Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Laboratory studies of wave-current interaction - Kinematics of the strong interaction

Controlled laboratory experiments have been conducted to study the kinematics of wave-current interactions. The results confirm the conservation of waves under the steady state condition. The data also show that the kinematic effect of the current on waves can be treated as a simple Doppler shift. After the Doppler correction, the kinematics of the waves (either breaking or nonbreaking) follow the linear theory very well.

Lai, Ronald J.↗

Laboratory chemistry and stratospheric clouds

Results are presented from laboratory experiments on the chemistry of ice particles to study the role of HCl and ClONO2 from CFCs in stratospheric ozone depletion over Antarctica. It is found that gaseous HCl is scavenged with high efficiency by the ice and the gas phase chlorine nitrate may react with the HCL-containing ice to produce Cl2. Also, consideration is given ot the behavior of solid nitric acid trihydrate and sulfuric acid aerosols.

Molina, Mario J.↗

X-ray/VUV transmission gratings for astrophysical and laboratory applications

This paper describes the techniques used to fabricate deep-submicron-period transmission gratings for astrophysical and laboratory applications, with special attention given to the major steps involved in the transmission grating fabrication. These include the holographic lithography procedure used to pattern the master transmission grating, the fabrication of X-ray mask, the X-ray lithography step used to transfer the X-ray mask pattern into a substrate, and the electroplating of the substrate to form the final grating pattern. The various ways in which transmission gratings can be used in X-ray and VUV spectroscopy are discussed together with some examples of experiments reported in the literature.

Schattenburg, M. L.↗

Manual control of the Langley Laboratory telerobotic manipulator

Langley's new Laboratory Teleoperator Manipulator (LTM) provides manual control of seven-degree-of-freedom, replica, force-reflecting, master/slave manipulator arms in two arms simultaneously. This paper describes the LTM, its installation, and plans for a comparable evaluation study of various control input devices to the system. The comparison includes control using the system's master arms, six-degree-of-freedom hand controllers, minimasters, and a force-reflecting hand controller.

Hankins, Walter W., III↗

Laboratory comparison of continuous vs. binary phase-mostly filters

Recent developments in spatial light modulators have led to devices which are capable of continuous phase modulation, even if only over a limited range. One of these devices, the deformable mirror device is used, to compare the relative merits of binary and partially-continuous phase filters in a specific problem of pattern recognition by optical correlation. Each filter was physically limited to only about a radiation of modulation. Researchers have predicted that for low input noise levels, continuous phase-only filters should have a higher absolute correlator peak output than the corresponding binary filters, as well as having a larger SNR. When continuous and binary filters were implemented on the DMD and they exhibited the same performance; an ad hoc filter optimization procedure was developed for use in the laboratory. The optimized continuous filter gave higher correlation peaks than did an independently optimized binary filter. Background behavior in the correlation plane was similar for the two filters, and thus the SNR showed the same improvement for the continuous filter. A phasor diagram analysis and computer simulation have explained part of the optimization procedure's success.

Monroe, Stanley E., Jr.↗

Currents between tethered electrodes in a magnetized laboratory plasma

This paper describes the experimental setup and measurement techniques used to investigate currents between tethered electodes in a magnetized laboratory plasma. Experimental results include information on current propagation, the formation of wave wings, the limits of current collection, nonlinear effects and instabilities, charging phenomena, and the characteristics of transmission lines in plasma. The results were found to support certain predictions on tethers in space (e.g., the MHD far zone or the motional emf) while contradicting others (e.g., distant current closure), and revealed such new phenomena as current disruptions, current-neutralized beams, and wing spread.

Stenzel, R. L.↗

Laboratory simulations of energetic atom interactions occurring in low earth orbit

The Space Shuttle flights provided the first significant data base on the environment experienced by a large space structure operating in LEO. A number of interesting and unanticipated effects were observed, including material erosion induced by ambient oxygen atoms, the visible Shuttle glow occurring above surfaces exposed to the ram flow, and large near-field perturbations and variability in the gaseous neutral and plasma environment about the Shuttle. This paper provides a brief overview of these observations and their phenomenological interpretation, and then discusses laboratory approaches to their investigation. The emphasis is on the state of the art in the development of energetic oxygen atoms sources and the variety of experiments presently being performed with such devices.

