Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICAL ACTIVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Synthesis, phase composition modification, and optical properties of Ce{sup 3+}/Tb{sup 3+} activated KGdF{sub 4} and GdF{sub 3} submicrocrystals

Ce{sup 3+}/Tb{sup 3+} co-doped series of samples have been synthesized based on a citric acid assisted hydrothermal method. By controlling the hydrothermal treating time, the samples evolve from the Ce{sup 3+}/Tb{sup 3+} co-doped cubic phase KGdF{sub 4} with spherical morphology into the Ce{sup 3+}/Tb{sup 3+} co-doped orthorhombic phase GdF{sub 3} with rhombic shape finally. The X-ray diffraction data illustrate the phase composition modification process of the samples. The field emission scanning electron microscopy and the transmission electron microscopy images suggest the transformation in the morphology of final products. The spectra of the energy-dispersive spectroscopy reveal the constituents of the samples. And the selected area electronic diffraction patterns prove the crystalline phases of the samples. Based on previous studies and the experimental data, one possible phase composition modification process has been summarized. The photoluminescence excitation and emission spectra and the luminescent dynamic decay curves demonstrate the variations in optical properties of the Ce{sup 3+}/Tb{sup 3+} co-doped final products. - Graphical abstract: Schematic illustration for the phase composition modification from the Ce{sup 3+}/Tb{sup 3+} doped KGdF{sub 4} to the Ce{sup 3+}/Tb{sup 3+}doped GdF{sub 3} with multiform morphologies and different sizes. (C presents cubic phase, H presents hexagonal phase, and O presents orthorhombic phase.) Highlights: Black-Right-Pointing-Pointer The samples were synthesized by a hydrothermal method. Black-Right-Pointing-Pointer The samples evolved from the cubic phase KGdF{sub 4} into the orthorhombic phase GdF{sub 3}. Black-Right-Pointing-Pointer The morphology evolved from the spherical shape into the rhombic shape finally. Black-Right-Pointing-Pointer A possible phase composition modification process was summarized. Black-Right-Pointing-Pointer The optical properties of final products were compared and studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancement of Optical Component Control for an Imaging Fabry-Perot Interferometer

Risk mitigation activities associated with a prototype imaging Fabry-Perot Interferometer (FPI) system are continuing at the NASA Langley Research Center. The system concept and technology center about enabling and improving future space-based atmospheric composition missions, with a current focus on observing tropospheric ozone around 9.6 micron, while having applicability toward measurement in different spectral regions and other applications. Recent activities have focused on improving an optical element control subsystem to enable precise and accurate positioning and control of etalon plates; this is needed to provide high system spectral fidelity critical for enabling the required ability to spectrally-resolve atmospheric line structure. The latest results pertaining to methodology enhancements, system implementation, and laboratory characterization testing will be reported

Larar, Allen M.↗

MULTI-WAVELENGTH OBSERVATIONS OF A SAMPLE OF INTERMEDIATE-LUMINOSITY RADIO-LOUD ACTIVE GALAXIES

We present the results from exploratory (12-23 ks) XMM-Newton observations of six optically selected, radio-loud active galactic nuclei (AGNs), together with new radio data and a reanalysis of their archival SDSS spectra. The sources were selected in an effort to expand the current sample of radio-loud AGNs suitable for detailed X-ray spectroscopy studies. The sample includes three broad-line and three narrow-line sources, with X-ray luminosities of the order of L{sub 2-10keV} {approx} 10{sup 43} erg s{sup -1}. The EPIC spectra of the broad-lined sources can be described by single power laws with photon indices {Gamma} {approx} 1.6 and little to negligible absorption (N{sub H} {approx}<10{sup 21} cm{sup -2}); on the contrary, significant absorption is detected in the narrow-lined objects, N{sub H} {approx} 10{sup 23} cm{sup -2}, one of which displays a prominent (equivalent width {approx}2 keV) Fe K{alpha} emission line. Studying their location in several luminosity-luminosity diagrams for radio-loud AGNs, we find that the sources fall at the lower end of the distribution for bright, classical radio-loud AGNs and close to LINER-like sources. As such, and as indicated by the ratios of their optical emission lines, we conclude that the sources of our sample fall on the border between radiatively efficient and inefficient accretion flows. Future deeper studies of these targets at X-rays and longer wavelengths will expand our understanding of the central engines of radio-loud AGNs at a critical transition region.

