Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

SUZAKU OBSERVATIONS OF LUMINOUS QUASARS: REVEALING THE NATURE OF HIGH-ENERGY BLAZAR EMISSION IN LOW-LEVEL ACTIVITY STATES

We present the results from the Suzaku X-ray observations of five flat-spectrum radio quasars (FSRQs), namely PKS 0208-512, Q 0827+243, PKS 1127-145, PKS 1510-089, and 3C 454.3. All these sources were additionally monitored simultaneously or quasi-simultaneously by the Fermi satellite in gamma rays and the Swift UVOT in the UV and optical bands, respectively. We constructed their broadband spectra covering the frequency range from 10{sup 14} Hz up to 10{sup 25} Hz, and those reveal the nature of high-energy emission of luminous blazars in their low-activity states. The analyzed X-ray spectra are well fitted by a power-law model with photoelectric absorption. In the case of PKS 0208-512, PKS 1127-145, and 3C 454.3, the X-ray continuum showed indication of hardening at low energies. Moreover, when compared with the previous X-ray observations, we see a significantly increasing contribution of low-energy photons to the total X-ray fluxes when the sources are getting fainter. The same behavior can be noted in the Suzaku data alone. A likely explanation involves a variable, flat-spectrum component produced via inverse-Compton emission, plus an additional, possibly steady soft X-ray component prominent when the source gets fainter. This soft X-ray excess is represented either by a steep power-law (photon indices {Gamma} {approx} 3-5) or a blackbody-type emission with temperatures kT {approx} 0.1-0.2 keV. We model the broadband spectra of the five observed FSRQs using synchrotron self-Compton and/or external-Compton radiation models. Our modeling suggests that the difference between the low- and high-activity states in luminous blazars is due to the different total kinetic power of the jet, most likely related to varying bulk Lorentz factor of the outflow within the blazar emission zone.

79 ASTRONOMY AND ASTROPHYSICS↗

On The Origin Of High Energy Correlations in Gamma-ray Bursts

I investigate the origin of the observed correlation between a gamma-ray burst's {nu}F{sub {nu}} spectral peak E{sub pk} and its isotropic equivalent energy E{sub iso} through the use of a population synthesis code to model the prompt gamma-ray emission from GRBs. By using prescriptions for the distribution of prompt spectral parameters as well as the population's luminosity function and co-moving rate density, I generate a simulated population of GRBs and examine how bursts of varying spectral properties and redshift would appear to a gamma-ray detector here on Earth. I find that a strong observed correlation can be produced between the source frame Epk and Eiso for the detected population despite the existence of only a weak and broad correlation in the original simulated population. The energy dependance of a gamma-ray detector's flux-limited detection threshold acts to produce a correlation between the source frame E{sub pk} and E{sub iso} for low luminosity GRBs, producing the left boundary of the observed correlation. Conversely, very luminous GRBs are found at higher redshifts than their low luminosity counterparts due to the standard Malquest bias, causing bursts in the low E{sub pk}, high E{sub iso} regime to go undetected because their E{sub pk} values would be redshifted to energies at which most gamma-ray detectors become less sensitive. I argue that it is this previously unexamined effect which produces the right boundary of the observed correlation. Therefore, the origin of the observed correlation is a complex combination of the instrument's detection threshold, the intrinsic cutoff in the GRB luminosity function, and the broad range of redshifts over which GRBs are detected. Although the GRB model presented here is a very simplified representation of the complex nature of GRBs, these simulations serve to demonstrate how selection effects caused by a combination of instrumental sensitivity and the cosmological nature of an astrophysical population can act to produce an artificially strong correlation between observed properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NEW FERMI-LAT EVENT RECONSTRUCTION REVEALS MORE HIGH-ENERGY GAMMA RAYS FROM GAMMA-RAY BURSTS