Caledonia, G. E.↗

Laboratory results using the synthetic estimation filter

The synthetic estimation filter (SEF) was previously designed for implementation in an optical correlator. The intent was to find a simple method that would reduce the number of reference images necessary to track six degrees of freedom of an object, while avoiding the more complicated computations necessary in other methods of similar intent. Initial laboratory results are shown for estimating in-plane rotation with a minimal number of filters.

Monroe, Stanley E., Jr.↗

A laboratory measurement of CCD photometric and dimensional stability

The sun exhibits periodic and quasi-periodic variability in its total luminosity, which provides information about its internal structure and dynamics. Variability ranges from a few minutes to many-year time scales, with amplitudes as small as a few ppm in the milliHz band. Extension of this analysis to a large sample of outer stars would be interesting: a panoramic detector such as a CCD could record many stars at once. To meet this objective, a ppm time-series differential precision is required. Laboratory CCD photometric measurements presented here are promising for such an instrument. Normalizing the response from a portion of the CCD area removes most of the individual-frame variability. When a trend attributed to a thermal transient in the CCD dewar is removed, the individual-frame photometric precision is about 0.0001, limited by photoelectron counting statistics. The time-series power spectrum is flat within the desired frequency domain. Analysis of the dimensional stability of the CCD within the same data set indicates better than ppm performance, when first-order bulk motion and magnification changes are removed.

Buffington, Andrew↗

Modeling of induced currents from electrodynamic tethers in a laboratory plasma

The presently accepted picture of the current path for electrodynamic tethers envisions a quasi-dc current flow in a 'phantom loop' consisting of the tether, two field-aligned current channels into the ionosphere and a cross-field closing current in the E-layer. Predictions are made on the establishment and maintenance of a current loop in space based on observations of time-dependent currents between tethered electrodes in a large laboratory magnetoplasma. In addition to radiation from the contactors ('whistler wings'), the insulated tether is observed to emit waves (a 'whistler wedge'). The 'wedge' provides closure during loop formation by carrying cross-field polarization currents. Whistler spread within the ray cone leads to overlapping of the current wings not far from the tether hence minimizing the role of the ionospheric closure. Maintenance of the loop requires the continuous emission of whistler waves by the entire tether thereby providing severe radiation losses.

Urrutia, J. M.↗

Custom electronic subsystems for the laboratory telerobotic manipulator

The National Aeronautics and Space Administration (NASA) Space Station Program presents new opportunities for the application of telerobotic and robotic systems. The Laboratory Telerobotic Manipulator (LTM) is a highly advanced 7 degrees-of-freedom (DOF) telerobotic/robotic manipulator. It was developed and built for the Automation Technology Branch at NASA's Langley Research Center (LaRC) for work in research and to demonstrate ground-based telerobotic manipulator system hardware and software systems for future NASA applications in the hazardous environment of space. The LTM manipulator uses an embedded wiring design with all electronics, motor power, and control and communication cables passing through the pitch-yaw differential joints. This design requires the number of cables passing through the pitch/yaw joint to be kept to a minimum. To eliminate the cables needed to carry each pitch-yaw joint's sensor data to the VME control computers, a custom-embedded electronics package for each manipulator joint was developed. The electronics package collects and sends the joint's sensor data to the VME control computers over a fiber optic cable. The electronics package consist of five individual subsystems: the VME Link Processor, the Joint Processor and the Joint Processor power supply in the joint module, the fiber optics communications system, and the electronics and motor power cabling.

