Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Distribution and pharmacokinetics of methamphetamine in the human body: clinical implications

Methamphetamine is one of the most toxic of the drugs of abuse, which may reflect its distribution and accumulation in the body. However no studies have measured methamphetamine's organ distribution in the human body. Positron Emission Tomography (PET) was used in conjunction with [{sup 11}C]d-methamphetamine to measure its whole-body distribution and bioavailability as assessed by peak uptake (% Dose/cc), rate of clearance (time to reach 50% peak-clearance) and accumulation (area under the curve) in healthy participants (9 Caucasians and 10 African Americans). Methamphetamine distributed through most organs. Highest uptake (whole organ) occurred in lungs (22% Dose; weight {approx}1246 g), liver (23%; weight {approx}1677 g) and intermediate in brain (10%; weight {approx}1600 g). Kidneys also showed high uptake (per/cc basis) (7%; weight 305 g). Methamphetamine's clearance was fastest in heart and lungs (7-16 minutes), slowest in brain, liver and stomach (>75 minutes), and intermediate in kidneys, spleen and pancreas (22-50 minutes). Lung accumulation of [{sup 11}C]d-methamphetamine was 30% higher for African Americans than Caucasians (p < 0.05) but did not differ in other organs. The high accumulation of methamphetamine, a potent stimulant drug, in most body organs is likely to contribute to the medical complications associated with methamphetamine abuse. In particular, we speculate that methamphetamine's high pulmonary uptake could render this organ vulnerable to infections (tuberculosis) and pathology (pulmonary hypertension). Our preliminary findings of a higher lung accumulation of methamphetamine in African Americans than Caucasians merits further investigation and questions whether it could contribute to the infrequent use of methamphetamine among African Americans.

59 BASIC BIOLOGICAL SCIENCES↗

Inhibition of the spider heartbeat by gravity and vibration

The rate and vigor of the spider heartbeat is controlled by an external pacemaker. A mechanical feature of the spider cardio-vascular system is the production of high serum pressure in the prosoma and the legs. This appears to be the source for leg extension. The lyriform organ on the patella of the leg is sensitive to vibratory and kinesthetic stimuli. This sensitivity depends upon the degree of leg extension. Thus the activity of the heart and the response characteristics of the sense receptor are related. The effect of a supra-threshold vibratory or gravitational stimulus is to produce an inhibition and a tachycardia of the spider heartbeat.

Finck, A.↗

Proton Therapy - Accelerating Protons to Save Lives

In 1946, physicist Robert Wilson first suggested that protons could be used as a form of radiation therapy in the treatment of cancer because of the sharp drop-off that occurs on the distal edge of the radiation dose. Research soon confirmed that high-energy protons were particularly suitable for treating tumors near critical structures, such as the heart and spinal column. The precision with which protons can be delivered means that more radiation can be deposited into the tumor while the surrounding healthy tissue receives substantially less or, in some cases, no radiation. Since these times, particle accelerators have continuously been used in cancer therapy and today new facilities specifically designed for proton therapy are being built in many countries. Proton therapy has been hailed as a revolutionary cancer treatment, with higher cure rates and fewer side effects than traditional X-ray photon radiation therapy. Proton therapy is the modality of choice for treating certain small tumors of the eye, head or neck. Because it exposes less of the tissue surrounding a tumor to the dosage, proton therapy lowers the risk of secondary cancers later in life - especially important for young children. To date, over 80,000 patients worldwide have been treated with protons. Currently, there are nine proton radiation therapy facilities operating in the United States, one at the Hampton University Proton Therapy Institute. An overview of the treatment technology and this new center will be presented.