Based on the experience gained during the four and a half years of the mission, the Fermi-LAT Collaboration has undertaken a comprehensive revision of the event-level analysis going under the name of Pass 8. Although it is not yet finalized, we can test the improvements in the new event reconstruction with the special case of the prompt phase of bright gamma-ray bursts (GRBs), where the signal-to-noise ratio is large enough that loose selection cuts are sufficient to identify gamma rays associated with the source. Using the new event reconstruction, we have re-analyzed 10 GRBs previously detected by the Large Area Telescope (LAT) for which an X-ray/optical follow-up was possible and found four new gamma rays with energies greater than 10 GeV in addition to the seven previously known. Among these four is a 27.4 GeV gamma ray from GRB 080916C, which has a redshift of 4.35, thus making it the gamma ray with the highest intrinsic energy ({approx}147 GeV) detected from a GRB. We present here the salient aspects of the new event reconstruction and discuss the scientific implications of these new high-energy gamma rays, such as constraining extragalactic background light models, Lorentz invariance violation tests, the prompt emission mechanism, and the bulk Lorentz factor of the emitting region.

79 ASTRONOMY AND ASTROPHYSICS↗

Band Energy Dependence of Defect Formation in the Topological Semimetal Cd3As2

Cadmium Arsenide (Cd3As2) is a prototypical Dirac semimetal that manifests topological properties in a 3D bulk material. In defect-free Cd3As2, the Fermi level lies at a minimum in the density of states at the Dirac point, but experimentally it forms with excess electron carriers and an elevated EF, thereby masking the topological features. To computationally study the self-doping of Cd3As2, we combine density functional theory (DFT) calculations for defect formation energies with quasi-particle self-consistent GW (QSGW) electronic structure calculations. We demonstrate an innate dependence of the point defect formation energies on carrier concentrations and use the QSGW calculated density of states to extrapolate formation energies to arbitrary electron concentrations. This approach allows the quantitative modeling of thermodynamic defect equilibria in topological semimetals and is used to predict how Cd3As2 growth conditions affect the position of EF relative to the Dirac point.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS↗

Role of energy partitioning on electron-hole recombination, trapping, and detection in silicon detectors

The dynamics of electron-hole pair creation and transport in a semiconductor control the fundamental signal response for radiation detection. Extensive studies on silicon detectors have led to contradictory interpretations on the origins of the pulse height defect (PHD) and nonlinear response. In this study, recombination and trapping behaviors of a controlled number of electron-hole pairs produced within different volumes along the ion path are investigated, and the pulse height generated is analyzed in terms of energy partitioning. The results clearly demonstrate that a high recombination rate is not observed for heavy ions; moreover, significant trapping associated with the atomic defects produced by individual ions is responsible for the nonlinear response at low energies and PHD at high energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Measurements of Jet Substructure and Partonic Energy Loss in Au+Au Collisions at √ sNN = 200 GeV

The STAR collaboration presents jet substructure measurements related to both the momentum fraction and the opening angle within jets in p+p and Au+Au collisions at √sNN =200GeV. The substructure observables include SoftDrop groomed momentum fraction (zg), groomed jet radius (Rg), and subjet momentum fraction (zSJ) and opening angle (θSJ). The latter observable is introduced for the first time. Fully corrected subjet measurements are presented for p+p collisions and are compared to leading-order Monte Carlo models. The subjet θSJ distributions reflect the jets leading opening angle and are utilized as a proxy for the resolution scale of the medium in Au+Au collisions. We compare data from Au+Au collisions to those from p+p which are embedded in minimum-bias Au+Au events in order to include the effects of detector smearing and the heavy-ion collision underlying event. The subjet observables are shown to be more robust to the background than zg and Rg. We observe no significant modifications of the subjet observables within the two highest-energy, back-to-back jets, resulting in a distribution of opening angles and the splittings that are vacuumlike. We also report measurements of the differential dijet momentum imbalance (AJ) for jets of varying θSJ. We find no qualitative differences in energy loss signatures for varying angular scales in the range 0.1< θSJ<0.3, leading to the possible interpretation that energy loss in this population of high-momentum dijet pairs, is due to soft medium-induced gluon radiation from a single color charge as it traverses the medium.