79 ASTRONOMY AND ASTROPHYSICS↗

Driving energetically unfavorable dehydrogenation dynamics with plasmonics

Nanoparticle surface structure and geometry generally dictate where chemical transformations occur, with higher chemical activity at sites with lower activation energies. Here, we show how optical excitation of plasmons enables spatially modified phase transformations, activating otherwise energetically unfavorable sites. We have designed a crossed-bar Au-PdH x antenna-reactor system that localizes electromagnetic enhancement away from the innately reactive PdH x nanorod tips. Using optically coupled in situ environmental transmission electron microscopy, we track the dehydrogenation of individual antenna-reactor pairs with varying optical illumination intensity, wavelength, and hydrogen pressure. Our in situ experiments show that plasmons enable new catalytic sites, including dehydrogenation at the nanorod faces. Molecular dynamics simulations confirm that these new nucleation sites are energetically unfavorable in equilibrium and only accessible through tailored plasmonic excitation.

36 MATERIALS SCIENCE↗

RADIO SPECTRAL INDEX ANALYSIS AND CLASSES OF EJECTION IN LS I +61{sup 0}303

LS I +61{sup 0}303 is a {gamma}-ray binary with periodic radio outbursts coincident with the orbital period of P = 26.5 days. The origin of the radio emission is unclear, it could be due either to a jet, as in microquasars, or to the shock boundary between the Be star and a possible pulsar wind. We here analyze the radio spectral index over 6.7 years from Green Bank Interferometer data at 2.2 GHz and 8.3 GHz. We find two new characteristics in the radio emission. The first characteristic is that the periodic outbursts indeed consist of two consecutive outbursts; the first outburst is optically thick, whereas the second outburst is optically thin. The spectrum of LS I +61{sup 0}303 is well reproduced by the shock-in-jet model commonly used in the context of microquasars and active galactic nuclei: the optically thin spectrum is due to shocks caused by relativistic plasma ('transient jet') traveling through a preexisting much slower steady flow ('steady jet'). This steady flow is responsible for the preceding optically thick spectrum. The second characteristic we find is that the observed spectral evolution, from optically thick to optically thin emission, occurs twice during the orbital period. We observed this occurrence at the orbital phase of the main 26.5 d outburst and also at an earlier phase, shifted by {delta}{phi}{approx} 0.3 (i.e., almost 8 d before). We show that this result qualitatively and quantitatively agrees with the two-peak accretion/ejection model proposed in the past for LS I +61{sup 0}303. We conclude that the radio emission in LS I +61{sup 0}303 originates from a jet and suggest that the variable TeV emission comes from the usual Compton losses expected as an important by-product in the shock-in-jet theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Towed Subsurface Optical Communications Buoy

The innovation allows critical, high-bandwidth submarine communications at speed and depth. This reported innovation is a subsurface optical communications buoy, with active neutral buoyancy and streamlined flow surface veins for depth control. This novel subsurface positioning for the towed communications buoy enables substantial reduction in water-absorption and increased optical transmission by eliminating the intervening water absorption and dispersion, as well as by reducing or eliminating the beam spread and the pulse spreading that is associated with submarine-launched optical beams.