59 BASIC BIOLOGICAL SCIENCES↗

PSR J2021+4026 in the Gamma Cygni Region: The First Variable Gamma-Ray Pulsar Seen by the Fermi LAT

Long-term monitoring of PSR J2021+4026 in the heart of the Cygnus region with the Fermi Large Area Telescope unveiled a sudden decrease in flux above 100 MeV over a timescale shorter than a week. The "jump" was near MJD 55850 (2011 October 16), with the flux decreasing from (8.33 plus or minus 0.08)×10(exp −10) erg cm(exp −2) s(exp −1) to (6.86 plus or minus 0.13)× 10 (exp −1)0 erg cm (exp −2) s(exp −1). Simultaneously, the frequency spindown rate increased from (7.8 plus or minus 0.1) × 10(exp −13) Hz s(exp −1) to (8.1 plus or minus 0.1) × 10(exp −1)3 Hz s(exp −1). Significant (greater than 5 sigma) changes in the pulse profile and marginal (less than 3 sigma) changes in the emission spectrum occurred at the same time. There is also evidence for a small, steady flux increase over the 3 yr preceding MJD 55850. This is the first observation at gamma-ray energies of mode changes and intermittent behavior, observed at radio wavelengths for other pulsars. We argue that the change in pulsed gamma-ray emission is due to a change in emission beaming and we speculate that it is precipitated by a shift in the magnetic field structure, leading to a change of either effective magnetic inclination or effective current.

pulsars: individual↗

Calculation of neutron-decay-proton trapping in the Jovian magnetosphere

Investigations on the possible proton fluxes resulting from cosmic ray albedo neutron decay (CRAND) are summarized. It is recalled that experimental data on the earth's belts are reasonably consistent with a CRAND source for most of the protons with energies 50 MeV in the heart of the inner belt. It is assumed that the CRAND and cosmic ray flux and spectrum for Jupiter are the same as for the Earth, with the significant difference that considerably higher energy particles are needed to reach the Jupiter atmosphere at the same magnetic latitude. The ratio of the CRAND source averaged over an L shell on Jupiter to that on Earth at L = 1.3 is derived from a geometrical calculation. The ratio of average loss rate on Jupiter to that for the Earth is also discussed. The flux around Jupiter is obtained by scaling according to the ratio of source to loss from the flux observed in the Earth's inner belt.

Thomas, J. R.↗

Use of ultrasound in altitude decompression modeling

A model that predicts the probability of developing decompression sickness (DCS) with various denitrogenation schedules is being developed by the Armstrong Laboratory, using human data from previous exposures. It was noted that refinements are needed to improve the accuracy and scope of the model. A commercially developed ultrasonic echo imaging system is being used in this model development. Using this technique, bubbles images from a subject at altitude can be seen in the gall bladder, hepatic veins, vena cava, and chambers of the heart. As judged by their motion and appearance in the vena cava, venous bubbles near the heart range in size from 30 to 300 M. The larger bubbles skim along the top, whereas the smaller ones appear as faint images near the bottom of the vessel. Images from growing bubbles in a model altitude chamber indicate that they grow rapidly, going from 20 to 100 M in 3 sec near 30,000 ft altitude. Information such as this is valuable in verifying those aspects of the DCS model dealing with bubble size, their growth rate, and their site of origin.

Olson, Robert M.↗

Gastrodin pretreatment alleviates myocardial ischemia/reperfusion injury through promoting autophagic flux

Gastrodin (GAS), a monomeric component exacted from the herb Gastrodia elata Bl, may have cardioprotective effects during injury caused by myocardial ischemia/reperfusion (I/R). For the significant role of autophagy in I/R process, we targeted to explore whether autophagy was contributing to the GAS-induced protective effects during I/R procedure. Male C57BL/6 mice were subjected to reversible left coronary artery ligation and cultured neonatal rat cardiomyocytes (NRCs) exposed to hypoxia were preconditioned with GAS prior to ischemia or hypoxia, following reperfusion for 2 h or re-oxygennation for 3 h respectively. Our results demonstrated that GAS pretreatment increased autophagy and reduced apoptosis during I/R, this effect was weakened by co-treatment with the autophagic flux inhibitor chloroquine (Cq). Compared to mice subjected solely to I/R, GAS-pretreated mice had a notably smaller heart infarct size and an elevation in cardiac function. In GAS-pretreated NRCs, WB data showed that autophagy was promoted (expression of p62 was inhibited and LC3II was increased). In addition, tandem fluorescent mRFP-GFP-LC3 assays illustrated that autophagosomes were degraded duo to an increase in autophagic flux. Co-administration of Cq blocked the autophagic flux. Furthermore, GAS pretreatment increased the mitochondrial membrane potential of NRCs with subjected to H/R and increased the cardiomyocyte survival rate. These protective effects were reversed with Cq. Besides, GAS-induced the enhaucement of autophagy may correlated with activating AMP-activated protein kinase (AMPK) phosphorylation and reduced Mammalian target of rapamycin (mTOR) phosphorylation, which was abrogated by Compound C (Com C, AMPK-specific inhibitor). Our results establish that GAS pretreatment attenuates myocardial I/R injury by increasing autophagic flux aimed at eliminating dysfunctional mitochondria, therefore protecting neighbouring mitochondria and cardiomyocytes.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-02: Incorporation of Contrast Medium Dynamics in Anthropomorphic Phantoms: The Advent of 5D XCAT Models

