Ocean color spectral variability studies using solar-induced chlorophyll fluorescence

It is suggested that chlorophyll-induced ocean color spectral variability can be studied using only a passive airborne spectroradiometer instrument, with solar-induced chlorophyll fluorescence used as the standard against which all correlations are performed. The intraspectral correlation (ISC) method is demonstrated with results obtained during an airborne mapping mission in the New York Bight. The curvature algorithm is applied to the solar-induced chlorophyll fluorescence at about 690 nm, and good agreement is found with results obtained using active-passive correlation spectroscopy. The ISC method has application to spectral variability and resulting chlorophyll concentration measurement in different environmental conditions and in different water types.

Hoge, Frank E.↗

Environmental effects on laser-induced fluorescence spectra of natural waters

Laser fluorosensing can be used to monitor dissolved organic carbon (DOC), but analysis of the data can be hindered by several environmental phenomena. These phenomena include attenuation of the laser beam and differential attenuation of the fluorescence by the water column, variability in the molecular weight composition of the DOC, and temperature, pH, and metal ion effects on DOC fluorescence. These factors are discussed in terms of their effect on laboratory and remote field data analysis. Experimental results are provided. Analysis of fluorosensor data of DOC may be improved by compensating for the environmental factors. An improved methodology is discussed, and a suggestion is made for indirect monitoring of pH and metal ion concentration.

Vodacek, Anthony↗

Measurements of temperature, density, pressure, and their fluctuations in supersonic turbulence using laser-induced fluorescence

A laser-induced fluorescence method has been developed that provides simultaneous measurements of temperature, density, and their fluctuations owing to turbulence in unheated compressible flows. Pressure and its fluctuations are also deduced using the equation of state. Fluorescence is induced in nitric oxide that has been seeded into a nitrogen flow in concentrations of 100 ppm. Measurements are obtained from each laser pulse, with a spatial resolution of 1 mm and a temporal resolution of 125 ns. The method was applied to a supersonic, turbulent, boundary-layer flow with a free-stream Mach number of 2. For stream conditions in the range from 150-300 K and 0.3-1 atm, temperature is measured with an uncertainty of approximately 1 percent rms, while density and pressure uncertainties are approximately 2 percent rms.

Gross, K. P.↗

Two-photon-excited fluorescence spectroscopy of atomic fluorine at 170 nm

Two-photon-excited fluorescence spectroscopy of atomic fluorine is reported. A doubled dye laser at 286-nm is Raman shifted in H2 to 170 nm (sixth anti-Stokes order) to excite ground-state 2P(0)J fluorine atoms to the 2D(0)J level. The fluorine atoms are detected by one of two methods: observing the fluorescence decay to the 2PJ level or observing F(+) production through the absorption of an additional photon by the excited atoms. Relative two-photon absorption cross sections to and the radiative lifetimes of the 2D(0)J states are measured.

Herring, G. C.↗

The fluorescence of cometary OH

A new solar spectral atlas, improved oscillator strengths, and additional transitions have been incorporated in calculations of the fluorescent equilibrium of the OH molecule in comets as a function of heliocentric distance and radial velocity. Comparisons of detailed, ultraviolet band profiles have been made with the observed, high-resolution spectra of eight comets. While a purely fluorescent equilibrium calculation is sufficient to reproduce the major variations seen in the band structure from one comet to another, some collisional quenching of the inversion of the X2II3/2 Lambda-doublet ground state is required to match the detailed features. The relative population inversion of the upper and lower levels of the ground state is also calculated as a function of both distance and velocity, with the results being consistent with 18 cm radio observations. Predictions of the infrared OH vibrational bands are made; the 1-0 band should be observable if a sufficiently high spectral resolution is employed.

Schleicher, David G.↗

CH(A, B-X) fluorescence from vacuum ultraviolet excitation of CH3

The fluorescence due to single-photon and two-photon excitation of CH3 produced by the reaction of CH4 with F or Cl in a flow tube is investigated experimentally. The excitation source is an excimer laser operating with pulse duration 6 nsec and repetition rate 20 Hz, and the fluorescence is observed using a 0.25-m spectrometer and a 1024-channel diode array; the results are presented graphically. Emission is detected at 157 nm (with approximate cross section 8 x 10 to the -19th sq cm) and 193 nm, but not at 248 nm. The applicability of these data to studies of hydrocarbon combustion, the methane oxidation cycle in the atmosphere, interstellar molecule formation, and diamond film fabrication is indicated.