Stirbl, Robert C.↗

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

SU-E-T-506: Intercomparison Study On Small Field Output Factor Measurements

Purpose In radiotherapy, uncertainties due to small field measurements (SFM) introduce systematic errors to the treatment process and the development of new dosimeters for quality assurance programs is a challenge. In this work we analyze the behavior of seven detectors measuring output factors of 6MV photon beam. Methods The dosimeters employed are: a single cristal diamond detector (SCCD) developed at the University of Rome Tor Vergata, a silicon diode developed within the project MAESTRO, a IBA Razor silicon diode, A1SL and A26 Exradin ion chambers, an EBT3 Gafchromic film and the Exradin W1 Scintillator.Diamond sensitive volume is a cylinder 2.2mm in diameter and 1μm thick. MAESTRO diode is 2×2mm2 active area. Razor sensitive volume is a cylinder 0.6 mm in diameter and 0.02 mm thick. A16 and A1Sl have a collecting volume of 0,015cc and 0,053cc. The W1 is an optical fiber with an active volume of 0.002cc. All measurements were performed in a water phantom, with detector positioned at the isocenter (SSD=90cm, d=10cm), MAESTRO diode being sandwiched in solid water to obtain an equivalent experimental setup. Results These measurements are challenging due to the absence of charged particle equilibrium conditions, detector size and positioning problems. They are in good agreement among each other, especially GAF, Razor, W1 and SCDD. Maximum deviations reported are related to the field 0.8×0.8cm2 for MAESTRO and chambers data with respect to EBT3: around 15% (A1SLvsEBT3), 16% (MAESTROvsEBT3). Razor and W1 show a deviation around 3% with respect to SCDD. Conclusion In this work measurements made with a variety of detectors are compared. These study show the possibility to choose different detectors for SFM and that smaller ion chambers are still not competitive with solid state detectors. Silicon, diamond and optical fiber dosimeters show a similar behavior with minor discrepancies for the smallest field.

60 APPLIED LIFE SCIENCES↗

Evidence for an Optical Low-Frequency Quasi-Periodic Oscillation in the Kepler Light Curve of an Active Galaxy

We report evidence for a quasi-periodic oscillation (QPO) in the optical light curve of KIC 9650712, a narrow-line Seyfert 1 galaxy in the original Kepler field. After the development and application of a pipeline for Kepler data specific to active galactic nuclei (AGNs), one of our sample of 21 AGNs selected by infrared photometry and X-ray flux demonstrates a peak in the power spectrum at log ν = −6.58 Hz, corresponding to a temporal period of t = 44 days. We note that although the power spectrum is well fit by a model consisting of a Lorentzian and a single power law, alternative continuum models cannot be ruled out. From optical spectroscopy, we measure the black hole mass of this AGN as log (M(sub BH)/solar mass) = 8.17. We find that this frequency lies along a correlation between low-frequency QPOs and black hole mass from stellar and intermediate mass black holes to AGNs, similar to the known correlation in high-frequency QPOs.

quasi-periodic oscillation (QPO)↗

HST/ACS IMAGING OF OMEGA CENTAURI: OPTICAL COUNTERPARTS OF CHANDRA X-RAY SOURCES

We present results of a search for optical counterparts of X-ray sources in and toward the globular cluster Omega Centauri (NGC 5139) using the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope. The ACS data consist of a mosaic of Wide Field Channel images obtained using F625W, F435W, and F658N filters; with nine pointings we cover the central {approx}10' Multiplication-Sign 10' of the cluster and encompass 109 known Chandra sources. We find promising optical counterparts for 59 of the sources, {approx}40 of which are likely to be associated with the cluster. These include 27 candidate cataclysmic variables (CVs), 24 of which are reported here for the first time. Fourteen of the CV candidates are very faint, with absolute magnitudes in the range M {sub 625} =10.4-12.6, making them comparable in brightness to field CVs near the period minimum discovered in the Sloan Digital Sky Survey. Additional optical counterparts include three BY Dra candidates, a possible blue straggler, and a previously reported quiescent low-mass X-ray binary. We also identify 3 foreground stars and 11 probable active galactic nuclei. Finally, we report the discovery of a group of seven stars whose X-ray properties are suggestive of magnetically active binaries, and whose optical counterparts lie on or very near the metal-rich anomalous giant and subgiant branches in {omega} Cen. If the apparent association between these seven stars and the RGB/SGB-a stars is real, then the frequency of X-ray sources in this metal-rich population is enhanced by a factor of at least five relative to the other giant and subgiant populations in the cluster. If these stars are not members of the metal-rich population, then they bring the total number of red stragglers (also known as sub-subgiants) that have been identified in {omega} to Cen 20, the largest number yet known in any globular cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Condensation Nuclei Particle Counter (CCN) Instrument Handbook

