Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MALES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Radioembolization Super Survivors: Extended Survival in Non-operative Hepatocellular Carcinoma

PurposeTo identify baseline characteristics and long-term prognostic factors in non-transplant patients with unresectable hepatocellular carcinoma (HCC) who had prolonged survival after treatment with yttrium-90 radioembolization (Y90).Materials and MethodsSixty-seven “Super Survivors” (defined as ≥ 3-year survival after Y90) were identified within our 1000-patient Y90 database (2003–2017). Baseline imaging and follow-up occurred at 1 month and every 3 months thereafter. Overall survival (OS) was calculated with Kaplan–Meier estimates with log-rank test in subgroups: Child–Pugh (CP) score, distribution of disease, portal vein thrombus (PVT), and technique (segmental vs lobar Y90).Results Median age 69.5 years (range 45–94 years); 69% male; 60% solitary HCC; 79% unilobar disease; 12% PVT; 10% ascites; Barcelona Clinic Liver Cancer Stage A—54%/B—28%/C—16%/D—2%; CP A—70%/B—28%/C—2%. Longest baseline tumor diameter was 5.4 ± 4.0 cm (mean ± SD). All patients had an imaging response (either partial or complete response). Median OS was 67.5 months (95% CI 55.2–82.5). CP score and main PVT stratified median OS (p = 0.0007 and p = 0.0187, respectively). Beyond 3 years, segmental versus lobar Y90 was associated with improved OS with a median OS of 80.2 versus 46.7 months, respectively (p = 0.0024). Dosing > 200 Gy was not a significant predictor of improved OS.ConclusionsSuper Survivors spanning the BCLC staging system maintained durable OS after radioembolization that was stratified by the extent of underlying liver disease. The common variable among all patients was an imaging response. Segmental versus lobar Y90 may have a long-term associated OS benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Postoperative Bleeding Following Abdominal Surgery

PurposeWe aimed to estimate the usefulness of transcatheter arterial embolization (TAE) in patients with postoperative abdominal hemorrhage and to evaluate the effects of pancreatic fistula on clinical outcomes and angiographic findings.Materials and MethodsWe enrolled 22 patients (20 males and 2 females; mean age 63 years; range 25–86 years), who underwent transarterial angiography for postoperative hemorrhage after abdominal surgery. This group corresponded to 28 procedures. Technical and clinical success rates were calculated, and clinical findings and outcomes were compared between patients with and without a pancreatic fistula.ResultsPre-interventional CT was performed in all patients before first angiography, and the location of the bleeding was identified in all but one patient. Active arterial bleeding, identified by extravasation of contrast agent (n = 12), pseudoaneurysm formation (n = 12), and arterial wall irregularity (n = 2) were detected in 28 angiographic procedures, and embolization was performed in 26 instances. Various embolization techniques such as isolation, packing, embolization, and stentgraft implantation were performed. The technical and clinical success rates were 96% (25/26 procedures) and 82% (18/22 patients), respectively. In hemodynamically unstable patients (shock index: heart rate/systolic blood pressure > 1), a 92% (12/13 cases) technical success rate was achieved. There were no significant differences in any evaluated parameters between patients with and without pancreatic fistula.ConclusionTAE is a safe and effective for treating postoperative hemorrhage even in patients with hemodynamic instability and pancreatic fistula. Additionally, pre-interventional CT is useful for effective, consecutive interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Wire Recanalization of Chronically Occluded Venous Stents: A Retrospective, Single-Center Experience in 15 Patients