Ye, Chao↗

Identification of new fluorescence processes in the UV spectra of cool stars from new energy levels of Fe II and Cr II

Two fluorescence processes operating in atmospheres of cool stars, symbiotic stars, and the Sun are presented. Two emission lines, at 1347.03 and 1360.17 A, are identified as fluorescence lines of Cr II and Fe II. The lines are due to transitions from highly excited levels, which are populated radiatively by the hydrogen Lyman alpha line due to accidental wavelength coincidences. Three energy levels, one in Cr II and two in Fe II, are reported.

Johansson, Sveneric↗

Three color laser fluorometer for studies of phytoplankton fluorescence

A three-color laser fluorometer has been developed for field work operations. Using two tunable dye lasers (excitation wavelengths at 440 nm and 530 nm), broadband wavelength optical filters were selected to obtain maximum fluorescence sensitivity at wavelengths greater than 675 nm (chlorophyll) and 575 + or - 15 nm (phycoerythrin). The laser fluorometer permits the measurement of phytoplankton pigments under static or flowing conditions and more closely resembles the time scales (ns) and energy levels (mW) of other laser-induced fluorescence instruments.

Phinney, David A.↗

Mystery spot in supernova 1987A - Reflection or fluorescence by an interstellar cloud?

This paper explores fluorescence and reflection models of the companion to SN 1987A obseved by speckle interferometry, recalling a 1901 precedent. The apparent small angular size of the companion is a severe constraint. A fluorescence model cannot reach the observed brightness unless the ultraviolet burst from the supernova contained as many as 2 x 10 to the 58th ionizing photons. This is about 25 times stronger than generous current models. Even then, the expected line ratios and widths do not fit the observations. The absence of narrow H-alpha and H-beta lines in the supernova spectrum, the ratio of fluxes of the companion in H-alpha and forbidden N II line filters, the invisibility of the companion at 4861 (H-beta), and its detection at 5330 fail to agree with theory. A dust-reflection model is more promising, and the color can be reddened by the evaporation of small grains, but the model still falls more than about 1 mag short in brightness. Furthermore, a dust reflection should have increased in relative brightness in May-June 1987, rather than disappearing as the mystery spot did. If all the observations are correct, neither model is likely to work.

Felten, James E.↗

Spectrophotometry near the atmospheric cutoff of the strongest Bowen resonance fluorescence lines of O III in two planetary nebulae

Spectrophotometric results are presented for the stronger, well-resolved Bowen O III resonance fluorescence emission lines in the planetary nebulae 7027 and NGC 7662 down to and including the intrinsically strong line at 3133 A. These data are combined with results from the IUE atlas of spectra and similar results for the longer wavelength lines by Likkel and Aller (1986) to give the first full coverage of the Bowen lines. Good agreement is found with fluorescence theory for the primary cascade lines, except for the Likkel and Aller results. The efficiency of conversion of the exciting He II Ly-alpha into O III lines is determined, and values comparable to other planetary nebulae are found.

O'Dell, C. R.↗

NH2 fluorescence efficiencies and the NH3 abundance in Comet Halley

If NH3 is the dominant source of the NH2 observed in comet spectra, then the NH3 abundance can in principle be accurately determined. Fluorescence efficiencies for the (0, v-prime/2/, O) to (0, 0, 0) progression of NH2 bands are calculated for NH2 bands likely to be observed in the 4500-8200-A region of comets. The results differ from previous determinations of the NH2 band fluorescence efficiencies by factors in the range 1.4-5.9, leading t6o significant changes in previously reported NH2 production rates in comets. A recalculation of the NH3/H2O abundance ratio in Comet Halley gives about (0.5 + or - 0.2) percent in better agreement with the Giotto ion-mass-spectrometer results of Allen et al (1987).

