Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Microbial Optical Data Processing: A Key Step in the Metabolic Assessment of Lunar Explorer Instrument for Space Biology Applications (LEIA) and Biosentinel’s Payload Data

The BioSensor payload platform on BioSentinel and LEIA autonomously collects optical data from microbial model organisms in liquid culture. The BioSensor is designed to monitor metabolic activity using absorbance measurements of cell density and alamarBlue, a readily available colorimetric redox indicator dye. BioSentinel, a pioneering NASA CubeSat, uses yeast to study deep space radiation. LEIA investigates radiation and lunar gravity response. The experimental setup includes 16 wells equipped with three LEDs (570, 630, and 850 nm) and their corresponding photodetectors. One well is a calibration control without biology while the rest have desiccated cultures. Autonomous rehydration initiates the experiment. Data from the BioSensor are received from the flight and ground units, enabling comparison to uncover location-based metabolic rate variations. This study presents a Python Jupyter notebook developed for efficient data processing of multiple CSV files containing date and time columns, temperature, and well illumination data. It offers a user-friendly interface while maintaining computational power, automatically recognizing and iteratively processing data files in a user-input path. A Hampel filter with a short window eliminates outlier artifacts from sensor dropout. Because absorbance is a relative measurement, conversion from raw illumination requires defining a “blank” value, so the first data points are averaged to provide the necessary denominator. A cube-root function correction mitigates undesired drift caused by air pockets during the fluidic card filling phase, maintaining optical path length consistency. Beer-Lambert's law is applied to further convert absorbance values to cell and dye form concentrations, the desired science parameters. The processed data are saved and visualized as SVG plots. Future plans include extracting specific science parameters from the processed data like growth rate and metabolic rate, and identification of features corresponding to metabolic and phenotypic shifts such as starvation, shifts from aerobic to anaerobic growth, and osmotic stresses.

Space biology↗

Lessons Learned From the Flight of the NASA In-Step Cryo System Experiment

The Cryo System Experiment was developed to validate in near zero-g space a 65 K cryogenic system for focal planes, optics, or other imaging instruments that require continuous cryogenic cooling. Two key cryogenic technologies, designed to improve performance of systems for scientific, commercial and defense applications in space, were successfully demonstrated on a February 1995 Shuttle mission. The two were a 2-watt 65 K long-life low- vibration Stirling cooler and a diode oxygen heat pipe thermal switch. Lessons learned are presented.

cryogenics↗

The four- and five-band multispectral scanners for Landsat

The earth resources sensing Multispectral Scanner (MSS) for the Landsat satellite has two versions; one with four spectral bands from 0.5 to 1.1 microns, and one with five bands, the added band being 10.4 to 12.6 microns. This paper describes optical design and performance. The instrument uses a flat, object-space scanning mirror of near-linear motion, with a sensitive optical position monitor to detect mirror angular position. The 22.9-cm aperture telescope images the scene on an array of fiber optics, which dissect and transmit the scene energy to photomultiplier tubes detecting in Bands 1, 2, and 3, and silicon photodiodes detecting Band 4. Band 5 energy passes the fiber optic assembly and is reimaged on a radiatively cooled mercury cadmium telluride (HgCdTe) detector. The orbiting four-band scanner is furnishing data registered to better than 50-m band-to-band and resolving 80-m repetitive pattern over a 185-km swath width from 907-km altitude.

Lansing, J. C., Jr.↗

Causes and Effects of AIRS Optics Temperature Cycles

In addition to the expected orbital thermal cycle, geophysical conditions with high thermal and reflected upwelling infrared (IR) drive measurable changes in the AIRS instrument with a period of 24 hours. Especially hot and bright scenes are important, with about 30% of the variability driven by thermal IR and 70% by reflected IR. We show how these cycles manifest in the instrument telemetry for temperatures and gain and with careful analysis can even be detected in spectral shifts.Thermal cycles are an unavoidable feature of instruments observing upwelling radiances from Earth, because the signal inherently carries varying amounts of energy into the instrument. Temperature control of the optical bench, on-board calibrator blackbody, and Focal Plane Array (FPA) in AIRS reduce the impacts of temperature variability to extremely small levels. This combined with good on-board telemetry of the temperatures and including temperature variability in our calibration algorithm has resulted in an instrument that achieves ‘climate quality’ measurements. Careful instrument and algorithm design allows us to characterize and document the impact of temperature variability and limit the effects to negligible levels, helping the instrument meet important climate-quality criteria specified in Ohring 2005