Introduction: Chronically occluded venous stents may be difficult to salvage, necessitating multiple approaches and adjunctive techniques. Radiofrequency wires have been used to cross chronic obstructions in a variety of settings. Herein, radiofrequency wire recanalization (RFWR) of chronically occluded venous stents is presented. Materials and Methods: Fifteen patients (8 males; 7 females) aged 23–74 years (median 42 years) underwent prior venous stenting in the setting of venous occlusions. Seven had an underlying coagulopathy, three had May–Thurner syndrome, three had provoked deep venous thrombosis, one had a dialysis fistula, and one had pacer leads in situ. All indwelling venous stents were chronically occluded and symptomatic. Out of 15 patients, 13 (87%) had iliocaval venous stents, while two (13%) had superior vena cava and/or upper extremity venous stents. After failing conventional and blunt recanalization techniques, RFWR was performed to traverse the chronic occlusions. Technical success and complications were recorded. Results: Fifteen patients underwent 19 procedures. Twelve patients underwent one procedure, two patients had two procedures, and one patient had three procedures. RFWR alone was used in 12/19 (63%) procedures, while 7/19 (37%) required adjunctive sharp recanalization techniques. Technical success or crossing of the occlusion with flow restoration through the occluded segments was achieved in 17/19 (89%). One major and one minor complication occurred. Conclusion: Radiofrequency wire recanalization is an effective adjunct to revise chronically occluded venous stents, potentially increasing procedural success in challenging cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ice Ball Crack During CT-Guided Renal Cryoablation Using 1.5-mm-Diameter Cryoprobes

Ice ball fracture and massive hemorrhage are serious complications associated with renal cryoablation. When cracks occur in an ice ball, it is usually associated with adjacent renal parenchymal fracture, leading to massive hemorrhage. However, few studies have examined ice ball fracture under image-guided percutaneous renal cryoablation. We herein describe an 80-year-old male patient who had undergone CT-guided cryoablation for a left renal tumor using four cryoprobes (1.5 mm diameter each). Ice ball cracks were observed on CT images during cryoablation. However, there was no massive hemorrhage and further treatments were not necessary. This is the first report of ice ball cracks with a smaller diameter cryoprobe, which has not been considered to be associated with ice ball fracture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Percutaneous Bleomycin and Bevacizumab Sclerotherapy of Orbital Lymphatic Malformations in Children

Purpose: To evaluate the effectiveness and safety of image-guided percutaneous sclerotherapy using bleomycin for macrocystic and bevacizumab (Avastin™) for microcystic orbital lymphatic malformations in children. Materials and Methods: Between October 2015 and July 2018, we prospectively evaluated 10 pediatric patients who presented clinically and radiologically with lymphatic malformations and were treated with percutaneous sclerotherapy. Patients with venous malformations were excluded. Eight females and two males with ages ranging from 3 to 17 years (mean: 8.8, SD: 4.9) were included. Guided with ultrasound and fluoroscopy, macrocysts were treated with bleomycin instillation. For microcystic components in three patients, bevacizumab was injected intralesional. All patients underwent ultrasound and non-contrast MRI to evaluate response to treatment after 6 weeks. Results: The malformations were macrocystic in seven patients and complex (macro/microcystic) in three. Twenty sclerotherapy sessions were performed, (range: 1–3 sessions, mean: 2, SD: 0.8). Clinically, there was a significant reduction in the proptosis after treatment (P = 0.007) and dystopia (P = 0.018). The local radiological response showed a reduction in the maximum lesions diameters and volumes after treatment (P = 0.005 and 0.005, respectively). Two of the three patients treated with bevacizumab showed a reduction in the lesions volumes by 90.4% and 63.4%, respectively, whereas one patient did not show volume reduction. Transient periorbital edema and ecchymosis occurred following the procedure with no major complications encountered. Follow-up ranged from 9–33 months, mean: 20.3, SD: 7.4. Conclusion: Bleomycin sclerotherapy is a safe and effective treatment for orbital macrocystic lymphatic malformations. Further use of bevacizumab for microcystic lesions in a larger series is required to outline its efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Efficacy of Paclitaxel Drug-Eluting Balloon Angioplasty Versus Standard Balloon Angioplasty in Stenosis of Native Hemodialysis Arteriovenous Fistulas: An Analysis of Clinical Success, Primary Patency and Risk Factors for Recurrent Dysfunction

