Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Radio emission signature of Saturn immersions in Jupiter's magnetic tail

During the interval from about May through August 1981, when Voyager 2 was inbound to Saturn, the Planetary Radio Astronomy instrument measured repeated, dramatic decreases in the intensity of the Saturn Kilometric Radiation (SKR). The emission dropouts averaged two orders of magnitude below mean energy levels and varied from about 1 to 10 Saturn rotations in duration. Comparison with pre-Saturn encounter Voyager 1 observations (June to November, 1980) shows that the SKR dropouts were unique to the Voyager 2 observing interval, consistent with the closer proximity of Saturn to Jupiter's distant magnetotail in 1981. Further, the dropouts occurred on the average at times when Voyager 2 is known to have been within or near Jupiter's magnetic tail.

Desch, M. D.↗

Rate capability and magnetic field tolerance measurements of fast timing microchannel plate photodetectors

Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. In this paper, we have tested the rate capability and magnetic field tolerance of 6 x 6 cm 2 microchannel plate photodetectors fabricated at Argonne National Laboratory. The microchannel plate photodetector is designed as a low-cost all-glass vacuum package with a chevron pair stack of next-generation microchannel plates functionalized by atomic layer deposition. The rate capability test was performed using Fermilab’s 120 GeV/c primary proton beam, and the magnetic field tolerance test was performed using a solenoid magnetic with tunable magnetic field strength up to 4 T. Finally, the measured gain of the microchannel plate photodetector is stable up to 75 kHz/cm 2 and varies depending on the applied magnetic field strength and the rotation angle relative to the magnetic field direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Impact of the BLAST Magnetic Field on the Cerenkov Detectors

We report a factor of two improvement to the efficiencies of a large array of diffusely reflective aerogel Cerenkov detectors which were operated near a high magnetic field. This was accomplished by designing additional magnetic shielding. The improvement was studied by observing the ADC spectrum of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

Study of the properties of thin Li films and their relationship with He plasmas using ion beam analysis in the DIONISOS experiment

Plasma facing component (PFC) conditioning dramatically affects plasma performance in magnetic confinement fusion experiments. Lithium (Li) has been used in several machines to condition PFC with subsequent improvements to plasma performance. Multiple studies have investigated the interactions of Li with deuterium (D) and oxygen (O) in order to ascertain the mechanisms behind the enhanced plasma performance. Ion Beam Analysis (IBA) is a useful tool to interrogate PFC surfaces as they interact with plasmas. Dynamics of ion implantation and sputtering of surfaces (DIONISOS) is a linear plasma device, capable of generating discharges with fluxes ~10 21 m -2 s -1 and Te ~6 eV, coupled to an ion accelerator. DIONISOS is capable of analyzing samples using Elastic Recoil Detection (ERD) and Rutherford Backscattering Spectroscopy (RBS) during plasma exposures. The facility has been equipped with a Li deposition system for evaporation of thin coatings on different substrates. The evaporator enables real time ERD and RBS measurements of deposition and erosion of Li coatings on different substrates and the interaction of the Li with the vacuum and plasma. Considerations for ERD, e.g., ion species, energy, and data acquisition frequency, are presented. Furthermore, this work is the basis for further investigation of He, H, and D retention in solid and liquid Li.

