Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Leg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

A Shell/3D Modeling Technique for Delaminations in Composite Laminates

A shell/3D modeling technique was developed for which a local solid finite element model is used only in the immediate vicinity of the delamination front. The goal was to combine the accuracy of the full three-dimensional solution with the computational efficiency of a plate or shell finite element model. Multi-point constraints provide a kinematically compatible interface between the local 3D model and the global structural model which has been meshed with plate or shell finite elements. For simple double cantilever beam (DCB), end notched flexure (ENF), and single leg bending (SLB) specimens, mixed mode energy release rate distributions were computed across the width from nonlinear finite element analyses using the virtual crack closure technique. The analyses served to test the accuracy of the shell/3D technique for the pure mode I case (DCB), mode II case (ENF) and a mixed mode I/II case (SLB). Specimens with a unidirectional layup where the delamination is located between two 0 plies, as well as a multidirectional layup where the delamination is located between two non-zero degree plies, were simulated. For a local 3D model extending to a minimum of about three specimen thicknesses in front of and behind the delamination front, the results were in good agreement with mixed mode strain energy release rates obtained from computations where the entire specimen had been modeled with solid elements. For large built-up composite structures modeled with plate elements, the shell/3D modeling technique offers a great potential, since only a relatively small section in the vicinity of the delamination front needs to be modeled with solid elements.

Krueger, Ronald↗

Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

Evidence for altered alpha-adrenoreceptor responsiveness after a single bout of maximal exercise

We studied hemodynamic responses to alpha- and beta-receptor agonists in eight men to test the hypothesis that adrenoreceptor responsiveness is altered within 24 h of the performance of maximal exercise. Adrenoreceptor responsiveness was tested under two experimental conditions (with and without maximal exercise). Adrenoreceptor tests were performed 24 h after each subject performed graded upright cycle ergometry to volitional exhaustion. The 2 test days (experimental conditions) were separated by at least 1 wk, and the order of exercise and no-exercise conditions was counterbalanced. Steady-state graded infusions of phenylephrine (PE) and isoproterenol (Iso) were used to assess alpha- and beta-adrenoreceptor responsiveness, respectively. Slopes calculated from linear regressions between Iso and PE doses and changes in heart rate, blood pressure, and leg vascular resistance for each subject were used as an index of alpha- and beta-adrenoreceptor responsiveness. The slope of the relationship between heart rate and Iso with maximal exercise was 1773 +/- 164 beats x microm-1x kg-1x min-1 compared with 1987 +/- 142 beats x microg-1x kg-1x min-1 without exercise (P = 0.158), whereas the slopes of the relationship between vascular resistance to Iso were -438 +/- 123 peripheral resistance units (PRU) x microg-1x kg-1x min-1 with maximal exercise and -429 +/- 105 x microg-1x kg-1 x min-1 without exercise (P = 0.904). Maximal exercise was associated with greater (P < 0.05) vascular resistance (15.1 +/- 2.8 PRU x microg-1 kg-1x min-1) and mean arterial blood pressure (15.8 +/- 2.1 mmHg. microg-1x kg-1x min-1) responses to PE infusion compared with no exercise (9.0 +/- 2.0 PRU x microg-1 kg-1 x min-1 and 10.9 +/- 2.0 mmHg. microg-1x kg-1x min-1, respectively). These results provide evidence that a single bout of maximal exercise increases alpha1-adrenoreceptor responsiveness within 24 h without affecting beta-cardiac and vascular adrenoreceptor responses.

Non-NASA Center↗

New insights into differential baroreflex control of heart rate in humans

Recent data indicate that bilateral carotid sinus denervation in patients results in a chronic impairment in the rapid reflex control of blood pressure during orthostasis. These findings are inconsistent with previous human experimental investigations indicating a minimal role for the carotid baroreceptor-cardiac reflex in blood pressure control. Therefore, we reexamined arterial baroreflex [carotid (CBR) and aortic baroreflex (ABR)] control of heart rate (HR) using newly developed methodologies. In 10 healthy men, 27 +/- 1 yr old, an abrupt decrease in mean arterial pressure (MAP) was induced nonpharmacologically by releasing a unilateral arterial thigh cuff (300 Torr) after 9 min of resting leg ischemia under two conditions: 1) ABR and CBR deactivation (control) and 2) ABR deactivation. Under control conditions, cuff release decreased MAP by 13 +/- 1 mmHg, whereas HR increased 11 +/- 2 beats/min. During ABR deactivation, neck suction was gradually applied to maintain carotid sinus transmural pressure during the initial 20 s after cuff release (suction). This attenuated the increase in HR (6 +/- 1 beats/min) and caused a greater decrease in MAP (18 +/- 2 mmHg, P < 0.05). Furthermore, estimated cardiac baroreflex responsiveness (DeltaHR/DeltaMAP) was significantly reduced during suction compared with control conditions. These findings suggest that the carotid baroreceptors contribute more importantly to the reflex control of HR than previously reported in healthy individuals.

