Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

WE-AB-201-03: TPS Commissioning and QA: Incorporating the Entire Planning Process

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

WE-AB-201-04: The Recommendations of MPPG #5 and Practical Implementation Strategies

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

Outage managment and health physics issue, 2008

The focus of the May-June issue is on outage management and health physics. Major articles include: Outage optimization initiatives, by George B. Beam, AREVA NP, Inc.; New plant based on excellent track records, by Jim Scarola, Progress Energy; Meeting customer needs and providing environmental benefits, by Peter S. Hastings, Duke Energy; Plants with 3-D design, by Jack A. Bailey, Tennessee Valley Authority; and Highest quality with exceptional planning, by Jason A. Walls, Duke Energy. Industry innovation articles include: Integrated exposure reduction plan, by Ed Wolfe, Exelon; Performance-based radiation worker training, by Joe Giuffre and Timothy Vriezerma, American Electric Power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of ray profile modeling on resolution recovery in clinical CT

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to be able to focus on comparing spatial resolution. The authors use two different simulation settings. Both are based on the geometry of a typical clinical CT system (0.7 mm detector element size at isocenter, 1024 projections per rotation). Setting one has an exaggerated source width of 5.0 mm. Setting two has a realistically small source width of 0.5 mm. The authors also investigate the transition from setting one to two. To quantify image quality, the authors analyze line profiles through the resolution patterns to define a contrast factor (CF) for contrast-resolution plots, and the authors compare the normalized cross-correlation (NCC) with respect to the ground truth of the circular resolution patterns. To independently analyze whether RM is of advantage, the authors implemented several iterative reconstruction algorithms: The statistical iterative reconstruction algorithm OSC, the ordered subsets simultaneous algebraic reconstruction technique (OSSART) and another statistical iterative reconstruction algorithm, denoted with ordered subsets maximum likelihood (OSML) algorithm. All algorithms were implemented both without RM (denoted as OSC, OSSART, and OSML) and with RM (denoted as OSC-RM, OSSART-RM, and OSML-RM). Results: For the unrealistic case of a 5.0 mm focal spot the CF can be improved by a factor of two due to RM: the 4.2 LP/cm bar pattern, which is the first bar pattern that cannot be resolved without RM, can be easily resolved with RM. For the realistic case of a 0.5 mm focus, all results show approximately the same CF. The NCC shows no significant dependency on RM when the source width is smaller than 2.0 mm (as in clinical CT). From 2.0 mm to 5.0 mm focal spot size increasing improvements can be observed with RM. Conclusions: Geometric RM in iterative reconstruction helps improving spatial resolution, if the ray cross-section is significantly larger than the ray sampling distance. In clinical CT, however, the ray is not much thicker than the distance between neighboring ray centers, as the focal spot size is small and detector crosstalk is negligible, due to reflective coatings between detector elements. Therefore,RM appears not to be necessary in clinical CT to achieve resolution recovery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Establishing an IEZ at the K-25 Site With Realism [Slides]

The requirement from ANSI/ANS-8.3 states: (1) a criticality alarm system meeting the requirements of this standard shall be installed in areas where personnel would be subject to an excessive radiation dose; and (2) excessive dose = any dose to personnel corresponding to an absorbed dose from neutrons and gamma rays equal to or greater than 0.12 Gy (12 rad) in free air. The requirement was misconstrued to imply that the Immediate Evaluation Zone (IEZ) had to cover out to 12 Rad of dose. This misinterpretation prompted the following official clarification: The standard does not attempt to define the area that is to be evacuated, which is considered a management responsibility and outside the scope of this Standard. What we wanted was an IEZ that: (1) depended on the facility characteristics and hazards; (2) departed from the one 'Size' fits all mentality; (3) balanced the risk of a criticality with the risk of evacuating; and (4) was consistent with the emergency planning process. What they have is a facility that is a mile long; a facility that was falling down around them; a facility where workers are routinely in fall protection; and a facility where high noise is the normal condition. They ended up matching ANS-8.23 with their EPHA and DSA and eliminated 12 Rad as the criterion; integrated Emergency Planning into the process; established evacuation zones using DSA consequence levels; and introduced time dependence into the evacuation process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulation of an x-ray volume imaging cone beam CT unit

