Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Linear Approximation Line Pack Model for Integrated Electricity and Natural Gas Systems OPF

With the increasing installation of renewable energy electricity generation capacity, the penetration of natural gas fired generation is also substantailly increasing in power systems due to their fast response capability to mitigate system variability and uncertainty. The dependencies between the electricity system and the natural gas system are becoming more important to maintain the reliability of both systems. In integrated electricity and natural gas systems (IEGSs) operations, the nonlinearity of the natural gas system brings challenges to the system operators. In this paper, the IEGSs optimal power flow (OPF) model is proposed that includes the line pack of the gas system via linear approximation. The simulation results demonstrate that the proposed model can obtain optimal solutions efficiently that are comparable in accuracy as the nonlinear line pack model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practical Event Location Estimation Algorithm for Power Transmission System Based on Triangulation and Oscillation Intensity

Event location in power systems is quite essential information for system operators to enhance control-room situational awareness capability. Therefore, it is of great importance to develop an event location estimation algorithm for transmission systems with high accuracy. With the development of wide-area measurement system (WAMS) such as FNET/GridEye, and the synchrophasor measurement devices (SMDs) such as frequency disturbance recorders (FDRs), the synchronous measurement data including frequency, voltage amplitude and phase angle can be collected and used for event location estimation. First, the phase angle and rate of change of frequency (RoCoF) trajectories are respectively used for determining two sets of wave arrival time associated with each FDR. Then, a convolutional neural network (CNN) is utilized to determine the wave arrival order to select the more suitable set of wave arrival times for a given case and to perform corresponding modifications. Next, the oscillation intensity associated with each FDR is determined based on phase angle trajectories in the center of inertia (COI) coordinate system. Finally, the multiple criteria for event location estimation are represented. In conclusion, case studies and comparisons between the proposed and previous algorithms using actual and confirmed cases in U.S. power systems are performed to demonstrate the effectiveness and improvement of the proposed algorithm in practical applications.

frequency disturbance recorder (FDR)↗

Quantifying Interannual Variability for Photovoltaic Systems in PVWatts

The National Renewable Energy Laboratory's (NREL's) PVWatts is a relatively simple tool used by industry and individuals alike to easily estimate the amount of energy a photovoltaic (PV) system will produce throughout the course of a typical year. PVWatts Version 5 has previously been shown to be able to reasonably represent an operating system's output when provided with concurrent weather data, however this type of data is not available when estimating system output during future time frames. For this purpose PVWatts uses weather data from typical meteorological year (TMY) datasets which are available on the NREL website. The TMY files represent a statistically 'typical' year which by definition excludes anomalous weather patterns and as a result may not provide sufficient quantification of project risk to the financial community. It was therefore desired to quantify the interannual variability associated with TMY files in order to improve the understanding of risk associated with these projects. To begin to understand the interannual variability of a PV project, we simulated two archetypal PV system designs, which are common in the PV industry, in PVWatts using the NSRDB's 1961-1990 historical dataset. This dataset contains measured hourly weather data and spans the thirty years from 1961-1990 for 239 locations in the United States. To note, this historical dataset was used to compose the TMY2 dataset. Using the results of these simulations we computed several statistical metrics which may be of interest to the financial community and normalized the results with respect to the TMY energy prediction at each location, so that these results could be easily translated to similar systems. This report briefly describes the simulation process used and the statistical methodology employed for this project, but otherwise focuses mainly on a sample of our results. A short discussion of these results is also provided. It is our hope that this quantification of the interannual variability of PV systems will provide a starting point for variability considerations in future PV system designs and investigations. however this type of data is not available when estimating system output during future time frames.

14 SOLAR ENERGY↗

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The theory of diversity and redundancy in information system security : LDRD final report.

The goal of this research was to explore first principles associated with mixing of diverse implementations in a redundant fashion to increase the security and/or reliability of information systems. Inspired by basic results in computer science on the undecidable behavior of programs and by previous work on fault tolerance in hardware and software, we have investigated the problem and solution space for addressing potentially unknown and unknowable vulnerabilities via ensembles of implementations. We have obtained theoretical results on the degree of security and reliability benefits from particular diverse system designs, and mapped promising approaches for generating and measuring diversity. We have also empirically studied some vulnerabilities in common implementations of the Linux operating system and demonstrated the potential for diversity to mitigate these vulnerabilities. Our results provide foundational insights for further research on diversity and redundancy approaches for information systems.

