variation in the ozone mixing ratio in the middle and upper stratosphere. The amplitude of the first (annual) harmonic is found to be small in the subtropics and to increase to a maximum at polar latitudes. In addition, it increases with height in the mid and upper stratosphere to an apparent maximum just below the stratosphere. The second (semi-annual) harmonic possesses an amplitude that is largest in tropical regions and in subpolar regions at a level of about 40 km. Very little ozone variation is seen above 30 km with dominant periods close to the quasi-biennial period of total ozone observed in the tropics. The percentage of the total variance of the ozone mixing ratio accounted for by the first harmonic is found to be larger than 60 percent at all heights from 20 deg to 60 deg latitude in both hemispheres (except near 40 km in the Northern Hemisphere).

London, J.↗

The distribution and annual cycle of ozone in the upper stratosphere

Study of the global distribution of upper stratospheric ozone derived from backscatter ultraviolet (BUV/SBUV) instruments on the Nimbus 4 and 7 satellites reveals the following characteristics for the period June 1970 May 1972 plus portions of 1978 and 1979. At pressures less than 5 mbar a local midlatitude maximum in the ozone mixing ratio develops in autumn and persists through the winter season in both hemispheres. However, by a pressure of 10 mbar the seasonal trend has reversed, with midlatitude summer values exceeding those in winter. The largest ozone mixing ratios in a global sense occur at tropical latitudes between pressures of 7 and 9 mbar. The general character of this pattern repeats from year to year, although differences in detail exist, especially in winter. This interannual variability in ozone increases the difficulty in extracting small long-term trends from the available data base. The overall seasonal pattern revealed by the measurements is in accord with photochemical model predictions which include the annual variation in temperature and solar illumination.

Frederick, J. E.↗

Tabulations of ambient ozone data obtained by GASP (Global Air Sampling Program) airliners, March 1975 to July 1979

Tabulations are given of GASP ambient ozone mean, standard deviation, median, 84th percentile, and 98th percentile values, by month, flight level, and geographical region. These data are tabulated to conform to the temporal and spatial resolution required by FAA Advisory Circular 120-38 (monthly by 2000 ft in altitude by 5 deg in latitude) for climatological data used to show compliance with cabin ozone regulations. In addition seasonal x 10 deg latitude tabulations are included which are directly comparable to and supersede the interim GASP ambient ozone tabulations given in appendix B of FAA-EE-80-43 (NASA TM-81528). Selected probability variations are highlighted to illustrate the spatial and temporal variability of ambient ozone and to compare results from the coarse and fine grid analyses.

Jasperson, W. H.↗