Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

An Accurate, Error-Tolerant, and Energy-Efficient Neural Network Inference Engine Based on SONOS Analog Memory

In this work, we demonstrate SONOS (silicon-oxide-nitrideoxide- silicon) analog memory arrays that are optimized for neural network inference. The devices are fabricated in a 40nm process and operated in the subthreshold regime for in-memory matrix multiplication. Subthreshold operation enables low conductances to be implemented with low error, which matches the typical weight distribution of neural networks, which is heavily skewed toward near-zero values. This leads to high accuracy in the presence of programming errors and process variations. We simulate the end-to-end neural network inference accuracy, accounting for the measured programming error, read noise, and retention loss in a fabricated SONOS array. Evaluated on the ImageNet dataset using ResNet50, the accuracy using a SONOS system is within 2.16% of floating-point accuracy without any retraining. The unique error properties and high On/Off ratio of the SONOS device allow scaling to large arrays without bit slicing, and enable an inference architecture that achieves 20 TOPS/W on ResNet50, a >10× gain in energy efficiency over state-of-the-art digital and analog inference accelerators.

97 MATHEMATICS AND COMPUTING↗

Complementary information between UV and IR for remote sensing of total ozone

When infrared and ultraviolet measurements are available simultaneously with the same field of view, it is possible to minimize some of the errors in measuring the total ozone. The addition of the infrared technique to Total Ozone Mapping Spectrometer (TOMS) operation can aid in getting measurements of ozone in the nighttime and during the polar night. A radiometer with a channel in the window region around 11 microns, a channel in the 9-6 micron O sub 3 band, and three channels in the 15 micron CO sub 2 band should be adequate to retrieve total ozone. Such a radiometer could be designed to do cross track scanning. This combination of ultraviolet and infrared instruments could be flown on a geostationary or polar orbiting satellite.

Cuddapah, Prabhakara↗

A New Electromagnetic Instrument for Thickness Gauging of Conductive Materials

Eddy current techniques are widely used to measure the thickness of electrically conducting materials. The approach, however, requires an extensive set of calibration standards and can be quite time consuming to set up and perform. Recently, an electromagnetic sensor was developed which eliminates the need for impedance measurements. The ability to monitor the magnitude of a voltage output independent of the phase enables the use of extremely simple instrumentation. Using this new sensor a portable hand-held instrument was developed. The device makes single point measurements of the thickness of nonferromagnetic conductive materials. The technique utilized by this instrument requires calibration with two samples of known thicknesses that are representative of the upper and lower thickness values to be measured. The accuracy of the instrument depends upon the calibration range, with a larger range giving a larger error. The measured thicknesses are typically within 2-3% of the calibration range (the difference between the thin and thick sample) of their actual values. In this paper the design, operational and performance characteristics of the instrument along with a detailed description of the thickness gauging algorithm used in the device are presented.

Fulton, J. P.↗

Reliability and Validity of Ultrasound Cross Sectional Area Measurements for Long-Duration Spaceflight

Limb muscle atrophy and the accompanying decline in function can adversely affect the performance of astronauts during mission-related activities and upon re-ambulation in a gravitational environment. Previous characterization of space flight-induced muscle atrophy has been performed using pre and post flight magnetic resonance imaging (MRI). In addition to being costly and time consuming, MRI is an impractical methodology for assessing in-flight changes in muscle size. Given the mobility of ultrasound (US) equipment, it may be more feasible to evaluate changes in muscle size using this technique. PURPOSE: To examine the reliability and validity of using a customized template to acquire panoramic ultrasound (US) images for determining quadriceps and gastrocnemius anatomical cross sectional area (CSA). METHODS: Vastus lateralis (VL), rectus femoris (RF), medial gastrocnemius (MG), and lateral gastrocnemius (LG) CSA were assessed in 10 healthy individuals (36+/-2 yrs) using US and MRI. Panoramic US images were acquired by 2 sonographers using a customized template placed on the thigh and calf and analyzed by the same 2 sonographers (CX50 Philips). MRI images of the leg were acquired while subjects were supine in a 1.5T scanner (Signa Horizon LX, General Electric) and were analyzed by 3 trained investigators. The average of the 2 US and 3 MRI values were used for validity analysis. RESULTS: High inter-experimenter reliability was found for both the US template and MRI analysis as coefficients of variation across muscles ranged from 2.4 to 4.1% and 2.8 to 3.8%, respectively. Significant correlations were found between US and MRI CSA measures (VL, r = 0.85; RF, r = 0.60; MG, r = 0.86; LG, r = 0.73; p < 0.05). Furthermore, the standard error of measurement between US and MRI ranged from 0.91 to 2.09 sq cm with high limits of agreement analyzed by Bland-Altman plots. However, there were significant differences between absolute values of MRI and US for all muscles. CONCLUSION: The present results indicate that utilizing a customized US template provides reliable measures of leg muscle CSA, and thus could be used to characterize changes in muscle CSA both in flight and on the ground.

