Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

High spectral resolution remote sensing of the land

Spectral remote sensing has been practiced on a large scale since the launch of Landsat 1 in 1972. The limited information contained in this spectrally undersampled data set has led to the development of sophisticated statistical-inferential methods for data analysis. The results are usually limited by the availability of ground truth information. Recent technological developments have made it feasible to create narrow-band, contiguous, spectral image data sets that make possible the identification of surface cover materials based on the complete reflectance spectrum for each picture element. This capability will revolutionize the use of remote sensing data and require new deterministic image processing techniques to extract the full information content from the data. Sensors, based on the concept of imaging spectrometry and the new technology of area array infrared detectors, have been constructed and are candidates for Shuttle and space platform flights.

Goetz, A. F. H.↗

Halogen occultation experiment (HALOE) optical witness-plate program

An optical witness plate program was implemented to monitor buildup of molecular contamination in the clean room during the assembly and testing of the Halogen Occulation Experiment (HALOE) instrument. Travel plates to monitor molecular contamination when the instrument is not in the clean room are also measured. The instrument technique is high-resolution transmission spectroscopy in the 3 micron spectral region using a Fourier transform spectrometer. Witness specimens of low index of refraction, infrared transmitting material are used for contaminant monitoring and for spectral signature analysis. Spectral signatures of possible molecular contamination are presented. No condensible volatile material contamination of HALOE optical witness specimens have yet been found.

Harvey, Gale A.↗

Spectroscopic study of the seasonal variation of carbon monoxide vertical distribution above Kitt Peak

A method to retrieve elements of the carbon monoxide (CO) vertical distribution from ground-based high-resolution infrared solar spectra has been developed. The method is based on the fact that the total column amount retrieved by nonlinear least squares spectral fitting techniques depends on the shape of the assumed a priori profile and this dependence is a function of the absorption line intensity and the lower state energy of the transition. Four CO lines between 2057 and 2159/cm have been selected and the method has been tested on synthetic spectra. The CO total column content and average concentrations in two atmospheric layers (surface to 400 mbar and 400 mbar to the top of the atmosphere) can be retrieved with precisions of about 1% and less than 10%, respectively. Solar spectra recorded at Kitt Peak from 1982 to 1993 have been analyzed. The CO total column and the average concentration in the two layers show an asymmetrical seasonal cycle with extreme values of (1.1-2.1) x 10(exp 18) molecules cm(exp -2), (50-80) parts per billion by volume (ppbv) in the top layer and (80-160) ppbv in the bottom layer, and precisions of 1, 3, and 6%, respectively; a spring maximum and late summer minimum are observed.

Pougatchev, N. S.↗

Satellite Detection of Smoke Aerosols Over a Snow/Ice Surface by TOMS

The use of TOMS (Total Ozone Mapping Spectrometer) satellite data demonstrates the recently developed technique of using satellite UV radiance measurements to detect absorbing tropospheric aerosols is effective over snow/ice surfaces. Instead of the traditional single wavelength (visible or infrared) method of measuring tropospheric aerosols, this method takes advantage of the wavelength dependent reduction in the backscattered radiance due to the presence of absorbing aerosols over snow/ice surfaces. An example of the resulting aerosol distribution derived from TOMS data is shown for an August 1998 event in which smoke generated by Canadian forest fires drifts over and across Greenland. As the smoke plume moved over Greenland, the TOMS observed 380 nm reflectivity over the snow/ice surface dropped drastically from 90-100% down to 30-40%. To study the effects of this smoke plume in both the UV and visible regions of the spectrum, we compared a smoke-laden spectrum taken over Greenland by the high spectral resolution (300 to 800 nm) GOME instrument with one that is aerosol-free. We also discuss the results of modeling the darkening effects of various types of absorbing aerosols over snow/ice surfaces using a radiative transfer code. Finally, we investigated the history of such events by looking at the nearly twenty year record of TOMS aerosol index measurements and found that there is a large interannual variability in the amount of smoke aerosols observed over Greenland. This information will be available for studies of radiation and transport properties in the Arctic.

