Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

In-situ X-ray diffraction measurements of the [gamma-epsilon] transition boundary of iron in an internally-heated diamond anvil cell

The phase transition boundary between the {gamma} (face-centered cubic structure) and {epsilon} (hexagonal close-packed structure) iron phases was determined up to 69 GPa by using a newly developed internally-heated diamond anvil cell, combined with in-situ synchrotron X-ray diffraction measurements. The improved experimental configuration provides stable heating with reliable temperature and pressure determination and phase identification. A simultaneous laser- and internal-heating system was also used to produce further higher temperature at higher pressures. The sample pressure at any given temperature was calculated using an established thermal equation of state for {epsilon} iron. The {gamma}-{epsilon} transition boundary was bracketed with the normal and reversal directions and it is linear from 21 to 69 GPa with a dP/dT slope of 0.0394 GPa/K. There is no evidence for the existence of additional iron solid phase other than the {gamma} and {epsilon} phases over the P-T range of this study. We inferred that the {gamma}-{epsilon}-liquid triple point of iron should occur at 88 GPa and 2800 K.

36 MATERIALS SCIENCE↗

Enhanced internal condensation of R1233zd(E) on micro- and nanostructured copper and aluminum surfaces

In-tube condensation of refrigerants is an important process which affects thermal efficiency in many applications, ranging from refrigeration and air conditioning to electronics thermal management. In-tube heat transfer and pressure drop are important to heat exchanger sizing and design. Here, in this work, micro- and nanostructured surfaces are applied to the internal wetted areas of copper and aluminum mini-channels to enhance the condensation heat transfer coefficient of hydrofluorocarbon R1233zd(E) refrigerant. To achieve scalable nanomanufacturing, surfaces were uniformly structured by relying on hydrochloric acid etching of aluminum and chemical oxidation of copper. The etched aluminum surfaces exhibited a 150% increase in heat transfer coefficient compared to smooth aluminum channels at specific qualities, with a 66% heat transfer coefficient improvement for complete phase change from saturated vapor to saturated liquid. Copper oxide structures showed no discernable difference in thermal-hydraulic performance when compared to smooth copper channels. Critical dimensionless parameters governing the heat transfer enhancement were identified by varying the tube internal diameter (2.3 mm to 4.7 mm), refrigerant mass flux (50 to 300 kg/(m 2 ·s)), and refrigerant quality (0 to 1). The dimensionless parameters include the Bond number normalized to the condensate film thickness, and the Weber number modified by the vapor friction factor. The relatively small increase in pressure drop (< 10%) associated with these surface enhancements further supports the promise of this method. The scalable and cost-effective techniques used to create these aluminum microstructures may reduce manufacturing cost when compared with current enhancement approaches such as extrusion, drawing, and welding.

42 ENGINEERING↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P{sub mean}), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performed for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 {+-} 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P{sub mean} and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 {+-} 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 {+-} 1.1 mm distant from P{sub mean}. Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinically Apparent Internal Mammary Nodal Metastasis in Patients With Advanced Breast Cancer: Incidence and Local Control

Purpose: To investigate the incidence and local control of internal mammary lymph node metastases (IMN+) in patients with clinical N2 or N3 locally advanced breast cancer. Methods and Materials: We retrospectively reviewed the records of 809 breast cancer patients diagnosed with advanced nodal disease (clinical N2-3) who received radiation treatment at our institution from January 2000 December 2006. Patients were considered IMN+ on the basis of imaging studies. Results: We identified 112 of 809 patients who presented with IMN+ disease (13.8%) detected on ultrasound, computed tomography (CT), positron emission tomography/CT (PET/CT), and/or magnetic resonance imaging (MRI) studies. All 112 patients with IMN+ disease received anthracycline and taxane-based chemotherapy. Neoadjuvant chemotherapy (NCT) resulted in a complete response (CR) on imaging studies of IMN disease in 72.1% of patients. Excluding 16 patients with progressive disease, 96 patients received adjuvant radiation to the breast or the chest wall and the regional lymphatics including the IMN chain with a median dose of 60 Gy if the internal mammary lymph nodes normalized after chemotherapy and 66 Gy if they did not. The median follow-up of surviving patients was 41 months (8-118 months). For the 96 patients able to complete curative therapy, the actuarial 5-year IMN control rate, locoregional control, overall survival, and disease-free survival were 89%, 80%, 76%, and 56%. Conclusion: Over ten percent of patients with advanced nodal disease will have IMN metastases on imaging studies. Multimodality therapy including IMN irradiation achieves excellent rates of control in the IMN region and a DFS of more than 50% after curative treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Imaging by Megavoltage Computed Tomography for Assessment of Internal Organ Motion During Radiotherapy for Cervical Cancer