Scott, Jessica M.↗

Aircraft altitude determination using multipath information in an angle-measuring navigation satellite system

In an angle-measuring navigation satellite system using a pair of crossed interferometers located on a satellite in synchronous orbit, three parameters are needed to determine a user's position unambiguously. These are the phase differences between received signals which were transmitted by the two antennas on each of the two interferometers, and the user's altitude. The two phase difference measurements yield a line of possible user locations, and the addition of the altitude measurement reduces this line to a single point. A method is proposed which makes use of the navigation signals received after reflection off the earth's surface. The iterative procedure employs the arrival time difference between direct and reflected signals. Based on previous calculations of errors in measuring the electrical parameters it is concluded that, for North Atlantic coverage and specular reflection, altitude measurements can be made with a 1-sigma error of 65 meters.

Kurjan, D.↗

On the Ill-Posed Nature of Inverse Problems: An Exactly Solvable Paradigm Inverse Neutron Diffusion Problem Illustrating the Solution's Non-Computability - Paper 48

In general, a physical system and/or the result of an indirect experimental measurement are modeled mathematically in terms of: (a) A system of linear and/or nonlinear equations that relate the system's independent variables and parameters to the system's state (i.e., dependent) variables; (b) Probability distributions, moments thereof, inequality and/or equality constraints that define the range of variations of the system's parameters; (c) One or several quantities, customarily referred to as system responses (or objective functions, or indices of performance), which are computed using the mathematical model. The 'direct problem' solves the 'parameter-to-output' mapping that describes the 'cause-to-effect' relationship in the respective physical process. In practice, the model parameters and/or responses are experimentally measured quantities and are therefore subject to uncertainties. Many measurement problems are 'inverse' to the direct problem in that they seek to determine the properties of the medium (i.e., various cross sections), or the properties of the source, and/or the size of the medium on its boundaries from measurements of quantities that depend on the neutron flux (or from direct measurements of the neutron flux). In general, two problems are called inverses of one another if the formulation of each involves all or part of the solution of the other. Some authors further group such inverse problems into 'invasive', when the interior flux is accessible for measurements as opposed to 'non-invasive', in which only fluxes on the boundary of (or exterior to) the medium can be measured. Examples of inverse radiative transfer problems have been reviewed by McCormick, while examples of inverse source problems for neutron transport have been provided by Sanchez and McCormick. More recently, Bledsoe et al., have presented two methods (the Levenberg-Marquard, and 'differential evolution method') for addressing numerically inverse transport problems. However, although these works (as well as other works cited therein) mentioned the detrimental effects of 'small perturbations in the input data', none of the works published thus far on inverse problems for particle transport or diffusion actually showed explicitly the effects that uncertainties in the measured responses (e.g., detector measurements) would actually have on the 'inverse' deduction (from such measurements) of the underlying medium's properties, sources, etc. This work highlights explicitly the nature of the difficulties encountered in so-called 'inverse problems' by presenting a paradigm inverse neutron diffusion problem admitting an exact solution, in which the 'inverse problem' is to determine the medium's diffusion coefficient from flux measurements. It will be shown explicitly (analytically) that this is not possible to achieve in a unique manner, even in the absence of measurement uncertainties, unless additional error-free information is provided about the quantity to be determined (in this case, the medium's diffusion coefficient). It if further shown that, even if this additional error-free information about the diffusion coefficient to be determined is available, the unavoidable experimental measurements errors, albeit it vanishingly small, in the measured flux render the 'exact solution' useless for computational purposes, since the exact solution turns out to be a divergent series. As discussed in this paper's ENDNOTES section, the paradigm problem presented in this work also underscores the need for 'regularization', which is a qualifier indicating that the inverse problem is to be solved in some approximate manner. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of an instrument for sensing errors in a telescope wavefront

Focal plane sensors for determining the error in a telescope wavefront were investigated. The construction of three candidate test instruments and their evaluation in terms of small wavefront error aberration measurements are described. A laboratory wavefront simulator was designed and fabricated to evaluate the test instruments. The laboratory wavefront error simulator was used to evaluate three tests; a Hartmann test, a polarization shearing interferometer test, and an interferometric Zernike test.