Purpose: To investigate the efficacy of paclitaxel drug-eluting balloons (PEB) versus standard balloon angioplasty (BA) in stenosis of native hemodialysis arteriovenous fistulas (AVFs). Materials and Methods: A total of 96 patients with ESRD (mean ± SD age 57.0 ± 9.1 years, 63.5% were males) who underwent endovascular treatment with PEB angioplasty (n = 32) and BA (n = 64) for a dysfunctional native AVF were included. Clinical success, complications, primary patency and postoperative recurrence parameters were recorded in each group. Results: Primary patency rate at 6 months was significantly higher in PEB than in BA group (96.9 vs. 20.3%, p < 0.001), while the two groups had similar primary patency rates at 9 months (66.8 vs. 50.0%) and 12 months (6.3% for each). No significant difference was noted between PEB and BA groups in terms of the rate (21.9% and. 31.3%), time (median 220 vs. 152.5 days) and reasons (reocclusion in 18.8 vs. 28.1%) for dysfunction recurrence as well as the number of recurrent treatments. AVF dysfunction recurrence was more likely in younger age AVF (median 4 vs. 23 months, p < 0.001 in PEB, and 8.5 vs. 20.5 months p = 0.001 in SBA) and in AVF ≤ 6 months in both SBA and PEB groups (71.4 vs. 12.0%, p = 0.005 in PEB, 40.0 vs. 2.3%, p < 0.001). Conclusion: In conclusion, our findings emphasize favorable safety and efficacy of PEB and BA in the management of dysfunctional hemodialysis AVFs with similar rates of post-PTA recurrence of AVF dysfunction. Nonetheless, there was a nonsignificant tendency for lower rate and a delay for recurrent dysfunction in patients treated with PEB and a significant association younger AVF age with an increased risk of post-PTA recurrence of AVF dysfunction. Level of Evidence: 3, Retrospective cohort study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events

Objectives: To evaluate the incidence and the time of onset of early micro-embolism after CAS (carotid artery stenting) with two different mesh-covered stents and to assess the role of DW-MRI (Diffusion-weighted magnetic resonance imaging) in their prediction. Methods: Single-institution prospective study including 50 patients (33 male, median age 74 years) who underwent CAS with Roadsaver{sup ®} or CGuard™. All patients with primary stenosis (37/50, 74%) had carotid plaque DW-MRI pre-procedure, with both qualitative evaluation of the hyperintensity and ADC (apparent diffusion coefficient) measurement of the plaque. All patients had brain DW-MRI pre-procedure, at 1 h, 24 h and 30 days post-procedure to evaluate the appearance of hyperintense lesions over time. Imaging analysis was performed in a double-blinded fashion by two radiologists. Results: There were no statistically significant differences between the two stents both in the incidence at 1 h (P = 0.23) and 24 h (P = 0.36) and in the volume of new DWI hyperintense brain lesions at 24 h (P = 0.27). Thirty-four new asymptomatic lesions in 19 patients (38%) were reported: 4 (11.8%) at 1 h, 30 (88.2%) at 24 h. The 30-day DWI-MR showed complete resolution of all lesions and no evidence of new lesion. The incidence of new lesions at 24 h resulted significantly higher in patients with DWI hyperintense carotid plaques (12/16, 75% vs. 0/21, 0%, P < 0.0001). This result was paralleled by the difference in ADC value (0.83 ± 0.21 vs. 1.42 ± 0.52). Conclusion: The majority of early asymptomatic brain lesion occurred during the first 24 h after CAS. Pre-procedure high DWI signal of the plaque was associated with an increased incidence of post-procedure microembolizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Recanalization of Thromboangiitis Obliterans (Buerger’s Disease) in Twenty-Eight Consecutive Patients and Combined Antegrade–Retrograde Intervention in Eight Patients

Purpose: The aim of the study was to evaluate the technical success of the procedure and the clinical efficacy of treatment in patients with thromboangiitis obliterans (TAO) (Buerger’s disease) based on a change in the Rutherford classification. Materials and Methods: A total of 28 consecutive patients (26 males, 2 females, mean age 43.3 ± 5.32 years) underwent endovascular recanalization with a diagnosis of TAO, between April 2015 and July 2018. After unsuccessful attempts using the antegrade approach, retrograde approaches were used in 8 patients under ultrasound guidance. Clinical follow-up was routinely performed at 1-month, 3-month, 6-month, and 1-year intervals. Results: A total of 28 TAO patients underwent 40 procedures in 32 limbs. Technical success was achieved in 28 of the 32 limbs (87.5%). In total, 45 of 59 (76.2%) below the knee arteries were treated successfully. One major amputation was performed, providing a 96.8% rate for limb salvage both at 12 and 24 months. Amputation-free survival estimated by Kaplan–Meier analysis was 84% at 12 and 24 months. Primary patency rates at 12, 24, and 36 months were 84%, 78%, and 75%, respectively. Secondary patency rates were 87.5% both at 12 and 24 months. Conclusion: Endovascular treatment is a technically feasible and potentially effective treatment modality for Buerger’s disease. Combined antegrade and retrograde interventions in TAO patients may improve technical success and clinical recovery, especially in cases where the antegrade approach has failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cryoablation of Stage T1b Renal Cell Carcinoma: Safety, Technical Results, and Clinical Outcomes

