Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISAACS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Idle Tomography

presents basic premise of idle tomography as a procedure with modern understanding of error generators and very simple results

Ostrove, Corey Isaac↗

L3:RTM.MCH.P19.06: Neutronics UQ

This report summarizes some of the work performed in the last year on the nuclear data uncertainty tasks using the multipole representation. This approach was proposed to provide a simple and integrated way of evaluating the nuclear data uncertainty in a Monte Carlo simulation and evaluating their impact on multigroup cross sections. As previously described, the windowed multipole format allows for a resonance based representation of the cross sections with direct Doppler broadening. This representation also lends itself nicely to the evaluation of sensitivities of resonance parameters and the direct perturbation of resonance parameters in the simulation environment. Both of these approaches rely on the need of conversion of the covariance data (File 32 of the ENDF library) into a pole and residues form: i.e. into a multipole covariance. Section 5 details the current pathways that have been used so far to achieve this. In order to verify the conversion process of the covariance data, the sensitivies to the resonance parameters and the sampling from these parameters, an analytical benchmark of the slowing process was developed. The benchmark provides a closed-form solution for the flux in the presence of Hydrogen and multiple resonant nuclides. Section 2 details the analytical benchmark and provides the closed-form solutions for the flux and its sensitivity to resonance parameters. A verification of the proposed methodology is performed and compared with the analytic solution to demonstrate the accuracy of the benchmark and the applicability of our embedded resonance perturbation approach in a small Monte Carlo code. Papers are currently being drafted documenting the benchmark and the generation of sensitivities. As paths to best generate multipole covariance matrices are being compared, we also explored new methods to propagate nuclear data uncertainty across the Monte Carlo neutron transport calculation. Section 4 studies the use of multipole covariance matrices to perform sensitivity analysis. Section 3.2 documents the results of our investigations into a new way of propagating nuclear data uncertainty across Monte Carlo transport simulations by sampling new epistemic cross sections for each new neutron.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Driver Identification Midyear Report

First, we create a profile for each authorized driver based on their existing driving data. We then train a machine learning model on the driving data from this profile, yielding an individualized model for each driver. Finally during a drive, we pass the Controller Area Network (CAN) data to the model and authen ticate the driver’s identity in real-time. This verification or lack thereof could be used to alert supervisors of threats to their drivers or transported materials. Deviations from their normal driving behavior could indicate high-risk situations, medical events, or even insider threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Survey Report on Commercial Off-The-Shelf (COTS) Tracking Tools

Radioactive/nuclear (R/N) materials are integral parts of many business sectors such as medicine, industry, and research. In the United States alone, approximately 3 million packages containing R/N materials are shipped annually via highways, rail, air, and water. These materials are utilized in medical diagnostics and treatments, industrial radiography, and scientific research. The secure and efficient transportation of R/N materials is paramount to public safety and national security. Recent incidents involving the loss of R/N materials during transportation highlight significant security and safety concerns. For instance, in December 2024, a package containing four encapsulated Selenium-75 sources was reported lost in transit from the Czech Republic to Madrid, raising alarms about the security of such shipments. Similarly, a Germanium-68 pin source was reported lost in transit in New Jersey in December 2024, underscoring the risks associated with transporting radioactive materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Beam Tuning Setups for Drift Tube Linacs

Various matching methods for tuning Drift Tube Linacs are overviewed. Special emphasis is on the methods utilizing signature phase scans with single and pairs of Beam Position Monitors (BPM) placed inside or outside of the tuned-up cavity, and that using a combination of phase scans with energy scans.

43 PARTICLE ACCELERATORS↗

LANSCE Accelerator Modernization Project Conceptual Design Report

The accelerator complex now known as the Los Alamos Neutron Science Center (LANSCE) began operation in 1972 as LAMPF, the Los Alamos Meson Production Facility. In the intervening 53 years, the complex has been expanded in capability several times, both in terms of its accelerator performance and the user facilities it supports.

43 PARTICLE ACCELERATORS↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

Evaluation of Glovebox Fires Involving Flammable Liquids and Standard Glovebox Tools (Final Report)

This research effort was commissioned to examine factors related to loss of containment due to fire within a glovebox (GB). Tests consisted of multiple trials with varying initial conditions. Com bustible levels and types were chosen to reflect realistic operation conditions (including worst-case scenarios), involving flammable liquids, GB tools, and other combustible items commonly found in GBs at Los Alamos National Labs (LANL).