Hsu, N. Christina↗

Machine vision guided sensor positioning system for leaf temperature assessment

A sensor positioning system was developed for monitoring plants' well-being using a non-contact sensor. Image processing algorithms were developed to identify a target region on a plant leaf. A novel algorithm to recover view depth was developed by using a camera equipped with a computer-controlled zoom lens. The methodology has improved depth recovery resolution over a conventional monocular imaging technique. An algorithm was also developed to find a maximum enclosed circle on a leaf surface so the conical field-of-view of an infrared temperature sensor could be filled by the target without peripheral noise. The center of the enclosed circle and the estimated depth were used to define the sensor 3-D location for accurate plant temperature measurement.

NASA Discipline Life Support Systems↗

Determination of Lubricants on Ball Bearings by FT-IR using an Integrating Sphere

The lifetime determination of space lubricants is done at our facility by accelerated testing. Several micrograms of lubricant are deposited on the surface of a ball by syringing tens of micro liters of dilute lubricant solution. The solvent evaporates and the mass of lubricant is determined by twenty weighings near the balance reliability limit. This process is timely but does not produce a good correlation between the mass of lubricant and the volume of solution applied, as would be expected. The amount of lubricant deposited on a ball can be determined directly by Fourier Transform - Infrared Spectroscopy using an integrating sphere. In this paper, we discuss reasons for choosing this methodology, optimization of quantification conditions and potential applications for the technique. The volume of lubricant solution applied to the ball gives better correlation to the IR intensity than does the weight.

Street, K. W.↗

Trace Gas Measurements on Mars and Earth Using Optical Parametric Generation

Trace gases and their isotopic ratios in planetary atmospheres offer important but subtle clues as to the origins of a planet's atmosphere, hydrology, geology, and potential for biology. An orbiting laser remote sensing instrument is capable of measuring trace gases on a global scale with unprecedented accuracy, and higher spatial resolution that can be obtained by passive instruments. We have developed an active sensing instrument for the remote measurement of trace gases in planetary atmospheres (including Earth). The technique uses widely tunable, seeded optical parametric generation (OPG) to measure methane, CO2, water vapor, and other trace gases in the near and mid-infrared spectral regions. Methane is a strong greenhouse gas on Earth and it is also a potential biogenic marker on Mars and other planets. Methane in the Earth's atmosphere survives for a shorter time than CO2 but its impact on climate change can be larger than CO2. Methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but recent observations indicate that methane levels may be on the rise. Increasing methane concentrations may trigger a positive feedback loop and a subsequent runaway greenhouse effect, where increasing temperatures result in increasing methane levels. The NRC Decadal Survey recognized the importance of global observations of greenhouse gases and called for simultaneous CH4, CO, and CO2 measurements but also underlined the technological limitations for these observations. For Mars, methane measurements are of great interest because of its potential as a strong biogenic marker. A remote sensing instrument that can measure day and night over all seasons and latitudes can identify and localize sources of biogenic gas plumes produced by subsurface chemistry or biology, and aid in the search for extra-terrestrial life. It can identify the dynamics of methane generation over time and latitude and identify future lander mission sites for more detailed in-situ analysis. In this paper we report on remote sensing measurements of methane using a high peak power, widely tunable optical parametric generator (OPG) operating at 3.3 micron and 1.65 micron. The OPG is pumped by a passively q-switched single frequency laser (3ns, 5KHz, 50uJ) and seeded by a diode laser. The spectral width of both signal and idler of seeded OPG is nearly Fourier transform limited. The output of seeded OPG is single frequency with high spectral purity and is widely tunable. Both 1650 nm and 3300 nm can be generated with a conversion efficiency of more than 30%. We have demonstrated detection of methane at 3274 nm and 1650 nm in a cell and also performed open path atmospheric measurements of methane at the same wavelengths. Finally, we were able to demonstrate simultaneous detection of methane at 3270.4 nm and CO2 at 1578.2 nm. In this paper we will discuss the OPG performance and atmospheric open path measurement results.

Numata, Kenji↗

Exploring Extrasolar Planetary Systems: New Observations of Extrasolar Planets Enabled by the James Webb Space Telescope

The search for extrasolar planets has been increasingly success over the last few years. In excess of 700 systems are now known, and Kepler has approx.2500 additional candidate systems, yet to be confirmed. Recently, progress has also been made in directly imaging extrasolar planets, both from the ground and in space. In this presentation will discuss the techniques employed to discover planetary systems, and highlight the capabilities, enabled by the James Webb Space Telescope (JWST). JWST is a large 6.5 meter aperture infrared telescope that is scheduled for launch in 2018, and will allow us to transition to characterizing the properties of these extrasolar planets and the planetary systems in which they reside.

