Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Emergency power system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Solar Photovoltaics: Supply Chain Deep Dive Assessment

This is one of a series of reports and deep dive assessments produced in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. Over the past decade, solar power has gone from an emerging, niche technology to a mature energy industry. By 2035, solar power could supply 40% or more of U.S. electricity demand, dramatically accelerating the decarbonization of buildings, transportation, and industry; and, if current technology trends continue, it could do so without increasing the price of electricity. The rapid expansion of solar energy has the potential to yield broad benefits in the form of economic activity and workforce development. The solar industry already employs roughly 230,000 people in the United States, at an average wage that is higher than the national average for most comparable positions. By decarbonizing the electricity sector by 2035, the U.S. solar industry could employ 500,000–1,500,000 people by 2030. The components that are assembled to install a photovoltaic power system are produced by a global supply chain. Photovoltaic (PV) modules (also called panels) are made of cells that use a variety of technologies. There are two leading types of solar modules used in the United States, with crystalline silicon (c-Si) modules representing 84% of the market and cadmium telluride (CdTe) modules representing 16% of the market. Modules of either type require mounting structures to provide mechanical support (racking), which may be configured to follow the sun (tracking). The output of any PV module is direct current (dc), which is almost always converted to alternating current (ac) by an inverter.

14 SOLAR ENERGY↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - November 2022 Meeting Notes and Information Request Status

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. commercial nuclear power plants. This document summarizes results from the Fiscal Year 2023 (FY2023) U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy, is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Fukushima-related information and associated discussions during these meetings benefit operating, new, and advanced reactors. Significant safety insights have been and are continuing to be obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, Daiichi-related activities, such as code modeling improvements and analysis, testing, and new technology deployment efforts, have the potential to offer additional benefits to the operating fleet and new LWR and non-LWR designs. U.S. evaluations of obtained examination information and input regarding future Daiichi examinations are of interest to several organizations within Japan. Since its inception, the U.S. has provided consensus input for high priority time-sequenced examination tasks and supporting research activities. In their Mid-to-Long-term Examination Plan for 1F investigations, TEPCO included all remaining U.S. consensus information requests and additional information requests they identified. TEPCO periodically provides reports on the status of these requests (reflecting D&D priorities, new insights from investigations, and new technologies that become available). Hence, U.S. experts agreed that it was appropriate for TEPCO to track and prioritize these information requests as D&D progresses. U.S. experts will continue to review and comment on the information obtained from examinations and, as needed, provide additional details and relevant background material to support future examinations. As documented in this report, several other items, such as additional details on information requests pertaining to ex-vessel examinations, relevant references from prior research, additional documents to provide insights regarding recent investigation findings, and reviews of recently released documents, were agreed to during the FY2023 meeting.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Deterministic Current–Induced Perpendicular Switching in Epitaxial Co/Pt Layers without an External Field

Current–induced spin–orbit torques (SOTs) have emerged as a powerful tool to control magnetic elements and non–uniform magnetic textures such as domain walls and skyrmions. SOT–induced switching of perpendicular magnetization generally requires an external field to break the rotational symmetry of the spin–orbit effective fields responsible for the deterministic reversal. The proposed mechanisms to eliminate this requirement often rely on complex multilayer structures that necessitate laborious optimization in the material and spin transport properties, making them less attractive for applications. Herein, current–induced, external field–free switching of an epitaxial MgO/Pt/Co trilayer with an extremely large perpendicular anisotropy in excess of 3 Tesla is reported. It is found that switching occurs due to the interplay of strong SOTs, local anisotropy fluctuations, and the Dzyaloshinkii–Moriya interaction inherent to this epitaxial system. Finally, given that these layers constitute the base stack of a magnetic tunnel junction, this switching mechanism offers the most technologically viable path toward devices such as field–free SOT–based magnetic random–access memories.

36 MATERIALS SCIENCE↗

Synergy of Liquid-Crystalline Small-Molecule and Polymeric Donors Delivers Uncommon Morphology Evolution and 16.6% Efficiency Organic Photovoltaics