Purpose: To develop a unique method to incorporate the dynamics of contrast-medium propagation into the anthropomorphic phantom, to generate a five-dimensional (5D) patient model for multimodality imaging studies. Methods: A compartmental model of blood circulation network within the body was embodied into an extended cardiac-torso (4D-XCAT) patient model. To do so, a computational physiologic model of the human cardiovascular system was developed which includes a series of compartments representing heart, vessels, and organs. Patient-specific cardiac output and blood volume were used as inputs influenced by the weight, height, age, and gender of the patient's model. For a given injection protocol and given XCAT model, the contrast-medium transmission within the body was described by a series of mass balance differential equations, the solutions to which provided the contrast enhancement-time curves for each organ; thereby defining the tissue materials including the contrastmedium within the XCAT model. A library of time-dependent organ materials was then defined. Each organ in each voxelized 4D-XCAT phantom was assigned to a corresponding time-varying material to create the 5D-XCAT phantom in which the fifth dimension is blood/contrast-medium within the temporal domain. Results: The model effectively predicts the time-varying concentration behavior of various contrast-medium administration in each organ for different patient models as function of patient size (weight/height) and different injection protocol factors (injection rate and pattern, iodine concentration or volume). The contrast enhanced XCAT patient models was developed based on the concentration of iodine as a function of time after injection. Conclusion: Majority of medical imaging systems take advantage of contrast-medium administration in terms of better image quality, the effect of which was ignored in previous optimization studies. The study enables a comprehensive optimization of contrast administration both in terms of image quality and radiation dose, and can be used in different modalities such as CT, MRI, and ultrasound.

60 APPLIED LIFE SCIENCES↗

DFT and microkinetic comparison of Pt, Pd and Rh-catalyzed ammonia oxidation

Ammonia oxidation is the heart of the Ostwald process and is important in emissions control. Catalytic behaviors are a function of conditions and are observed to vary across the platinum group metals (PGMs) Pt, Pd, Rh. Here, we combine density functional theory computations and microkinetic modeling to rationalize these dependencies. We compute reactions over model (2 1 1) and (1 1 1) surfaces of PGMs. Binding energies are similar on Pd and Pt and generally greater on Rh, while activation energies vary across all metals. Rates on (2 1 1) surfaces are greater than (1 1 1) surfaces. Additionally, the stepped Pt is most active and stepped Rh most selective to N 2 at ammonia slip conditions, while at Ostwald process conditions, stepped Pd is most active and stepped Pt most selective to NO. Degree of rate and selectivity control analysis provides insights into the reactions limiting performance of PGMs. Both activation barriers and surface coverages influence rates and selectivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-136: Breath Hold Lung Phantom Study in Using CT Density Versus Relative Stopping Power Ratio for Proton Pencil Beam Scanning System

Purpose: To evaluate mass density effects of CT conversion table and its variation in current treatment planning system of spot scanning proton beam using an IROC proton lung phantom for this study. Methods: A proton lung phantom study was acquired to Imaging and Radiation Oncology Core Houston (IROC) Quality Assurance Center. Inside the lung phantom, GAF Chromic films and couples of thermal luminescent dosimeter (TLD) capsules embedded in specified PTV and adjacent structures to monitor delivered dosage and 3D dose distribution profiles. Various material such as cork (Lung), blue water (heart), Techron HPV (ribs) and organic material of balsa wood and cork as dosimetry inserts within phantom of solid water (soft tissue). Relative stopping power (RLSP) values were provided. Our treatment planning system (TPS) doesn’t require SP instead relative density was converted relative to water. However lung phantom was irradiated by planning with density override and the results were compared with IROC measurements. The second attempt was conducted without density override and compared with IROC’s. Results: The higher passing rate of imaging and measurement results of the lung phantom irradiation met the criteria by IROC without density override. The film at coronal plane was found to be shift due to inclined cylinder insertion. The converted CT density worked as expected to correlate relative stopping power. Conclusion: The proton lung phantom provided by IROC is a useful tool to qualify our commissioned proton pencil beam delivery with TPS within reliable confidence. The relative mass stopping power ratios of materials were converted from the relative physical density relative to water and the results were satisfied.

