Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Denoising diffusion probabilistic models for generative alloy design

Inverse material design is an extremely challenging optimization task made difficult by, in part, the highly nonlinear relationship linking performance with composition. Quantitative approaches have improved significantly owing to advances in high throughput experimentation and computational thermodynamics. However, existing physics-based tools are mostly forward models; input a chemistry and obtain a prediction. More recently the materials community has leveraged advances in the machine learning community to establish novel inverse design frameworks. Very recently denoising diffusion probabilistic models have been shown to be extremely powerful generators producing synthetic data of various modalities e.g. images, text, audio, tables, etc.. In this work a novel framework for alloy design and optimization is proposed leveraging these class of models. Five key generative tasks are demonstrated (1) unconditional generation (2) composition conditioned generation (3) property conditioned generation (4) multi-feedstock conditioned generation and (5) generative optimization. These methods were tested on three case studies: high entropy alloy design, superalloy binder jet additive manufacturing, and in-situ dual-feedstock wire-arc additive manufacturing. Results indicate that the established models are extremely flexible, expressive, and robust. The architecture’s flexibility and training procedure empower the model to learn complex intra-compositional and composition-property relationships. Furthermore, the probabilistic nature of these models makes them well suited for addressing solution non-uniqueness and tackling uncertainty quantification tasks. While the fidelity and quantity of the underlying training data is paramount, we envision that future alloy design frameworks will make extensive use of these kinds of machine learning models as “search” tools bolstering the utility of experimental and computational approaches.

36 MATERIALS SCIENCE↗

Active damping of modal vibrations by force apportioning

The theory and numerical simulation of active structural damping is described which requires few discrete control thrusters positioned on the structure. A particular apportioning of coherently phased control forces is applied for each vibration mode which is to be damped; this strongly affects the damped vibration mode, while minimally exciting all other modes. The force apportioning used is that which would tune a target mode if the structure was being shaken in a model vibration test. In contrast to model testing, the forces are varied temporally so as to dampen, rather than excite, the target mode(s).

Hallauer, W. L., Jr.↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

TH-CD-BRA-02: 3D Remote Dosimetry for MRI-Guided Radiation Therapy: A Hybrid Approach

Purpose: To validate the dosimetric accuracy of a commercially available MR-IGRT system using a combination of 3D dosimetry measurements (with PRESAGE(R) radiochromic plastic and optical-CT readout) and an in-house developed GPU-accelerated PENELOPE Monte-Carlo dose calculation system. Methods: {sup 60}Co IMRT subject to a 0.35T lateral magnetic field has recently been commissioned in our institution following AAPM’s TG-119 recommendations. We performed PRESAGE(R) sensitivity studies in 4ml cuvettes to verify linearity, MR-compatibility, and energy-independence. Using 10cm diameter PRESAGE(R), we delivered an open calibration field to examine the percent depth dose and a symmetrical 3-field plan with three adjacent regions of varying dose to determine uniformity within the dosimeter under a magnetic field. After initial testing, TG-119 plans were created in the TPS and then delivered to 14.5cm 2kg PRESAGE(R) dosimeters. Dose readout was performed via optical-CT at a second institution specializing in remote 3D dosimetry. Absolute dose was measured using an IBA CC01 ion chamber and the institution standard patient-specific QA methods were used to validate plan delivery. Calculated TG-119 plans were then compared with an independent Monte Carlo dose calculation (gPENELOPE). Results: PRESAGE(R) responds linearly (R{sup 2}=0.9996) to {sup 60}Co irradiation, in the presence of a 0.35T magnetic field, with a sensitivity of 0.0305(±0.003)cm{sup −1}Gy{sup −1}, within 1% of a 6MV non-MR linac irradiation (R{sup 2}=0.9991) with a sensitivity of 0.0302(±0.003)cm{sup −1}Gy{sup −1}. Analysis of TG-119 clinical plans using 3D-gamma (3%/3mm, 10% threshold) give passing rates of: HN 99.1%, prostate 98.0%, C-shape 90.8%, and multi-target 98.5%. The TPS agreed with gPENELOPE with a mean gamma passing rate of 98.4±1.5% (2%/2mm) with the z-score distributions following a standard normal distribution. Conclusion: We demonstrate for the first time that 3D remote dosimetry using both experimental and computational methods is a feasible and reliable approach to commissioning MR-IMRT, which is particularly useful for less specialized clinics in adopting this new treatment modality.

