Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

X-ray Conversion Efficiency of high-Z hohlraum wall materials for indirect drive ignition

We measure the conversion efficiency of 351 nm laser light to soft x-rays (0.1-5 keV) for Au, U and high Z mixtures 'cocktails' used for hohlraum wall materials in indirect drive ICF. We use spherical targets in a direct drive geometry, flattop laser pulses and laser smoothing with phase plates to achieve constant and uniform laser intensities of 10{sup 14} and 10{sup 15} W/cm{sup 2} over the target surface that are relevant for the future ignition experiments on NIF. The absolute time and spectrally-resolved radiation flux is measured with a multichannel soft x-ray power diagnostic. The conversion efficiency is then calculated by dividing the measured x-ray power by the incident laser power from which the measured laser backscattering losses is subtracted. After {approx}0.5 ns, the time resolved x-ray conversion efficiency reaches a slowly increasing plateau of 95% at 10{sup 14} W/cm{sup 2} laser intensity and of 80% at 10{sup 15} W/cm{sup 2}. The M-band flux (2-5 keV) is negligible at 10{sup 14} W/cm{sup 2} reaching {approx}1% of the total x-ray flux for all target materials. In contrast, the M-band flux is significant and depends on the target material at 10{sup 15} W/cm{sup 2} laser intensity, reaching values between 10% of the total flux for U and 27% for Au. Our LASNEX simulations show good agreement in conversion efficiency and radiated spectra with data when using XSN atomic physics model and a flux limiter of 0.15, but they underestimate the generated M-band flux.

42 ENGINEERING↗

High-resolution 17-75 keV backlighters for high energy density experiments

17-75 keV one- and two-dimensional high-resolution (<10 {mu}m) radiography has been developed using high-intensity short pulse lasers. High energy K{alpha} sources are created by fluorescence from hot electrons interacting in the target material after irradiation by lasers with intensity I{sub L}>10{sup 17} W/cm{sup 2}. High-resolution point projection one- and two-dimensional radiography has been achieved using microfoil and microwire targets attached to low-Z substrate materials. The microwire size was 10 {mu}mx10 {mu}mx300 {mu}m on a 300 {mu}mx300 {mu}mx5 {mu}m polystyrene substrate. The radiography experiments were performed using the Titan laser at Lawrence Livermore National Laboratory. The results show that the resolution is dominated by the microwire target size and there is very little degradation from the plasma plume, implying that the high-energy x-ray photons are generated mostly within the microwire volume. There are enough K{alpha} photons created with a 300 J, 1-{omega}, 40 ps pulse laser from these small volume targets, and that the signal-to-noise ratio is sufficiently high, for single shot radiography experiments. This unique technique will be used on future high energy density experiments at many new high-power laser facilities.

07 ISOTOPE AND RADIATION SOURCES↗

TRIDENT high-energy-density facility experimental capabilities and diagnostics

The newly upgraded TRIDENT high-energy-density (HED) facility provides high-energy short-pulse laser-matter interactions with powers in excess of 200 TW and energies greater than 120 J. In addition, TRIDENT retains two long-pulse (nanoseconds to microseconds) beams that are available for simultaneous use in either the same experiment or a separate one. The facility's flexibility is enhanced by the presence of two separate target chambers with a third undergoing commissioning. This capability allows the experimental configuration to be optimized by choosing the chamber with the most advantageous geometry and features. The TRIDENT facility also provides a wide range of standard instruments including optical, x-ray, and particle diagnostics. In addition, one chamber has a 10 in. manipulator allowing OMEGA and National Ignition Facility (NIF) diagnostics to be prototyped and calibrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ray-Based Calculations of Backscatter in Laser Fusion Targets

A steady-state model for Brillouin and Raman backscatter along a laser ray path is presented. The daughter plasma waves are treated in the strong damping limit, and have amplitudes given by the (linear) kinetic response to the ponderomotive drive. Pump depletion, inverse-bremsstrahlung damping, bremsstrahlung emission, Thomson scattering off density fluctuations, and whole-beam focusing are included. The numerical code deplete, which implements this model, is described. The model is compared with traditional linear gain calculations, as well as 'plane-wave' simulations with the paraxial propagation code pf3d. Comparisons with Brillouin-scattering experiments at the OMEGA Laser Facility [T. R. Boehly et al., Opt. Commun. 133, p. 495 (1997)] show that laser speckles greatly enhance the reflectivity over the deplete results. An approximate upper bound on this enhancement, motivated by phase conjugation, is given by doubling the deplete coupling coefficient. Analysis with deplete of an ignition design for the National Ignition Facility (NIF) [J. A. Paisner, E. M. Campbell, and W. J. Hogan, Fusion Technol. 26, p. 755 (1994)], with a peak radiation temperature of 285 eV, shows encouragingly low reflectivity. Doubling the coupling to bound the speckle enhancement suggests a less optimistic picture. Re-absorption of Raman light is seen to be significant in this design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse shaping and energy storage capabilities of angularly multiplexed KrF laser fusion drivers

