Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗

NREL Data Center Cuts Water Use in Half With Hybrid Thermosyphon System

In 2016, NREL installed a thermosyphon hybrid cooling system to reduce water use in the already extremely energy efficient data center at the Energy Systems Integration Facility. In this video, NREL Computational Science Center Director Steve Hammond describes how the system has successfully cut onsite water use in half without negative impacts to the data center’s energy efficient operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synthetic galaxy clusters and observations based on Dark Energy Survey Year 3 Data

ABSTRACT We develop a novel data-driven method for generating synthetic optical observations of galaxy clusters. In cluster weak lensing, the interplay between analysis choices and systematic effects related to source galaxy selection, shape measurement, and photometric redshift estimation can be best characterized in end-to-end tests going from mock observations to recovered cluster masses. To create such test scenarios, we measure and model the photometric properties of galaxy clusters and their sky environments from the Dark Energy Survey Year 3 (DES Y3) data in two bins of cluster richness $\lambda \in [30; 45)$, $\lambda \in [45; 60)$ and three bins in cluster redshift ($z\in [0.3; 0.35)$, $z\in [0.45; 0.5)$ and $z\in [0.6; 0.65)$. Using deep-field imaging data, we extrapolate galaxy populations beyond the limiting magnitude of DES Y3 and calculate the properties of cluster member galaxies via statistical background subtraction. We construct mock galaxy clusters as random draws from a distribution function, and render mock clusters and line-of-sight catalogues into synthetic images in the same format as actual survey observations. Synthetic galaxy clusters are generated from real observational data, and thus are independent from the assumptions inherent to cosmological simulations. The recipe can be straightforwardly modified to incorporate extra information, and correct for survey incompleteness. New realizations of synthetic clusters can be created at minimal cost, which will allow future analyses to generate the large number of images needed to characterize systematic uncertainties in cluster mass measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Big Data Mining for Applied Energy Savings in Buildings

Residential and commercial buildings in China, India, the United States (US), United Kingdom (UK), and Italy consume 39-45% of each nation's primary energy (approximately 73% of electricity). Building energy models can be used to automatically optimize the return-on-investment for retrofits to improve a building’s energy efficiency. However, with an average of 3,000 building descriptors necessary to accurately simulate a single building, there is a market need to reduce the transaction cost for creating a simulatable model for every building in a city and calibrate the models to utility data prior to capital expenditures. Oak Ridge National Laboratory has utilized two of the world’s fastest supercomputers, assembled unique datasets, and developed innovative algorithms for big data mining to produce the Automatic detection and creation of Building Energy Models (AutoBEM) technology for urban-scale energy modeling. The project developed the world’s most accurate method for determining building footprints from satellite imagery and the world’s fastest building energy model generator. The team has also leveraged a total of eight supercomputers to analyze the best methods, metrics, and algorithms for calibrating building models to measured data within 4% of hourly electricity use; well beyond current industry standards necessary for private-sector financing. The project developed the world’s fastest buildings simulator, over 8 million simulations totaling over 200TB, and mined this data with over 130,000 parallel artificial intelligence algorithmic instances to develop the world’s best calibration algorithm in terms of accuracy, runtime, and robustness.

New, Joshua↗

Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners

As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance of PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Materials Chemistry Integrating Theory, Experiment and Data Science (Final Report)

The Energy Materials Chemistry Integrating Theory, Experiment and Data Science (EM-CITED) project is a multidisciplinary research effort focused on accelerating discovery of scientific knowledge via incorporation of data science and artificial intelligence in materials chemistry research. The project aims to advance materials chemistry-aware data science to unify theory and experiment knowledge streams. The work resulted in foundational AI frameworks for materials chemistry – Deep Reasoning Networks (DRNets), Hierarchical Correlation Learning for Multi-property Prediction (H-CLMP), and Material-to-Spectrum (Mat2Spec) prediction – as well as a host of strategies for accelerated scientific discoveries through principled incorporation of data science in computational and experimental research.

36 MATERIALS SCIENCE↗

On the anisotropies of interplanetary low-energy proton intensities

Explorer 35 proton anisotropic flux data (proton energies between 0.3 and 6.3 MeV) and simultaneous magnetic field measurements were used to supply more information on the propagation characteristics of low-energy protons in the interplanetary medium. During the rising portions of the proton events, large field-aligned anisotropies were observed. During the decaying part of the proton events, either radial anisotropy or near-isotropy was noticed. In addition, certain observations made during the decaying part of the proton events revealed anisotropies deviating significantly from the radial direction.