Non-NASA Center↗

Lower body negative pressure as a tool for research in aerospace physiology and military medicine

Lower body negative pressure (LBNP) has been extensively used for decades in aerospace physiological research as a tool to investigate cardiovascular mechanisms that are associated with or underlie performance in aerospace and military environments. In comparison with clinical stand and tilt tests, LBNP represents a relatively safe methodology for inducing highly reproducible hemodynamic responses during exposure to footward fluid shifts similar to those experienced under orthostatic challenge. By maintaining an orthostatic challenge in a supine posture, removal of leg support (muscle pump) and head motion (vestibular stimuli) during LBNP provides the capability to isolate cardiovascular mechanisms that regulate blood pressure. LBNP can be used for physiological measurements, clinical diagnoses and investigational research comparisons of subject populations and alterations in physiological status. The applications of LBNP to the study of blood pressure regulation in spaceflight, groundbased simulations of low gravity, and hemorrhage have provided unique insights and understanding for development of countermeasures based on physiological mechanisms underlying the operational problems.

Review↗

The effect of simulated weightlessness on hypobaric decompression sickness

BACKGROUND: A discrepancy exists between the incidence of ground-based decompression sickness (DCS) during simulated extravehicular activity (EVA) at hypobaric space suit pressure (20-40%) and crewmember reports during actual EVA (zero reports). This could be due to the effect of gravity during ground-based DCS studies. HYPOTHESIS: At EVA suit pressures of 29.6 kPa (4.3 psia), there is no difference in the incidence of hypobaric DCS between a control group and group exposed to simulated weightlessness (supine body position). METHODS: Male subjects were exposed to a hypobaric pressure of 29.6 kPa (4.3 psi) for up to 4 h. The control group (n = 26) pre-oxygenated for 60 min (first 10 min exercising) before hypobaric exposure and walking around in the altitude chamber. The test group (n = 39) remained supine for a 3 h prior to and during the 60-min pre-oxygenation (also including exercise) and at hypobaric pressure. DCS symptoms and venous gas emboli (VGE) at hypobaric pressure were registered. RESULTS: DCS occurred in 42% in the control and in 44% in simulated weightlessness group (n.s.). The mean time for DCS to develop was 112 min (SD +/- 61) and 123 min (+/- 67), respectively. VGE occurred in 81% of the control group subjects and in 51% of the simulated weightlessness subjects (p = 0.02), while severe VGE occurred in 58% and 33%, respectively (p = 0.08). VGE started after 113 min (+/- 43) in the control and after 76 min (+/- 64) in the simulated weightlessness group. CONCLUSIONS: No difference in incidence of DCS was shown between control and simulated weightlessness conditions. VGE occurred more frequently during the control condition with bubble-releasing arm and leg movements.

NASA Discipline Environmental Health↗

Unilateral lower limb suspension does not mimic bed rest or spaceflight effects on human muscle fiber function

We used Ca2+-activated skinned muscle fibers to test the hypothesis that unilateral lower leg suspension (ULLS) alters cross-bridge mechanisms of muscle contraction. Soleus and gastrocnemius biopsies were obtained from eight subjects before ULLS, immediately after 12 days of ULLS (post-0 h), and after 6 h of reambulation (post-6 h). Post-0 h soleus fibers expressing type I myosin heavy chain (MHC) showed significant reductions in diameter, absolute and specific peak Ca2+-activated force, unloaded shortening velocity, and absolute and normalized peak power. Fibers obtained from the gastrocnemius were less affected by ULLS, particularly fibers expressing fast MHC isoforms. Post-6 h soleus fibers produced less absolute and specific peak force than did post-0 h fibers, suggesting that reambulation after ULLS induced cell damage. Like bed rest and spaceflight, ULLS primarily affects soleus over gastrocnemius fibers. However, in contrast to these other models, slow soleus fibers obtained after ULLS showed a decrease in unloaded shortening velocity and a greater reduction in specific force.