60 APPLIED LIFE SCIENCES↗

Comparison of 2 Common Radiation Therapy Techniques for Definitive Treatment of Small Cell Lung Cancer

Purpose: Two choices are widely used for radiation delivery, 3-dimensional conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT). No randomized comparisons have been conducted in the setting of lung cancer, but theoretical concerns suggest that IMRT may negatively impact disease control. We analyzed a large cohort of limited-stage small-cell lung cancer (LS-SCLC) patients treated before and after institutional conversion from 3DCRT to IMRT to compare outcomes. Methods and Materials: Patients with LS-SCLC treated with definitive radiation at our institution between 2000 and 2009 were retrospectively reviewed. Both multivariable Cox regression and propensity score matching were used to compare oncologic outcomes of 3DCRT and IMRT in the context of other clinically relevant covariables. Acute and chronic toxicities associated with the 2 techniques were compared using Fisher exact and log–rank tests, respectively. Results: A total of 223 patients were treated during the study period, with 119 receiving 3DCRT and 104 receiving IMRT. Their median age was 64 years (range, 39-90 years). Median follow-up times for 3DCRT and IMRT were 27 months (range, 2-147 months) and 22 months (range, 4-83 months), respectively. Radiation modality was not associated with differences in overall survival or disease-free survival in either multivariable or propensity score-matched analyses. IMRT patients required significantly fewer percutaneous feeding tube placements (5% vs 17%, respectively, P=.005). Conclusions: IMRT was not associated with worse oncologic outcomes than those of 3DCRT. IMRT was associated with a lower rate of esophagitis-related percutaneous feeding tube placements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The tracer-BHR4 model for subgrid mixing layers

A model for the passive evolution of turbulent subgrid-scale mixing layers is developed based on the model of tracer-BHR model of Braun & Gore. The new model, tracer-BHR4, mainly differs from the previous iteration in that it aims to replicate the behavior of BHR4, instead of BHR3.1. The coefficients from BHR4 are used and a new model for mixing layer growth is developed to allow the tracer model to reproduce the de-mixing behavior seen in BHR4. Additionally, an improved timestep size controller is introduced. The new model is tested on problems containing Rayleigh-Taylor or Richtmyer-Meshkov mixing layers, and is able to reproduce the behavior of well resolved BHR4 simulations with reasonable accuracy.

97 MATHEMATICS AND COMPUTING↗

Real-time open-loop frequency response analysis of flight test data

A technique has been developed to compare the open-loop frequency response of a flight test aircraft real time with linear analysis predictions. The result is direct feedback to the flight control systems engineer on the validity of predictions and adds confidence for proceeding with envelope expansion. Further, gain and phase margins can be tracked for trends in a manner similar to the techniques used by structural dynamics engineers in tracking structural modal damping.

Bosworth, J. T.↗

Vibration testing of impact-damaged composite laminates

A new test is described that can be used to measure changes in the vibration properties of impact damaged composite materials. Impact-induced delamination was observed to significantly affect natural frequencies of vibration and damping properties in cross-ply graphite/epoxy laminates. Natural frequencies are shown to drop by as much as half of their original value, and modal damping ratios can increase by a factor of up to eight when large amounts of damage are present. A simple finite element model of the damaged impact specimens was used to predict the effect of delamination on certain vibration properties. A comparison of the finite element calculations with the experimental measurements suggests that delamination was the dominant mechanism of flexural stiffness loss resulting from the transverse impact.

Grady, Joseph E.↗

Vibration testing of impact-damaged composite laminates

A new test is described that can be used to measure changes in vibration properties of impact-damaged composite materials. Impact-induced delamination was observed to significantly affect natural frequencies of vibration and damping properties in cross-ply graphite/epoxy laminates. Natural frequencies are shown to drop by as much as half of their original value and modal damping ratios can increase by a factor of up to eight when large amounts of damage are present. A simple finite element model of the damaged impact specimens was used to predict the effect of delamination on certain vibration properties. Comparison of the finite element calculations with the experimental measurements suggests that delamination was the dominant mechanism of flexural stiffness loss resulting from the transverse impact.

Grady, J. E.↗

Parameter identification of a rotor supported in a pressurized bearing lubricated with water

A rig for testing an externally pressurized (hydrostatic), water-lubricated bearing was developed. Applying a nonsynchronous sweep frequency, rotating perturbation force with a constant amplitude as an input, rotor vibration response data was acquired in Bode and Dynamic Stiffness formats. Using this data, the parameters of the rotor/bearing system were identified. The rotor/bearing model was represented by the generalized (modal) parameters of the first lateral mode, with the rotational character of the fluid force taken into account.