In this work the authors characterized the radiation field produced by a kilovolt cone beam computed tomography (CBCT) unit integrated in the Elekta Synergy linear accelerator. The x-ray volume imaging (XVI) radiation unit was modeled in detail using the BEAMNRC Monte Carlo (MC) code system. The simulations of eight collimator cassettes and the neutral filter F0 were successfully carried out. MC calculations from the EGSNRC code DOSXYZNRC were benchmarked against measurements in water. A large set of depth dose and lateral profiles was acquired with the ionization chamber in water, with the x-ray tube in a stationary position, and with the beam energy set to 120 kV. Measurements for all the available collimator cassettes were compared with calculations, showing very good agreement (<2% in most cases). Furthermore, half value layer measurements were carried out and used to validate the MC model of the XVI unit. In this case dose calculations were performed with the EGSNRC code cavity and these showed excellent agreement. In this manuscript the authors also report on the optimization work of the relevant parameters that influenced the development of the MC model. The dosimetric part of this work was very useful in characterizing the XVI radiation output for the energy of interest. The detailed simulation part of the work is the first step toward an accurate MC based assessment of the dose delivered to patients during routine CBCT scans for image and dose guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar Particle Induced Upsets in the TDRS-1 Attitude Control System RAM During the October 1989 Solar Particle Events

The three large solar particle events, beginning on October 19, 1989 and lasting approximately six days, were characterized by high fluences of solar protons and heavy ions at 1 AU. During these events, an abnormally large number of upsets (243) were observed in the random access memory of the attitude control system (ACS) control processing electronics (CPE) on-board the geosynchronous TDRS-1 (Telemetry and Data Relay Satellite). The RAM unit affected was composed of eight Fairchild 93L422 memory chips. The Galileo spacecraft, launched on October 18, 1989 (one day prior to the solar particle events) observed the fluxes of heavy ions experienced by TDRS-1. Two solid-state detector telescopes on-board Galileo, designed to measure heavy ion species and energy, were turned on during time periods within each of the three separate events. The heavy ion data have been modeled and the time history of the events reconstructed to estimate heavy ion fluences. These fluences were converted to effective LET spectra after transport through the estimated shielding distribution around the TDRS-1 ACS system. The number of single event upsets (SEU) expected was calculated by integrating the measured cross section for the Fairchild 93L422 memory chip with average effective LET spectrum. The expected number of heavy ion induced SEU's calculated was 176. GOES-7 proton data, observed during the solar particle events, were used to estimate the number of proton-induced SEU's by integrating the proton fluence spectrum incident on the memory chips, with the two-parameter Bendel cross section for proton SEU'S. The proton fluence spectrum at the device level was gotten by transporting the protons through the estimated shielding distribution. The number of calculated proton-induced SEU's was 72, yielding a total of 248 predicted SEU'S, very dose to the 243 observed SEU'S. These calculations uniquely demonstrate the roles that solar heavy ions and protons played in the production of SEU's during the October 1989 solar particle events.

Croley, D. R.↗

Galactic Cosmic Radiation (GCR) Measurements Made by M-42 Active Dosimeters on NASA Balloon Flights (New Mexico & Antarctica) Resemble Levels Expected at Mars

Mimicking galactic cosmic radiation (GCR) is difficult with ground-based simulations and experimental results are limited by facility constraints. In the past year, we flew two consecutive missions on large NASA scientific balloons (to ~ 38 km altitude) launched from New Mexico (6.5-hr flight) and Antarctica (32-d flight) and will report GCR doses comparable to levels expected at the equatorial Mars surface. Measurements were made in collaboration with the DLR and utilizing the M-42 active radiation dosimeter developed for use on Artemis 1. The M-42 instrument stores data in flash memory, records charged particles over a substantial part of the trapped proton and the GCR LET spectrum, and can be easily integrated into payloads due to its compact size (182 x 44 x 22 mm; 237 g) and internal battery (up to 6 weeks of operation). Our presentation will provide an overview of the two recent balloon missions (payload description; flight profiles), and summarize the radiation data collected in the middle stratosphere, highlighting how robust, real GCR exposures can be achieved without needing to fly orbital or deep space experiments.