Abdallah, M. S.↗

Rotational energy term in the empirical formula for the yrast energies in even-even nuclei

We show that part of the empirical formula describing the gross features of the measured yrast energies of the natural parity even multipole states for even-even nuclei can be related to the rotational energy of nuclei. When the first term of the empirical formula, {alpha}A{sup -{gamma}}, is regarded as the rotational energy, we can better understand the results of the previous analyses of the excitation energies. We show that the values of the parameters {alpha} and {gamma} newly obtained by considering the {alpha}A{sup -{gamma}} term as the rotational energy of a rigid rotor are remarkably consistent with those values extracted from the earlier 'modified'{chi}{sup 2} analyses, in which we use the logarithms of the excitation energies in defining the 'modified'{chi}{sup 2} values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New low-energy 0 + state and shape coexistence in Ni 70

We report that in recent models, the neutron-rich Ni isotopes around N=40 are predicted to exhibit multiple low-energy excited 0 + states attributed to neutron and proton excitations across both the N=40 and Z=28 shell gaps. In 68 Ni, the three observed 0 + states have been interpreted in terms of triple shape coexistence between spherical, oblate, and prolate deformed shapes. In the present work a new (0 2 + ) state at an energy of 1567 keV has been discovered in 70 Ni by using β-delayed, γ-ray spectroscopy following the decay of 70 Co. The precipitous drop in the energy of the prolate-deformed 0 + level between 68 Ni and 70 Ni with the addition of two neutrons compares favorably with results of Monte Carlo shell-model calculations carried out in the large f pg9/2 d 5/2 model space, which predict a 0 2 + state at 1525 keV in 70 Ni. Finally, the result extends the shape-coexistence picture in the region to 70 Ni and confirms the importance of the role of the tensor component of the monopole interaction in describing the structure of neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Factorization of low-energy gluons in exclusive processes

We outline a proof of factorization in exclusive processes, taking into account the presence of soft and collinear modes of arbitrarily low energy, which arise when the external lines of the process are taken on shell. Specifically, we examine the process of e{sup +}e{sup -} annihilation through a virtual photon into two light mesons. In an intermediate step, we establish a factorized form that contains a soft function that is free of collinear divergences. In contrast, in soft-collinear effective theory, the low-energy collinear modes factor most straightforwardly into the soft function. We point out that the cancellation of the soft function, which relies on the color-singlet nature of the external hadrons, fails when the soft function contains low-energy collinear modes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tau energy loss and ultrahigh energy skimming tau neutrinos

For this paper, we consider propagation of high-energy earth-skimming taus produced in interactions of astrophysical tau neutrinos. For astrophysical tau neutrinos, we take generic power-law flux, E -2 and the cosmogenic flux initiated by the protons. We calculate tau energy loss in several approaches, such as dipole models and the phenomenological approach in which parametrization of the F 2 is used. We evaluate the tau neutrino charged-current cross section using the same approaches for consistency. We find that uncertainty in the neutrino cross section and in the tau energy loss partially compensate giving very small theoretical uncertainty in the emerging tau flux for distances ranging from 2 to 100 km and for the energy range between 10 6 and 10 11 GeV , focusing on energies above 10 8 GeV . When we consider uncertainties in the neutrino cross section, inelasticity in neutrino interactions and the tau energy loss, which are not correlated, i.e. they are not all calculated in the same approach, theoretical uncertainty ranges from about 30% and 60% at 10 8 GeV to about factors of 3.3 and 3.8 at 10 11 GeV for the E -2 flux and the cosmogenic flux, respectively, for the distance of 10 km rock. The spread in predictions significantly increases for much larger distances, e.g., ~ 1,000 km . Most of the uncertainty comes from the treatment of photonuclear interactions of the tau in transit through large distances. We also consider Monte Carlo calculation of the tau propagation and we find that the result for the emerging tau flux is in agreement with the result obtained using analytic approach. Our results are relevant to several experiments that are looking for skimming astrophysical taus, such as the Pierre Auger Observatory, HAWC and Ashra. We evaluate the aperture for the Auger and discuss briefly application to the other two experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal modifications of mesons and energy-energy correlators from real-time simulations of a 𝑈⁡(1) lattice gauge theory