Purpose: To assess the internal organ motion of the cervix and uterus by megavoltage computed tomography (MVCT) during intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten patients with Stage IIB-IVA cervical cancer underwent daily MVCT imaging. Internal organ motion was evaluated on 150 pretreatment MVCT images by measuring shifts in their boundaries between the MVCT and kilovoltage (kV) planning CT scan in the anterior, posterior, left and right lateral, and superior and inferior direction. Additional intrafractional patient movement was evaluated on 50 posttreatment MVCT images. Results: Measured cervical motion (mean {+-} SD) was 0.4 {+-} 10.1 mm in the anterior, -3.0 {+-} 6.9 mm in the posterior direction, -3.5 {+-} 4.9 mm in the left and 0.2 {+-} 4.5 mm in the right lateral direction, 2.2 {+-} 8.0 mm in the superior and 0.5 {+-} 5.0 mm in the inferior direction. Compared to the cervix, larger uterine motion was observed. Patient movement during treatment was limited to 1.1 {+-} 1.3 mm, -0.3 {+-} 1.6 mm, and 0.2 {+-} 2.3 mm in anteroposterior, laterolateral and superoinferior direction respectively. Conclusions: MVCT imaging can be used to study patient setup accuracy and cervical and uterine motion during IMRT. This data may be used to refine treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Selection and Activity Planning Guide for Selective Internal Radiotherapy With Yttrium-90 Resin Microspheres

Purpose: Selective internal radiotherapy (SIRT) with yttrium-90 ({sup 90}Y) resin microspheres can improve the clinical outcomes for selected patients with inoperable liver cancer. This technique involves intra-arterial delivery of {beta}-emitting microspheres into hepatocellular carcinomas or liver metastases while sparing uninvolved structures. Its unique mode of action, including both {sup 90}Y brachytherapy and embolization of neoplastic microvasculature, necessitates activity planning methods specific to SIRT. Methods and Materials: A panel of clinicians experienced in {sup 90}Y resin microsphere SIRT was convened to integrate clinical experience with the published data to propose an activity planning pathway for radioembolization. Results: Accurate planning is essential to minimize potentially fatal sequelae such as radiation-induced liver disease while delivering tumoricidal {sup 90}Y activity. Planning methods have included empiric dosing according to degree of tumor involvement, empiric dosing adjusted for the body surface area, and partition model calculations using Medical Internal Radiation Dose principles. It has been recommended that at least two of these methods be compared when calculating the microsphere activity for each patient. Conclusions: Many factors inform {sup 90}Y resin microsphere SIRT activity planning, including the therapeutic intent, tissue and vasculature imaging, tumor and uninvolved liver characteristics, previous therapies, and localization of the microsphere infusion. The influence of each of these factors has been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Update of the International Consensus on Palliative Radiotherapy Endpoints for Future Clinical Trials in Bone Metastases

