Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IGNITION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Analysis of combustion acoustic phenomena in compression–ignition engines using large eddy simulation

As computational capabilities continue to grow, exploring the limits of computational fluid dynamics to capture complex and elusive phenomena, which are otherwise difficult to study by experimental techniques, is one of the main targets for the research community. This paper presents a detailed analysis of the physical processes that lead to combustion noise emissions in internal combustion engines. In particular, diesel combustion in a compression-ignition (CI) engine is studied in order to understand the singular behavior of the in-cylinder flow field responsible for the acoustic emissions. The main objective is, therefore, to improve the understanding of the phenomena involved in CI engine noise using large eddy simulations. Several visualization methods are employed to investigate the connection between combustion behavior and its effects on the pressure field. In addition, proper orthogonal decomposition is used to analyze the modal energy distribution among all the acoustic modes. The results show that the acoustic signature is fundamentally conditioned by the intensity of the premixed combustion rather than by the pressure oscillations generated by turbulent fluctuations in the flame surface established during the diffusion stage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence of restricted heat transport in National Ignition Facility Hohlraums

We present experimental evidence of restricted electron thermal conduction in the high-Z coronal plasma regions of laser-driven Hohlraums on the National Ignition Facility. Four separate measurements, three of which are direct observations of Hohlraum dynamics, corroborate this finding. (1) The velocity of the coronal plasma ablated and heated by the outer-cone laser beams is determined by time-dependent imaging of the gold plasma plume, or “bubble.” The velocities of the incoming plume (perpendicular to the Hohlraum axis) are consistent with high-fidelity 2D radiation-hydrodynamic simulations using flux-limited thermal electron conduction with a flux multiplier f = 0.03. Simulations using f = 0.15, which is very nearly classical Spitzer–Härm transport, predict plume velocities slower than measured. (2) Specific features in time-resolved images of the Hohlraum wall at an angle of 19° are also more consistent with f = 0.03 simulations compared to f = 0.15. (3) Spectroscopic tracers were added to the Hohlraum wall in the outer-beam bubble region. The ratios of hydrogen-like to helium-like line emission are sensitive to the electron temperature of the bubble. The hydrogen-like to helium-like ratios extracted from the time-integrated spectra of manganese and cobalt tracers from two observation angles are consistent with f = 0.03 and not with f = 0.15. (4) The time of peak capsule emission, or “bang time,” an integrated measurement, is also more consistent with f = 0.03 than with f = 0.15. Overall, while these findings do not identify the causes of restricted thermal conduction in Hohlraums, they motivate future experiments to test specific hypotheses and focus on model development in the regions of the plasma exhibiting restricted transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the Marble experimental platform at the National Ignition Facility

The Marble experimental platform at the National Ignition Facility (NIF) was developed to quantify the influence of heterogeneous mix on fusion burn. The platform utilizes a plastic capsule filled with a deuterated plastic foam of controlled coarseness, with tritium gas filling the voids in the foam. The capsule implosion is driven with x rays generated in an NIF Hohlraum in which the time-dependent symmetry of the implosion can be controlled via dynamic beam phasing. Importantly, the Hohlraum drive conditions can be understood via integrated 2D radiation-hydrodynamic simulations, and capsule implosions can be reliably calculated. After several years of development and experimentation, the NIF Marble platform has become successful and has produced important experimental results. Here, the experimental results, which will be presented in a future publication by the LANL Marble team, provide the first definitive examination of the influence of heterogeneous mix on thermonuclear burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated performance of large HDC-capsule implosions on the National Ignition Facility

In this paper, we report on eight, indirect-drive, deuterium–tritium-layered, inertial-confinement-fusion experiments at the National Ignition Facility to determine the largest capsule that can be driven symmetrically without relying on cross-beam energy transfer or advanced Hohlraum designs. Targets with inner radii of up to 1050 μm exhibited controllable P 2 symmetry, while larger capsules suffered from diminished equatorial drive. Reducing the Hohlraum gas-fill-density from 0.45 mg/cm 3 to 0.3 mg/cm 3 did not result in a favorable shift of P 2 amplitude as observed in preceding tuning experiments. Reducing the laser-entrance-hole diameter from 4 mm to 3.64 mm decreased polar radiation losses as expected, resulting in an oblate symmetry. The experiments exhibited the expected performance benefit from increased experimental scale, with yields at a fixed implosion velocity roughly following the predicted 1D dependence. With an inner radius of 1050 μm and a case-to-capsule-ratio of 3.0, experiment N181104 is the lowest implosion-velocity experiment to exceed a total neutron yield of 10 16 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Saturn-ring proton backlighters for the National Ignition Facility

Proton radiography is a well-established technique for measuring electromagnetic fields in high-energy-density plasmas. Fusion reactions producing monoenergetic particles, such as D 3 He, are commonly used as a source, produced by a capsule implosion. Using smaller capsules for radiography applications is advantageous as the source size decreases, but on the National Ignition Facility (NIF), this can introduce complications from increasing blow-by light, since the phase plate focal spot size is much larger than the capsules. In this article, we report a demonstration of backlighter targets where a “Saturn” ring is placed around the capsule to block this light. The nuclear performance of the backlighters is unperturbed by the addition of a ring. We also test a ring with an equatorial cutout, which severely affects the proton emission and is not viable for radiography applications. These results demonstrate the general viability of Saturn ring backlighter targets for use on the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

