Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

THREE YEARS OF FERMI GBM EARTH OCCULTATION MONITORING: OBSERVATIONS OF HARD X-RAY/SOFT GAMMA-RAY SOURCES

The Gamma-ray Burst Monitor (GBM) on board Fermi has been providing continuous data to the astronomical community since 2008 August 12. In this paper, we present the results of the analysis of the first three years of these continuous data using the Earth occultation technique to monitor a catalog of 209 sources. From this catalog, we detect 99 sources, including 40 low-mass X-ray binary/neutron star systems, 31 high-mass X-ray binary/neutron star systems, 12 black hole binaries, 12 active galaxies, and 2 other sources, plus the Crab Nebula, and the Sun. Nine of these sources are detected in the 100-300 keV band, including seven black hole binaries, the active galaxy Cen A, and the Crab. The Crab and Cyg X-1 are also detected in the 300-500 keV band. GBM provides complementary data to other sky-monitors below 100 keV and is the only all-sky monitor above 100 keV. Up-to-date light curves for all of the catalog sources can be found online.

79 ASTRONOMY AND ASTROPHYSICS↗

Monitoring techniques and alarm procedures for CMS services and sites in WLCG

The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS, the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

Molina-Perez, J.↗

In situ laser reflectivity to monitor and control the nucleation and growth of atomically thin 2D materials*

The growth of atomically thin two-dimensional (2D) layered and other quantum materials is typically performed without in situ monitoring or control. Here, a simple laser reflectivity approach is demonstrated to provide in situ control over sub-monolayer thickness and growth kinetics during pulsed laser deposition (PLD) of MoSe 2 layers. First, the general technique is presented with emphasis on designing the maximum sensitivity of the optical contrast through consideration of Fresnel's equations with proper choice of layer thickness, substrate, and laser monitoring wavelength, incidence angle, and laser polarization. Then the 632.8 nm optical reflectivity of MoSe 2 layers on SiO 2 /Si substrates was predicted and compared with in situ monitoring of MoSe 2 growth by PLD under actual growth conditions using a probe HeNe laser beam. The measurements showed high sensitivity and excellent agreement with MoSe 2 surface coverages calculated from atomic resolution STEM analysis of 2D layers deposited in arrested growth experiments. Finally, growth kinetics revealed by these measurements showed sigmoidal nucleation and growth stages in the formation of the 2D MoSe 2 layers that are described by a simple model, indicating the promise of the laser reflectivity technique for in situ monitoring and control of 2D materials deposition.

2D materials↗

Detection of very-high-energy gamma-ray transients with monitoring facilities

ABSTRACT The observation of very-high-energy γ-rays (VHE γ-rays, $E \gt 100\,$ GeV) has ledto the identification of extremely energetic processes and particle-acceleration sites both within our Galaxy and beyond. It is expected that VHE facilities, such as the Cherenkov Telescope Array, will explore these sources with an unprecedented level of detail. However, the transient and unpredictable nature of many important processes means that their observation requires the development of proper monitoring strategies. In this study, we estimate the properties of VHE transients that can be effectively detected by monitoring facilities. We use data collected by the Fermi-LAT instrument during its monitoring campaign to select events that are probably associated with VHE emission. We use this sample to estimate the frequency, the luminosity and the time-scales of various transients, focusing on blazar flares and gamma-ray bursts. We discuss how the balance between the field of view, sensitivity and duty cycle of an observatory affects the likelihood of detecting transients that occur at the inferred rates, and we conclude by describing the contribution that current and near-future monitoring facilities can make to the identification and study of VHE transient emission.

La Mura, G.↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mesh Network Design for Smart Charging Infrastructure and Electric Vehicle Remote Monitoring

Plug-In Electric Vehicle (PEV) charging today happens with little knowledge of the state of the vehicle being charged. In order to implement smart charging algorithms and other capabilities of the future smart grid, provisions for remote PEV monitoring will have to be developed and tested. The UCLA Smart-grid Energy Research Center (SMERC) is working on a smart charging research platform that includes data acquired in real time from PEVs being charged in order to investigate smart charging algorithms and demand response (DR) strategies for PEVs in large parking garage settings. The system outlined in this work allows PEVs to be remotely monitored throughout the charging process by a smart-charging controller communicating through a mesh network of charging stations and in-vehicle monitoring devices. The approach may be used for Vehicle to Grid (V2G) communication as well as PEV monitoring.

Shepelev, Aleksey↗

ROAM: A Remotely Operated Accelerator Monitor

Monitoring accelerators in operation is a well known challenge due to the radiation environment. However, there are significant benefits in being able to deploy particular sensors in specific locations of accelerator enclosures for monitoring or troubleshooting purposes. Learning from experience at other labs, we used Commercial Off The Shelf (COTS) components and an open source robot control software framework (ROS) to build a remotely controlled robot platform including a standard suite of instruments such as cameras, LIDAR, and ultrasound, with the ability to incorporate other ad-hoc sensors for specific measurements, such as a Gamma radiation monitor. Special attention was given to the robot's ability to maintain safety in the high risk environment of an accelerator, with multiple failure contingencies in place to ensure collision free operation. Testing was performed to prove the platform's viability and showcase its capability for accelerator monitoring.