Purpose: To update the international consensus on palliative radiotherapy endpoints for future clinical trials in bone metastases by surveying international experts regarding previous uncertainties within the 2002 consensus, changes that may be necessary based on practice pattern changes and research findings since that time. Methods and Materials: A two-phase survey was used to determine revisions and new additions to the 2002 consensus. A total of 49 experts from the American Society for Radiation Oncology, the European Society for Therapeutic Radiology and Oncology, the Faculty of Radiation Oncology of the Royal Australian and New Zealand College of Radiologists, and the Canadian Association of Radiation Oncology who are directly involved in the care of patients with bone metastases participated in this survey. Results: Consensus was established in areas involving response definitions, eligibility criteria for future trials, reirradiation, changes in systemic therapy, radiation techniques, parameters at follow-up, and timing of assessments. Conclusion: An outline for trials in bone metastases was updated based on survey and consensus. Investigators leading trials in bone metastases are encouraged to adopt the revised guideline to promote consistent reporting. Areas for future research were identified. It is intended for the consensus to be re-examined in the future on a regular basis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Quality Assurance Review of External Beam Radiation Therapy in the International Society of Paediatric Oncology (Europe) Neuroblastoma Group's High-risk Neuroblastoma Trial: A SIOPEN Study

Purpose: Radiation therapy is important for local control in neuroblastoma. This study reviewed the compliance of plans with the radiation therapy guidelines of the International Society of Paediatric Oncology (Europe) Neuroblastoma Group (SIOPEN) High-Risk Trial protocol. Methods and Materials: The SIOPEN trial central electronic database has sections to record diagnostic imaging and radiation therapy planning data. Individual centers may upload data remotely, but not all centers involved in the trial chose to use this system. A quality scoring system was devised based on how well the radiation therapy plan matched the protocol guidelines, to what extent deviations were justified, and whether adverse effects may result. Central review of radiation therapy planning was undertaken retrospectively in 100 patients for whom complete diagnostic and treatment sets were available. Data were reviewed and compared against protocol guidelines by an international team of radiation oncologists and radiologists. For each patient in the sample, the central review team assigned a quality assurance score. Results: It was found that in 48% of patients there was full compliance with protocol requirements. In 29%, there were deviations for justifiable reasons with no likely long-term adverse effects resulting. In 5%, deviations had occurred for justifiable reasons, but that might result in adverse effects. In 1%, there was a deviation with no discernible justification, which would not lead to long-term adverse events. In 17%, unjustified deviations were noted, with a risk of an adverse outcome resulting. Conclusions: Owing to concern over the proportion of patients in whom unjustified deviations were observed, a protocol amendment has been issued. This offers the opportunity for central review of radiation therapy plans before the start of treatment and the treating clinician a chance to modify plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Esophageal Fiducial Marker Displacement During Radiation Therapy With a 2-dimensional On-board Imager: Analysis of Internal Margin for Esophageal Cancer

Purpose: To quantify the interfraction displacement of esophageal fiducial markers for primary esophageal cancer radiation therapy. Methods and Materials: Orthogonal 2-dimensional (2D) matching records fused to vertebrae were analyzed in clinically staged T1/2N0 esophageal cancer patients undergoing endoscopic clipping as fiducial metal markers. Displacement of the markers between the digitally reconstructed radiographs and on-board kilovoltage images during radiation therapy was analyzed according to direction and esophageal site. Results: Forty-four patients, with 81 markers (10 proximal, 42 middle, and 29 distal), underwent 367 2D matching sessions during radiation therapy. The mean (SD) absolute marker displacement was 0.26 (0.30) cm in the right–left (RL), 0.50 (0.39) cm in the superior–inferior (SI), and 0.24 (0.21) cm in the anterior–posterior (AP) direction. Displacement was significantly larger in the SI than in the RL and AP directions (P<.0001). In the SI direction, mean absolute displacements of the distal, middle, and proximal esophagus were 0.67 (0.45) cm, 0.42 (0.32) cm, and 0.36 (0.30) cm, respectively. Distal esophagus displacement was significantly larger than those of the middle and proximal esophagus (P<.0001). The estimated internal margin to cover 95% of the cases was 0.75 cm in the RL and AP directions. In the SI direction, the margin was 1.25 cm for the proximal and middle esophagus and 1.75 cm for the distal esophagus. Conclusions: The magnitude of interfraction displacement of esophageal clips was larger in the SI direction, particularly in the distal esophagus, but substantial displacement was observed in other directions and at other esophageal sites. It is practical to take estimated movements into account with internal margins, even if vertebrae-based 2D matching is performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining an Imaging Literacy Curriculum for Radiation Oncologists: An International Delphi Study