Overoye, Kenneth↗

Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation

Rocking curve topography at the Advanced Photon Source’s beamline 1-BM measures the x-ray reflection from large (many cm 2 ) flat crystals on a sub-mm scale with microradian angular resolution. The $(01\bar{1}1)$ reflection at 8 keV is uniform across the crystal and close to theory for three thick quartz wafers well-polished with increasingly finer grit. However, the reflection is non-uniform for some ~ 0.1mmthin, bendable crystals that are made flat by optical contact with a flat substrate. Here, these thin crystals are bent to serve in certain x-ray diagnostics of plasmas, and similar non-uniformities could then occur in bent crystals as well. The same detail in x-ray reflection in bent crystals is unachievable with the existing topography setup: one way to get the desired resolution is with a standard microfocusing approach.

47 OTHER INSTRUMENTATION↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Optical studies of X-ray sources with the MASCOT - A charge-coupled device /CCD/-based astronomical instrument

The performance levels achieved by the MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes) on the 1.3-m telescope at the McGraw-Hill observatory in March 1981 are discussed along with preliminary data obtained in searches for optical counterparts to four 'empty-field' X-ray sources. In the W band (4000-7000 A), the MASCOT achieved a sky-limited sensitivity of +24.4 mag per sq arcsec in an 1800 s integration. The ability to flatten pictures to a level consistent with (sky + source) photon statistics and readout noise was demonstrated. For the four sources observed, an optical counterpart was established for one source (1413+13) based on positional coincidence (better than 1.8 arcsec), four possible candidates were detected in the error box of another source (1009?35) and upper sensitivity limits were established for optical counterparts in the error boxes for the other two sources (0920+39 and 0931-11).

Ricker, G. R.↗

Reflection Effects in Multimode Fiber Systems Utilizing Laser Transmitters

A number of optical communication lines are now in use at NASA-Kennedy for the transmission of voice, computer data, and video signals. Now, all of these channels use a single carrier wavelength centered near 1300 or 1550 nm. Engineering tests in the past have given indications of the growth of systematic and random noise in the RF spectrum of a fiber network as the number of connector pairs is increased. This noise seems to occur when a laser transmitter is used instead of a LED. It has been suggested that the noise is caused by back reflections created at connector fiber interfaces. Experiments were performed to explore the effect of reflection on the transmitting laser under conditions of reflective feedback. This effort included computer integration of some of the instrumentation in the fiber optic lab using the Lab View software recently acquired by the lab group. The main goal was to interface the Anritsu Optical and RF spectrum analyzers to the MacIntosh II computer so that laser spectra and network RF spectra could be simultaneously and rapidly acquired in a form convenient for analysis. Both single and multimode fiber is installed at Kennedy. Since most are multimode, this effort concentrated on multimode systems.

Bates, Harry E.↗

Using AI for Wave-front Estimation with the Rubin Observatory Active Optics System

Abstract The Vera C. Rubin Observatory will, over a period of 10 yr, repeatedly survey the southern sky. To ensure that images generated by Rubin meet the quality requirements for precision science, the observatory will use an active-optics system (AOS) to correct for alignment and mirror surface perturbations introduced by gravity and temperature gradients in the optical system. To accomplish this, Rubin will use out-of-focus images from sensors located at the edge of the focal plane to learn and correct for perturbations to the wave front. We have designed and integrated a deep-learning (DL) model for wave-front estimation into the AOS pipeline. In this paper, we compare the performance of this DL approach to Rubin’s baseline algorithm when applied to images from two different simulations of the Rubin optical system. We show the DL approach is faster and more accurate, achieving the atmospheric error floor both for high-quality images and low-quality images with heavy blending and vignetting. Compared to the baseline algorithm, the DL model is 40× faster, the median error 2× better under ideal conditions, 5× better in the presence of vignetting by the Rubin camera, and 14× better in the presence of blending in crowded fields. In addition, the DL model surpasses the required optical quality in simulations of the AOS closed loop. This system promises to increase the survey area useful for precision science by up to 8%. We discuss how this system might be deployed when commissioning and operating Rubin.