Thayer, Thomas C.↗

Dead-time optimization for SiC based voltage source converters using online condition monitoring

This paper introduces a dead-time optimization technique for a 2-level voltage source converter (VSC) using turn-off transition monitoring. Dead-time in a VSC impacts power quality, reliability, and efficiency. Silicon carbide (SiC) based VSCs are more sensitive to dead-time from increased reverse conduction losses and turn-off time variability with operating conditions and load characteristics. An online condition monitoring system for SiC devices has been developed using gate drive assist circuits and a micro-controller. It can be leveraged to monitor turn-off time and indicate the optimal dead-time in each switching cycle of any converter operation. It can also be used to specify load current polarity, which is needed for dead-time optimization in an inverter. This is an important distinction from other inverter dead-time elimination/optimization schemes as current around the zero current crossing is hard to accurately detect. A 1kW half-bridge inverter was assembled to test the turn-off time monitoring and dead-time optimization scheme. Results show 91% reduction in reverse conduction power losses in the SiC devices compared to a set dead-time of 500ns switching at 50 kHz.

Dyer, Jacob↗

Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation

Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surfacebased ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.

amendment↗

Monitoring solid metal structures with a nervous system embedded with ultrasonic 3D printing

Active and regular monitoring of structural components is a critical safety precaution, particularly as it concerns infrastructure, aerospace, industry, and many other applications. Solutions for effective structural health monitoring need to be able to probe surface and bulk properties using durable and low-power engineering. Towards these ends it is possible to build smarter, highly networked, and secure materials in order to enable remote real-time material sensing with a lesser-known form of 3D printing, ultrasonic consolidation (UC). This approach harnesses sound waves to weld metal layers in a low temperature process that does not damage sensors and electronics as they are embedded into a solid metal structure. This makes UC perfectly suited for designing solid metal parts with active embedded sensing components. However, the process parameters, material influences and mechanical factors that result in high-quality UC metal components are difficult to control or are loosely understood. The use of trial-and-error optimization during fabrication represents the chief hurdle between its current state of use and its potential to transform rapid prototyping and manufacturing of high-impact technologies (e.g., metal smart structures, wearable sensors, lab-on-a-chip, etc.). In this paper we will describe how embedded sensors may be used for in situ process monitoring and optimization. We will also discuss efforts towards standardizing UC welding for similar and dissimilar metal bonding and for embedding active sensors that can be used to create smart structures that will enable long-term structural health monitoring and other high impact applications.

Suter, Jonathan D.↗

Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three-dimensional position estimation from monoscopic imaging permits continuous, uninterrupted intrafraction motion monitoring even in the presence of gantry rotation, which may block kV sources or imagers. This potentially allows for more accurate treatment delivery, by ensuring that the prostate does not deviate substantially from the initial setup position.

60 APPLIED LIFE SCIENCES↗

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistency and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-12: Real-Time Organ Motion Monitoring Using Ultrasound and KV Fluoroscopy During Lung SBRT Delivery

Purpose: Real-time ultrasound monitoring during SBRT is advantageous in understanding and identifying motion irregularities which may cause geometric misses. In this work, we propose to utilize real-time ultrasound to track the diaphragm in conjunction with periodical kV fluoroscopy to monitor motion of tumor or landmarks during SBRT delivery. Methods: Transabdominal Ultrasound (TAUS) b-mode images were collected from 10 healthy volunteers using the Clarity Autoscan System (Elekta). The autoscan transducer, which has a center frequency of 5 MHz, was utilized for the scans. The acquired images were contoured using the Clarity Automatic Fusion and Contouring workstation software. Monitoring sessions of 5 minute length were observed and recorded. The position correlation between tumor and diaphragm could be established with periodic kV fluoroscopy periodically acquired during treatment with Elekta XVI. We acquired data using a tissue mimicking ultrasound phantom with embedded spheres placed on a motion stand using ultrasound and kV Fluoroscopy. MIM software was utilized for image fusion. Correlation of diaphragm and target motion was also validated using 4D-MRI and 4D-CBCT. Results: The diaphragm was visualized as a hyperechoic region on the TAUS b-mode images. Volunteer set-up can be adjusted such that TAUS probe will not interfere with treatment beams. A segment of the diaphragm was contoured and selected as our tracking structure. Successful monitoring sessions of the diaphragm were recorded. For some volunteers, diaphragm motion over 2 times larger than the initial motion has been observed during tracking. For the phantom study, we were able to register the 2D kV Fluoroscopy with the US images for position comparison. Conclusion: We demonstrated the feasibility of tracking the diaphragm using real-time ultrasound. Real-time tracking can help in identifying such irregularities in the respiratory motion which is correlated to tumor motion. We also showed the feasibility of acquiring 2D KV Fluoroscopy and registering the images with Ultrasound.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integrated Approach to Weather Radar Calibration and Monitoring Using Ground Clutter and Satellite Comparisons