Purpose: Rapid evolution of imaging technologies and their integration into radiation therapy practice demands that radiation oncology (RO) training curricula be updated. The purpose of this study was to develop an entry-to-practice image literacy competency profile. Methods and Materials: A list of 263 potential imaging competency items were assembled from international objectives of training. Expert panel eliminated redundant or irrelevant items to create a list of 97 unique potential competency items. An international 2-round Delphi process was conducted with experts in RO. In round 1, all experts scored, on a 9-point Likert scale, the degree to which they agreed an item should be included in the competency profile. Items with a mean score ≥7 were included, those 4 to 6 were reviewed in round 2, and items scored <4 were excluded. In round 2, items were discussed and subsequently ranked for inclusion or exclusion in the competency profile. Items with >75% voting for inclusion were included in the final competency profile. Results: Forty-nine radiation oncologists were invited to participate in round 1, and 32 (65%) did so. Participants represented 24 centers in 6 countries. Of the 97 items ranked in round 1, 80 had a mean score ≥7, 1 item had a score <4, and 16 items with a mean score of 4 to 6 were reviewed and rescored in round 2. In round 2, 4 items had >75% of participants voting for inclusion and were included; the remaining 12 were excluded. The final list of 84 items formed the final competency profile. The 84 enabling competency items were aggregated into the following 4 thematic groups of key competencies: (1) imaging fundamentals (42 items); (2) clinical application (27 items); (3) clinical management (5 items); and (4) professional practice (10 items). Conclusions: We present an imaging literacy competency profile which could constitute the minimum training standards in radiation oncology residency programs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

More Accurate Definition of Clinical Target Volume Based on the Measurement of Microscopic Extensions of the Primary Tumor Toward the Uterus Body in International Federation of Gynecology and Obstetrics Ib-IIa Squamous Cell Carcinoma of the Cervix

Purpose: To more accurately define clinical target volume for cervical cancer radiation treatment planning by evaluating tumor microscopic extension toward the uterus body (METU) in International Federation of Gynecology and Obstetrics stage Ib-IIa squamous cell carcinoma of the cervix (SCCC). Patients and Methods: In this multicenter study, surgical resection specimens from 318 cases of stage Ib-IIa SCCC that underwent radical hysterectomy were included. Patients who had undergone preoperative chemotherapy, radiation, or both were excluded from this study. Microscopic extension of primary tumor toward the uterus body was measured. The association between other pathologic factors and METU was analyzed. Results: Microscopic extension toward the uterus body was not common, with only 12.3% of patients (39 of 318) demonstrating METU. The mean (±SD) distance of METU was 0.32 ± 1.079 mm (range, 0-10 mm). Lymphovascular space invasion was associated with METU distance and occurrence rate. A margin of 5 mm added to gross tumor would adequately cover 99.4% and 99% of the METU in the whole group and in patients with lymphovascular space invasion, respectively. Conclusion: According to our analysis of 318 SCCC specimens for METU, using a 5-mm gross tumor volume to clinical target volume margin in the direction of the uterus should be adequate for International Federation of Gynecology and Obstetrics stage Ib-IIa SCCC. Considering the discrepancy between imaging and pathologic methods in determining gross tumor volume extent, we recommend a safer 10-mm margin in the uterine direction as the standard for clinical practice when using MRI for contouring tumor volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pudendal Nerve and Internal Pudendal Artery Damage May Contribute to Radiation-Induced Erectile Dysfunction