Achieving an ideal morphology is an imperative avenue for enhancing key parameters toward high-performing organic solar cells (OSCs). Among a myriad of morphological-control methods, the strategy of incorporating a third component with structural similarity and crystallinity difference to construct ternary OSCs has emerged as an effective approach to regulate morphology. A nematic liquid-crystalline benzodithiophene terthiophene rhodamine (BTR) molecule, which possesses the same alkylthio-thienyl-substituted benzo moiety but obviously stronger crystallinity compared to classical medium-bandgap polymeric donor PM6, is employed as a third component to construct ternary OSCs based on a PM6:BTR:Y6 system. The doping of BTR (5 wt%) is found to be enough to improve the OSC morphology—significantly enhancing the crystallinity of the photoactive layer while slightly reducing the donor/acceptor phase separation scale simultaneously. Rarely is such a morphology evolution reported. It positively affects the electronic properties of the device—prolongs the carrier lifetime, shortens the photocurrent decay time, facilitates exciton dissociation, charge transport, and collection, and ultimately boosts the power conversion efficiency from 15.7% to 16.6%. This result demonstrates that the successful synergy of liquid-crystalline small-molecule and polymeric donors delicately adjusts the active-layer morphology and refines device performance, which brings vibrancy to the OSC research field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A review of crosstalk polymorphic circuits and their scalability

Using a control variable, the functionality of Polymorphic circuits can be modified, making them adaptable and useful for reconfiguring circuit behavior — all the way from gate level to system level. State-of-the art polymorphic circuits are based on custom non-linear circuit design or emerging devices such as ambipolar FET, configurable magnetic devices etc. While some of these approaches are inefficient in performance, others involve exotic devices. The Crosstalk computing based polymorphic circuits offer a fresh perspective. In Crosstalk, the interconnect interference between nanoscale metal lines is intentionally engineered to exhibit the programmable Boolean logic behavior. This approach relies on the coupling between metal lines and not on the transistors for computing, resulting in better scalability, security by obscurity, and fault tolerance by reconfiguration. Our novel approach is backed by the mathematical formulation that conveys the rationale to generalize and achieve a wide variety of polymorphic circuits. Our experiments, including design, simulation, and Power Performance Area (PPA) characterization results indicate that crosstalk circuits provide significant improvement in transistor count (about 3x), switching energy (2x), and speed (1.5x) for polymorphic logic circuits. In the best-case scenario, the transistor count reduction is 5x. This paper presents Crosstalk computing’s fundamentals, polymorphism and the scalability aspects to compete/co-exist with CMOS for digital logic implementations below 10 nm. Our scalability study uses Open Source 7 nm PDK, considers all process variation aspects and accommodates worst-case scenarios. The study results for various benchmark circuits show that the Crosstalk technology is a viable alternative to CMOS for digital logic implementations below 10 nm, having 48% density, 57% power, and 10% performance gains over equivalent CMOS counterparts. Finally, we compare Crosstalk Polymorphic Circuit design technique with similar approaches described in related works and discuss its features and constraints.

97 MATHEMATICS AND COMPUTING↗

On the Investigation of Phase Fault Classification in Power Grid Signals: A Case Study for Support Vector Machines, Decision Tree and Random Forest

In monitoring the power grid, an ability to differentiate between fault types is essential to ensuring electrical safety. Accordingly, this study introduces a fault detection and classification method by considering different machine learning (ML) and feature extraction (FE) methods combinations. Specifically, the proposed method is established in two classification layers; the first layer determines the fault, and the second layer distinguishes the type of fault. Based on the proposed system model, this study seeks to determine the influential data attributes in a power grid signal using FE methods, including fast Fourier transform, power spectral density (PSD), auto-correlation, and wavelet transform (WT). A cross-comparison of the effectiveness of the Support Vector Machine (SVM), Decision Tree (DT), and Random Forest (RF) is also performed to accomplish the classification layers of the proposed method. The designed algorithm is analyzed under the various combinations of FE and ML methods, and outcomes are presented by considering the trade-off between computational complexity and prediction accuracy. The results reveal that the RF-based ML algorithm shows the most accurate classification performance with PSD, and the most time-saving of the models is the DT WT. Also, SVM emerges superior on a subsequent test of the simulated models on real-world signals.

Galbraith, Kelli↗

Unconventional Spin-Orbit Torques Due to Reduced Crystal Symmetries

Spin-orbit torques have emerged as a powerful mechanism for manipulating magnetic moments in spintronic devices, offering a pathway to more efficient and scalable memory and logic technologies. While conventional spin-orbit torques generated in heavy metals and topological insulators have been extensively studied, recent advancements in unconventional spin-orbit torques demonstrated out-of-plane spin polarizations that could effectively switch perpendicular magnetizations without the need for additional external in-plane magnetic fields, promising significant implications for the development of energy-efficient and compact spintronic devices. Unconventional spin-orbit torques are usually found in materials with low symmetries, such as transition metal dichalcogenides, topological insulators, and 2-D materials. Here, we provide a brief overview of unconventional spin-orbit torques and present two example material systems: CrPt 3 and MoTe 2 , both exhibiting strong spin-orbit coupling and phase-dependent spin-orbit torques, and focus on their unique origins and potential applications. We discuss the roles of magnetic and crystallographic orders in generating unconventional spin-orbit torques, highlighting how these factors contribute to the observed anisotropic and directional dependencies.