This paper describes a rep-rated multibeam KrF laser driver design for the 500 kJ Inertial Fusion test Facility (FTF) recently proposed by NRL, then models its optical pulse shaping capabilities using the ORESTES laser kinetics code. It describes a stable and reliable iteration technique for calculating the required precompensated input pulse shape that will achieve the desired output shape, even when the amplifiers are heavily saturated. It also describes how this precompensation technique could be experimentally implemented in real time on a reprated laser system. The simulations show that this multibeam system can achieve a high fidelity pulse shaping capability, even for a high gain shock ignition pulse whose final spike requires output intensities much higher than the approx4 MW/cm{sup 2} saturation levels associated with quasi-cw operation; i.e., they show that KrF can act as a storage medium even for pulsewidths of approx1 ns. For the chosen pulse, which gives a predicted fusion energy gain of approx120, the simulations predict the FTF can deliver a total on-target energy of 428 kJ, a peak spike power of 385 TW, and amplified spontaneous emission prepulse contrast ratios I{sub ASE}/I<3x10{sup -7} in intensity and F{sub ASE}/F<1.5x10{sup -5} in fluence. Finally, the paper proposes a front-end pulse shaping technique that combines an optical Kerr gate with cw 248 nm light and a 1 mum control beam shaped by advanced fiber optic technology, such as the one used in the National Ignition Facility (NIF) laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of the recently proposed super-Marx generator approach to thermonuclear ignition with the deuterium-tritium laser fusion-fission hybrid concept by the Lawrence Livermore National Laboratory

The recently proposed super-Marx generator pure deuterium microdetonation ignition concept is compared to the Lawrence Livermore National Ignition Facility (NIF) Laser deuterium-tritium fusion-fission hybrid concept (LIFE). In a super-Marx generator, a large number of ordinary Marx generators charge up a much larger second stage ultrahigh voltage Marx generator from which for the ignition of a pure deuterium microexplosion an intense GeV ion beam can be extracted. Typical examples of the LIFE concept are a fusion gain of 30 and a fission gain of 10, making up a total gain of 300, with about ten times more energy released into fission as compared to fusion. This means the substantial release of fission products, as in fissionless pure fission reactors. In the super-Marx approach for the ignition of pure deuterium microdetonation, a gain of the same magnitude can, in theory, be reached. If feasible, the super-Marx generator deuterium ignition approach would make lasers obsolete as a means for the ignition of thermonuclear microexplosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing high areal-density cryogenic deuterium-tritium implosions using downscattered neutron spectra measured by the magnetic recoil spectrometer

For the first time high areal-density (rhoR) cryogenic deuterium-tritium (DT) implosions have been probed using downscattered neutron spectra measured with the magnetic recoil spectrometer (MRS) [J. A. Frenje et al., Rev. Sci. Instrum. 79, 10E502 (2008)], recently installed and commissioned on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The rhoR data obtained with the MRS have been essential for understanding how the fuel is assembled and for guiding the cryogenic program at the Laboratory for Laser Energetics (LLE) to rhoR values up to approx300 mg/cm{sup 2}. The rhoR data obtained from well-established charged particle spectrometry techniques [C. K. Li et al., Phys. Plasmas 8, 4902 (2001)] were used to authenticate the MRS data for low-rhoR plastic capsule implosions, and the rhoR values inferred from these techniques are in excellent agreement, indicating that the MRS technique provides high-fidelity data. Recent OMEGA-MRS data and Monte Carlo simulations have shown that the MRS on the NIF [G. H. Miller et al., Nucl. Fusion 44, S228 (2004)] will meet most of the absolute and relative requirements for determining rhoR, ion temperature (T{sub i}) and neutron yield (Y{sub n}) in both low-yield, tritium-rich, deuterium-lean, hydrogen-doped implosions and high-yield DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FISSION NEUTRON IRRADIATION EFFECT ON INTERLAMINAR SHEAR STRENGTH OF CYANATE ESTER RESIN GFRP AT RT AND 77 K