Purpose/Objectives: Erectile dysfunction is common after radiation therapy for prostate cancer; yet, the etiopathology of radiation-induced erectile dysfunction (RI-ED) remains poorly understood. A novel animal model was developed to study RI-ED, wherein stereotactic body radiation therapy (SBRT) was used to irradiate the prostate, neurovascular bundles (NVB), and penile bulb (PB) of dogs. The purpose was to describe vascular and neurogenic injuries after the irradiation of only the NVB or the PB, and after irradiation of all 3 sites (prostate, NVB, and PB) with varying doses of radiation. Methods and Materials: Dogs were treated with 50, 40, or 30 Gy to the prostate, NVB, and PB, or 50 Gy to either the NVB or the PB, by 5-fraction SBRT. Electrophysiologic studies of the pudendal nerve and bulbospongiosus muscles and ultrasound studies of pelvic perfusion were performed before and after SBRT. The results of these bioassays were correlated with histopathologic changes. Results: SBRT caused slowing of the systolic rise time, which corresponded to decreased arterial patency. Alterations in the response of the internal pudendal artery to vasoactive drugs were observed, wherein SBRT caused a paradoxical response to papaverine, slowing the systolic rise time after 40 and 50 Gy; these changes appeared to have some dose dependency. The neurofilament content of penile nerves was also decreased at high doses and was more profound when the PB was irradiated than when the NVB was irradiated. These findings are coincident with slowing of motor nerve conduction velocities in the pudendal nerve after SBRT. Conclusions: This is the first report in which prostatic irradiation was shown to cause morphologic arterial damage that was coincident with altered internal pudendal arterial tone, and in which decreased motor function in the pudendal nerve was attributed to axonal degeneration and loss. Further investigation of the role played by damage to these structures in RI-ED is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Radiation Therapy for Primary Cutaneous Lymphomas: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group

Primary cutaneous lymphomas are a heterogeneous group of diseases. They often remain localized, and they generally have a more indolent course and a better prognosis than lymphomas in other locations. They are highly radiosensitive, and radiation therapy is an important part of the treatment, either as the sole treatment or as part of a multimodality approach. Radiation therapy of primary cutaneous lymphomas requires the use of special techniques that form the focus of these guidelines. The International Lymphoma Radiation Oncology Group has developed these guidelines after multinational meetings and analysis of available evidence. The guidelines represent an agreed consensus view of the International Lymphoma Radiation Oncology Group steering committee on the use of radiation therapy in primary cutaneous lymphomas in the modern era.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Radiation Therapy for Extranodal Lymphomas: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group

Extranodal lymphomas (ENLs) comprise about a third of all non-Hodgkin lymphomas (NHL). Radiation therapy (RT) is frequently used as either primary therapy (particularly for indolent ENL), consolidation after systemic therapy, salvage treatment, or palliation. The wide range of presentations of ENL, involving any organ in the body and the spectrum of histological sub-types, poses a challenge both for routine clinical care and for the conduct of prospective and retrospective studies. This has led to uncertainty and lack of consistency in RT approaches between centers and clinicians. Thus far there is a lack of guidelines for the use of RT in the management of ENL. This report presents an effort by the International Lymphoma Radiation Oncology Group (ILROG) to harmonize and standardize the principles of treatment of ENL, and to address the technical challenges of simulation, volume definition and treatment planning for the most frequently involved organs. Specifically, detailed recommendations for RT volumes are provided. We have applied the same modern principles of involved site radiation therapy as previously developed and published as guidelines for Hodgkin lymphoma and nodal NHL. We have adopted RT volume definitions based on the International Commission on Radiation Units and Measurements (ICRU), as has been widely adopted by the field of radiation oncology for solid tumors. Organ-specific recommendations take into account histological subtype, anatomy, the treatment intent, and other treatment modalities that may be have been used before RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Guidelines for Preoperative Radiation Therapy for Retroperitoneal Sarcoma: Preliminary Consensus of an International Expert Panel