Grant, John W.↗

Active Noise Control of Low Speed Fan Rotor-Stator Modes

This report describes the Active Noise Cancellation System designed by General Electric and tested in the NASA Lewis Research Center's 48 inch Active Noise Control Fan. The goal of this study was to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for active noise cancellation of fan tones. The control system is based on a modal control approach. A known acoustic mode propagating in the fan duct is cancelled using an array of flush-mounted compact sound sources. Controller inputs are signals from a shaft encoder and a microphone array which senses the residual acoustic mode in the duct. The canceling modal signal is generated by a modal controller. The key results are that the (6,0) mode was completely eliminated at 920 Hz and substantially reduced elsewhere. The total tone power was reduced 9.4 dB. Farfield 2BPF SPL reductions of 13 dB were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB modal PWL decrease. Global attenuation of PWL was obtained using an actuator and sensor system totally contained within the duct.

Sutliff, Daniel L.↗

The Effects of Comorbidity and Age on RTOG Study Enrollment in Stage III Non-Small Cell Lung Cancer Patients Who Are Eligible for RTOG Studies

Purpose: To determine the influence of measured comorbidity in Radiation Therapy Oncology Group (RTOG) combined modality therapy (CMT) study enrollment in Stage III non-small cell lung cancer (NSCLC). Methods and Materials: One hundred and seventy-one patients with a Karnofsky Performance Score {>=}70 and clinical Stage III NSCLC were analyzed retrospectively for comorbidity, RTOG study eligibility, and enrollment at initial consultation. Effect of comorbidity scores (Cumulative Illness Rating Scale) were tested on patient selection for CMT, RTOG enrollment, and overall survival. Results: Comorbidity (Grade 4; p < 0.005) and use of radiation only (p {<=} 0.001) were associated with inferior survival independent of other factors. Patient selection for CMT was affected by age ({>=}70, p < 0.001), comorbidity (severity index [SI]> 2, p = 0.001), and weight loss (>5%, p = 0.001). Thirty-three patients (19%) were enrolled in a CMT RTOG study (Group 1). Forty-nine patients (29%) were eligible but not enrolled (Group 2), and 57 (33%) were ineligible (Group 3). The most common ineligibility reasons were weight loss (67%) and comorbidity in the exclusion criteria of the RTOG studies (63%). Group 1 patients were the youngest (p = 0.02), with the lowest comorbidity scores (p < 0.001) and SI (p < 0.001) compared with Groups 2 and 3. Group 3 patients were the oldest with the most unfavorable comorbidity profile. Comorbidity scores (SI >2; p = 0.006) and age ({>=}70; p = 0.05) were independent factors influencing RTOG study enrollment in patients meeting study eligibility requirements (Groups 1 and 2). Conclusions: Comorbidity scales could be useful in stratification of patients in advanced lung cancer trials and interpretation of results particularly regarding the elderly population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

Final Scientific/Technical Report for "Nanite" for Better Well-Bore Integrity and Zonal Isolation

Nanite™ is a cementitious material that contains a proprietary formulation of functionalized nanomaterial additive to transform conventional cement into a smart material responsive to pressure (or stress), temperature, and any intrinsic changes in composition. This project has identified optimal sensing modalities of smart well cement and demonstrated how real-time sensing of Nanite™ can improve long-term wellbore integrity and zonal isolation in shale gas and applicable oil and gas operations. Oceanit has explored Nanite’s electrical sensing properties in depth and has advanced the technology from laboratory proof-of-concept to sub-scale testing in preparation for field trials.

36 MATERIALS SCIENCE↗

Structural damage identification using mathematical optimization techniques

An identification procedure is proposed to identify damage characteristics (location and size of the damage) from dynamic measurements. This procedure was based on minimization of the mean-square measure of difference between measurement data (natural frequencies and mode shapes) and the corresponding predictions obtained from the computational model. The procedure is tested for simulated damage in the form of stiffness changes in a simple fixed free spring mass system and symmetric cracks in a simply supported Bernoulli Euler beam. It is shown that when all the mode information is used in the identification procedure it is possible to uniquely determine the damage properties. Without knowing the complete set of modal information, a restricted region in the initial data space has been found for realistic and convergent solution from the identification process.

Shen, Mo-How Herman↗

Effect of Manufacturing-Induced Defects on Reliability of Composite Wind Turbine Blades

In support of DOE's efforts on developing affordable, reliable domestic wind power, this ARRA project brought together a strong, complementary team from academia (University of Massachusetts Lowell), two DOE laboratories (NREL and Sandia), and a major wind turbine blade manufacturer (TPI) to address one of the key issues affecting wind power cost and reliability manufacturing-induced defects in the blades. The complexity of this problem required the assembled team's expertise in materials specifically textile and composite structures finite element modeling, composites manufacturing, mechanical characterization, structural dynamics, nondestructive inspection (NDI) and structural health monitoring (SHM), sensors, and wind turbine blade testing. This final report summarizes the results of this project.

17 WIND ENERGY↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