Golden, L. J.↗

Cratering in glasses impacted by debris or micrometeorites

Mechanical strength measurements on five glasses and one glass-ceramic exposed on LDEF revealed no damage exceeding experimental limits of error. The measurement technique subjected less than 5 percent of the sample surface area to stresses above 90 percent of the failure strength. Seven micrometeorite or space debris impacts occurred at locations which were not in that portion of the sample subjected to greater than 90 percent of the applied stress. As a result of this, the impact events on the sample were not detected in the mechanical strength measurements. The physical form and structure of the impact sites was carefully examined to determine the influence of those events upon stress concentration associated with the impact and the resulting mechanical strength. The size of the impact site, insofar as it determines flaw size for fracture purposes, was examined. Surface topography of the impacts reveals that six of the seven sites display impact melting. The classical melt crater structure is surrounded by a zone of fractured glass. Residual stresses arising from shock compression and from cooling of the fused zone cannot be included in the fracture mechanics analyses based on simple flaw size measurements. Strategies for refining estimates of mechanical strength degradation by impact events are presented.

Wiedlocher, David E.↗

Effects of cable geometry and aircraft attitude on the accuracy of a magnetic leader cable system for aircraft guidance during rollout and turnoff

A theoretical analysis of a single wire magnetic leader cable system for aircraft rollout and turnoff guidance was performed to determine the errors produced by the leader cable installation geometry and aircraft attitude. It was found that errors in the measurement of lateral displacement from the cable are smaller than errors in the measurement of aircraft heading and that both errors are smallest at or near the cable.

Bundick, W. T.↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Experimental study of error sources in skin-friction balance measurements

An experimental study has been performed to determine potential error sources in skin-friction balance measurements. A floating-element balance, large enough to contain the instrumentation needed to systematically investigate these error sources has been constructed and tested in the thick turbulent boundary layer on the sidewall of a large supersonic wind tunnel. Test variables include element-to-case misalignment, gap size, and Reynolds number. The effects of these variables on the friction, lip, and normal forces have been analyzed. It was found that larger gap sizes were preferable to smaller ones; that small element recession below the surrounding test surface produced errors comparable to the same amount of protrusion above the test surface; and that normal forces on the element were, in some cases, large compared to the friction force.

Allen, J. M.↗

On the chromospheric structure of Zeta Aurigae

The chromospheric structure of Zeta Aur is analyzed on the basis of both optical and UV data. Column densities of matter along different lines of sight through the chromosphere are measured by using both Ly-alpha wings and many lines of ionized metals, and they agree to within the errors of measurement. The chromosphere is seen to extend at least one stellar radius above the K4-5 Ib-11 supergiant's surface. Excitation temperature increases with height and attains values in the range 6500-12,000 K over much of the chromosphere. Turbulence of the gas is near 20 km/s, and may increase with height. Support of the chromosphere by magnetic fields is discussed, and this is found to predict a high degree of clumping of the gas.

Eaton, Joel A.↗

Application of left- and right-looking SAR stereo to depth measurements of the Ammavaru outflow channel, Lada Terra, Venus

Venusian channels are too narrow to be resolved by Magellan's radar altimeter, so they are not visible in the standard topographic data products. Stereo image data, in addition to their benefit to geologic mapping of Venus structures as a whole, are indispensible in measuring the topography across the channels. These measurements can then be used in conjunction with the regional topographic maps based on the altimeter data to produce cross-sectional areas for the channels and estimate the fluid discharge through them. As an example of the application of the stereo image data to venusian channels, a number of test depth and profile measurements were made of the large outflow channel system in Lada Terra, centered at 50 deg S latitude, 21 deg E longitude (F-MIDR 50S021). These measurements were made by viewing the cycle 1 and 2 digital FMIDRs in stereo on a display monitor, so as to minimize the errors in measuring parallax displacement as much as possible. The MIDRs are produced at a scale of 75 m/pixel. This corresponds to a vertical scale of about 17 m/pixel, when calculating the height of a feature from its parallax displacement. An error in placement determination of 1 pixel was assumed to characterize the vertical accuracy as plus or minus 17 m. When this technique was applied to the outflow channel, it was noted that the walls of the collapsed terrain source and 'trough reach' of the channel are laid over in both the cycle 1 and 2 images. This is evident when examining the distance between features on the plateau and the cliff walls in the two images. The layover 'shifts' the features closer to the apparent edge of the wall relative to the oppositely illuminated image.