Pesses, M. E.↗

Data Center Fact Sheet: DC Pro Software Tool Suite

This fact sheet describes how DOE's Data Center Energy Profiler (DC Pro) Software Tool Suite and other resources can help U.S. companies identify ways to improve the efficiency of their data centers.

97 MATHEMATICS AND COMPUTING↗

Fuzzy dark matter and the Dark Energy Survey Year 1 data

ABSTRACT Gravitational weak lensing by dark matter haloes leads to a measurable imprint in the shear correlation function of galaxies. Fuzzy dark matter (FDM), composed of ultralight axion-like particles of mass m ∼ 10−22 eV, suppresses the matter power spectrum and shear correlation with respect to standard cold dark matter. We model the effect of FDM on cosmic shear using the optimized halo model HMCode, accounting for additional suppression of the mass function and halo concentration in FDM as observed in N-body simulations. We combine Dark Energy Survey Year 1 (DES-Y1) data with the Planck cosmic microwave background anisotropies to search for shear correlation suppression caused by FDM. We find no evidence of suppression compared to the preferred cold dark matter model, and thus set a new lower limit to the FDM particle mass. Using a log-flat prior and marginalizing over uncertainties related to the non-linear model of FDM, we find a new, independent 95 per cent C.L. lower limit log10m > −23 combining Planck and DES-Y1 shear, an improvement of almost two orders of magnitude on the mass bound relative to CMB-only constraints. Our analysis is largely independent of baryonic modelling, and of previous limits to FDM covering this mass range. Our analysis highlights the most important aspects of the FDM non-linear model for future investigation. The limit to FDM from weak lensing could be improved by up to three orders of magnitude with $\mathcal {O}(0.1)$ arcmin cosmic shear angular resolution, if FDM and baryonic feedback can be simultaneously modelled to high precision in the halo model.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Center IT Equipment Energy Assessment Tools: Current State of Commercial Tools, Proposal for a Future Set of Assessment Tools

This research project, which was conducted during the Summer and Fall of 2011, investigated some commercially available assessment tools with a focus on IT equipment to see if such tools could round out the DC Pro tool suite. In this research, the assessment capabilities of the various tools were compiled to help make “non-biased” information available to the public. This research should not be considered to be exhaustive on all existing vendor tools although a number of vendors were contacted. Large IT equipment OEM’s like IBM and Dell provide their proprietary internal automated software which does not work on any other IT equipment. However, found two companies with products that showed promise in performing automated assessments for IT equipment from different OEM vendors. This report documents the research and provides a list of software products reviewed, contacts and websites, product details, discussions with specific companies, a set of recommendations, and next steps. As a result of this research, a simple 3-level approach to an IT assessment tool is proposed along with an example of an assessment using a simple IT equipment data collection tool (Level 1, spreadsheet). The tool has been reviewed with the Green Grid and LBNL staff. The initial feedback has been positive although further refinement to the tool will be necessary. Proposed next steps include a field trial of at least two vendors’ software in two different data centers with an objective to prove the concept, ascertain the extent of energy and computational assessment, ease of installation and opportunities for continuous improvement. Based on the discussions, field trials (or case studies) are proposed with two vendors – JouleX (expected to be completed in 2012) and Sentilla.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Telematics and Data Science: Informing Energy-Efficient Mobility

Fleets exploring the possibility of adding electric vehicles (EVs), battery electric vehicles (BEVs), and plug-in hybrid electric vehicles (PHEVs) seek an efficient, data-driven means to justify both expenditures for vehicle and charging infrastructure and the appropriate placement of them to help ensure the cost-effective adoption of these technologies. Exploring data collection and analytic methodologies across different telematics providers offers the opportunity to better understand the strengths, weaknesses, and possibilities for employing different methods of data collection, including smartphone-based telematics and more traditional telematics with hardware installed on a vehicle's onboard diagnostics port. This report presents results of five pilot programs that collected data from the operation of conventional light-duty fleet vehicles to generate recommendations for transitioning these fleet vehicles to EVs, implementing adequate charging infrastructure, and establishing management practices to maximize the benefits of these new fleet technologies.