A glass fiber reinforced plastic (GFRP) with cyanate ester resin was fabricated and neutron irradiation tests up to 1x10{sup 22} n/m{sup 2} of fast neutron with over 0.1 MeV energy were carried out in fission reactor. The fabrication process of cyanate ester GFRP was established and a collaboration network to perform investigations on irradiation effect of superconducting magnet materials was constructed. Three kinds of samples were fabricated. The first was CTD403 GFRP made by NIFS, the second was (cyanate ester+epoxy) GFRP provided by Toshiba, and the last was CTD403 GFRP made by Toshiba. The irradiation was carried out at JRR-3 in Japan Atomic Energy Agency using Rabbit capsules.After the irradiation, short beam tests were conducted at room temperature and 77 K and interlaminar shear strength (ILSS) was evaluated. The irradiation of 1x10{sup 21} n/m{sup 2} increased ILSS a little but 1x10{sup 22} n/m{sup 2} irradiation decreased ILSS to around 50 MPa. These tendencies were observed in all three kinds of GFRPs.

36 MATERIALS SCIENCE↗

Multi-keV x-ray source development experiments on the National Ignition Facility

We report results from a five shot campaign carried out with Ar-Xe gas-filled targets at the National Ignition Facility (NIF). The targets were shot with {approx_equal}350 kJ of 3{omega} laser energy delivered with a 5 ns trapezoidal laser pulse. We report measured x-ray output from the target in different spectral bands both below and above 1.5 keV photon energies: We find yields of {approx_equal}20.5 kJ/sr with peak x-ray power approaching 4 TW/sr over all energies, as measured for the unique viewing angle of our detector, and {approx_equal}3.6 kJ/sr with peak x-ray power of 1 TW/sr for x-rays with energies >3 keV. This is a laser-to-x-ray conversion efficiency of 13{+-}1.3% for isotropic x-rays with energies >3 keV. Laser energy reflected by the target plasma for both inner and outer-cone beams is measured and found to be small, between 1% and 4% of the drive energy. The energy emitted in hard x-rays (with energies >25 keV) is measured and found to be {approx_equal}1 J/sr. Two-dimensional imaging of the target plasma during the laser pulse confirms a fast, volumetric heating of the entire target, resulting in efficient laser-to-x-ray conversion. Postshot simulations with a two-dimensional radiation-hydrodynamics code reproduce well the observed x-ray flux and fluence, backscattered light, and bulk target motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asymmetrically cut crystal pair as x-ray magnifier for imaging at high intensity laser facilities

The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.

36 MATERIALS SCIENCE↗

Development of a short duration backlit pinhole for radiography on the National Ignition Facility

Experiments on the National Ignition Facility (NIF) will require bright, short duration, near-monochromatic x-ray backlighters for radiographic diagnosis of many high-energy density systems. This paper details a vanadium pinhole backlighter producing (1.8{+-}0.5)x10{sup 15} x-ray photons into 4{pi} sr near the vanadium He-like characteristic x-ray energy of 5.18 keV. The x-ray yield was quantified from a set of Ross filters imaged to a calibrated image plate, with the Dante diagnostic used to confirm the quasimonochromatic nature of the spectrum produced. Additionally, an x-ray film image shows a source-limited image resolution of 26 {mu}m from a 20 {mu}m diameter pinhole.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical Properties Of Eu{sub 3}Ba{sub 2}Mn{sub 2}Cu{sub 2}O{sub 12}

The physical properties of the manganocuprate compound, Eu{sub 3}Ba{sub 2}Mn{sub 2}Cu{sub 2}O{sub 12}(Eu-3222) are investigated using X-ray diffraction, resistivity, magnetization and dielectric measurements. The structure of the Eu-3222 compound is made by the intermixing of Eu-123 (oxygen deficient triple perovskite block) and Eu-214 (K{sub 2}NiF{sub 4} type single rock-salt like block). Electrical resistivity data show insulating behavior down to the measurable temperature and exhibits a conduction mechanism which can be explained on the basis of 3D variable range hopping model. Magnetization data shows a antiferromagnetic behavior at 5 K, however without any clear signature of magnetic ordering in the temperature range 5-300 K. Dielectric (Capacitance), measured as a function of temperature at various frequencies exhibits frequency dependence, indicating glassy relaxation of dipole moments.