60 APPLIED LIFE SCIENCES↗

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗

Continuous Arc Rotation of the Couch Therapy for the Delivery of Accelerated Partial Breast Irradiation: A Treatment Planning Analysis

Purpose: We present a novel form of arc therapy: continuous arc rotation of the couch (C-ARC) and compare its dosimetry with three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) for accelerated partial breast irradiation (APBI). C-ARC, like VMAT, uses a modulated beam aperture and dose rate, but with the couch, not the gantry, rotating. Methods and Materials: Twelve patients previously treated with APBI using 3D-CRT were replanned with (1) C-ARC, (2) IMRT, and (3) VMAT. C-ARC plans were designed with one medial and one lateral arc through which the couch rotated while the gantry was held stationary at a tangent angle. Target dose coverage was normalized to the 3D-CRT plan. Comparative endpoints were dose to normal breast tissue, lungs, and heart and monitor units prescribed. Results: Compared with 3D-CRT, C-ARC, IMRT, and VMAT all significantly reduced the ipsilateral breast V50% by the same amount (mean, 7.8%). Only C-ARC and IMRT plans significantly reduced the contralateral breast maximum dose, the ipsilateral lung V5Gy, and the heart V5%. C-ARC used on average 40%, 30%, and 10% fewer monitor units compared with 3D-CRT, IMRT, and VMAT, respectively. Conclusions: C-ARC provides improved dosimetry and treatment efficiency, which should reduce the risks of toxicity and secondary malignancy. Its tangent geometry avoids irradiation of critical structures that is unavoidable using the en face geometry of VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repeatable and reproducible measurements of myocardial oxidative metabolism, blood flow and external efficiency using {sup 11}C-acetate PET