47 OTHER INSTRUMENTATION↗

SOLAR MAGNETIC TRACKING. IV. THE DEATH OF MAGNETIC FEATURES

The removal of magnetic flux from the quiet-Sun photosphere is important for maintaining the statistical steady state of the magnetic field there, for determining the magnetic flux budget of the Sun, and for estimating the rate of energy injected into the upper solar atmosphere. Magnetic feature death is a measurable proxy for the removal of detectable flux, either by cancellation (submerging or rising loops, or reconnection in the photosphere) or by dispersal of flux. We used the SWAMIS feature tracking code to understand how nearly 2 Multiplication-Sign 10{sup 4} magnetic features die in an hour-long sequence of Hinode/SOT/NFI magnetograms of a region of the quiet Sun. Of the feature deaths that remove visible magnetic flux from the photosphere, the vast majority do so by a process that merely disperses the previously detected flux so that it is too small and too weak to be detected, rather than completely eliminating it. The behavior of the ensemble average of these dispersals is not consistent with a model of simple planar diffusion, suggesting that the dispersal is constrained by the evolving photospheric velocity field. We introduce the concept of the partial lifetime of magnetic features, and show that the partial lifetime due to Cancellation of magnetic flux, 22 hr, is three times slower than previous measurements of the flux turnover time. This indicates that prior feature-based estimates of the flux replacement time may be too short, in contrast with the tendency for this quantity to decrease as resolution and instrumentation have improved. This suggests that dispersal of flux to smaller scales is more important for the replacement of magnetic fields in the quiet Sun than observed bipolar cancellation. We conclude that processes on spatial scales smaller than those visible to Hinode dominate the processes of flux emergence and cancellation, and therefore also the quantity of magnetic flux that threads the photosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

MGS MAG/ER Data Analysis Using a Time and Magnetic Field Dependent Electron Transport Model

The goal of that project was to examine certain details about the dayside electron environment at Mars as seen by the Mars Global Surveyor (MGS) magnetometer/electron reflectometer (MAG/ER) instrument. Specifically, we stated that we would use the Khazanov and Liemohn (K&L) kinetic electron transport model to analyze features in the observations. This code includes a non-uniform magnetic field and time-dependence in the result (different from most other models of this type). It was originally developed for electron motion along field lines in the Earth's magnetosphere (between conjugate ionospheres), and is thus quite appropriate for application to the Mars magnetic field scenario. Numerous code developments were implemented and the Mars version of the K&L model is fully operational. Initial results from this code have focused on the examination of MGS MAG/ER observations in the crustal field region when it is on the dayside. After several presentations at scientific meetings, this study culminated in a JGR publication last year.

Liemohn, Michael W.↗

Electron cyclotron beam measurement system in the Large Helical Device

In order to evaluate the electron cyclotron (EC) heating power inside the Large Helical Device vacuum vessel and to investigate the physics of the interaction between the EC beam and the plasma, a direct measurement system for the EC beam transmitted through the plasma column was developed. The system consists of an EC beam target plate, which is made of isotropic graphite and faces against the EC beam through the plasma, and an IR camera for measuring the target plate temperature increase by the transmitted EC beam. This system is applicable to the high magnetic field (up to 2.75 T) and plasma density (up to 0.8 × 10{sup 19} m{sup −3}). This system successfully evaluated the transmitted EC beam profile and the refraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Muon g-2 Experiment overview and status as of June 2016

The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will also extend the search for the electric dipole moment (EDM) of the muon by approximately two orders of magnitude, with a sensitivity down to 10 -21 e.cm. Both of these measurements are made by combining a precise measurement of the 1.45T storage ring magnetic field with an analysis of the modulation of the decay rate of higher-energy positrons (from anti-muons), recorded by 24 calorimeters and 3 straw tracking detectors. Furthermore, the recent progress in the alignment of the electrostatic quadrapole plates and the trolley rails inside the vacuum chambers, and in establishing the uniform storage ring magnetic field will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-Space Manipulations of Electron Beams for X-Ray Free-Electron Lasers and Inverse Compton Scattering Sources [Thesis]

This dissertation describes advanced techniques of phase space manipulations of the electron beam for improving performance and efficiency of high brightness X-ray light sources based on the free-electron Laser (FEL) and inverse-Compton scattering (ICS) processes. In particular, it first discusses a novel bunch-compression scheme based on a double transverseto-longitudinal phase-space exchanger – dubbed emittance exchanger (EEX) – separated by a demagnifying transverse-optics system. While the outline of the scheme is quite sophisticated, the basic physics behind it is quite straight-forward. The benefits and disadvantages of these scheme are compared to the conventional approach of compressing a bunch using a magnetic bunch-compression chicane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the effect of spherical aberrations on a solenoid scan