79 ASTRONOMY AND ASTROPHYSICS↗

US Participation in the GOME and SCIAMACHY Projects

The research performed during this reporting period includes development and maintenance of scientific software for the GOME retrieval algorithms, consultation on operational software development for GOME, further sensitivity and instrument studies to help finalize the definition of the SCIAMACHY instrument, and consultation on optical and detector issues for both GOME and SCIAMACHY. The Global Ozone Monitoring Experiment was successfully launched on the ERS-2 satellite on April 20, 1995, during this reporting period, and is working in the expected fashion. The European Space Agency has made their selections from responses to the Announcement of Opportunity for GOME validation and science studies, part of the overall ERS AO. The Smithsonian Astrophysical Observatory (SAO) proposal has been selected. These proposals are primarily for access to the data; ESA does not provide research funding for the selected investigations. The SAO activities that are carried out as a result of selection by ESA are funded by the present grant, to the limit that can be accomplished at the present level of funding. SCIAMACHY is currently in Phase C/D. Instrument design is almost finalized and selection of infrared detectors from the initial production run has been made.

Chance, K. V.↗

Acousto-Optic Imaging Spectrometers for Mars Surface Science

NASA's long term plan for Mars sample collection and return requires a highly streamlined approach for spectrally characterizing a landing site, documenting the mineralogical make-up of the site and guiding the collections of samples which represent the diversity of the site. Ideally, image data should be acquired at hundreds of VIS and IR wavelengths, in order to separately distinguish numerous anticipated species, using principal component analysis and linear unmixing. Cameras with bore-sighted point spectrometers can acquire spectra of isolated scene elements, but it requires 10(exp 2) to 10(exp 2) successive motions and precise relative pointing knowledge in order to create a single data cube which qualifies as a spectral map. These and other competing science objectives have to be accomplished within very short lander/rover operational lifetime (a few sols). True, 2-D imaging spectroscopy greatly speeds up the data acquisition process, since the spectra of all pixels in the scene are collected at once. This task can be accomplished with cameras that use electronically tunable acousto-optic tunable filters (AOTFs) as the optical tuning element. AOTFs made from TeO2 are now a mature technology, and operate at wavelengths from near-UV to about 5 microns. Because of incremental improvements in the last few years, present generation devices are rugged, radiation-hard and operate at temperatures down to at least 150K so they can be safely integrated into the ambient temperature optics of in-situ instruments such as planetary or small-body landers. They have been used for ground-based astronomy, and were also baselined for the ST-4 Champollion IR comet lander experiment (CIRCLE), prior to cancellation of the ST-4 mission last year. AIMS (for Acousto-optic Imaging spectrometer), is a prototype lander instrument which is being built at GSFC with support by the NASA OSS Advanced Technologies and Mission Studies, Mars Instrument Definition and Development Program (MIDP). AIMS is capable of tunable spectroscopic imaging of surface mineralogy, ices and dust between 0.5 and 2.4 microns, at a resolving power (lambda/delta lambda) which is typically several hundred. The design spatial resolution, similar to IMP and SSI, will allow mapping at scales down to about 1 cm.

Glenar, D. A.↗

Transmission Telescope Optical Dynamic Alignment

The Integrated Radio Optical Communication System (iROC) is designed to transmit data between Mars and Earth by means of radio waves at 32.67 GHz (Ka Band) and laser beam at 1550 nm, both transmitted via a combined teletenna. The iROC terminal will provide ‘beaconless’ operations to allow full function from the outer planets. In order to point without the aid of an uplink beacon, the proof of concept presented here is addressing the need for an accurate determination and control of the relative position of the laser beam with respect to a reference star. The experiment presented simulates a surrogate transmission telescope system in laboratory setting and presents the model used in the correction of the outgoing beam. The results of the model show a nonlinear dependence between the outgoing and the reference beam, indicating the necessity of a minimum of two metrology instruments placed along the optical system for increased pointing precision.

optical communication↗

SCExAO CHARIS Direct Imaging Discovery of a 20 au Separation, Low-mass Ratio Brown Dwarf Companion to an Accelerating Sun-like Star