We investigate thermal properties of a 𝑈⁡(1) lattice gauge theory in 1 + 1 dimensions through real-time simulations. We extract the spectral functions directly coupling to the pseudoscalar and scalar mesons, demonstrating the thermal modifications of these states with increasing temperatures. Introducing the notion of energy-flow operators, we quantify the temporal buildup of correlations in the energy flows across the lattice. We demonstrate that energy-energy correlators fail to factorize to products of energy flows, both in the vacuum and at nonzero temperature, indicating the presence of nontrivial correlations in the quantum states. Our results constitute a first real-time ab initio study of bound-state thermal broadening and finite temperature energy-flow correlations in a gauge theory, providing a benchmark for future studies of hadronic matter under extreme conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data-Driven Modeling and Optimization of Building Energy Consumption: a Case Study

Installing sensors and Building Automation Systems (BAS) allows controlling the facility operations while generating data that can be analyzed for model development. This work focuses on data-driven modeling of the building to optimize energy consumption. The City of Orlando aims to reduce its energy consumption so, they provided us access to their BAS for data and studying the operation of its facilities. We selected a mid-size pilot building to conduct data analysis and modeling. We develop an Application Programming Interface (API) to login to the servers and scrape data. The scraped data contains features ranging from environmental conditions to equipment activity. This dataset is a time series so, it's handled in accordance and analyzed to investigate patterns and relations between data points that help choose parameters for predictive models for building and equipment. Finally, the models are optimized to reduce the energy consumption of the facility.

Grover, Divas↗

Sizing Energy Storage to Accommodate High Penetration of Variable Energy Resources

Abstract—The variability and non-dispatchable nature of wind and solar energy production presents substantial challenges for maintaining system balance. Depending on the economic considerations, energy storage can be a viable solution to balance energy production with consumption. This paper proposes to use discrete Fourier transform to decompose the required balancing power into different time-varying periodic components, i.e., intra-week, intra-day, intra-hour, and real-time. Each component can be used to quantify the maximum energy storage requirement for different types of energy storage. This requirement is the physical limit that could be theoretically accommodated by a power system. The actual energy storage capacity can be further quantified within this limit by the cost-benefit analysis (future work). The proposed approach has been successfully used in a study conducted for the 2030 Western Electricity Coordinating Council (WECC) system model. Some results of this study are provided in this paper.

Makarov, Yuri V.↗

A novel multifunctional energy system (MES) for CO{sub 2} removal with zero energy penalty - article no. 021401

This paper proposes a novel, multifunctional energy system (MES), in which hydrogen and electricity are cogenerated and about 90% of CO{sub 2} is removed. By integrating the methane steam reforming reaction and combustion of coal, the natural gas and coal are utilized synthetically, and coal is burned to provide high-temperature thermal energy to the methane steam reforming reaction. Afterwards, the resulting syngas enters a pressure swing adsorption (PSA) unit to separate about 70% of hydrogen, thereby significantly increasing the concentration of carbon dioxide from nearly 20% to 43% in the PSA tail gas. As a result, the overall efficiency of the new system becomes 63.2%. Compared to a conventional natural gas-based hydrogen plant and a coal-firing steam power plant without CO{sub 2} removal (the overall efficiency of the two systems is 63.0%), the energy penalty for CO{sub 2} removal in the new system is almost totally avoided. Based on the graphical exergy analysis, we propose that the integration of synthetic utilization of fossil fuel (natural gas and coal) and the CO{sub 2} removal process plays a significant role in zero energy penalty for CO{sub 2} removal and its liquefaction in the MES. The result obtained here provides a new approach for CO{sub 2} removal with zero or low thermal efficiency reduction (energy penalty) within an energy system.

20 FOSSIL-FUELED POWER PLANTS↗

SU‐C‐105‐05: Reference Dosimetry of High‐Energy Electron Beams with a Farmer‐Type Ionization Chamber