Background: Non-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of {sup 11}C-acetate positron emission tomography (PET) imaging of oxidative metabolism. Methods and results: Dynamic {sup 11}C-acetate PET scans were performed at baseline and followup (47 ± 22 days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients’ clinical data used FlowQuant{sup ®} to evaluate test–retest repeatability, as well as intra- and inter-observer reproducibility of {sup 11}C-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO{sub 2}), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland–Altman coefficient-of-repeatability (CR). Test–retest correlations and repeatability were better for MEE and WMI compared to MVO{sub 2}. All intra- and inter-observer correlations were excellent (ICC = 0.95-0.99) and the reproducibility values (CR = 3%-6%) were significantly lower than the test–retest repeatability values (22%-54%, P < 0.001). Repeatability was improved for all parameters using a newer PET–computed tomography (CT) scanner compared to older PET-only instrumentation. Conclusion: {sup 11}C-acetate PET measurements of WMI and MEE exhibited excellent test–retest repeatability and operator reproducibility. Newer PET–CT scanners may be preferred for longitudinal tracking of cardiac efficiency. [French] French Abstract: Contexte: Les examens non invasifs de la fonction myocardique aident à suivre la progression de l’insuffisance cardiaque. Dans ce travail, nous avons évalué la répétabilité et la reproductibilité de l’étude du métabolisme oxydatif du myocarde par imagerie tomographique à positrons avec l’acétate marqué au carbone 11. Méthodes et résultats: Une étude de base et un second examen TEP dynamique à l’ acétate marqué au carbone 11 ont été réalisés (47 ± 22 jours) chez 20 patients présentant une insuffisance cardiaque stable avec une fraction d’éjection réduite. Sans aucune connaissance des données cliniques et au moyen du programme FlowQuant®, deux observateurs ont évalué la répétabilité des TEPs de base et de leur suivi, la reproductibilité intra- et inter-observateur, l’absorption et la clearance du traceur, la mesure de la consommation d’oxygène du myocarde (MVO2), l’efficacité contractile du myocarde (MEE), l’index métabolique du travail myocardique (WMI) et le débit sanguin myocardique (MBF). La reproductibilité et la répétabilité ont été évaluées en utilisant la corrélation intra-classe (ICC) et le coefficient de répétabilité Altman (CR). Les corrélations entre les études de base et leur suivi et la répétabilité des données se sont avérées supérieures pour les paramètres MEE et WMI par rapport à MVO2. Toutes les corrélations intra- et inter-observateurs furent excellentes (ICC = 0,95-0,99). Les valeurs de reproductibilité (CR = 3-6%) furent significativement inférieures aux valeurs de répétabilité (22-54%, p <0.001). La répétabilité des paramètres mesurés s’est avérée supérieure avec un scanner TEP-TDM de nouvelle génération par rapport à l’utilisation de la TEP sans TDM Conclusion: Les mesures réalisées dans cette étude TEP 11C-acétate montre une excellent répétabilité et reproductibilité des paramètres WMI et WMI entre les examens de base et leur suivi effectués par des opérateurs différents. Les nouveaux scanners TEP-TDM devraient être préférés pour le suivi longitudinal de la fonction cardiaque. [Spanish] Spanish Abstract: Antecedentes: el abordaje no invasivo para investigar la eficiencia miocárdica puede ayudar en el seguimiento de la progresión de la insuficiencia cardíaca. Este estudio evalúa la repetibilidad y la reproducibilidad del estudio de metabolismo oxidativo con PET 11C-acetato. Métodos y resultados: Se realizaron estudios de PET 11C-acetato dinámicos al inicio y durante el seguimiento (47 ± 22 días de diferencia) en 20 pacientes con insuficiencia cardíaca estable y fracción de eyección reducida. Dos observadores cegados a los datos clínicos de los pacientes utilizaron FlowQuant® para evaluar la repetibilidad de la prueba-reprueba, así como la reproducibilidad intra e interobservador de la captación de radiotrazador 11C-acetato y sus tasas de eliminación, la medición del consumo miocárdico de oxígeno (MVO2), la eficiencia externa miocardica (EEM), el índice trabajo-metabólico (ITM) y flujo sanguíneo miocárdico (FSM). La reproducibilidad y la repetibilidad se evaluaron mediante la correlación intraclase (ICC) y el coeficiente de repetibilidad (CR) de Bland-Altman. Las correlaciones Prueba-Reprueba y la repetibilidad fueron mejores para la EEM y el ITM en comparación con el MVO2. Todas las correlaciones intra e interobservador fueron excelentes (ICC = 0.95-0.99) y los valores de reproducibilidad (CR = 3-6%) fueron significativamente menores que los valores de repetibilidad prueba-reprueba (22-54%, p <0.001). La repetibilidad fue mejor para todos los parámetros utilizando un equipo PET-TC más nuevo en comparación con un equipo PET sin CT. Conclusión: las mediciones del PET con 11C-acetato del ITM y EEM mostraron una excelente repetibilidad prueba-preprueba y reproducibilidad del operador. Los nuevos equipos PET-CT pueden ser elegidos para el seguimiento longitudinal de la eficiencia miocárdica. [Chinese] Chinese Abstract: 背景: 采用非侵入式方法来研究心肌代谢效率可以帮助追踪心力衰竭的过程。本研究评估利用碳-11 醋酸盐为 PET 显影剂行氧化代谢成像的可重复性和可再现性。 方法和结果: 纳入射血分数减低的 20 名稳定性心衰患者,对患者基线和 47±22 天随访都进行碳-11 醋酸盐 PET 扫描。为测量心肌耗氧量(MVO{sub 2}), 心肌外效率(MEE), 工作代谢指标(WMI)和心肌血流量(MBF), 两名观察者按照双盲的方法利用 FlowQuant®对碳-11 醋酸盐的摄取率和清空率进行了重复性测试以及不同观察者之间的可再现性测试。采用组内相关系数(ICC)和 Bland Altman 可重复性系数(CR)分别对可再现性和可重复性进行评估。MEE 和 WMI 的两次试验系数和可重复性优于MVO{sub 2}。所有观察者之间的相关系数都较好(ICC=0.95-0.99),可再现性系数的值(CR=3-6%)明显低于两次试验可重复性的值(22-54%, P<0.001)。相比于旧的只有 PET 的设备, 采用新型 PET-CT 扫描仪能够使所有参数的可再现性都有所提高。 结论: 碳-11醋酸盐 PET 显像测量 WMI 和 MEE 有很好的可重复性和可再现性。新的 PET-CT 扫描仪可能更适合于心脏代谢效率的长期追踪。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation With IMRT: New Technical Approach and Interim Analysis of Acute Toxicity in a Phase III Randomized Clinical Trial