Purpose: The use of percutaneous cryoablation for T1b (4.1–7.0 cm) renal cell carcinoma, has not yet been widely adopted. The purpose of this study was to describe our experience in the cryoablation of stage T1b tumors with an emphasis on safety, technical results, and clinical outcomes. Materials and Methods: A retrospective review of hospital records identified 37 patients who underwent cryoablation for T1b lesions from 2008 to 2018. Patient demographics, comorbidities, tumor characteristics, technical parameters, and outcomes were recorded and analyzed. Recurrence-free, overall, and cancer-specific survival rates were estimated using the Kaplan–Meier method. Results: Thirty-seven patients (22 males, 15 females; mean age 66.5 ± 11.3) with 37 T1b tumors (mean diameter 47.3 ± 6.3 mm) were included. A median of 3 probes were used (range: 1–7). Angio-embolization was used in 3/37 (8.1%) and 2/37 patients (5.4%) required hydrodissection. The mean number of total cryoablation procedures for each patient was 1.5 (median 1; range: 1–4). Technical success was achieved in 88.2% of patients. Recurrence-free survival was 96.5%, 86.1%, and 62.6% at 1, 2, and 3 years respectively. Cancer-specific survival was 100% at 1, 2, and 3 years respectively. Overall survival was 96.7%, 91.8%, and 77.6% at 1, 2, and 3 years respectively. Complications classified as CIRSE grade 2 or higher occurred in 6/37 (16.2%) patients. Conclusion: T1b cryoablation is associated with high rates of technical success, excellent cancer-specific survival, and an acceptable safety profile. Level of Evidence: Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging Reduces Radiation and Contrast Medium Exposure During Endovascular Revascularization of Iliac Steno-Occlusive Disease

Introduction: To evaluate feasibility, safety and efficacy of fusion imaging in order to guide endovascular revascularization of iliac steno-occlusive disease. Materials and Methods: Retrospectively, we identified twenty-six patients (20 male, mean age 63 ± 8y; Rutherford II-V) who underwent revascularization of a chronic total occlusion (n = 6; 23%) or severe stenosis (n = 20; 77%) of the common and/or external iliac artery. Median lesion length was 33 mm (IQR 20–60). In one group of patients (NEW; n = 11), fusion imaging with 2-D/3-D registration was used to guide revascularization. No baseline digital subtraction angiography (DSA) had been acquired in these patients. In another group of patients (OLD; n = 15), no fusion imaging had been utilized and at least one DSA run had been performed to guide the procedure. In both groups, final DSA of the treated lesions was performed. Number of DSA runs, radiation and contrast medium exposure, technical success (residual stenosis < 30%) and complications were analyzed. Results: Median DSA runs needed in OLD for guidance were n = 2 (IQR 2–3) and in NEW n = 0 (IQR 0–0; p = 0.001). Compared to OLD, median dose area product (DAP) was reduced by 17,118 mGy*cm{sup 2} (IQR 10,407–23,614; p = 0.016) if fusion imaging guidance had been used (NEW). Based on the median DAP of the final angiogram in NEW, median DAP reduction was 6007 mGy*cm{sup 2} (IQR 5012–16,105; p = 0.1). Median total contrast medium volume injected in NEW was 45 ml (IQR 30–90) and in OLD 120 ml (IQR 100–140; p = 0.001). Technical success was 100% for both groups. In 1/27 patients (3.7%) a minor complication (embolism) occurred. Conclusion: Fusion imaging proved to be feasible as well as safe and significantly reduces radiation and contrast medium exposure during endovascular revascularization of iliac steno-occlusive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Fully Covered Irradiation Stent Versus a Partially Covered Irradiation Stent for Unresectable Malignant Dysphagia: A Single-Center Experience