Parker, T. J.↗

Retrievals of Aerosol Optical and Microphysical Properties from Imaging Polar Nephelometer Scattering Measurements

A method for the retrieval of aerosol optical and microphysical properties from in situ light-scattering measurements is presented and the results are compared with existing measurement techniques. The Generalized Retrieval of Aerosol and Surface Properties (GRASP) is applied to airborne and laboratory measurements made by a novel polar nephelometer. This instrument, the Polarized Imaging Nephelometer (PI-Neph), is capable of making high-accuracy field measurements of phase function and degree of linear polarization, at three visible wavelengths, over a wide angular range of 3 to 177°. The resulting retrieval produces particle size distributions (PSDs) that agree, within experimental error, with measurements made by commercial optical particle counters (OPCs). Additionally, the retrieved real part of the refractive index is generally found to be within the predicted error of 0.02 from the expected values for three species of humidified salt particles, with a refractive index that is well established. The airborne measurements used in this work were made aboard the NASA DC-8 aircraft during the Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) field campaign, and the inversion of this data represents the first aerosol retrievals of airborne polar nephelometer data. The results provide confidence in the real refractive index product, as well as in the retrieval's ability to accurately determine PSD, without assumptions about refractive index that are required by the majority of OPCs.

Espinosa, W. Reed↗

MO-D-213-05: Sensitivity of Routine IMRT QA Metrics to Couch and Collimator Rotations

Purpose: To assess the sensitivity of gamma index and other IMRT QA metrics to couch and collimator rotations. Methods: Two brain IMRT plans with couch and/or collimator rotations in one or more of the fields were evaluated using the IBA MatriXX ion chamber array and its associated software (OmniPro-I’mRT). The plans were subjected to routine QA by 1) Creating a composite planar dose in the treatment planning system (TPS) with the couch/collimator rotations and 2) Creating the planar dose after “zeroing” the rotations. Plan deliveries to MatriXX were performed with all rotations set to zero on a Varian 21ex linear accelerator. This in effect created TPS-created planar doses with an induced rotation error. Point dose measurements for the delivered plans were also performed in a solid water phantom. Results: The IMRT QA of the plans with couch and collimator rotations showed clear discrepancies in the planar dose and 2D dose profile overlays. The gamma analysis, however, did pass with the criteria of 3%/3mm (for 95% of the points), albeit with a lower percentage pass rate, when one or two of the fields had a rotation. Similar results were obtained with tighter criteria of 2%/2mm. Other QA metrics such as percentage difference or distance-to-agreement (DTA) histograms produced similar results. The point dose measurements did not obviously indicate the error due to location of dose measurement (on the central axis) and the size of the ion chamber used (0.6 cc). Conclusion: Relying on Gamma analysis, percentage difference, or DTA to determine the passing of an IMRT QA may miss critical errors in the plan delivery due to couch/collimator rotations. A combination of analyses for composite QA plans, or per-beam analysis, would detect these errors.

60 APPLIED LIFE SCIENCES↗

Correcting For Seed-Particle Lag In LV Measurements

Two experiments conducted to evaluate effects of sizes of seed particles on errors in LV measurements of mean flows. Both theoretical and conventional experimental methods used to evaluate errors. First experiment focused on measurement of decelerating stagnation streamline of low-speed flow around circular cylinder with two-dimensional afterbody. Second performed in transonic flow and involved measurement of decelerating stagnation streamline of hemisphere with cylindrical afterbody. Concluded, mean-quantity LV measurements subject to large errors directly attributable to sizes of particles. Predictions of particle-response theory showed good agreement with experimental results, indicating velocity-error-correction technique used in study viable for increasing accuracy of laser velocimetry measurements. Technique simple and useful in any research facility in which flow velocities measured.

Jones, Gregory S.↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