Purpose: To investigate gradient effects and provide Monte Carlo calculated beam quality conversion factors to characterize the Farmer‐type NE2571 ion chamber for high‐energy reference dosimetry of clinical electron beams. Methods: The EGSnrc code system is used to calculate the absorbed dose to water and to the gas in a fully modeled NE2571 chamber as a function of depth in a water phantom. Electron beams incident on the surface of the phantom are modeled using realistic BEAMnrc accelerator simulations and electron beam spectra. Beam quality conversion factors are determined using calculated doses to water and to air in the chamber in high‐energy electron beams and in a cobalt‐60 reference field. Calculated water‐to‐air stopping power ratios are employed for investigation of the overall ion chamber perturbation factor. Results: An upstream shift of 0.3–0.4 multiplied by the chamber radius, r-cav, both minimizes the variation of the overall ion chamber perturbation factor with depth and reduces the difference between the beam quality specifier (R{sub 5} {sub 0}) calculated using ion chamber simulations and that obtained with simulations of dose‐to‐water in the phantom. Beam quality conversion factors are obtained at the reference depth and gradient effects are optimized using a shift of 0.2r-cav. The photon‐electron conversion factor, k-ecal, amounts to 0.906 when gradient effects are minimized using the shift established here and 0.903 if no shift of the data is used. Systematic uncertainties in beam quality conversion factors are investigated and amount to between 0.4 to 1.1% depending on assumptions used. Conclusion: The calculations obtained in this work characterize the use of an NE2571 ion chamber for reference dosimetry of high‐energy electron beams. These results will be useful as the AAPM continues to review their reference dosimetry protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification

Purpose: Cone-beam CT (CBCT) with a flat-panel detector (FPD) is finding application in areas such as breast and musculoskeletal imaging, where dual-energy (DE) capabilities offer potential benefit. The authors investigate the accuracy of material classification in DE CBCT using filtered backprojection (FBP) and penalized likelihood (PL) reconstruction and optimize contrast-enhanced DE CBCT of the joints as a function of dose, material concentration, and detail size. Methods: Phantoms consisting of a 15 cm diameter water cylinder with solid calcium inserts (50–200 mg/ml, 3–28.4 mm diameter) and solid iodine inserts (2–10 mg/ml, 3–28.4 mm diameter), as well as a cadaveric knee with intra-articular injection of iodine were imaged on a CBCT bench with a Varian 4343 FPD. The low energy (LE) beam was 70 kVp (+0.2 mm Cu), and the high energy (HE) beam was 120 kVp (+0.2 mm Cu, +0.5 mm Ag). Total dose (LE+HE) was varied from 3.1 to 15.6 mGy with equal dose allocation. Image-based DE classification involved a nearest distance classifier in the space of LE versus HE attenuation values. Recognizing the differences in noise between LE and HE beams, the LE and HE data were differentially filtered (in FBP) or regularized (in PL). Both a quadratic (PLQ) and a total-variation penalty (PLTV) were investigated for PL. The performance of DE CBCT material discrimination was quantified in terms of voxelwise specificity, sensitivity, and accuracy. Results: Noise in the HE image was primarily responsible for classification errors within the contrast inserts, whereas noise in the LE image mainly influenced classification in the surrounding water. For inserts of diameter 28.4 mm, DE CBCT reconstructions were optimized to maximize the total combined accuracy across the range of calcium and iodine concentrations, yielding values of ∼88% for FBP and PLQ, and ∼95% for PLTV at 3.1 mGy total dose, increasing to ∼95% for FBP and PLQ, and ∼98% for PLTV at 15.6 mGy total dose. For a fixed iodine concentration of 5 mg/ml and reconstructions maximizing overall accuracy across the range of insert diameters, the minimum diameter classified with accuracy >80% was ∼15 mm for FBP and PLQ and ∼10 mm for PLTV, improving to ∼7 mm for FBP and PLQ and ∼3 mm for PLTV at 15.6 mGy. The results indicate similar performance for FBP and PLQ and showed improved classification accuracy with edge-preserving PLTV. A slight preference for increased smoothing of the HE data was found. DE CBCT discrimination of iodine and bone in the knee was demonstrated with FBP and PLTV at 6.2 mGy total dose. Conclusions: For iodine concentrations >5 mg/ml and detail size ∼20 mm, material classification accuracy of >90% was achieved in DE CBCT with both FBP and PL at total doses <10 mGy. Optimal performance was attained by selection of reconstruction parameters based on the differences in noise between HE and LE data, typically favoring stronger smoothing of the HE data, and by using penalties matched to the imaging task (e.g., edge-preserving PLTV in areas of uniform enhancement)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