Purpose: To assess the efficacy and safety of a newly developed fully covered irradiation stent (FCIS) compared with a partially covered irradiation stent (PCIS) in patients with unresectable malignant dysphagia. Materials and Methods: Data of 195 patients [158 (81.0%) males, median age of 75 years (range 49–89 years)] who underwent FCIS or PCIS placement for unresectable malignant dysphagia from January 2012 to November 2017 were retrospectively analyzed. The median follow-up time was 181 days (range 4–547 days). Outcomes were measured in terms of recurrent dysphagia (primary), technical success, clinical success, overall survival, and adverse events. Recurrent dysphagia was analyzed by Fine–Gray regression model. Results: The technical success rate was 97.8% (87/89) in the FCIS group and 99.1% (105/106) in the PCIS group (P = 0.59). The clinical success rate was 100.0% in both groups. There was no statistically significant difference in the recurrent dysphagia rate between the FCIS and PCIS groups (21.8% vs. 28.6%; P = 0.12). Compared with PCISs, FCISs were associated with a decrease in tissue/tumor growth rate (11.5% vs. 21.9%; P = 0.01), while stent migration rates were statistically comparable (11.5% vs. 5.7%; P = 0.23). The median overall survivals were comparable between the FCIS and PCIS groups (164 days vs. 162 days; P = 0.70). A dysphagia score of 4 and metastasis were risk factors for survival. No significant differences were observed in the rates of adverse events, including chest pain, fistula formation, hemorrhage, and aspiration pneumonia (P > 0.05). Conclusion: For patients with unresectable malignant dysphagia, this newly developed FCIS can provide efficacy and safety comparable to those of a PCIS. Compared with PCIS, this FCIS is more successful in preventing tissue/tumor growth, with a comparable stent migration rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Safety of Continuing Therapeutic Anticoagulation During Inferior Vena Cava Filter Retrieval: A 6-Year Retrospective Review from a Tertiary Centre

Purpose: Assess the safety of inferior vena cava (IVC) filter retrieval in patients taking anticoagulation, compared to a non-anticoagulated cohort. Materials and Methods: Single-centre retrospective analysis of patients who underwent IVC filter retrieval between January 2012 and February 2018. Information about patient demographics, anticoagulation, tilt, major and minor complications was collected. Major complications were defined as: IVC injury from the filter retrieval, retained fragment of filter, filter fracture and filter embolisation. Minor complications were defined as: neck haematoma and puncture site infection. Results: Total of 357 patients (age 18–95, Male: 231) underwent IVC filter retrieval, comprising of Cook Celect Platinum, Cook Celect, and ALN-branded filters. Of these 182 patients were on anticoagulation and 175 patients were not on anticoagulation, based on the indication for the filter (thrombosis or prophylaxis) and at the discretion of the referring unit who were managing the anticoagulation. IVC filter retrieval was technically successful in 349 patients. Five major complications (1.4% of retrievals) were recorded and no minor complications (0% of retrievals). In the anticoagulation cohort, there were two major complications (1.1% of retrievals) both related to IVC injury. In the non-anticoagulated cohort, there were three major complications (1.7% of retrievals) relating to filter embolisation, IVC injury, and filter fracture. Conclusions: IVC filter retrieval is a safe procedure with a low complication rate. Being on anticoagulation does not increase the risk of a major complication or change the management of major complication compared with a non-anticoagulated cohort. IVC filter retrieval is safe to perform in patients currently taking prophylactic or therapeutic anticoagulation based on our cohort. Level of Evidence: Level 3, retrospective cohort study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries

Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present paper, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10 -9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Finally and overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

A bespoke health risk assessment methodology for the radiation protection of astronauts