Solenoid scans are often used to determine the beam emittance of an intense relativistic electron beam (IREB). In a solenoid scan, the beam size is measured at a location downstream of the solenoid as a function of the strength of the solenoid magnetic field. The emittance is then inferred using a beam optics model of the transport of the beam through the solenoid magnet to the imaging location. This requires precise knowledge of the field strength and shape as a function of the current supplied to the solenoid. The beam optics model for an IREB needs to include an accurate model of the magnetic field. Unfortunately, most beam optics models do not include the effect of spherical aberrations which are inherent in a solenoid magnet. Spherical aberrations are manifested as an essentially quadratic increase in the solenoid magnetic field as a function of radius. One consequence of this is that the focal length will be dependent on the beam radius. This note examines the sensitivity of a typical solenoid scan performed on DARHT axis 2 to spherical aberrations. The sensitivity to spherical aberrations is examined as a function of the beam envelope size and the drift distance from the solenoid magnet to the imaging station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The next-generation magnetic recoil spectrometer (MRSnext) on OMEGA and NIF for diagnosing ion temperature, yield, areal density, and alpha heating

The next-generation magnetic recoil spectrometer (MRSnext) is being designed to replace the current MRS at the National Ignition Facility and OMEGA for measurements of the neutron spectrum from an inertial confinement fusion implosion. The MRSnext will provide a far-superior performance and faster data turnaround than the current MRS systems, i.e., a 2× and 6× improvement in energy resolution at the NIF and OMEGA, respectively, and 20× improvement in data turnaround time. The substantially improved performance of the MRSnext is enabled by using electromagnets that provide a short focal plane (12–16 cm) and unprecedented flexibility for a wide range of applications. In addition to being able to measure neutron yield, apparent ion temperature, areal density, and plasma-flow velocity over a wide range of yields, the NIF MRSnext will be able to directly, uniquely assess the alpha heating of the fuel ions through measurements of the alpha knock-on tail in the neutron spectrum. The goal is to implement a radiation-hard electronic detection system capable of providing rapid data acquisition and analysis. The development of the MRSnext will also set the foundation for the more advanced, time-resolving MRSt and serve as a testbed for its implementation on the NIF.

47 OTHER INSTRUMENTATION↗

MAGNETIC ENERGY SPECTRA IN SOLAR ACTIVE REGIONS

Line-of-sight magnetograms for 217 active regions (ARs) with different flare rates observed at the solar disk center from 1997 January until 2006 December are utilized to study the turbulence regime and its relationship to flare productivity. Data from the SOHO/MDI instrument recorded in the high-resolution mode and data from the BBSO magnetograph were used. The turbulence regime was probed via magnetic energy spectra and magnetic dissipation spectra. We found steeper energy spectra for ARs with higher flare productivity. We also report that both the power index, {alpha}, of the energy spectrum, E(k) {approx} k{sup -}{alpha}, and the total spectral energy, W = {integral}E(k)dk, are comparably correlated with the flare index, A, of an AR. The correlations are found to be stronger than those found between the flare index and the total unsigned flux. The flare index for an AR can be estimated based on measurements of {alpha} and W as A = 10{sup b}({alpha}W){sup c}, with b = -7.92 {+-} 0.58 and c = 1.85 {+-} 0.13. We found that the regime of the fully developed turbulence occurs in decaying ARs and in emerging ARs (at the very early stage of emergence). Well-developed ARs display underdeveloped turbulence with strong magnetic dissipation at all scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Microwave radiation power of relativistic electron beam with virtual cathode in the external magnetic field

The study of the output power of the electromagnetic radiation of the relativistic electron beam (REB) with virtual cathode in the presence of external magnetic field has been found out. The typical dependencies of the output microwave power of the vircator versus external magnetic field have been analyzed by means of 3D electromagnetic simulation. It has been shown that the power of vircator demonstrates several maxima with external magnetic field growth. The characteristic features of the power behavior are determined by the conditions of the virtual cathode formation in the presence of the external transversal magnetic field and the REB self-magnetic fields.