magnetic films↗

Energy-efficient scientific computing using chemical reservoirs

The rapid growth of computing demands driven by scientific computing, data analytics, and artificial intelligence (AI) advancements has exposed the limitations of traditional digital processing systems. These systems are nearing physical energy barriers, making significant gains in energy efficiency increasingly unattainable. As we advance toward post-exascale computing, disruptive approaches are critical to overcoming these limitations. Among emerging analog solutions, biochemical computing offers a transformative path for achieving orders-of-magnitude improvements in energy efficiency. By leveraging the natural optimization capabilities of chemical reaction networks (CRNs), biochemical systems have the potential to meet high-performance computing needs through natural scalability. However, numerous challenges remain, including theoretical limitations in mapping computational problems to CRNs and practical barriers in implementing biochemical computing devices. In this paper, we present a framework for chemical computation using biochemical systems and introduce key components of our approach for energy-efficient scientific computing. We showcase the feasibility of this framework by solving a system of ordinary differential equations by emulating a chemical reservoir device, demonstrating its potential for addressing modern computing challenges. This work lays a foundational step toward harnessing the computational power of chemistry to design energy-efficient, scalable, high-performance next-generation computing systems.

Johnson, Connah G. M. [Pacific Northwest National ↗

Numerical fluid dynamics for FRG flow equations: Zero-dimensional QFTs as numerical test cases. I. The O ( N ) model

The functional renormalization group (FRG) approach is a powerful tool for studies of a large variety of systems, ranging from statistical physics over the theory of the strong interaction to gravity. The practical application of this approach relies on the derivation of so-called flow equations, which describe the change of the quantum effective action under the variation of a coarse-graining parameter. In the present work, we discuss in detail a novel approach to solve such flow equations. This approach relies on the fact that RG equations can be rewritten such that they exhibit similarities with the conservation laws of fluid dynamics. This observation can be exploited in different ways. First of all, we show that this allows to employ powerful numerical techniques developed in the context of fluid dynamics to solve RG equations. In particular, it allows us to reliably treat the emergence of nonanalytic behavior in the RG flow of the effective action as it is expected to occur in studies of, e.g., spontaneous symmetry breaking. Second, the analogy between RG equations and fluid dynamics offers the opportunity to gain novel insights into RG flows and their interpretation in general, including the irreversibility of RG flows. Further, we work out this connection in practice by applying it to zero-dimensional quantum-field theoretical models. The generalization to higher-dimensional models is also discussed. Our findings are expected to help improving future FRG studies of quantum field theories in higher dimensions both on a qualitative and quantitative level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of IEC 62443 Standard Gaps for Electric Grid Substation Model Use Case

This report presents an evaluation of the IEC 62443 standards in the context of electric grid substations, as part of a collaborative effort among Sandia National Laboratories (SNL), Idaho National Laboratory (INL), and the National Renewable Energy Laboratory (NREL). The primary objective is to assess the applicability of these standards to enhance cybersecurity measures for industrial automation and control systems (IACS) within the energy sector. The evaluation identifies strengths, such as the scalability of security levels and the structured lifecycle guidance provided by IEC 62443. However, it also highlights significant gaps, including limited integration of physical security, insufficient guidance for legacy systems, and challenges in addressing emerging threats like supply chain vulnerabilities. Recommendations for refining the standards are proposed, including the need for tailored guidance for securing legacy systems, integrating physical security with cybersecurity frameworks, and enhancing interoperability across multi-vendor environments. By addressing these gaps, the IEC 62443 standards can be strengthened to ensure comprehensive cybersecurity for electric grid substations, thereby supporting the resilience and reliability of critical energy infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cold-End Subsystem Testing for the Fission Power System Technology Demonstration Unit

The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodiumpotassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated coldend fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to highcost composite radiators in an end-to-end TDU test.