The Cloud Condensation Nuclei Counter—CCN (Figure 1) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility instrument for measuring the concentration of aerosol particles that can act as cloud condensation nuclei [1, 2]. The CCN draws the sample aerosol through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in this process, are counted (and sized) by an Optical Particle Counter (OPC). Thus, activated ambient aerosol particle number concentration as a function of supersaturation is measured. Models CCN-100 and CCN-200 differ only in the number of humidifier columns and related subsystems: CCN-100 has one column and CCN-200 has two columns along with dual flow systems and electronics.

54 ENVIRONMENTAL SCIENCES↗

Optical Method of Measuring the Temperature of Fluoride Crystals Activated by Yb{sup 3+} and Tm{sup 3+} Ions

The fluorescence intensities ratio (FIR) method is applied for measuring the temperature inside the luminescent LiY{sub 0.8}Yb{sub 0.2}F{sub 4}:Tm{sup 3+} crystal. The obtained results are used for monitoring of the sample temperature in the experiment when the exciting radiation waist is shifted by the focusing lens inside the sample. It is shown that a considerable change in the luminescence intensity of the LiY{sub 0.8}Yb{sub 0.2}F{sub 4}:Tm{sup 3+} crystal (0.2%) is not accompanied by a significant change in the temperature. This verifies the hypothesis about the appearance of amplified spontaneous luminescence (ASL) of Yb{sup 3+} ions during intense laser pumping in these crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Active vibration control using a modal-domain fiber optic sensor

A closed-loop control experiment is described in which vibrations of a cantilevered beam are suppressed using measurements from a modal-domain fiber optic sensor. Modal-domain sensors are interference between the modes of a few-mode optical waveguide to detect strain. The fiber is bonded along the length of the beam and provides a measurement related to the strain distribution on the surface of the beam. A model for the fiber optic sensor is derived, and this model is integrated with the dynamic model of the beam. A piezoelectric actuator is also bonded to the beam and used to provide control forces. Control forces are obtained through dynamic compensation of the signal from the fiber optic sensor. The compensator is implemented with a real-time digital controller. Analytical models are verified by comparing simulations to experimental results for both open-loop and closed-loop configurations.

Cox, David E.↗

Active In-Flight Load Redistribution Utilizing Fiber-Optic Shape Sensing and Multiple Control Surfaces

Morphing wing technologies have gained research interest in recent years as technological advancements pave the way for such innovations. A key benefit of such a morphing wing concept is the ability of the wing to transition into an optimal configuration at multiple flight conditions. Such a morphing wing will have applications not only in drag reduction but also in flutter suppression and gust alleviation. By manipulating the wing geometry to match a given flight profile it is likely that the wing will yield increases in not just aerodynamic efficiency but also structural efficiency. These structurally efficient designs will likely rely on some type of structural sensing system which will ensure the wing maintains positive margins throughout its flight profile.

FOSS↗

Investigation of solar active regions at high resolution by balloon flights of the solar optical universal polarimeter, extended definition phase

Technical studies of the feasibility of balloon flights of the former Spacelab instrument, the Solar Optical Universal Polarimeter, with a modern charge-coupled device (CCD) camera, to study the structure and evolution of solar active regions at high resolution, are reviewed. In particular, different CCD cameras were used at ground-based solar observatories with the SOUP filter, to evaluate their performance and collect high resolution images. High resolution movies of the photosphere and chromosphere were successfully obtained using four different CCD cameras. Some of this data was collected in coordinated observations with the Yohkoh satellite during May-July, 1992, and they are being analyzed scientifically along with simultaneous X-ray observations.

Tarbell, Theodore D.↗