43 PARTICLE ACCELERATORS↗

Experimental investigation of a 1 kA/cm{sup 2} sheet beam plasma cathode electron gun

In this paper, a cold cathode based sheet-beam plasma cathode electron gun is reported with achieved sheet-beam current density ∼1 kA/cm{sup 2} from pseudospark based argon plasma for pulse length of ∼200 ns in a single shot experiment. For the qualitative assessment of the sheet-beam, an arrangement of three isolated metallic-sheets is proposed. The actual shape and size of the sheet-electron-beam are obtained through a non-conventional method by proposing a dielectric charging technique and scanning electron microscope based imaging. As distinct from the earlier developed sheet beam sources, the generated sheet-beam has been propagated more than 190 mm distance in a drift space region maintaining sheet structure without assistance of any external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of the Earth's magnetic field on large area photomultipliers

The influence of the Earth's magnetic field on large area photomultipliers proposed for a future deep sea neutrino telescope was studied under the EU-funded KM3NeT design study. The aims were to evaluate variations in PMT performance in the Earth's magnetic field and to decide whether the use of magnetic shielding is necessary. Measurements were performed on three Hamamatsu PMTs: two 8-inch R5912 types, one of these with super-bi-alkali photocathode, and a 10-inch R7081 type with a standard bi-alkali photocathode. The various characteristics of the PMTs were measured while varying the PMT orientations with respect to the Earth's magnetic field, both with and without a mu-metal cage as magnetic shield. In the 8-inch PMTs the impact of the magnetic field was found to be smaller than that on the 10-inch PMT. The increased quantum efficiency in the 8 super-bi-alkali PMT almost compensated its smaller detection surface compared to the 10' PMT. No significant effects were measured upon transit time and the fraction of spurious pulses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-amplitude auroral electric fields measured with DE 1

A large fraction of the available electric field data from the plasma wave instrument (PWI) on the Dynamics Explorer (DE) 1 satellite has recently been searched for events with large-amplitude electric fields. The magnitude and distribution of these peak events as functions of altitude have been determined. The largest amplitudes were found between 1.4 and 2.5 RE and the probability of finding large electric fields was greatest in the range of 1.5 to 1.7 RE. However, when the measured electric field values are 'mapped' to the Earth's surface in order to account for the geometry of the geomagnetic field lines, then the mapped values always increase with increasing altitude. This radial dependence is considered to be evidence for magnetic field-aligned electric fields. The largest electric field that was detected with the DE 1 instrument had a magnitude exceeding 840 mV/m and was found at 1.45 R(E). This field appears to be associated with a low-frequency wave. At subauroral latitudes the average mapped electric field is nearly constant with altitude, as it should be where there are no magnetic field-aligned potential drops. Within auroral latitudes the average value of the mapped electric field increases as altitude increases. The largest gradients are found between 1.3 and 2 R(E).

Weimer, D. R.↗

Solar Magnetism eXplorer (Solme X)

The magnetic field plays a pivotal role in many fields of Astrophysics. This is especially true for the physics of the solar atmosphere. Measuring the magnetic field in the upper solar atmosphere is crucial to understand the nature of the underlying physical processes that drive the violent dynamics of the solar corona-that can also affect life on Earth. SolmeX, a fully equipped solar space observatory for remote-sensing observations, will provide the first comprehensive measurements of the strength and direction of the magnetic field in the upper solar atmosphere. The mission consists of two spacecraft, one carrying the instruments, and another one in formation flight at a distance of about 200 m carrying the occulter to provide an artificial total solar eclipse. This will ensure high-quality coronagraphic observations above the solar limb. SolmeX integrates two spectro-polarimetric coronagraphs for off-limb observations, one in the EUV and one in the IR, and three instruments for observations on the disk. The latter comprises one imaging polarimeter in the EUV for coronal studies, a spectro-polarimeter in the EUV to investigate the low corona, and an imaging spectro-polarimeter in the UV for chromospheric studies. SOHO and other existing missions have investigated the emission of the upper atmosphere in detail (not considering polarization), and as this will be the case also for missions planned for the near future. Therefore it is timely that SolmeX provides the final piece of the observational quest by measuring the magnetic field in the upper atmosphere through polarimetric observations

Magnetic Fields↗