NASA Discipline Musculoskeletal↗

Fiber size, type, and myosin heavy chain content in rhesus hindlimb muscles after 2 weeks at 2 G

BACKGROUND: Fiber atrophy and an increase in the percentage of fast fibers have been observed in Rhesus leg muscles after spaceflight. Hypothesis: Hypergravity will result in muscle fiber hypertrophy and an increase in the percentage of slow fibers. METHODS: Open muscle biopsies were obtained from Rhesus soleus, medial gastrocnemius (MG), and tibialis anterior (TA) muscles before and after 14 d of centrifugation (2 G) and in time-matched controls. Cage activity levels were measured by telemetry. RESULTS: Based on monoclonal antibody binding for myosin heavy chains (MHC), the fastest region of soleus contained a higher proportion of type I+II (27 vs. 13%) and had a tendency for a lower proportion of type I (38 vs. 61%, p = 0.10) fibers after than before centrifugation. There was a higher proportion of type I+II fibers in post- vs. pre-2 G (10 vs. 0.6%) MG biopsies. Fiber type distribution and MHC composition were unaffected in the TA. Overall, mean fiber sizes were unaffected by centrifugation. Average cage activity levels were 36% lower during than before 2 G. CONCLUSIONS: Our hypothesis was rejected. The changes in the proportion of fibers expressing type I MHC are the reverse of that expected with chronic loading of extensors and, paradoxically, are similar to changes observed with chronic unloading, such as occurs during spaceflight, in this primate model. The data are consistent with the observed decrease in total daily activity levels.

Non-NASA Center↗

The developmental segregation of posterior crista and saccular vestibular fibers in mice: a carbocyanine tracer study using confocal microscopy

The developmental segregation of gravistatic input mediated by saccular fibers and of angular acceleration input mediated by posterior crista (PC) fibers was analyzed for the first time in a developing mammal using carbocyanine dye tracing in fixed tissue. The data reveal a more extensive projection of either endorgan in 7-day-old mice (P7) than has previously been reported in adult mammals. While we confirm and extend many previous findings, we also describe a novel segregation of saccular and posterior crista fibers in the anterior half of the medial vestibular nucleus (Mv) not reported before. Our developmental analysis shows a progressive segregation of posterior crista and saccular fibers to their respective discrete projection areas between embryonic day 15 (E15) and birth (P0). Retention of overlap in young adult animals appears to reflect the early embryonic overlap found in most areas. The vestibular projection does not show a topological projection as has been described in many other sensory systems. We propose that the unique projection features of the vestibular endorgans may relate to the transformation of vestibular signals into a motor output in the three neuron reflex arc of the VOR, of which the primary vestibular projection constitutes the first leg.

NASA Discipline Developmental Biology↗

Depression, mood state, and back pain during microgravity simulated by bed rest

OBJECTIVE: The objective of this study was to develop a ground-based model for spinal adaptation to microgravity and to study the effects of spinal adaptation on depression, mood state, and pain intensity. METHODS: We investigated back pain, mood state, and depression in six subjects, all of whom were exposed to microgravity, simulated by two forms of bed rest, for 3 days. One form consisted of bed rest with 6 degrees of head-down tilt and balanced traction, and the other consisted of horizontal bed rest. Subjects had a 2-week period of recovery between the studies. The effects of bed rest on pain intensity in the lower back, depression, and mood state were investigated. RESULTS: Subjects experienced significantly more intense lower back pain, lower hemisphere abdominal pain, headache, and leg pain during head-down tilt bed rest. They had higher scores on the Beck Depression Inventory (ie, were more depressed) and significantly lower scores on the activity scale of the Bond-Lader questionnaire. CONCLUSIONS: Bed rest with 6 degrees of head-down tilt may be a better experimental model than horizontal bed rest for inducing the pain and psychosomatic reactions experienced in microgravity. Head-down tilt with balanced traction may be a useful method to induce low back pain, mood changes, and altered self-rated activity level in bed rest studies.