33 ADVANCED PROPULSION SYSTEMS↗

Cosmic voids and void lensing in the Dark Energy Survey science verification data

Galaxies and their dark matter halos populate a complicated filamentary network around large, nearly empty regions known as cosmic voids. Cosmic voids are usually identified in spectroscopic galaxy surveys, where 3D information about the large-scale structure of the Universe is available. Although an increasing amount of photometric data is being produced, its potential for void studies is limited since photometric redshifts induce line-of-sight position errors of ~50 Mpc/h or more that can render many voids undetectable. In this paper we present a new void finder designed for photometric surveys, validate it using simulations, and apply it to the high-quality photo-z redMaGiC galaxy sample of the Dark Energy Survey Science Verification (DES-SV) data. The algorithm works by projecting galaxies into 2D slices and finding voids in the smoothed 2D galaxy density field of the slice. Fixing the line-of-sight size of the slices to be at least twice the photo- z scatter, the number of voids found in these projected slices of simulated spectroscopic and photometric galaxy catalogs is within 20% for all transverse void sizes, and indistinguishable for the largest voids of radius ~70 Mpc/h and larger. The positions, radii, and projected galaxy profiles of photometric voids also accurately match the spectroscopic void sample. Applying the algorithm to the DES-SV data in the redshift range 0.2 < z < 0.8 , we identify 87 voids with comoving radii spanning the range 18-120 Mpc/h, and carry out a stacked weak lensing measurement. With a significance of 4.4σ, the lensing measurement confirms the voids are truly underdense in the matter field and hence not a product of Poisson noise, tracer density effects or systematics in the data. In conclusion, it also demonstrates, for the first time in real data, the viability of void lensing studies in photometric surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Analysis Method for Hidden Damage Detection

A method of detecting internal defects in composites or other multilayer materials includes generating a wavefield on a surface of the material. Wavefield data is collected from the wavefield on the surface, and the measured wavefield data is processed to provide measured energy data. The method may include generating simulated or predicted energy data for the multilayer material that is compared to the simulated energy data to determine if the multilayer material has internal defects or damage below the surface. The method can be utilized to detect and/or quantify damage or other defects that are "hidden" by damage that is closer to the surface of the material.

Campbell Leckey, Cara A.↗

Combinatorial nuclear level-density model

A microscopic nuclear level-density model is presented. The model is a completely combinatorial (micro-canonical) model based on the folded-Yukawa single-particle potential and includes explicit treatment of pairing, rotational and vibrational states. The microscopic character of all states enables extraction of level distribution functions with respect to pairing gaps, parity and angular momentum. The results of the model are compared to available experimental data: neutron separation energy level spacings, data on total level-density functions from the Oslo method and data on parity ratios.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BuildingSync

BuildingSync® is a common schema for energy audit data that can be utilized by different software and databases involved in the energy audit process. It allows data to be more easily aggregated, compared and exchanged between different databases and software tools. This streamlines the energy audit process, improving the value of the data and facilitating achievement of greater energy efficiency.

Long, Nicholas↗

Inelastic Collisions of a Fermi Gas in the BEC-BCS Crossover

We measure inelastic three-body and two-body collisional decay rates for a two-component Fermi gas of {sup 6}Li, which are highly suppressed by the Pauli exclusion principle. Our measurements are made in the BEC-BCS crossover regime, near the two-body collisional (Feshbach) resonance. At high temperature (energy) the data show a dominant three-body decay process, which is studied as a function of bias magnetic field. At low energy, the data show a coexistence of two-body and three-body decay processes near and below the Feshbach resonance. Below resonance, the observed two-body inelastic decay can arise from molecule-atom and molecule-molecule collisions. We suggest that at and above resonance, an effective two-body decay rate arises from collisions between atoms and correlated (Cooper) pairs that can exist at sufficiently low temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Shell-Model Code NuShellX@MSU

Use of the code NuShellX@MSU is outlined. It connects to the ENSDF data files for automatic comparisons to energy level data. Operator overlaps provide predictions for spectroscopic factors, two-nucleon transfer amplitudes, nuclear moments, gamma decay and beta decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Usage of NASA's Near Real-Time Solar and Meteorological Data for Monitoring Building Energy Systems Using RETScreen International's Performance Analysis Module

This paper describes building energy system production and usage monitoring using examples from the new RETScreen Performance Analysis Module, called RETScreen Plus. The module uses daily meteorological (i.e., temperature, humidity, wind and solar, etc.) over a period of time to derive a building system function that is used to monitor building performance. The new module can also be used to target building systems with enhanced technologies. If daily ambient meteorological and solar information are not available, these are obtained over the internet from NASA's near-term data products that provide global meteorological and solar information within 3-6 days of real-time. The accuracy of the NASA data are shown to be excellent for this purpose enabling RETScreen Plus to easily detect changes in the system function and efficiency. This is shown by several examples, one of which is a new building at the NASA Langley Research Center that uses solar panels to provide electrical energy for building energy and excess energy for other uses. The system shows steady performance within the uncertainties of the input data. The other example involves assessing the reduction in energy usage by an apartment building in Sweden before and after an energy efficiency upgrade. In this case, savings up to 16% are shown.

Paul W Stackhouse, Jr.↗