An alternative approach that is particularly suitable for the radiation health risk assessment (HRA) of astronauts is presented. The quantity, Radiation Attributed Decrease of Survival (RADS), representing the cumulative decrease in the unknown survival curve at a certain attained age, due to the radiation exposure at an earlier age, forms the basis for this alternative approach. Results are provided for all solid cancer plus leukemia incidence RADS from estimated doses from theoretical radiation exposures accumulated during long-term missions to the Moon or Mars. For example, it is shown that a 1000-day Mars exploration mission with a hypothetical mission effective dose of 1.07 Sv at typical astronaut ages around 40 years old, will result in the probability of surviving free of all types of solid cancer and leukemia until retirement age (65 years) being reduced by 4.2% (95% CI 3.2; 5.3) for males and 5.8% (95% CI 4.8; 7.0) for females. RADS dose–responses are given, for the outcomes for incidence of all solid cancer, leukemia, lung and female breast cancer. Results showing how RADS varies with age at exposure, attained age and other factors are also presented. The advantages of this alternative approach, over currently applied methodologies for the long-term radiation protection of astronauts after mission exposures, are presented with example calculations applicable to European astronaut occupational HRA. Some tentative suggestions for new types of occupational risk limits for space missions are given while acknowledging that the setting of astronaut radiation-related risk limits will ultimately be decided by the Space Agencies. Suggestions are provided for further work which builds on and extends this new HRA approach, e.g., by eventually including non-cancer effects and detailed space dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison and multi-model inference of excess risks models for radiation-related solid cancer

In assessments of detrimental health risks from exposures to ionising radiation, many forms of risk to dose–response models are available in the literature. The usual practice is to base risk assessment on one specific model and ignore model uncertainty. The analysis illustrated here considers model uncertainty for the outcome all solid cancer incidence, when modelled as a function of colon organ dose, using the most recent publicly available data from the Life Span Study on atomic bomb survivors of Japan. Seven recent publications reporting all solid cancer risk models currently deemed plausible by the scientific community have been included in a model averaging procedure so that the main conclusions do not depend on just one type of model. The models have been estimated with different baselines and presented for males and females at various attained ages and ages at exposure, to obtain specially computed model-averaged Excess Relative Risks (ERR) and Excess Absolute Risks (EAR). Monte Carlo simulated estimation of uncertainty on excess risks was accounted for by applying realisations including correlations in the risk model parameters. Three models were found to weight the model-averaged risks most strongly depending on the baseline and information criteria used for the weighting. Fitting all excess risk models with the same baseline, one model dominates for both information criteria considered in this study. Based on the analysis presented here, it is generally recommended to take model uncertainty into account in future risk analyses.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Influence of neutron cross-section resonances on organ/tissue equivalent and effective dose coefficients for the ICRP voxel phantoms

The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. Here In this study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.

36 MATERIALS SCIENCE↗

Evidence of long-distance dispersal of a gray wolf from the Chernobyl Exclusion Zone

The Chernobyl Exclusion Zone (CEZ) is a ~ 4300 km 2 area in Belarus and Ukraine that remains heavily contaminated with radiation from the nuclear accident of 1986. Long standing controversy persists on the fate of wildlife within the CEZ following human abandonment of the area. Human residency remains extremely sparse, and the CEZ has become a refuge for some populations of wildlife, including gray wolves (Canis lupus). Here, using GPS telemetry, we documented the first long-distance movements of a young (1-2 years) male wolf from the CEZ into the surrounding landscape. The wolf travelled 369 km from its home range center over a 21-day period in February 2015. In the 95 days prior to dispersal, the wolf maintained a home range of ~ 28 km 2 , with daily displacements rarely exceeding 5 km. With the onset of dispersal, daily displacement increased to a mean of 16.8 km. The dispersal of a young wolf is an important observation because it suggests that the CEZ may serve as a source for some wildlife populations outside of the CEZ, and raises questions about the potential spread of radiation-induced genetic mutations to populations in uncontaminated areas.

59 BASIC BIOLOGICAL SCIENCES↗

Structural and Functional Analysis of the Spermatogenic Epithelium in Rats Exposed to Titanium Dioxide Nanoparticles

We studied immunohistochemical and morphometric characteristics of the spermatogenic epithelium in rats against the background of peroral administration of nanoparticles containing titanium dioxide. Substantial degenerative changes in the spermatogenic epithelium were revealed: thinning, disorganization of layers, and detachment of sperm cells from the basement membrane. Immunohistochemical analysis revealed reduced proliferative activity and differentiation potential of epithelial cells, which was confirmed by changes in the expression of Ki-67 and c-kit markers. Our data attest to unfavorable effects of titanium dioxide nanoparticles on the structural and functional characteristics of the reproductive system in male rats leading to spermatogenesis disturbances.

60 APPLIED LIFE SCIENCES↗