We present the direct imaging discovery of a substellar companion to the nearby Sun-like star, HD 33632 Aa, at a projected separation of ∼20 au, obtained with SCExAO/CHARIS integral field spectroscopy complemented by Keck/NIRC2 thermal infrared imaging. The companion, HD 33632 Ab, induces a 10.5σ astrometric acceleration on the star as detected with the Gaia and Hipparcos satellites. SCExAO/CHARIS JHK (1.1–2.4 μm) spectra and Keck/NIRC2 L(sub p) (3.78 μm) photometry are best matched by a field L/T transition object: an older, higher-gravity, and less dusty counterpart to HR 8799 cde. Combining our astrometry with Gaia/Hipparcos data and archival Lick Observatory radial velocities, we measure a dynamical mass of 46.4 ± 8 MJ and an eccentricity of e < 0.46 at 95% confidence. HD 33632 Ab’s mass and mass ratio (4.0% ± 0.7%) are comparable to the low-mass brown dwarf GJ 758 B and intermediate between the more massive brown dwarf HD 19467 B and the (near-)planet-mass companions to HR 2562 and GJ 504. Using Gaia to select for direct imaging observations with the newest extreme adaptive optics systems can reveal substellar or even planet-mass companions on solar system–like scales at an increased frequency compared to blind surveys

exoplanets↗

Wavelength-precise slit spectroscopy with optical fiber image scramblers

The application of optical-fiber image scramblers in wavelength-precise slit spectroscopy is discussed together with the design strategy for the optimal instrument configuration incorporating an optical-fiber image scrambler. Particular attention is given to the aspects of data analysis and interpretation techniques which must be specially designed for high-precision spectroscopy. In a specific application to an existing coude spectrograph, the instrumentation and data reduction techniques described in this paper demonstrate an achievable precision corresponding to a systematic radial velocity error of about 30 m/sec.

Heacox, William D.↗

Optical Temperature Sensor Has Digital Output

New instrument measures temperature reliabily and accurately. Device uses Fabry-Perot multiple-beam sensor. Both temperature sensor and optical lines are free of all electrical and electromagnetic effects and interference. Variation in spacer is made sensitive to other physical quantities, such as pressure. Sensing element itself is quite small, enhancing use in confined areas.

James, K.↗

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Sharp, high numerical aperture (NA), nanoimprinted bare pyramid probe for optical mapping

The ability to correlate optical hyperspectral mapping and high resolution topographic imaging is critically important to gain deep insight into the structure–function relationship of nanomaterial systems. Scanning near-field optical microscopy can achieve this goal, but at the cost of significant effort in probe fabrication and experimental expertise. To overcome these two limitations, we have developed a low-cost and high-throughput nanoimprinting technique to integrate a sharp pyramid structure on the end facet of a single-mode fiber that can be scanned with a simple tuning-fork technique. The nanoimprinted pyramid has two main features: (1) a large taper angle (~70°), which determines the far-field confinement at the tip, resulting in a spatial resolution of 275 nm, an effective numerical aperture of 1.06, and (2) a sharp apex with a radius of curvature of ~20 nm, which enables high resolution topographic imaging. Optical performance is demonstrated through evanescent field distribution mapping of a plasmonic nanogroove sample, followed by hyperspectral photoluminescence mapping of nanocrystals using a fiber-in-fiber-out light coupling mode. Through comparative photoluminescence mapping on 2D monolayers, we also show a threefold improvement in spatial resolution over chemically etched fibers. These results show that the bare nanoimprinted near-field probes provide simple access to spectromicroscopy correlated with high resolution topographic mapping and have the potential to advance reproducible fiber-tip-based scanning near-field microscopy.

47 OTHER INSTRUMENTATION↗

Zodiacal light dynamics experiment: A wideband imaging Fabry-Perot interferometer

The Solar Probe will provide an ideal platform from which to study dynamics of dust particles near the sun by measuring the detailed character of the Fraunhofer structure of the zodiacal light. The suggested instrument is a wideband imaging Fabry-Perot interferometer with state of the art technology in both the optics and the detector. The instrument would function as a high-resolution imaging device providing wavelength resolution of 0.03 A over about a 20 A range. The wideband imaging capability would provide sky maps of the zodiacal light on a despun spacecraft without mechanical scanning. The Solar Probe mission would allow the velocity distribution of the dust to be mapped along most of the trajectory of the spacecraft.

Torr, D. G.↗