99 GENERAL AND MISCELLANEOUS↗

Hydrogen generation systems utilizing sodium silicide and sodium silica gel materials

Systems, devices, and methods combine reactant materials and aqueous solutions to generate hydrogen. The reactant materials can sodium silicide or sodium silica gel. The hydrogen generation devices are used in fuels cells and other industrial applications. One system combines cooling, pumping, water storage, and other devices to sense and control reactions between reactant materials and aqueous solutions to generate hydrogen. Multiple inlets of varied placement geometries deliver aqueous solution to the reaction. The reactant materials and aqueous solution are churned to control the state of the reaction. The aqueous solution can be recycled and returned to the reaction. One system operates over a range of temperatures and pressures and includes a hydrogen separator, a heat removal mechanism, and state of reaction control devices. The systems, devices, and methods of generating hydrogen provide thermally stable solids, near-instant reaction with the aqueous solutions, and a non-toxic liquid by-product.

08 HYDROGEN↗

Hydrogen generation systems utilizing sodium silicide and sodium silica gel materials

Systems, devices, and methods combine reactant materials and aqueous solutions to generate hydrogen. The reactant materials can sodium silicide or sodium silica gel. The hydrogen generation devices are used in fuels cells and other industrial applications. One system combines cooling, pumping, water storage, and other devices to sense and control reactions between reactant materials and aqueous solutions to generate hydrogen. Multiple inlets of varied placement geometries deliver aqueous solution to the reaction. The reactant materials and aqueous solution are churned to control the state of the reaction. The aqueous solution can be recycled and returned to the reaction. One system operates over a range of temperatures and pressures and includes a hydrogen separator, a heat removal mechanism, and state of reaction control devices. The systems, devices, and methods of generating hydrogen provide thermally stable solids, near-instant reaction with the aqueous solutions, and a non-toxic liquid by-product.

08 HYDROGEN↗

A Fast and Scalable Genetic Algorithm-Based Approach for Planning of Microgrids in Distribution Networks: Preprint

As a result of climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks; thus, the level of proactive preparation of the distribution system to be able to handle severe impacts of extreme weather events represents the system's resilience. One method that distribution systems use to prepare for extreme events is to form multiple microgrids and thereby isolate themselves from the grid supply by using local generation as much as possible to supply critical loads. But partitioning an existing system into multiple feasible islands capable of supporting critical loads is still challenging for distribution systems - first, because of the size of the graph partitioning problem and, second, because of the difficulty in properly formulating the desired attributes of such islands or microgrids. Therefore, this paper presents a genetic algorithmbased approach that facilitates incorporating multiple objectives for grid partitioning by formulating two types of problems - node allocation and edge elimination - and it considers multiple topological and resilience-enhancing objectives. The performance of the proposed genetic algorithm-based approach is numerically evaluated on multiple test systems as well as on a real distribution feeder in Colorado, USA.

edge elimination↗

Assessing High-energy, Laser-driven, X-ray Sources as a Technique to Analyse ILW Containers - 18242

The principle concern regarding intermediate level waste (ILW) containers is the internal volumetric expansion due to the formation of corrosion products. To tackle this (via non-destructive testing) the development of a new technique to identify problematic containers was initiated by radiographic imaging and neutron assay of small scale, simulated, nuclear waste packages. This was achieved using a high-energy laser pulse to produce a bright burst of high-energy Bremsstrahlung radiation for imaging and a pulse of thermal energy neutrons for isotopic quantification. The small scale, simulated, nuclear waste packages (typically a quarter of a 28 mm natural uranium penny encased in grout) were produced with corrosion from oxygen and hydrogen rich environments to simulate the potential effects of long term storage. These samples were characterised using electron and ion beam techniques prior to encapsulation to establish the extent of corrosion and sample morphology. The small-scale samples were analysed using high-resolution x-ray tomography (XRT). These 3D pictures identified the corrosion state of the material and the effect on the surrounding grout matrix. These data sets were used as a baseline to compare with the 2D images obtained from the high-energy radiography to ascertain the imaging quality and potential capability of a laser driven inspection system. The study established the non-destructive imaging capability of a high-energy laser driven x-ray source for identifying fine features such as corrosion products on uranium samples encased in grout and cracks, and for penetrative imaging through large thicknesses of grout. In addition, generation of laser-driven neutrons of thermal energy required for active interrogation of uranium isotopes is demonstrated experimentally and simulations of the neutron inspection method are presented, thus paving the way for criticality testing of ILW containers. This current study is single pulse exposure acquisition, but the data can be used to predict the potential capability of a diode-pumped laser-driven system operating at, or above, 10 Hz by utilising, for example, the Dipole laser technology recently delivered by the STFC Central Laser Facility. Such a system will enable 3D tomography of nuclear waste containers and also greatly reduced signal to noise ratio via multiple acquisition and image stacking. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced modeling of $\mathrm{DER}$s and $\mathrm{UPFC}$ devices with Sparse Tableau Formulation for $\mathrm{ACOPF}$