radiation↗

Nuclear Thermal Propulsion (NTP) Fission Product and Source Term Analysis

Nuclear thermal propulsion (NTP) is an in-space propulsion technology that uses a nuclear reactor to directly heat a propellant to provide high thrust, at higher efficiencies than achievable with conventional chemical propulsion systems. Due to the ability of NTP rockets to efficiently provide high thrust, this technology has been proposed for long duration space missions such as crewed missions to Mars and beyond. A primary hurdle for NTP technology development is the demonstration of an integrated reactor engine system to verify its functionality and performance. This primarily requires the manufacture and testing of candidate reactor and engine technologies to demonstrate the proposed design enables desired performance and exhibits acceptable response under all known operation modes. A major component in this testing is fission product accumulation, since after operation radioactive isotopes can be produced and pose radiological dose concerns. This paper explains the background behind fission product analysis and the methodology used to evaluate current reactor designs and identify the amount of fission products present and their radiological impact. Results of multiple thrust level engines at different time periods are discussed and highlight the need for additional experimental testing to confirm fractional release levels of fission products out of the system. Benchmarking of models and future paths of analysis are also discussed.

Fission↗

Nuclear Thermal Propulsion (NTP) Fission Product and Source Term Analysis

Nuclear thermal propulsion (NTP) is an in-space propulsion technology that uses a nuclear reactor to directly heat a propellant to provide high thrust, at higher efficiencies than achievable with conventional chemical propulsion systems. Due to the ability of NTP rockets to efficiently provide high thrust, this technology has been proposed for long duration space missions such as crewed missions to Mars and beyond. A primary hurdle for NTP technology development is the demonstration of an integrated reactor engine system to verify its functionality and performance. This primarily requires the manufacture and testing of candidate reactor and engine technologies to demonstrate the proposed design enables desired performance and exhibits acceptable response under all known operation modes. A major component in this testing is fission product accumulation, since after operation radioactive isotopes can be produced and pose radiological dose concerns. This paper explains the background behind fission product analysis and the methodology used to evaluate current reactor designs and identify the amount of fission products present and their radiological impact. Results of multiple thrust level engines at different time periods are discussed and highlight the need for additional experimental testing to confirm fractional release levels of fission products out of the system. Benchmarking of models and future paths of analysis are also discussed.

Nuclear Thermal Propulsion↗

PRELIMINARY TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE INTEGRATION OF A PROCESS UTILIZING LOW-ENERGY SOLVENTS FOR CARBON DIOXIDE CAPTURE ENABLED BY A COMBINATION OF ENZYMES AND ULTRASONICS WITH A SUBCRITICAL PC POWER PLANT

The results of the preliminary techno-economic assessment for integrating a process utilizing low-energy solvents for carbon dioxide (CO2) capture enabled by a combination of enzymes and ultrasonics with a subcritical pulverized coal (PC) power plant are presented. Four cases utilizing the enzyme-activated solvent are compared using different methodologies of regeneration against the DOE/NETL reference MEA case. The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as enzyme make-up rate and the capability of the ultrasonic regeneration process. The net efficiency of the integrated PC power plant with CO2 capture changes from 24.9% with the reference Case 10 plant to between 24.34% and 29.97% for the vacuum regeneration options considered, and to between 26.63% and 31.41% for the ultrasonic regeneration options. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variable being the initial estimation of enzyme dosing rate. The LCOE ($/MWh) values range from 112.92 to 125.23 for the vacuum regeneration options and from 108.9 to 117.50 for the ultrasonic regeneration cases considered in comparison to 119.6 for the reference Case 10. A sensitivity analysis of the effect of critical parameters on the LCOE was also performed. The results from the preliminary techno-economic assessment show that the proposed technology can be investigated further with a view to being a viable alternative to conventional CO2 scrubbing technologies.

