Lightning summary report through 1971

An updated summary is presented of the lightning activity recorded at the John F. Kennedy Space Center and the Cape Kennedy Air Force Station. Data was compiled during the periods 1903 through 1924, 1957 through 1962, and 1964 through 1971.

Source record↗

Currents in Florida lightning return strokes.

The transmission line return stroke model is used to derive individual current versus time wave forms from measured electric fields. A total of 98 strokes in 21 flashes at distances less than or equal to 10 km and 63 strokes in 18 flashes at distances between 10 and 32 km are analyzed for current wave shape and magnitude. For the closer strokes, return stroke velocity is also determined from the electric field wave forms. Eighteen detailed current and field wave forms and a statistical distribution of peak currents are presented. Return stroke channel currents are found to exhibit a sharp initial peak which currents measured in tall structures at the base of the lightning channel apparently do not exhibit. A complete discussion of errors is given.

Uman, M. A.↗

Electric radiation fields of lightning return strokes in three isolated Florida thunderstorms

Peak value and risetime distributions for the electric radiation fields produced by lightning strokes to ground in three isolated Florida thunderstorms are presented. The storm at 195 km produced about 1000 return strokes having an average peak radiation field (normalized to 100 km) of about 5.5 V/m, the storm at 110 km produced about 700 strokes having 2.0 V/m, and the storm within 10 km produced about 100 strokes having 15.0 V/m. For each storm the average peak radiation field for first strokes was only slightly greater than the average peak field for subsequent strokes. For the sample of three storms the average peak radiation field in a given storm was proportional to the number of subsequent strokes per flash in that storm. The field risetimes for the two distant storms have statistical properties which are essentially identical to those reported for distant storms in Pennsylvania, whereas the close Florida storm exhibited significantly faster risetimes.

Lin, Y. T.↗

Correlated electric and magnetic fields from lightning return strokes

The first broad band (1 kHz to 5 mHz) correlated measurements of electric and magnetic fields from close lightning return strokes are presented. Sample wave forms are shown for the distance range 2-200 km. The transmission line return stroke model is used to find a typical current wave shape and return stroke velocity from the experimental data, and theoretical curves are given of electric and magnetic field as a function of time for 1, 5, 10, and 100 km by using this typical current and velocity.

Uman, M. A.↗

Radiation field wave forms produced by lightning stepped leaders

Broadband electric field data are presented which show stepped leader wave forms preceding records of distant lightning return strokes. The majority of leader pulses are characterized by a large initial peak with a small and slow opposite overshoot. Total pulse durations range from 15-40 microsec several milliseconds before the return stroke to 2-10 microsec immediately preceding the return stroke. Close to the ground the stepped leader pulses occur at regular 10- to 20-microsec intervals and are almost unipolar with rise times of about 1 microsec and full widths at half maximum in the range from 1 to 3 microsec. The ratio of the peak of the last leader pulse to the subsequent return stroke peak is typically 0.1, which suggests a peak step current near the ground of about 10% of the return stroke peak current.

Krider, E. P.↗

Electrostatic field changes and recovery curves produced by Florida lightning

Preliminary data on electric field changes produced by cloud-to-ground lightning and the subsequent field recoveries are presented. Both single-station and multiple-station observations were made. There is large variation in the data: total charge transfers range from 10 to 30 C and beyond, electric-field recovery times vary by a factor of 2 or more, and initial charge heights occur over a large interval. Only distance and angle dependencies are somewhat predictable, and then only in a few cases. Thus the field recovery mechanism is not a simple one.

Jacobson, E. A.↗

Regular radiation field pulses produced by intracloud lightning discharges

Sequences or bursts of uniform pulses have been recorded during a large fraction of intracloud lightning discharges in Florida and Arizona. The wave form of a typical pulse begins with a fast large-amplitude portion followed by a small and slowly varying overshoot. The full width and half maximum of the large amplitude peak is typically 0.75 microsec, and the time intervals between pulses are typically 5 microsec in both maritime and continental storms. The pulse shapes and interval times suggest that the source of these pulses in an intracloud dart-stepped leader process similar to that which has been photographed in discharges to ground.

Krider, E. P.↗

The structure of lightning flashes HF-UHF: 12 September 1975, Atlanta, Georgia

Simultaneous measurement of sferics at 3, 30, 139, and 295 MHz were made during thunderstorms. Wideband electronics and an analogue tape recorder continuously recorded the radiation from lightning with about 300 kHz of bandwidth. The data were obtained during the passage of a cold front. Flashing rate, burst rate and the structure of individual flashes were recorded. The record of a typical flash begins with a sudden burst of closely spaced pulses whose temporal structure is typical of the stepped leader, and ends in a large pulse suggestive of a first return stroke. The remainder of the flash consists of a sequence of pulses of varying amplitude separated by quiet periods of the order of milliseconds. The shape of these pulses and the temporal structure suggest that the first few large pulses are return strokes. Other discharges begin with widely spaced discrete pulses and resemble the preceding discharge less the leader and return stroke phase. The radiation exhibits a similar structure, at each of the frequencies monitored.