Purpose: To evaluate with a randomized clinical trial the possibility of treating the index quadrant with external intensity-modulated radiotherapy (IMRT) in a selected group of patients with early-stage breast cancer and to analyze the acute toxicity. Methods and Materials: From September 2005, a randomized Phase III clinical trial has been conducted to compare conventional (tangential field) fractionated whole breast treatment (Arm A) with accelerated partial breast irradiation plus intensity-modulated radiotherapy (Arm B). For intensity-modulated radiotherapy, the clinical target volume was drawn with a uniform 1-cm margin around the surgical clips in three dimensions. The ipsilateral and contralateral breast, ipsilateral and contralateral lung, heart, and spinal cord were contoured as organs at risk. All the regions of interest were contoured according to the International Commission on Radiation Units and Measurements reports 50 and 62 recommendations. Results: In September 2008, 259 patients were randomized and treated. The mean clinical target volume in Arm B was 44 cm{sup 3} and the mean planning target volume was 123 cm{sup 3}. The mean value of the ratio between the planning target volume and the ipsilateral breast volume was 21%. The rate of Grade 1 and Grade 2 acute skin toxicity was 22% and 19% in Arm A (Radiation Therapy Oncology Group scale), respectively. The tolerance in Arm B was excellent with only 5% Grade 1 and 0.8% Grade 2 acute skin toxicity. The planning constraints were fully satisfied in most patients. In a very few cases, this was not possible because of very unfavorable anatomy. Quality assurance procedures were performed according to our internal quality assurance protocol, with excellent results. Conclusion: In the present preliminary analysis, we have demonstrated that accelerated partial breast irradiation is feasible, with very low acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LungMAP: The Molecular Atlas of Lung Development Program

The National Heart, Lung, and Blood Institute is funding an effort to create a molecular atlas of the developing lung (LungMAP) to serve as a research resource and public education tool. The lung is a complex organ with lengthy development time driven by interactive gene networks and dynamic cross talk among multiple cell types to control and coordinate lineage specification, cell proliferation, differentiation, migration, morphogenesis, and injury repair. A better understanding of the processes that regulate lung development, particularly alveologenesis, will have a significant impact on survival rates for premature infants born with incomplete lung development and will facilitate lung injury repair and regeneration in adults. A consortium of four research centers, a data coordinating center, and a human tissue repository provides high-quality molecular data of developing human and mouse lungs. LungMAP includes mouse and human data for cross correlation of developmental processes across species. LungMAP is generating foundational data and analysis, creating a web portal for presentation of results and public sharing of data sets, establishing a repository of young human lung tissues obtained through organ donor organizations, and developing a comprehensive lung ontology that incorporates the latest findings of the consortium. The LungMAP website (www.lungmap.net) currently contains more than 6,000 high-resolution lung images and transcriptomic, proteomic, and lipidomic human and mouse data and provides scientific information to stimulate interest in research careers for young audiences. This paper presents a brief description of research conducted by the consortium, database, and portal development and upcoming features that will enhance the LungMAP experience for a community of users.