Glassell, R. L.↗

Database Access Manager for the Software Engineering Laboratory (DAMSEL) user's guide

Operating instructions for the Database Access Manager for the Software Engineering Laboratory (DAMSEL) system are presented. Step-by-step instructions for performing various data entry and report generation activities are included. Sample sessions showing the user interface display screens are also included. Instructions for generating reports are accompanied by sample outputs for each of the reports. The document groups the available software functions by the classes of users that may access them.

Source record↗

The cleanroom case study in the Software Engineering Laboratory: Project description and early analysis

This case study analyzes the application of the cleanroom software development methodology to the development of production software at the NASA/Goddard Space Flight Center. The cleanroom methodology emphasizes human discipline in program verification to produce reliable software products that are right the first time. Preliminary analysis of the cleanroom case study shows that the method can be applied successfully in the FDD environment and may increase staff productivity and product quality. Compared to typical Software Engineering Laboratory (SEL) activities, there is evidence of lower failure rates, a more complete and consistent set of inline code documentation, a different distribution of phase effort activity, and a different growth profile in terms of lines of code developed. The major goals of the study were to: (1) assess the process used in the SEL cleanroom model with respect to team structure, team activities, and effort distribution; (2) analyze the products of the SEL cleanroom model and determine the impact on measures of interest, including reliability, productivity, overall life-cycle cost, and software quality; and (3) analyze the residual products in the application of the SEL cleanroom model, such as fault distribution, error characteristics, system growth, and computer usage.

Green, Scott↗

Laboratory investigation of visible shuttle glow mechanisms

Laboratory experiments designed to uncover mechanistic information about the spectral and spatial characteristics of shuttle glow were conducted. The luminescence was created when a pulse of O atoms traveling at orbital velocities was directed toward NO molecules previously adsorbed to aluminum, nickel, and Z306 Chemglaz (a common baffle black) coated surfaces held at various temperatures. Spectral and spatial measurements were made using a CCD imaging spectrometer. Corroborative spectral information was recorded in separate measurements using a scanning monochromator and gated photomultiplier arrangement. The e-folding distance at several temperatures was calculated from images of the surface glow using the photometrics image processing capability of the imaging spectrometer. The e-folding distance was not altered as a function of incoming O beam velocity. The results are presented and the observations provide direct evidence that the visible shuttle glow results from recombination of oxygen atoms and surface bound NO.

Leone, A.↗

A model for the three-dimensional spacecraft control laboratory experiment

A model for the three-dimensional Spacecraft Control Laboratory Experiment (SCOLE) is developed. The objective behind this method of modelling is to utilize the basic partial differential equations of motion for this distributed parameter system and not to use the modal expansion in developing the model. The final model obtained is in terms of a transfer function matrix which relates the flexible mast parameters like displacement, slope, shear stress, etc. to external forces and moments.

Kakad, Yogendra P.↗

Laboratory test and acoustic analysis of cabin treatment for propfan test assessment aircraft

An aircraft cabin acoustic enclosure, built in support of the Propfan Test Assessment (PTA) program, is described. Helmholtz resonators were attached to the cabin trim panels to increase the sidewall transmission loss (TL). Resonators (448) were located between the trim panels and fuselage shell. In addition, 152 resonators were placed between the enclosure and aircraft floors. The 600 resonators were each tuned to a 235 Hz resonance frequency. After flight testing on the PTA aircraft, the enclosure was tested in the Kelly Johnson R and D Center Acoustics Lab. Laboratory noise reduction (NR) test results are discussed. The enclosure was placed in a Gulfstream 2 fuselage section. Broadband (138 dB overall SPL) and tonal (149 dB overall SPL) excitations were used in the lab. Tonal excitation simulated the propfan flight test excitation. The fundamental tone was stepped in 2 Hz intervals from 225 through 245 Hz. The resonators increase the NR of the cabin walls around the resonance frequency of the resonator array. The effects of flanking, sidewall absorption, cabin adsorption, resonator loading of trim panels, and panel vibrations are presented. Increases in NR of up to 11 dB were measured.

Kuntz, H. L.↗