Distributed energy resources (DERs) are projected to be significant contributors in electric power grid modernization efforts. Yet many distribution and transmission system operators are concerned about potential reliability and security impacts of high penetration of DERs, and cite the need of greater visibility and controllability of decision variables associated with these DERs. Tractable modeling of DERs in AC optimal power flow (ACOPF) is one of the barriers to their integration into the existing operation, planning and market paradigm. Similarly, as more intermittent renewable resources are deployed, power flow control becomes more valuable, and accurate representation of Flexible AC Transmission System (FACTS) devices in ACOPF will likely grow in importance. Here this paper focuses on the detailed representation of substations with the high penetration of DERs, and on the Unified Power Flow Controller (UPFC) FACTS devices, in OPF. To this end, a novel Sparse Tableau Formulation (STF) for ACOPF is used to accurately model such features as substation reconfiguration to accommodate DERs, and to represent decision variables appropriate to the voltage source converters within UPFCs. Numerical studies are provided to demonstrate the impacts of detailed DER and UPFC representations on optimal operation, and the computational efficiency.

42 ENGINEERING↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Initial Performance of Solergy's HCPV/T System at Rome-Fiumicino International Airport

A commercial HCPV/T system, developed by Solergy, is installed at the airport of Rome, in Italy, as part of a prototype smart grid. The system is rated at 15 kW AC electric and 20 kW thermal and is used to provide both electricity for charging electric vehicles and heat for a conventional thermal power plant. This paper presents an analysis of the performance of the system, operating since March 2017, which achieves a combined peak efficiency of 48%. This study incorporates also an investigation on the improvements that can benefit the system, including a new type of receiver with improved heat dissipation.

14 SOLAR ENERGY↗

Simulation of PV Variability as a Function of PV Generation and Plant Size

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear-and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute time-scale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

irradiance↗

Recommended Functionalities for Improving Cybersecurity of Distributed Energy Resources

The current electric grid is transitioning through increasing penetration of distributed energy resources (DERs), which include intermittent renewable generation resources on the distribution side. Both the monitoring and control of DERs require extensive data-exchange and communication networks. These networks lead to cyber vulnerabilities and risks of new kinds of cyberattacks that may be extremely destructive for power system operations. Although current standards, such as IEEE Std. 1547-2018, do not discuss cybersecurity measures for DERs, cybersecurity controls should be developed for securing DER systems at the device level, communications level, and applications level. This paper discusses the current industry's best practices related to DER cybersecurity and proposes recommended functionalities for improving the cybersecurity posture of DERs, specifically at the device/distribution level. These practical recommendations have been discussed and verified with the industry through a DER cybersecurity working group.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress toward a universal biomedical data translator

Clinical, biomedical, and translational science has reached an inflection point in the breadth and diversity of available data and the potential impact of such data to improve human health and well-being. However, the data are often siloed, disorganized, and not broadly accessible due to discipline-specific differences in terminology and representation. To address these challenges, the Biomedical Data Translator Consortium has developed and tested a pilot knowledge graph-based “Translator” system capable of integrating existing biomedical data sets and “translating” those data into insights intended to augment human reasoning and accelerate translational science. Having demonstrated feasibility of the Translator system, the Translator program has since moved into development, and the Translator Consortium has made significant progress in the research, design, and implementation of an operational system. Herein, we describe the current system’s architecture, performance, and quality of results. We apply Translator to several real-world use cases developed in collaboration with subject-matter experts. Finally, we discuss the scientific and technical features of Translator and compare those features to other state-of-the-art, biomedical graph-based question-answering systems.

60 APPLIED LIFE SCIENCES↗

Potential Energy Savings Due to Phase Change Material in a Building Wall Assembly: An Examination of Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