Swaminathan, Saravanan↗

Custom Equipment Development for Processing of Surplus Plutonium

The Strategic Laboratory Assessment (SLA), a collaborative team of SRNL and ORNL personnel, has been established to advance the objectives of the Surplus Plutonium Disposition (SPD) Project, by identifying and developing technologies to accelerate disposition, reduce life cycle costs, minimize worker radiation exposure, improve worker safety, and minimize Surplus Plutonium Disposition Program risks. [1] The SLA team has identified can cutting and plutonium (Pu) oxide size reduction as two glovebox processes where technology enhancements would be valuable. The DOE&#x2;STD-3013 package currently in use for Pu downblending requires cutting two nested cans before the inner convenience can that holds the Pu oxide may be accessed for further processing. A rotary tubing-style cutter is used for opening the 3013 packages within the glovebox. Collet changeouts are required between cutting of the outer and inner cans. The SLA team is currently developing and testing an adjustable-clamp can cutter design that eliminates collet changeouts and allows cutting of the outer and inner can at the same time, resulting in significant reduction of radiological dose and process time, as well as improved ergonomics. To meet the Pu oxide particle size requirement, size reduction of Pu oxide agglomerations must be performed within the process gloveboxes. The SLA team has identified jaw crushing technology as an alternative to the currently employed rotary mill. Jaw crusher advantages include reduced dust within the glovebox, increased batch sizes, and easier integration with other glovebox processes due to the flow-through nature of jaw crushing. Commercially manufactured jaw crushers are either too large and/or too heavy for implementation in the SPD gloveboxes, so the SLA team is developing and testing a custom jaw crusher to meet the needs of the SPD Project.

Krementz, Daniel [Savannah River National Laborato↗

A Comparison of GoldSim, RESRAD-Onsite, and NORMALYSA Modeling Tools at Radioactive Waste Sites - 19480

Radioactive waste disposal and associated decision making is a challenging problem around the world. A strong performance assessment model plays a crucial role in making good management and remediation decisions and in optimizing the performance of a site. The International Atomic Energy Agency (IAEA) MODARIA II Working Group 1 (WG1) is comparing the performance of various modeling platforms used at Naturally Occurring Radioactive Material (NORM) and legacy waste sites to support risk-informed decision making. Neptune and Company, Inc. (Neptune) has developed probabilistic performance assessment models using the GoldSim system modeling software at a variety of radioactive waste sites. This paper presents a comparison between GoldSim and two other tools used to evaluate radiation exposure and their associated risks: the NORM And Legacy Site Assessment (NORMALYSA) tool used to assess risk at the Zapadnoe mill tailings site, and the residual radioactivity (RESRAD-Onsite) computer program used to calculate Authorized Limits at the Los Alamos National Laboratory (LANL). The International Atomic Energy Agency (IAEA) supported development of NORMALYSA based off of Ecolego 6.0, in which the user connects several universal modules, representing various environmental transport and exposure pathways, and enters in site-specific data. Further work with NORMALYSA has continued under the MODARIA II WG 1. A radionuclide transport and dose calculation model of the Zapadnoe uranium mill tailings site at the Pridneprovsky Chemical Plant in the Ukraine has been configured by MODARIA II WG1 to test the capabilities of NORMALYSA. Under this test case, contaminant transport and effective dose calculations were performed for two exposure scenarios. The onsite worker is exposed via external ground irradiation and radon and radioactive dust inhalation. The offsite resident defines a residence established 300 years after institutional control has ended, 800 meters downstream from the site with exposure pathways including: ingestion of garden vegetables irrigated by contaminated ground water, ingestion of fish from the Konoplyanka River and agricultural activities in the contaminated garden. GoldSim modeling software is a dynamic probabilistic modeling platform that evaluates uncertainty in a robust and transparent manner. Although GoldSim provides contaminant and radionuclide transport modules to facilitate integrated modeling of radionuclide migration in the environment, these features are not embedded in an existing modeling framework, except as created by the user. Neptune developed a GoldSim model for the two exposure scenarios of the Zapadnoe test case. Neptune's Generic PA Model was used as a starting point for the Zapadnoe site. Input parameters for the GoldSim model include site-specific parameters from the MODARIA Working Group as well as parameters from the Generic PA Model and other PA models created by Neptune. For the other comparison, Version 7.0 of RESRAD-Onsite, developed by Argonne National Laboratory for the U.S. Department of Energy (DOE), was used to calculate Authorized Limits for LANL. Authorized Limits are concentrations of radionuclides in soil that support the evaluation process to clear land for release under different uses. The RESRAD-Onsite computer code was used to calculate Authorized Limits because this program was specifically designed to derive radionuclide soil guidelines corresponding to a specific dose criterion. The scope of the RESRAD dose or risk evaluation is constrained to the transport and exposure pathways that have been included in the computer code. To assist in illustrating the capability of GoldSim modeling software, a GoldSim model was created to replicate the calculation of LANL's Authorized Limits for soil. The main exposure pathways in this model are inhalation of dust and gas, plant ingestion, soil ingestion, and external ground irradiation. All of the processes and outputs of RESRAD-Onsite and NORMALYSA can be created in a GoldSim model, but the value of GoldSim lies in its flexibility for application to any of a wide variety of environmental modeling problems. GoldSim allows development of site-specific inventory, transport mechanisms and risk assessment scenarios. If all potentially complete release, transport, and exposure pathways are addressed in an existing dose and risk assessment computer code, and if the code's capabilities fulfill the project modeling objectives, then expending resources to create a GoldSim model may not be necessary. Site optimization and good decision making about site management are often best when supported with the flexibility of GoldSim as a modeling tool. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Target tracking using DMLC for volumetric modulated arc therapy: A simulation study