Purpose: Evidence for external beam radiation therapy (RT) as part of treatment for retroperitoneal sarcoma (RPS) is limited. Preoperative RT is the subject of a current randomized trial, but the results will not be available for many years. In the meantime, many practitioners use preoperative RT for RPS, and although this approach is used in practice, there are no radiation treatment guidelines. An international expert panel was convened to develop consensus treatment guidelines for preoperative RT for RPS. Methods and Materials: An expert panel of 15 academic radiation oncologists who specialize in the treatment of sarcoma was assembled. A systematic review of reports related to RT for RPS, RT for extremity sarcoma, and RT-related toxicities for organs at risk was performed. Due to the paucity of high-quality published data on the subject of RT for RPS, consensus recommendations were based largely on expert opinion derived from clinical experience and extrapolation of relevant published reports. It is intended that these clinical practice guidelines be updated as pertinent data become available. Results: Treatment guidelines for preoperative RT for RPS are presented. Conclusions: An international panel of radiation oncologists who specialize in sarcoma reached consensus guidelines for preoperative RT for RPS. Many of the recommendations are based on expert opinion because of the absence of higher level evidence and, thus, are best regarded as preliminary. We emphasize that the role of preoperative RT for RPS has not been proven, and we await data from the European Organization for Research and Treatment of Cancer (EORTC) study of preoperative radiotherapy plus surgery versus surgery alone for patients with RPS. Further data are also anticipated pertaining to normal tissue dose constraints, particularly for bowel tolerance. Nonetheless, as we await these data, the guidelines herein can be used to establish treatment uniformity to aid future assessments of efficacy and toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Medical Graduates in Radiation Oncology: Historical Trends and Comparison With Other Medical Specialties

Purpose: This is the first National Resident Matching Program analysis evaluating historical patterns of international medical graduates (IMGs) in radiation oncology (RO) and providing comparison with American (MD) medical graduates (AMGs), osteopathic students (DOs), unfilled positions, and other specialties. Methods and Materials: National Resident Matching Program data for IMGs were available from 2003 to 2015, with limited data for other specialty matches. The following RO-specific figures were obtained per year: total positions available; total matched positions; number of unfilled positions; and number of IMG, AMG, and DO matches. In addition, the number of IMG matches and total matched positions were obtained for 19 other specialties. Fisher exact tests and χ{sup 2} tests were considered significant at α <.05. Results: From 2010 to 2015, 0.8% of RO matches were IMGs, a decline from 2.4% in 2003 to 2009 (P=.006). Proportions of DO matches during these intervals increased by 40% (from 1.0% to 1.4%), significantly lower than IMGs for 2003 to 2009 (P=.03) but not 2010 to 2015 (P=.26). From 2003 to 2015, the percentage of IMG matches, at 1.5%, was significantly lower than the percentage of unfilled seats, at 3.5% (P<.001). In comparison with other specialties (2003-2015), RO had the fewest IMG matches (1.5%), followed by otolaryngology (1.9%) and orthopedics (2.2%); specialties with the highest IMG proportions were internal medicine (37.1%), family medicine (35.7%), and neurology (31.1%). Conclusions: Presently, IMGs represent <1% of RO matches, the lowest among major specialties. There are several speculative factors associated with this low proportion. There are significantly more unfilled positions than those filled by IMGs; programs at risk of not matching could weigh the advantages and disadvantages of interviewing IMGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiosurgery for Brainstem Metastases: An International Cooperative Study to Define Response and Toxicity

Purpose: To pool data across multiple institutions internationally and report on the cumulative experience of brainstem stereotactic radiosurgery (SRS). Methods and Materials: Data on patients with brainstem metastases treated with SRS were collected through the International Gamma Knife Research Foundation. Clinical, radiographic, and dosimetric characteristics were compared for factors prognostic for local control (LC) and overall survival (OS) using univariate and multivariate analyses. Results: Of 547 patients with 596 brainstem metastases treated with SRS, treatment of 7.4% of tumors resulted in severe SRS-induced toxicity (grade ≥3, increased odds with increasing tumor volume, margin dose, and whole-brain irradiation). Local control at 12 months after SRS was 81.8% and was improved with increasing margin dose and maximum dose. Overall survival at 12 months after SRS was 32.7% and impacted by age, gender, number of metastases, tumor histology, and performance score. Conclusions: Our study provides additional evidence that SRS has become an option for patients with brainstem metastases, with an excellent benefit-to-risk ratio in the hands of experienced clinicians. Prior whole-brain irradiation increases the risk of severe toxicity in brainstem metastasis patients undergoing SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