NASA Discipline Musculoskeletal↗

Project Galileo: completing Europa, preparing for Io

Galileo has completed the Europa leg of the Galileo Europa Mission, and is now pumping down the apojove in each succeeding orbit in preparation for the Io phase. Including three encounters earlier in the primary mission, the total of ten close passes by Europa have provided a wealth of interesting and provocative information about this intriguing body. The results presented include new and exciting information about Europa's interactions with Jupiter's magnetosphere, its interior structure, and its tantalizing surface features, which strongly hint at a watery subsurface layer. Additional data concerning Callisto, and its own outlook for a subsurface ocean are also presented. In addition the engineering aspects of operating the spacecraft during the past year are explored, as well as a brief examination of what will be the challenges to prepare for the Io encounters. The steadily increasing radiation dosage that the spacecraft is experiencing is well beyond the original design parameters, and is contributing to a number of spacecraft problems and concerns. The ability of the flight team to analyze and solve these problems, even at the reduced staffing levels of an extended mission, is a testament to their tenacity and loyalty to the mission. The engineering data being generated by these continuing radiation-induced anomalies will prove invaluable to designers of future spacecraft to Jupiter and its satellites. The lessons learned during this arduous process are presented. c 2000 International Astronautical Federation. Published by Elsevier Science Ltd. All rights reserved.

long duration↗

Spacelab Life Sciences flight experiments: an integrated approach to the study of cardiovascular deconditioning and orthostatic hypotension

The microgravity environment of spaceflight produces rapid cardiovascular changes which are adaptive and appropriate in that setting, but are associated with significant deconditioning and orthostatic hypotension on return to Earth's gravity. The rapidity with which these space flight induced changes appear and disappear provides an ideal model for studying the underlying pathophysiological mechanisms of deconditioning and orthostatic hypotension, regardless of etiology. Since significant deconditioning is seen after flights of very short duration, muscle atrophy due to inactivity plays, at most, a small role. These changes in circulatory control associated with cephalad fluid shifts, rather than inactivity per se, are probably more important factors. In order to test this hypothesis in a systematic way, a multidisciplinary approach which defines and integrates inputs and responses from a wide variety of circulatory sub-systems is required. The cardiovascular experiments selected for Spacelab Life Sciences flights 1 and 2 provide such an approach. Both human and animal models will be utilized. Pre- and post-flight characterization of the payload crew includes determination of maximal exercise capacity (bicycle ergometry), orthostatic tolerance (lower body negative pressure), alpha and beta adrenergic sensitivity (isoproterenol and phenylephrine infusions), baroreflex sensitivity (ECG-gated, stepwise changes in carotid artery transmural pressure with a pneumatic neck collar), and responses to a 24 h period of 5 deg head-down tilt. Measurements of cardiac output (CO2 and C2H2 rebreathing), cardiac chamber dimensions (phased-array 2-dimensional echocardiography), direct central venous pressure, leg volume (Thornton sock), limb blood flow and venous compliance (occlusion plethysmography), blood and plasma volumes, renal plasma flow and glomerular filtration rates, and various hormonal levels including catecholamines and atrial natriuretic factor will also be obtained. The central venous catheter will be inserted immediately pre-launch and monitored with heart rate and blood pressure in-flight until cardiac output, respiratory gas exchange and quantitative 2D echocardiography measurements can be performed. In-flight hemodynamic measurements will be repeated at rest and during submaximal exercise daily and also during maximal exercise midway through the flight to document the timecourse and extent of cardiovascular changes in the payload crew. Parallel studies are planned for the animals. In addition to measurements of right atrial and aortic pressures and cardiac output, a dorsal micro-circulatory chamber will allow determinations of changes in capillary and venular architecture and function in six of the rats. The techniques and findings from many of the SLS-1 and 2 supporting studies have already yielded significant information about circulatory regulation in patients with both hypo- and hypertension. The flight experiments themselves will provide new data to test the validity of both animal and human models currently used for simulating the fluid shifts of a micro-gravity environment. The development of effective countermeasures, not only for short and long duration space travellers, but also for Earth-bound medical patients can then be physiologically based on experimental data rather than anecdote.

Non-NASA Center↗

Quantitative determination of the mineral distribution in different collagen zones of calcifying tendon using high voltage electron microscopic tomography