Purpose: Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. Methods: The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. Results: The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. Conclusions: A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is the Martian Water Table Hidden from Radar View?

Mars may possess a global sub-surface groundwater table as an integral part of its current hydrological system, However, the Mars Advanced Radar for Subsurface and Ionospheric Sounding (MARSIS) onboard the 'Mars Express (MEx) spacecraft has yet to make a definitive detection of such a body of liquid water. In this work, we quantify. the conditions that would allow a detection of a deep aquifer and demonstrate that the lack of radar detection doses not uniquely role out the presence of such a body. Specifically, if the overlying crustal material has a conductivity above approximately 10(exp -5) S/m (equivalent to a loss tangent of 0.008), a radar echo frown an aquifer could be sufficiently attenuated by the intetvening medium to prevent its detection by MARSIS. As such, the lack of direct detection by MARSIS -- a "null result" does not rule out the possibility of the water table's existence.

Farrell, W. M.↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes in situ polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

61 RADIATION PROTECTION AND DOSIMETRY↗

HBU R and D Cask Transportation Options - 20436

The TN-32B HBU Demonstration Cask was successfully loaded in November 2017 with 32 high burnup (HBU) fuel assemblies at Dominion's North Anna Nuclear Plant and is collecting thermal data as intended. The first two phases of this very successful project sponsored by DOE and EPRI was designed to collect thermal data of HBU fuel to support extended storage. The next phase of the project requires the cask be licensed for transportation so the cask can be relocated to a site (to be determined by DOE) to facilitate long term monitoring and additional research on the fuel. This is a unique challenge given the constraints that exist for this particular bolted metal cask. The TN-32B cask is a 234,288 lb. (storage configuration) dry storage system that was selected for this project and it was modified to provide thermal data and the ability to collect gas samples after loading. Several major issues must be addressed to obtain the transport license including protecting the seven lid penetrations that were made to allow for the insertion of the thermocouples into the selected fuel assemblies after the cask was loaded. In order to protect the integrity of the research, the payload must remain as is. Therefore, the cask system must be placed into the transportation configuration without rewetting the fuel, replacing the lid and without removing the thermocouple instrumentation that is currently installed. A critical portion of the design and engineering that was performed in the first two phases of the project was to ensure that future transportation of the cask was integrated into the approach. Efforts were made to accommodate requirements such as containment boundary leakage testing, installation of impact limiter brackets and lid bolts suitable for transportation. Due to the science requirements of the project, the fuel selected was intended to yield the highest payload temperatures permitted to provide the greatest value for the researchers. This resulted in higher than usual external dose rates and surface temperatures that warranted performing as much preparatory work prior to cask loading to ensure ALARA and personnel safety to the greatest extent practical rather than working on a loaded cask. In addition to the work performed prior to cask load, there are remaining challenges such as protecting the modified lid, design and fabrication of impact limiters that accommodate the modified cask lid and preserving the thermocouple connections for continued monitoring. The project team is currently performing the necessary calculations, engineering, and design to support the licensing as required by the US NRC. Pre-application meetings have been held to inform the regulator of the planned technical approach to ensure compliance with the applicable regulations. The current plan is to obtain the transportation C of C by the end of 2021. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