60 APPLIED LIFE SCIENCES↗

Real-time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy

BACKGROUND: Infarct exclusion (IE) surgery, a technique of left ventricular (LV) reconstruction for dyskinetic or akinetic LV segments in patients with ischemic cardiomyopathy, requires accurate volume quantification to determine the impact of surgery due to complicated geometric changes. METHODS AND RESULTS: Thirty patients who underwent IE (mean age 61+/-8 years, 73% men) had epicardial real-time 3-dimensional echocardiographic (RT3DE) studies performed before and after IE. RT3DE follow-up was performed transthoracically 42+/-67 days after surgery in 22 patients. Repeated measures ANOVA was used to compare the values before and after IE surgery and at follow-up. Significant decreases in LV end-diastolic (EDVI) and end-systolic (ESVI) volume indices were apparent immediately after IE and in follow-up (EDVI 99+/-40, 67+/-26, and 71+/-31 mL/m(2), respectively; ESVI 72+/-37, 40+/-21, and 42+/-22 mL/m(2), respectively; P:<0.05). LV ejection fraction increased significantly and remained higher (0.29+/-0.11, 0.43+/-0.13, and 0.42+/-0.09, respectively, P:<0.05). Forward stroke volume in 16 patients with preoperative mitral regurgitation significantly improved after IE and in follow-up (22+/-12, 53+/-24, and 58+/-21 mL, respectively, P:<0.005). New York Heart Association functional class at an average 285+/-144 days of clinical follow-up significantly improved from 3.0+/-0.8 to 1.8+/-0.8 (P:<0.0001). Smaller end-diastolic and end-systolic volumes measured with RT3DE immediately after IE were closely related to improvement in New York Heart Association functional class at clinical follow-up (Spearman's rho=0.58 and 0.60, respectively). CONCLUSIONS: RT3DE can be used to quantitatively assess changes in LV volume and function after complicated LV reconstruction. Decreased LV volume and increased ejection fraction imply a reduction in LV wall stress after IE surgery and are predictive of symptomatic improvement.

Non-NASA Center↗

Substrate Channeling via a Transient Protein-Protein Complex: The case of D-Glyceraldehyde-3-Phosphate Dehydrogenase and L-Lactate Dehydrogenase

Molecular dynamics studies showed that LDH and GAPDH tetramers can form a complex which can breakdown when the enzymes are saturated with NADH molecules. The interaction sites are conserved between LDH isozymes from heart and muscle cells, and between GAPDH molecules from rabbit and yeast cells. Positive electric fields between the NAD(H) binding sites showed that NAD(H) channeling within LDH-GAPDH complex can be an extension of NAD(H) channeling between the adjacent subunits within LDH and GAPDH tetramers. Analytical ultracentrifugation and enzyme kinetics studies indicated that LDH and GAPDH molecules can form a transient channeling complex. The transient complex can support the channeled and the diffusive paths in parallel, the relative contribution from each path depends on the off-rates for (GAPDH-NADH)-LDH complex and GAPDH-NADH complex. Negative cooperativity in NADH binding to different subunits in GAPDH tetramers can provide allosteric regulation of NADH channeling from GAPDH to LDH.

INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMI↗

Prognostic value of left ventricular dyssynchrony evaluated by gated myocardial perfusion imaging in patients with chronic kidney disease and normal perfusion defect scores

Background: This study aimed to investigate whether indices of left ventricular (LV) dyssynchrony by gated myocardial perfusion SPECT (GMPS) could be useful to predict prognosis in chronic kidney disease (CKD) patients with normal perfusion defect scores. Methods: One hundred and sixty-seven CKD patients with normal perfusion defect scores on adenosine-stress {sup 201}Tl GMPS and no previous history of overt heart diseases were enrolled. Phase standard deviation (PSD) and bandwidth (BW) were automatically calculated from GMPS. The major adverse cardiac events (MACEs) for a mean of 560 days were defined as sudden cardiac death, fatal arrhythmias, and acute coronary syndrome requiring urgent coronary revascularization. Patients were divided into two groups according to the presence or absence of MACEs. Results: The MACEs occurred in 12 patients (7.1%). Patients who experienced MACEs showed significantly higher PSD and wider BW than those who did not. In the Kaplan-Meier event-free survival analysis, cardiac event rate was significantly higher in the high-PSD and wide-BW group (n = 81) than in the low-PSD and narrow-BW group (n = 71) (P = .002). The multivariate regression analysis revealed that the PSD was associated with MACEs (odds ratio 1.33, 95% confidence interval 1.05-1.69, P = .01). Conclusion: The LV dyssynchrony indices from GMPS may be novel prognostic predictors in CKD patients with normal perfusion defect scores.

62 RADIOLOGY AND NUCLEAR MEDICINE↗