High voltage electron microscopic tomography was used to make the first quantitative determination of the distribution of mineral between different regions of collagen fibrils undergoing early calcification in normal leg tendons of the domestic turkey, Meleagris gallopavo. The tomographic 3-D reconstruction was computed from a tilt series of 61 different views spanning an angular range of +/- 60 degrees in 2 degrees intervals. Successive applications of an interactive computer operation were used to mask the collagen banding pattern of either hole or overlap zones into separate versions of the reconstruction. In such 3-D volumes, regions specified by the mask retained their original image density while the remaining volume was set to background levels. This approach was also applied to the mineral crystals present in the same volumes to yield versions of the 3-D reconstructions that were masked for both the crystal mass and the respective collagen zones. Density profiles from these volumes contained a distinct peak corresponding only to the crystal mass. A comparison of the integrated density of this peak from each profile established that 64% of the crystals observed were located in the collagen hole zones and 36% were found in the overlap zones. If no changes in crystal stability occur once crystals are formed, this result suggests the possibilities that nucleation of mineral is preferentially and initially associated with the hole zones, nucleation occurs more frequently in the hole zones, the rate of crystal growth is more rapid in the hole zones, or a combination of these alternatives. All lead to the conclusion that the overall accumulation of mineral mass is predominant in the collagen hole zones compared to overlap zones during early collagen fibril calcification.

NASA Program Space Biology↗

Effects of exercise pressor reflex activation on carotid baroreflex function during exercise in humans

1. This investigation was designed to determine the contribution of the exercise pressor reflex to the resetting of the carotid baroreflex during exercise. 2. Ten subjects performed 3.5 min of static one-legged exercise (20 % maximal voluntary contraction) and 7 min dynamic cycling (20 % maximal oxygen uptake) under two conditions: control (no intervention) and with the application of medical anti-shock (MAS) trousers inflated to 100 mmHg (to activate the exercise pressor reflex). Carotid baroreflex function was determined at rest and during exercise using a rapid neck pressure/neck suction technique. 3. During exercise, the application of MAS trousers (MAS condition) increased mean arterial pressure (MAP), plasma noradrenaline concentration (dynamic exercise only) and perceived exertion (dynamic exercise only) when compared to control (P < 0.05). No effect of the MAS condition was evident at rest. The MAS condition had no effect on heart rate (HR), plasma lactate and adrenaline concentrations or oxygen uptake at rest and during exercise. The carotid baroreflex stimulus-response curve was reset upward on the response arm and rightward to a higher operating pressure by control exercise without alterations in gain. Activation of the exercise pressor reflex by MAS trousers further reset carotid baroreflex control of MAP, as indicated by the upward and rightward relocation of the curve. However, carotid baroreflex control of HR was only shifted rightward to higher operating pressures by MAS trousers. The sensitivity of the carotid baroreflex was unaltered by exercise pressor reflex activation. 4. These findings suggest that during dynamic and static exercise the exercise pressor reflex is capable of actively resetting carotid baroreflex control of mean arterial pressure; however, it would appear only to modulate carotid baroreflex control of heart rate.

Non-NASA Center↗

Effects of spaceflight on human calf hemodynamics

Chronic microgravity may modify adaptations of the leg circulation to gravitational pressures. We measured resting calf compliance and blood flow with venous occlusion plethysmography, and arterial blood pressure with sphygmomanometry, in seven subjects before, during, and after spaceflight. Calf vascular resistance equaled mean arterial pressure divided by calf flow. Compliance equaled the slope of the calf volume change and venous occlusion pressure relationship for thigh cuff pressures of 20, 40, 60, and 80 mmHg held for 1, 2, 3, and 4 min, respectively, with 1-min breaks between occlusions. Calf blood flow decreased 41% in microgravity (to 1.15 +/- 0.16 ml x 100 ml(-1) x min(-1)) relative to 1-G supine conditions (1.94 +/- 0.19 ml x 100 ml(-1) x min(-1), P = 0.01), and arterial pressure tended to increase (P = 0.05), such that calf vascular resistance doubled in microgravity (preflight: 43 +/- 4 units; in-flight: 83 +/- 13 units; P < 0.001) yet returned to preflight levels after flight. Calf compliance remained unchanged in microgravity but tended to increase during the first week postflight (P > 0.2). Calf vasoconstriction in microgravity qualitatively agrees with the "upright set-point" hypothesis: the circulation seeks conditions approximating upright posture on Earth. No calf hemodynamic result exhibited obvious mechanistic implications for postflight orthostatic intolerance.