36 MATERIALS SCIENCE↗

Tuning indirect-drive implosions using cone power balance

We demonstrate indirect-drive implosion symmetry tuning in a vacuum hohlraum 6.6 mm in length and 3.56 mm in diameter with a CH capsule 6.38 {mu}m in thickness and 1414 {mu}m in diameter, scaled roughly 0.7 x from a National ignition facility (NIF) [E. Moses and C. R. Wuest, Fusion Sci. Technol. 47, 314 (2005)] The hohlraums have radiation drives of 117 {+-} 4 eV relevant to conditions for the first {approx}1 ns of ignition experiments. By varying the relative ratio of the energy between inner and outer beam cones illuminating the hohlraum at OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. the shape of the x-ray self-emission, and hence the shape of the emitting object, can be tuned from prolate to oblate. The second-order Legendre coefficient, used to characterize the shape, changes from a negative to a positive value at the time of peak x-ray emission during the implosion through the variation of the cone power balance. With the appropriate selection of the cone power balance, the implosion can be tuned to produce a spherical implosion. Using capsules with thicker walls, this technique can be extended to measure the drive symmetry at later times as the length of the drive pulse is increased [N. M. Hoffman et al., J. Phys.: Conf. Ser. 112, 022075 (2008); N. M. Hoffman et al., Phys. Plasmas 3, 2022 (1996)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics

The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat a l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Changes in CR-39 proton sensitivity due to prolonged exposure to high vacuums relevant to the National Ignition Facility and OMEGA

When used at facilities like OMEGA and the NIF, CR-39 is exposed to high vacuum environments before and after irradiation by charged particles and neutrons. Using an electrostatic linear accelerator at MIT, studies have been conducted to investigate the effects of high vacuum exposure on the sensitivity of CR-39 to fusion protons in the {approx}1-9 MeV energy range. High vacuum conditions, of order 10{sup -5} Torr, experienced by CR-39 samples at these facilities were emulated. It is shown that vacuum exposure times longer than {approx}16 h before proton irradiation result in a decrease in proton sensitivity, whereas no effect was observed for up to 67 h of vacuum exposure after proton irradiation. CR-39 sensitivity curves are presented for samples with prolonged exposure to high vacuum before and after proton irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of H atoms in a negative ion source plasma with the non-equilibrium electron energy distribution function

In negative ion sources for the neutral beam injection, it is important to calculate H atom flux onto the plasma grid (PG) surface for the evaluation of H{sup -} production on the PG surface. We have developed a neutral (H{sub 2} molecules and H atoms) transport code. In the present study, the neutral transport code is applied to the analysis of the H{sub 2} and H transport in a NIFS-R and D ion source in order to calculate the flux onto the PG surface. Taking into account non-equilibrium feature of the electron energy distribution function (EEDF), i.e., the fast electron component, we have done the neutral transport simulation. The results suggest that the precise evaluation of the EEDF, especially in the energy range 15 eV < E < 30 eV is important for the dissociation rate of H{sub 2} molecules by the electron impact collision and the resultant H atom flux on the PG.

43 PARTICLE ACCELERATORS↗

Using high-intensity laser-generated energetic protons to radiograph directly driven implosions

The recent development of petawatt-class lasers with kilojoule-picosecond pulses, such as OMEGA EP [L. Waxer et al., Opt. Photonics News 16, 30 (2005)], provides a new diagnostic capability to study inertial-confinement-fusion (ICF) and high-energy-density (HED) plasmas. Specifically, petawatt OMEGA EP pulses have been used to backlight OMEGA implosions with energetic proton beams generated through the target normal sheath acceleration (TNSA) mechanism. This allows time-resolved studies of the mass distribution and electromagnetic field structures in ICF and HED plasmas. This principle has been previously demonstrated using Vulcan to backlight six-beam implosions [A. J. Mackinnon et al., Phys. Rev. Lett. 97, 045001 (2006)]. The TNSA proton backlighter offers better spatial and temporal resolution but poorer spatial uniformity and energy resolution than previous D{sup 3}He fusion-based techniques [C. Li et al., Rev. Sci. Instrum. 77, 10E725 (2006)]. A target and the experimental design technique to mitigate potential problems in using TNSA backlighting to study full-energy implosions is discussed. The first proton radiographs of 60-beam spherical OMEGA implosions using the techniques discussed in this paper are presented. Sample radiographs and suggestions for troubleshooting failed radiography shots using TNSA backlighting are given, and future applications of this technique at OMEGA and the NIF are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