Briggs, Mazwell↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Digital quantum magnetism on a trapped-ion quantum computer

Digital quantum matter—realized when discrete quantum gates approximate continuous time evolution—is susceptible to heating into chaotic, structureless states. If digitization errors are adequately suppressed, a long-lived transient regime of approximately energy-conserving dynamics can be observed on gate-based quantum computers. Conservation of energy, in turn, enables the exploration of a wide variety of complex behaviours observed in equilibrium systems, ranging from the non-trivial microscopic origins of thermalization itself to the stabilization of effective models hosting exotic emergent properties. Here we use Quantinuum’s H2 quantum computer to simulate digitized dynamics of the quantum Ising model, suppressing digitization errors well enough to observe thermalization on timescales that severely challenge classical simulation methods. Relaxation of an inhomogeneous state reveals an emergent hydrodynamics owing to approximate energy conservation and we compute the associated diffusion constant. By reprogramming our simulations to take place on a triangular lattice with periodic boundary conditions, we observe thermalization consistent with emergent gauge and topological constraints resulting from lattice frustration. Furthermore, our results were enabled by continued advances in two-qubit gate quality (native partial entangler fidelities of 99.94(1)%) and establish digital quantum computers as powerful tools for studying (effectively) continuous-time dynamics.

Information theory and computation↗

A figure of merit for competing communications satellite designs

Trends in launch schedules, weights, power, and space segment costs per transponder year for Intelsats and North American domsats (domestic communications satellites) are discussed. The Intelsat system currently services 25,000 point to point telephone links at any one moment, and a $3 billion order has been placed for Intelsat VIs, which feature 36,000 telephone circuits each. The Intelsat VI spacecraft will weigh 1670 kg in orbit, a continuance of the trend to heavier satellites, while the domsats will stay at 650 kg due to launch vehicle limitations. Direct television broadcast satellites are being designed for receive only (R/O) earth stations, with each satellite capable of servicing 50,000 individual ground stations. Competition is growing for C and Ku band satellite transponders for DBS, with costs $350,000 each. No standardized design has yet emerged.

Lovell, R. R.↗

Machine Learning for Real-time Fusion Plasma Behavior Prediction and Manipulation (Final Report)

The goal of this project is to implement real-time analysis of 2D Beam Emission Spectroscopy (BES) data to predict and control transient and high-bandwidth events at DIII-D. In essence, we wish to bring high-bandwidth fluctuation diagnostics into the realm of real-time measurements and control. The BES ML models will necessarily be deep neural networks (DNN) with a “data flow” architecture for compatibility with high-throughput, low-latency evaluation on a field-programmable gate array (FPGA) or other emerging processor technologies. The real-time output will be fed to the plasma control system (PCS) for real-time control tasks, specifically for ELM control and avoidance and for QH-mode access and sustainment. We anticipate that the real-time analysis of fluctuation diagnostics will create new enabling technologies to predict and control transient events such as confinement mode transitions, edge-localized modes, Alfven eigenmode events, and disruptions. The proposed research is aligned with ITER research needs and DIII-D programmatic goals. For instance, the prediction and avoidance of ELM events is critical for ITER machine safety. Also, H-mode access with RMP ELM suppression in ITER is an active research area due to high separatrix density, narrow SOL width, and elevated LH transition power threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reach performance while wearing the Space Shuttle launch and entry suit during exposure to launch accelerations

Crewmen aboard the Space Shuttle are subjected to accelerations during ascent (the powered flight phase of launch) which range up to +3 G(sub x). Despite having 33 missions and nine years experience, not to mention all the time spent in development prior to the first flight, no truly quantitative reach study wearing actual crew equipment, using actual Shuttle seats and restraints has ever been done. What little information exists on reach performance while under acceleration has been derived primarily from subjective comments gathered retrospectively from Shuttle flight crews during their post mission debrief. This lack of reach performance data has resulted in uncertainty regarding emergency procedures that can realistically be performed during and actual Shuttle ascent versus what is practiced in the ground-fixed and motion-based Shuttle Simulators. With the introduction on STS-26 of the current Shuttle escape system, the question of reach performance under launch accelerations was once again raised. The escape system's requirement that each crewman wear a Launch/Entry Suit (LES), parachute harness, and parachute were all anticipated to contribute to a further degradation of reach performance during Shuttle ascent accelerations. In order to answer the reach performance question in a quantitative way, a photogrammetric method was chosen so that the actual reach values and associated envelopes could be captured. This would allow quantitative assessment of potential task performance impact and identify areas where changes to our Shuttle ascent emergency procedures might be required. Also, such a set of reach values would be valid for any similar acceleration profile using the same crew equipment. Potential Space Station applications of this data include predicting reach performance during Assured Crew Return Vehicle (ACRV) operations.

Bagian, James P.↗

Cold-end Subsystem Testing for the Fission Power System Technology Demonstration Unit

The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.

Briggs, Maxwell↗