42 ENGINEERING↗

Evaluation of Glovebox Glove Material Integrity Under Thermal Insult (Final Report)

The results of the experiments presented above are summarized in Table 1. Timing of critical events, such as appearance of bubbles on the specimen surface and rupture are noted. Relevant temperature and pressure data are also summarized. These results indicate a few critical aspects of the response of Hypalon glove material when exposed to a high temperature environment. Glove specimens began to show changes in surface appearance (appearance of bubbles on surface) when the temperature at the specimen surface was 530 ± 32 °F, regardless of specimen thickness. The bubbles are likely the result of the glove material decomposing and off-gassing. In the case of the 15 mil thickness gloves, specimens ruptured shortly after bubbling was observed. The ruptures are likely the result the bubbles growing in size, eventually forming pinholes through the thickness of the specimen. It should be noted that the specimens did not need to ignite in order to cause a perforation of the specimen. Specimens located 10, 11 and 12 inches from the burner ruptured, while the specimen located 14 inches from the burner did not rupture; in fact no change in surface appearance was observed. The 30 mil thickness specimens exhibited a different post-bubble response with only the specimen located 10 inches from the burner (i.e. highest surface temperature) resulting in rupture. There was a longer delay between surface bubbling and rupture than was observed in the 15 mil thickness specimens. This specimen also ignited before the specimen ruptured. While the 30 mil thickness specimens located 11 and 12 inches from the burner did show surface bubbling corresponding to thermal breakdown, neither specimen ruptured. Examination of the specimens after testing revealed that a slightly hard layer of melted material had formed on the rear of the specimen. This layer may have acted to seal the rear surface of the specimen by forming a barrier that bubbles could not penetrate. The specimen located 14 inches from the burner did not rupture, and did not exhibit any change in surface characteristics. In general the 30 mil thickness glove materials proved more resistant to thermal-induced rupturing as compared with the 15 mil thickness glove material. It was shown to be possible to rupture a 15 mil thick glove without igniting the glove, while the only test case that resulted in a rupture of a 30 mil thickness specimen also showed the specimen igniting several seconds before eventual rupture. Furthermore, it was observed that 30 mil thickness specimens could be exposed to temperatures high enough to cause decomposition (bubbling), yet not rupture. Thus, it is possible that the 30 mil gloves rupture by burning through the specimen material, while the 15 mil thickness specimens could be ruptured by small bubbles formed by thermal off-gassing expanding and causing pinholes through the specimen thickness. We also note that thermal decomposition and the appearance of surface bubbles was observed in all experiments with a maximum temperature exceeding ∼500 °F. Lastly, we can state that specimens subjected to temperatures below 400 °F experienced no thermal damage, staying below this threshold should prevent damage and potential rupture of either thickness glove materials.

42 ENGINEERING↗

Test Report: Glovebox Test Fire for Evaluation of Effects on Containers and Windows

This test report describes a designed Glovebox (GB) fire to identify target environmental conditions that GB containers and windows are subject to such fires. The fire was designed by representatives from the Los Alamos National Laboratory (LANL) to replicate a realistic worst-case fire scenario at LANL. Key results of these experiments include: • The GB fire was active for more than 30 minutes. • Thermocouples were placed at multiple points in the GB were measured, including one on top of the container. Temperatures at varied widely as a function of location during the fires, as might be expected and as a function of proximity to fire, elevation in the GB, and in relation airflow present during the test, which constantly introduces room-temperature air into the GB. The maximum temperature recorded by a thermocouple was slightly less than 500°F at the elevation of the highest gloveports and near, but not in contact with the GB wall. • A thermographic camera imaged the region of the GB container during the fire. These data report container temperatures of up to approximately 900°F (482°C) over a period of several minutes. • Four kilograms of lead shot were held in the container. The majority of the shot melted during the course of the fire (lead melting point: 621°F/327°C). • Multiple windows fractured during the test. In some cases, the polymer interlayer of the laminated GB window glass appears to have sustained damage due to thermal breakdown of the polymer, though the interlayer of the laminated GB window glass appears to have remained intact in all cases. • The one window with an attached thermocouple was less affected by the fire. The attached thermocouple measured up to approximately 150°F. • Other thermocouples along (but not in contact with) the GB wall and closer to the fire (and cracked windows) reported up to approximately 200°C (392° F). These finding suggest that subjecting containers to 500°C for 45 minutes is bounding and representative for fires of this type. It should also be noted that 500°C (932°F) has been previously used as a test criterion for related work. Similarly, 200°C may be a reasonable target temperature for GB windows subjected to fires of this type.

42 ENGINEERING↗

Sensos Smart Label Performance Summary as Observed by Oak Ridge National Laboratory

The Oak Ridge National Laboratory (ORNL) team performed an evaluation of the Sensos Smart Label Gen 2.0, as shown in Figure 1, for package tracking. A long-distance round-trip shipment between Oak Ridge, Tennessee, and Seattle, Washington, was completed to assess the device’s performance in location tracking, environment sensing capabilities, alerting features, threshold options, battery life, and real-time and historical data retrieval from the “Sync” data dashboard provided by Sensos. The evaluation was conducted to gain a general understanding of the capabilities of the device. Furthermore, due to time and resource constraints, ORNL did not conduct exhaustive testing to confirm reliability, availability, or effectiveness of alerting and tracking features. On equipment arrangement, Sensos (sensos.ai) graciously agreed to provide a Sensos Smart Label Gen 2.0 device to ORNL, at no cost, for testing and evaluation purposes. ORNL conducted assessments along with other commercial off-the-shelf (COTS) tracking devices. As a courtesy, ORNL will provide Sensos with this report summarizing the observations and findings specific to the Sensos label based on the tests performed.