NASA Experiment Number 178294 2/2↗

Orthostatic stress is necessary to maintain the dynamic range of cardiovascular control in space

In the upright position, gravity fills the low-pressure systems of human circulation with blood and interstitial fluid in the sections below the diaphragm. Without gravity one pressure component in the vessels disappears and the relationship between hydrostatic pressure and oncotic pressure, which regulates fluid passage across the capillary endothelium in the terminal vascular bed, shifts constantly. The visible consequences of this are a puffy face and "bird" legs. The plasma volume shrinks in space and the range of cardiovascular control is reduced. When they stand up for the first time after landing, 30-50% of astronauts suffer from orthostatic intolerance. It remains unclear whether microgravity impairs cardiovascular reflexes, or whether it is the altered volume status that causes the cardiovascular instability following space flight. Lower body negative pressure was used in several space missions to stimulate the cardiovascular reflexes before, during and after a space flight. The results show that cardiovascular reflexes are maintained in microgravity. However, the astronauts' volume status changed in space, towards a volume-retracted state, as measurements of fluid-regulating hormones have shown. It can be hypothesized that the control of circulation and body fluid homeostasis in humans is adapted to their upright posture in the Earth's gravitational field. Autonomic control regulates fluid distribution to maintain the blood pressure in that posture, which most of us have to cope with for two-thirds of the day. A determined amount of interstitial volume is necessary to maintain the dynamic range of cardiovascular control in the upright posture; otherwise orthostatic intolerance may occur more often.

manned↗

Muscle pain perception and sympathetic nerve activity to exercise during opioid modulation

The purpose of this experiment was to examine the effects of the endogenous opioid system on forearm muscle pain and muscle sympathetic nerve activity (MSNA) during dynamic fatiguing exercise. Twelve college-age men (24 +/- 4 yr) performed graded (1-min stages; 30 contractions/min) handgrip to fatigue 1 h after the ingestion of either 60 mg codeine, 50 mg naltrexone, or placebo. Pain (0-10 scale) and exertion (0-10 and 6-20 scales) intensities were measured during the last 15 s of each minute of exercise and every 15 s during recovery. MSNA was measured continuously from the peroneal nerve in the left leg. Pain threshold occurred earlier [1.8 +/- 1, 2. 2 +/- 1, 2.2 +/- 1 J: codeine, naltrexone, and placebo, respectively] and was associated with a lower rating of perceived exertion (RPE) (2.7 +/- 2, 3.6 +/- 2, 3.8 +/- 2: codeine, naltrexone, and placebo, respectively) in the codeine condition compared with either the naltrexone or placebo conditions. There were no main effects (i.e., drugs) or interaction (i.e., drugs x time) for either forearm muscle pain or RPE during exercise [pain: F (2, 22) = 0.69, P = 0.51]. There was no effect of drug on MSNA, heart rate, or blood pressure during baseline, exercise, or recovery. Peak exercise MSNA responses were 21 +/- 1, 21 +/- 2.0, and 21 +/- 2.0 bursts/30 s for codeine, naltrexone, and placebo conditions, respectively. Peak mean arterial pressure responses were 135 +/- 4, 131 +/- 3, and 132 +/- 4 mmHg for codeine, naltrexone, and placebo conditions, respectively. It is concluded that neither 60 mg codeine nor 50 mg naltrexone has an effect on forearm muscle pain, exertion, or MSNA during high- intensity handgrip to fatigue.

Clinical Trial↗

Artificial gravity as a countermeasure in long-duration space flight

Long-duration exposure to weightlessness results in bone demineralization, muscle atrophy, cardiovascular deconditioning, altered sensory-motor control, and central nervous system reorganizations. Exercise countermeasures and body loading methods so far employed have failed to prevent these changes. A human mission to Mars might last 2 or 3 years and without effective countermeasures could result in dangerous levels of bone and muscle loss. Artificial gravity generated by rotation of an entire space vehicle or of an inner chamber could be used to prevent structural changes. Some of the physical characteristics of rotating environments are outlined along with their implications for human performance. Artificial gravity is the centripetal force generated in a rotating vehicle and is proportional to the product of the square of angular velocity and the radius of rotation. Thus, for a particular g-level, there is a tradeoff between velocity of rotation and radius. Increased radius is vastly more expensive to achieve than velocity, so it is important to know the highest rotation rates to which humans can adapt. Early studies suggested that 3 rpm might be the upper limit because movement control and orientation were disrupted at higher velocities and motion sickness and chronic fatigue were persistent problems. Recent studies, however, are showing that, if the terminal velocity is achieved over a series of gradual steps and many body movements are made at each dwell velocity, then full adaptation of head, arm, and leg movements is possible. Rotation rates as high as 7.5-10 rpm are likely feasible. An important feature of the new studies is that they provide compelling evidence that equilibrium point theories of movement control are inadequate. The central principles of equilibrium point theories lead to the equifinality prediction, which is violated by movements made in rotating reference frames. Copyright 2000 Wiley-Liss, Inc.

Review Literature↗