Clampin, Mark↗

Survey of Experimental Results in High-Contrast Imaging for Future Exoplanet Missions

We present and compare experimental results in high contrast imaging representing the state of the art in coronagraph and starshade technology. These experiments have been undertaken with the goal of demonstrating the capability of detecting Earth-like planets around nearby Sun-like stars. The contrast of an Earth seen in reflected light around a Sun-like star would be about 1.2 x 10(exp -10). Several of the current candidate technologies now yield raw contrasts of 1.0 x 10(exp -9) or better, and so should enable the detection of Earths, assuming a gain in sensitivity in post-processing of a factor of 10. We present results of coronagraph and starshade experiments conducted at visible and infrared wavelengths. Cross-sections of dark fields are directly compared as a function of field angle and bandwidth. The strength and differences of the techniques are compared.

starlight suppression↗

Multiwavelength monitoring of the BL Lacertae object PKS 2155-304. 4: Multiwavelength analysis

Simultaneous X-ray, ultraviolet, optical, infrared, and radio monitoring data were used to test and constrain models of continuum emission from the BL Lacertae object PKS 2155-304. Intensively sampled ultraviolet and soft X-ray light curves showed a clear temporal correlation with the X-rays leading the ultraviolet by 2-3 hr. This lag was found to be significantly different from zero after an exhaustive comparison of four different techniques for measuring temporal correlations. Variations in the ultraviolet trough optical wave bands were also strongly correlated, with no measurable lag down to limiting timescales of approximately less than 1-2 hr. This strong correlation extends to the near-infrared, but the less intensive sampling precludes measurement of any lag beyomnd an upper limit of approximately less than 1 day. These lags and limits of the order of hours are much shorter than most rapid observed single-band variations. Because of the very sparse radio sampling, it was not possible to measure quantitatively the correlation and lag with shorter wavelengths, but the data do suggest that the radio may lag the optical/ultraviolet by approximately 1 week, with longer delays and weaker variations to longer radio wavelengths. The epoch-folding Q(exp 2) statistic was used to test for periodicity, and no evidence for strict or quasi-periodicity was found in any of the light curves. Because they lead the lower frequencies, the soft X-rays (approximately less than 1 keV) cannot arise from synchrotron self-Compton scattering. These results also rule out the accretion disk model, which predicts a measurable lag between ultraviolet/optical wavelength bands and a correlation between hardness and brightness, neither of which were seen. They are consistent with the entire radio through X-ray continuum arising from direct synchrotron emission from a relativistic jet. However, the tapered jet model, in which the X-ray emission is produced closer in, has problems explaining the magnitude of the ultraviolet/X-ray lag, because the X-ray-emitting electrons have very short lifetimes (t(sub 1/2) much less than 1 s). The result that the lag is much smaller than the variability timescale suggests instead that the radiation may be produced in a flattened region such as a shock front.

Edelson, R.↗

Imaging Technique for High Precision Measurement of Detector Stability for the Ocean Color Instrument

One of the new projects by NASA to explore environmental change is the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft. The primary instrument aboard the PACE spacecraft is the Ocean Color Instrument (OCI), an advanced optical spectrometer that will measure the color of the ocean from the ultraviolet to shortwave infrared range for the purpose of observing and monitoring ocean and coastal biology. As part of the optical alignment testing that must be completed before the instrument is built, the measurement stability of the detectors at space flight operating temperatures must be determined to ensure alignment is maintained. Therefore, this project focuses on the development of an imaging technique that adheres to testing requirements and can be used to determine the stability of the OCI detector. The movements of targets affixed to a high-precision stage were analyzed through an image processing program to test the ability of the imaging technique to detect very small (under 10 micrometers) movements. It was found that movements as small as half a pixel (~6 microns) and 1 pixel (~12 microns) were able to be accurately and consistently detected with this imaging technique. This project found that the designed image analysis technique fulfills testing and measurement requirements and will be an effective metrology technique for the OCI detector stability test.