Optimal choice of multiple line-of-sight measurements determining plasma hotspot velocity at the National Ignition Facility

The measurement of plasma hotspot velocity provides an important diagnostic of implosion performance for inertial confinement fusion experiments at the National Ignition Facility. The shift of the fusion product neutron mean kinetic energy as measured along multiple line-of-sight time-of-flight spectrometers provides velocity vector components from which the hotspot velocity is inferred. Multiple measurements improve the hotspot velocity inference; however, practical considerations of available space, operational overhead, and instrumentation costs limit the number of possible line-of-sight measurements. Here, we propose a solution to this classical “experiment design” problem that optimizes the precision of the velocity inference for a limited number of measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

The five line-of-sight neutron time-of-flight (nToF) suite on the National Ignition Facility (NIF)

Measurement of the neutron spectrum from inertial confinement fusion implosions is one of the primary diagnostics of implosion performance. Analysis of the spectrum gives access to quantities such as neutron yield, hot-spot velocity, apparent ion temperature, and compressed fuel ρr through measurement of the down-scatter ratio. On the National Ignition Facility, the neutron time-of-flight suite has been upgraded to include five independent, collimated lines of sight, each comprising a high dynamic range bibenzyl/diphenylacetylene-stilbene scintillator [R. Hatarik et al., Plasma Fusion Res. 9, 4404104 (2014)] and high-speed fused silica Cherenkov detectors [A. S. Moore et al., Rev. Sci. Instrum. 89, 10I120 (2018)].

Moore, A. S. (ORCID:0000000221258882)↗

Top-level physics requirements and simulated performance of the MRSt on the National Ignition Facility

The time-resolving Magnetic Recoil Spectrometer (MRSt) for the National Ignition Facility (NIF) has been identified by the US National Diagnostic Working Group as one of the transformational diagnostics that will reshape the way inertial confinement fusion (ICF) implosions are diagnosed. The MRSt will measure the time-resolved neutron spectrum of an implosion, from which the time-resolved ion temperature, areal density, and yield will be inferred. Top-level physics requirements for the MRSt were determined based on simulations of numerous ICF implosions with varying degrees of alpha heating, P2 asymmetry, and mix. Synthetic MRSt data were subsequently generated for different configurations using Monte–Carlo methods to determine its performance in relation to the requirements. The system was found to meet most requirements at current neutron yields at the NIF. This work was supported by the DOE and LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrade of the gated laser entrance hole imager G-LEH-2 on the National Ignition Facility

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single “Furi” hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual “Icarus” sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium–triterium experiments, enable significantly greater return of data per experiment.

47 OTHER INSTRUMENTATION↗

Sample test array and recovery (STAR) platform at the National Ignition Facility

We have developed the Sample Test Array and Recovery (STAR) platform for the National Ignition Facility (NIF) for studying the thermal and hydrodynamic responses of materials in extreme environments. The STAR platform expands the range of obtainable fluences and quadruples the rate that materials experiments can be conducted at the NIF. Example configurations are demonstrated for fluences spanning 0.56–34 J/cm 2 with environmental isolation for post-shot material recovery and inspection and up to 1740 J/cm 2 without isolation, with surface heating rates of up to 2 × 10 14 K/s. Lastly, an example experiment involving thermally driven shock and spallation of aluminum alloy 7075 is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

Three dimensional low-mode areal-density non-uniformities in indirect-drive implosions at the National Ignition Facility

To achieve hotspot ignition, an inertial confinement fusion implosion must achieve high hotspot pressure that is inertially confined by a dense shell of DT fuel. This requires a symmetric implosion having high in-flight shell velocity and high areal density at stagnation. The size of the driver and scale of the capsule required can be minimized by maintaining a high efficiency of energy coupling from the imploding shell to the hotspot. Significant 3D low mode asymmetries, however, are commonly observed in indirect-drive implosions and reduce the coupling of shell kinetic energy to the hotspot. To better quantify the magnitudes and impacts of shell density asymmetries, we have developed new analysis techniques and analytic models [Hurricane et al., Phys. Plasmas 27(6), 062704 (2020)]. To build confidence in the underlying data, we have also developed an analytic neutron transport model to cross-compare two independent measurements of asymmetry, which shows excellent agreement across shots for mode-1 (ℓ = 1). This work also demonstrates that asymmetry can introduce potential sampling bias into down-scattered ratio measurements causing the solid-angle-average and uncertainty-weighted-average down-scattered ratios to differ significantly. Diagnosing asymmetries beyond mode-1 (ℓ > 1) presents significant challenges. Using new diagnostic instruments and analysis techniques, however, evidence of significant Legendre mode P2 (ℓ = 2, m = 0) and additional 3D asymmetries (ℓ > 1, m ≠ 0) are beginning to emerge from the high precision activation diagnostic data (real-time nuclear activation detectors) and down-scattered neutron imaging data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long duration x-ray source development for x-ray diffraction at the National Ignition Facility

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

Werellapatha, K. (ORCID:0000000293154054)↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