Tegler, Stephen↗

Injectant mole-fraction imaging in compressible mixing flows using planar laser-induced iodine fluorescence

A technique is described for imaging the injectant mole-fraction distribution in nonreacting compressible mixing flow fields. Planar fluorescence from iodine, seeded into air, is induced by a broadband argon-ion laser and collected using an intensified charge-injection-device array camera. The technique eliminates the thermodynamic dependence of the iodine fluorescence in the compressible flow field by taking the ratio of two images collected with identical thermodynamic flow conditions but different iodine seeding conditions.

Hartfield, Roy J., Jr.↗

Filter Enhances Fluorescent-Penetrant-Inspecting Borescope

Slip-on eyepiece for commercial ultraviolet-light borescope reduces both amount of short-wave ultraviolet light that reaches viewer's eye and apparent intensity of unwanted reflections of white light from surfaces undergoing inspection. Fits on stock eyepiece of borescope, which illuminates surface inspected with intense ultraviolet light. Surface, which is treated with fluorescent dye, emits bright-green visible light wherever dye penetrates - in cracks and voids. Eyepiece contains deep-yellow Wratten 15 (G) filter, which attenuates unwanted light strongly but passes yellow-green fluorescence so defects seen clearly.

Molina, Orlando G.↗

Non-destructive trace element microanalysis of as-received cometary nucleus samples using synchrotron x ray fluorescence

The Synchrotron X ray Fluorescence (SXRF) microprobe at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, will be an excellent instrument for non-destructive trace element analyses of cometary nucleus samples. Trace element analyses of as-received cometary nucleus material will also be possible with this technique. Bulk analysis of relatively volatile elements will be important in establishing comet formation conditions. However, as demonstrated for meteorites, microanalyses of individual phases in their petrographic context are crucial in defining the histories of particular components in unequilibrated specimens. Perhaps most informative in comparing cometary material with meteorites will be the halogens and trace metals. In-situ, high spatial resolution microanalyses will be essential in establishing host phases for these elements and identifying terrestrial (collection/processing) overprints. The present SXRF microprobe is a simple, yet powerful, instrument in which specimens are excited with filtered, continuum synchrotron radiation from a bending magnet on a 2.5 GeV electron storage ring. A refrigerated cell will be constructed to permit analyses at low temperatures. The cell will consist essentially of an air tight housing with a cold stage. Kapton windows will be used to allow the incident synchrotron beam to enter the cell and fluorescent x rays to exit it. The cell will be either under vacuum or continuous purge by ultrapure helium during analyses. Several other improvements of the NSLS microprobe will be made prior to the cometary nucleus sample return mission that will greatly enhance the sensitivity of the technique.

Sutton, S. R.↗

Fluorescence from photoexcitation of C2H5OH by vacuum ultraviolet radiation

The photoabsorption and fluorescence cross sections of C2H5OH have been measured in the 46-200 nm region. Fluorescence is dispersed to identify the emission systems, which are mainly OH(A-X), CH(A,B-X), and the H Balmer series. The photodissociation processes that produce the observed emissions are discussed.

Han, J. C.↗

A method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations due to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainty in the temperature and density measurements can be less than 2 and 3 percent, respectively, if the signal uncertainties are dominated by photon-statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Calculation of polarization and anisotropy of resonant and fluorescent scattering

Formulas are derived for the swift calculation of the angular intensity distribution and the degree of polarization associated with the resonant and fluorescent scattering of radiation by atoms which occurs in the rarefied upper atmospheres of planets during sunlit airglow phenomena. Attention is given to spectral lines with hyperfine structure, which are indicative of nuclear spin processes. The method employed involves summations over Zeeman components, allowing an evaluation of polarization through the addition of underlying simple resonant and fluorescent scattering channels.

Chamberlain, Joseph W.↗

The Fe XI-excited fluorescent cascade in Ne IV

A theoretical spectroscopic investigation of the fluorescent cascade to be expected in nitrogen-like Ne IV, when it is resonantly photoexcited by Fe XI in the solar atmosphere, symbiotic stars, or novae, is described. Primary and secondary cascade intensities are obtained as functions of photoexcitation rate, and expected absolute intensities in the solar atmosphere are derived on the basis of observed Fe XI and Ne EUV emission. Comparisons between the spatially resolved solar situation and spatially unresolved stellar cases of cataclysmic variables, in which these ions have been found to coexist, are made. An interesting possibility of periodic time-dependent fluorescence exists for the binary cataclysmics.