Optics↗

A comparison of remote sensing techniques for Minnesota wetlands classification

A wetland classification study in a typically complex 650 sq km test site in east central Minnesota compared the time, cost and accuracy of manually interpreted 1:24,000 scale color infrared aerial photographs with digital analysis of Landsat data. The comparison was between the same general wetland and non-wetland classes; accuracy of both systems was evaluated with intensive ground verification. For the same general classes, the overall mapping accuracy was 96 percent for the aerial photo interpretation and 71 percent for Landsat double-date classification. Results with maximum likelihood and SECHO classifiers were the same, 71 percent, while mapping accuracy with a layered classifier was only 66 percent. Compared to a general geometric correction and a single-date data set, geographic position and classification accuracy improved when a precision geometric correction and a double-date data set were used. Landsat digital analysis was faster, 24 vs. 90 days, but photointerpretation was more economical at $0.15/hectare (including all costs of procurement, processing and analysis), compared with Landsat costs of $0.35/hectare (not including costs of data procurement, processing prior to delivery to user and related overhead).

Werth, L. F.↗

Long-term 4.6 µm Variability in Brown Dwarfs and a New Technique for Identifying Brown Dwarf Binary Candidates

Using a sample of 361 nearby brown dwarfs, we have searched for 4.6 μm variability, indicative of large-scale rotational modulations or large-scale, long-term changes on timescales of over 10 yr. Our findings show no statistically significant variability in Spitzer's Infrared Array Camera (IRAC) channel 2 (ch2) or Wide-field Infrared Survey Explorer W2 photometry. For Spitzer the ch2 1σ limits are ∼8 mmag for objects at 11.5 mag and ∼22 mmag for objects at 16 mag. This corresponds to no variability above 4.5% at 11.5 mag and 12.5% at 16 mag. We conclude that highly variable brown dwarfs, at least two previously published examples of which have been shown to have 4.6 μm variability above 80 mmag, are very rare. While analyzing the data, we also developed a new technique for identifying brown dwarf binary candidates in Spitzer data. We find that known binaries have IRAC ch2 point response function (PRF) flux measurements that are consistently dimmer than aperture flux measurements. We have identified 59 objects that exhibit such PRF versus aperture flux differences and are thus excellent binary brown dwarf candidates.

Hunter Brooks↗

Multiplexed Readout of Thermal Bolometers with Superconducting Transition Edge Thermometers

History shows that in astronomy, more is better. In the near future, direct detector arrays for the far-infrared and submillimeter will contain hundreds to thousands of elements. A multiplexed readout is necessary for practical implementation of such arrays, and has been developed using SQUIDs. The technology permits a 32 x 32 array of bolometers to be read out using approximately 100 wires rather than the >2000 needed with direct wiring. These bolometer arrays are made by micromachining techniques, using superconducting transition edge sensors as the thermistors. We describe the development of this multiplexed superconducting bolometer array architecture as a step toward bringing about the first astronomically useful arrays of this design. This technology will be used in the Submillimeter and Far Infrared Experiment (SAFIRE) instrument on Stratospheric Observatory for Infrared Astronomy (SOFIA), and is a candidate for a wide variety of other spectroscopic and photometric instruments.

Benford, Dominic J.↗

Electron impact spectroscopy

The concepts of electron impact spectroscopy are discussed, comparing the electron spectroscopy techniques with those of the optical spectroscopy. The main advantage of the electron spectroscopy is to be found in the elimination of optical selection rules in excitation processes and the ability to scan the spectrum from the infrared to the X-ray region. The range of the method is indicated through a review of several examples, including electron impact excitation of Ba and rotational excitation of H2. The sensitivity of the method is demonstrated by vibrational excitation spectrum of N2. It is shown that the application of the method to the inner-shell excitation allows to obtain information about molecular species which are not commonly available, while spectroscopy of negative ions yields information about their energy and symmetry properties. However, the techniques are still under development and more data are expected to become available in the coming years.

Trajmar, S.↗

Techniques for carrying out radiative transfer calculations for the Martian atmospheric dust

A description is given of the modification of a theory on the reflectance of particulate media so as to apply it to analysis of the infrared spectra obtained by the IRIS instrument on Mariner 9. With the aid of this theory and the optical constants of muscovite mica, quartz, andesite, anorthosite, diopside pyroxenite, and dunite, modeling calculations were made to refine previous estimates of the mineralogical composition of the Martian dust particles. These calculations suggest that a feldspar rich mixture is a very likely composition for the dust particles. The optical constants used for anorthosite and diopside pyroxenite were derived during this program from reflectance measurements. Those for the mica were derived from literature reflectance data. Finally, a computer program was written to invert the measured radiance data so as to obtain the absorption coefficient spectrum which should then be independent of the temperature profile and gaseous component effects.

Aronson, J. R.↗