Abstract The stability and accuracy of weather radar reflectivity calibration are imperative for quantitative applications, such as rainfall estimation, severe weather monitoring and nowcasting, and assimilation in numerical weather prediction models. Various radar calibration and monitoring techniques have been developed, but only recently have integrated approaches been proposed, that is, using different calibration techniques in combination. In this paper the following three techniques are used: 1) ground clutter monitoring, 2) comparisons with spaceborne radars, and 3) the self-consistency of polarimetric variables. These techniques are applied to a C-band polarimetric radar (CPOL) located in the Australian tropics since 1998. The ground clutter monitoring technique is applied to each radar volumetric scan and provides a means to reliably detect changes in calibration, relative to a baseline. It is remarkably stable to within a standard deviation of 0.1 dB. To obtain an absolute calibration value, CPOL observations are compared to spaceborne radars on board TRMM and GPM using a volume-matching technique. Using an iterative procedure and stable calibration periods identified by the ground echoes technique, we improve the accuracy of this technique to about 1 dB. Finally, we review the self-consistency technique and constrain its assumptions using results from the hybrid TRMM–GPM and ground echo technique. Small changes in the self-consistency parameterization can lead to 5 dB of variation in the reflectivity calibration. We find that the drop-shape model of Brandes et al. with a standard deviation of the canting angle of 12° best matches our dataset.

54 ENVIRONMENTAL SCIENCES↗

Acoustic Methods to Monitor Protein Crystallization and to Detect Protein Crystals in Suspensions of Agarose and Lipidic Cubic Phase

Improvements needed for automated crystallography include crystal detection and crystal harvesting. A technique that uses acoustic droplet ejection to harvest crystals was previously reported. Here a method is described for using the same acoustic instrument to detect protein crystals and to monitor crystal growth. Acoustic pulses were used to monitor the progress of crystallization trials and to detect the presence and location of protein crystals. Crystals were detected, and crystallization was monitored in aqueous solutions and in lipidic cubic phase. Using a commercially available acoustic instrument, crystals measuring ~150 µm or larger were readily detected. Simple laboratory techniques were used to increase the sensitivity to 50 µm by suspending the crystals away from the plastic surface of the crystallization plate. This increased the sensitivity by separating the strong signal generated by the plate bottom that can mask the signal from small protein crystals. It is possible to further boost the acoustic reflection from small crystals by reducing the wavelength of the incident sound pulse, but our current instrumentation does not allow this option. In the future, commercially available sound-emitting transducers with a characteristic frequency near 300 MHz should detect and monitor the growth of individual 3 µm crystals.

59 BASIC BIOLOGICAL SCIENCES↗

Groundwater elevation data for monitoring wells within the East and Taylor River basins, Colorado (USA)

This dataset is comprised of temporal variations in groundwater elevation data for the 24 monitoring wells located throughout the East River watershed. Seasonal to annual variations in groundwater elevations are a critical property of mountainous watersheds needed to understand both hydrological and below ground biogeochemical processes. Such data serve as a critical constraint for numerical models describing coupled groundwater-surface water behavior within the watershed. Additionally, the offset between the maximum and minimum groundwater elevations defines the extent of the bedrock weathering zone, with annual excursions in the groundwater hydrographic (i.e., the rising and falling hydrographic limbs) imposing primary controls on bedrock saturation state and redox conditions that govern biogeochemical reactions impacting nitrogen, carbon, and metals cycling. Manufacturer-specific software is used to download pressure data from each transducer, with broadly available spreadsheet software (e.g. Microsoft Excel) used to convert temporal variations in water pressure to elevations in units of meters above mean sea level. As additional monitoring wells are installed within the East River watershed and new groundwater monitoring wells are installed in the Taylor River watershed, temporal groundwater elevation data will be included as a part of this master dataset. Details regarding the metadata associated with each monitoring well location, including well depths, screened intervals, well location coordinates, and bedrock type, are included, as is a standard operating procedure for generating groundwater elevation data from water pressure values recorded by the pressure transducers. This dataset includes: (1) a zip file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.zip), containing (a) PNG of groundwater hydrographs, (b) a CSV file with groundwater elevation data, and (c) CSV file containing metadata organized by location; (2) an Excel file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.xlsx) with the groundwater elevation data, groundwater hydrographs, and metadata organized by location; (3) a Word file (Groundwater_elevation_data_protocols.docx) and a PDF file version (Groundwater_elevation_data_protocols.pdf) containing field protocols and methods; (4) a location metadata (locations.csv) file; (5) a file level metadata (flmd.csv); and (6) data dictionary (dd.csv) file.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Hadron Beam Monitor Design with Gas-Filled RF Resonators in Intense Neutrino Source

For the future Long Baseline Neutrino Facility at Fermilab, a new radiation-robust hadron beam profile monitor has been proposed consisting of an interface of gas-filled radiofrequency cavity detectors in the backward region of the LBNF decay pipe. A tailored monitor layout will be used along with the new RF instrumentation. Proposed designs for the detector configuration include a variety of radially symmetric arrangements of RF resonators located at the position of maximum gradient in the beam distribution across the monitor. Until the final detector cavities are available, a prototype tunable Q-factor RF cavity will provide functional emulation for studies of the monitor layout configurations presented here.

43 PARTICLE ACCELERATORS↗