Levine, D. M.↗

Electrostatic field changes produced by Florida lightning

The electrical behavior of thunderstorms triggered by local heating and sea-breeze convergence, a low pressure disturbance, and a weak frontal passage has been studied at the NASA Kennedy Space Center, Florida. A nonlinear least-squares minimization procedure has been developed to describe changes in the total electrostatic field produced by lightning in terms of point charge models for the cloud charge distributions. The results indicate that discharges to ground usually neutralize cloud charges in the range from -10 to -40 C. The computed charge altitudes for Florida are somewhat higher than for other geographical locations, 6 to 9.5 km, but the corresponding ambient air temperatures, -10 to -34 C, are similar. A large fraction of the discharges to ground show total field changes which are small or even reversed in polarity within 3 km of the discharges. It is suggested that ground discharges often neutralize a small positive charge, 0.5 to 4 C at altitudes of 1 to 3 km, in addition to the larger negative charge higher in the cloud.

Jacobson, E. A.↗

Electric field statistics for close lightning return strokes near Gainesville, Florida

The salient properties of the electric field intensity from first and subsequent lightning return strokes in the 0-25 km distance range near Gainesville, Fla., are presented, including electric field wave shape versus distance, initial peak rise time versus distance, rise time histograms, initial peak magnitude versus distance, normalized (to 100 km) initial peak magnitude histograms, normalized initial peak magnitude versus rise time, ramp starting time versus distance, and field at 170 microsec versus distance. The mean normalized initial peak field for first return strokes was 9.9 V/m and for subsequent strokes, 5.7 V/m. The maximum measured values of normalized initial peak field were about 30 V/m. The largest field recorded at 170 microsec was about 25 kV/m generated by a first stroke within 0.5 km. Return strokes were found to lower a typical charge of the order of 1 C in 170 microsec.

Tiller, J. A.↗

Recording-tape lightning detector

Prerecorded magnetic tape monitors lightning strikes and records their peak current. It requires no external equipment, power, or human operator attention.

Livermore, S.↗

Simulation of radiation from lightning return strokes: The effects of tortuosity

A Monte Carlo simulation has been developed for the electromagnetic fields radiated from a tortuous lightning channel. This was done using a piecewise linear model for the channel and employing for each element the field radiated by a traveling wave on an arbitrarily oriented filament over a conducting plane. The simulation reproduces experimental data reasonably well and had been used to study the effects of tortuousity on the fields radiated by return strokes. Tortuosity can significantly modify the radiated waveform, tending to render it less representative of the current pulse and more nearly unipolar than one would expect based on the theory for a long straight channel. In the frequency domain the effect of tortuosity is an increase in high frequency energy as compared with an equivalent straight channel. The extent of this increase depends on the mean length of the elements comprising the channel and can be significant.

Levine, D. M.↗

Effects of 200 km propagation on Florida lightning return stroke electric fields

The electric fields produced by lightning return strokes near Kennedy Space Center, Florida, have been measured simultaneously at distances of about 5 to 25 km and about 200 km. Detailed records of the first 12 microsec of waveforms from four strokes are presented, as well as data on the initial field risetimes for 58 first and 92 subsequent strokes. The mean field risetime measured between the 10 to 90% points was about 1 microsec at the close station and about 2 microsec at the distant one.

Uman, M. A.↗

NOx production in lightning

The rate of odd nitrogen (NOx) production by electrical discharge through air was theoretically and experimentally estimated to be about 60,000 trillion NOx molecules per joule. The theoretical treatment employed a cylindrical shock-wave solution to calculate the rate of NOx production in high temperature reactions. The limits obtained were experimentally verified by subjecting a regulated air flow to electrical discharges followed by a measurement of NOx production using chemiluminescence. These measurements also indicated that water vapor content has no detectable effect on the NOx production rate. The results imply that lightning is a significant source of NOx, producing about 30-40 megatons NOx-N per year and possibly accounting for as much as 50% of the total atmospheric NOx source.

Chameides, W. L.↗

The temporal structure of HF and VHF radiations during Florida lightning return strokes

Measurements have been made of the HF and VHF radiation at 3, 30, 139, and 295 MHz produced during lightning return strokes, in correlation with wideband electric field measurements covering from about 300 Hz to 2 MHz. Intense pulses of RF are observed during the first return stroke in a discharge to ground, but with a 10-30 µsec time delay between the beginning of the stroke and the occurrence of significant RF radiation. The delay occurs at all frequencies and is short enough to suggest that the main channel and/or branches are the main initial sources of RF during the first stroke. During a subsequent return stroke, the RF starts an average of 265 µsec prior to the onset of the stroke. At 139 and 295 MHz, the subsequent stroke RF lasts only about 115 µsec; however, at 3 MHz, the radiation frequently persists up to and during the stroke.

David M Le Vine↗

The electric fields produced by lightning stepped leaders

The electric fields produced by stepped and dart-stepped leaders which immediately precede return strokes in lightning discharges to the ground have been recorded in Florida and Arizona. The mean interval time between normal steps is about 16 microsec, and the mean interval between dart steps is 6-8 microsec. The amplitudes of leader pulses in Florida increase just prior to the return stroke, the largest usually being about 10% of the return-stroke peak. In Arizona the leader pulse amplitudes are smaller than those in Florida, in relation to the return stroke, and are not as easy to identify. The shapes of the fields produced by normal steps are similar to dart steps, and the dart steps are very similar to regular sequences of pulses produced by many intracloud discharges. The 10-90% rise times of individual step wave forms are often less than 0.3 microsec, and the full width at half maximum of a step pulse is typically 0.4-0.5 microsec under conditions where the propagation distortion is minimal. The amplitudes and the shapes of leader step wave forms suggest that the peak step current is at least 2000-8000 A close to the ground and that the maximum rate of change of step current is 6-24 kA/microsec or larger. A rough estimate of the minimum charge lowered during the formation of a step is 0.001 to 0.004 C.