Nuclear-Driven Integrated Energy Systems: A State-of-the-Art Review

Because of the growing concerns regarding climate change and energy sustainability, a transition toward a modern energy sector that reduces environmental effects while promoting social and economic growth has gained traction in recent years. Sustainable energy solutions, which include renewable and low-carbon sources such as nuclear energy and natural gas, could minimize emissions of greenhouse gases, enhance air and water quality, and encourage energy independence. Yet, the shift to a sustainable energy industry is fraught with difficulties, including governmental and regulatory obstacles, technological and economic limits, and societal acceptability hurdles. Addressing these issues would necessitate the development of long-term, durable, and cost-effective energy systems containing nuclear energy and associated with the generation of both electricity and other by-products required by industry. Integrated energy systems (IES) are a novel way to maximize the use of various energy resources and technologies in order to deliver dependable, efficient, and sustainable energy services. IES entail the integration of various energy systems, such as electricity, heating, cooling, and transportation, in respect to energy sustainability and a system’s resilience and flexibility. Their development and implementation require the cooperation of several parties, including energy providers and policymakers. This study provides a state-of-the-art literature review of the most creative nuclear-driven hybrid energy system applications and methodologies, from which the research challenges and prospects for effective IES implementation emerge.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

3D Numerical Simulation of Kink-driven Rayleigh–Taylor Instability Leading to Fast Magnetic Reconnection

Fast magnetic reconnection involving non-MHD microscale physics is thought to underlie both solar eruptions and laboratory plasma current disruptions. While there is extensive research on both the MHD macroscale physics and the non-MHD microscale physics, the process by which large-scale MHD couples to the microscale physics is not well understood. An MHD instability cascade from a kink to a secondary Rayleigh–Taylor instability in the Caltech astrophysical jet laboratory experiment provides new insights into this coupling and motivates a 3D numerical simulation of this transition from large to small scale. A critical finding from the simulation is that the axial magnetic field inside the current-carrying dense plasma must exceed the field outside. In addition, the simulation verifies a theoretical prediction and experimental observation that, depending on the strength of the effective gravity produced by the primary kink instability, the secondary instability can be Rayleigh–Taylor or mini-kink. Finally, it is shown that the kink-driven Rayleigh–Taylor instability generates a localized electric field sufficiently strong to accelerate electrons to very high energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conflicts of Greens’ in Renewable Energy Landscapes: Case Studies and a Planning Framework

Reducing greenhouse gas emissions (GHG) through renewable energy deployment is a goal for many cities and nations to mitigate the effects of a rapidly changing climate while securing energy needs. Given national and state level policies on green energy to achieve GHG reduction targets, localities are considering utility-scale renewable energy (USRE) facilities on remote lands, rural areas, oceans, coastal waters and large rivers to meet the energy needs for urban residents and industries. Although these USRE facilities generate much “greener” electricity than fossil fuel power plants, locating them can pose conflicts with wildlife, including endangered, threatened and/or special status species, and the habitats that support wildlife populations (Brunette et al., 2013; Gasparatos et al. 2016; Mulvaney 2017), which lead to a “Conflict of Greens” (Ko et al., 2011). In addition to ecological impacts, conflicts over social and cultural resources in local communities lead to concerns over environmental justice, in this context “energy justice,” where negative environmental, social, and economic impacts of energy projects fall more heavily upon marginalized, vulnerable, or indigenous communities. The Pacific Rim region is a center of major and growing economies, and it has become a battlefield for competing “green” objectives. In addition to progressive renewable energy goals, such as in California, Hawaii, and Taiwan, countries around the Pacific Rim have the majority of the growth in manufacturing of wind and solar energy devices and also some of the highest levels of renewables deployment with China, India, and the US leading the way in wind and solar installations. Developing renewable energy source in the ocean such as offshore wind, tidal, and wave energy, are beginning to add to this mix. Given this challenge, the APRU SCL energy working group provides six case studies that address questions about the “Conflict of Greens” across the Pacific Rim including South Korea, Taiwan, and the United States (California, Hawaii, and Massachusetts). The literature review highlights the emerging ecological, social, and economic aspects of conflicts over siting renewables on the landscape. Using case studies, we examine the trial and errors in least-conflict spatial planning, data collection and analysis, public participation in decision-making, mitigation, social planning for energy transitions, and multi-scalar approaches. Lastly, we recommend interdisciplinary policy, planning, and design actions for sustainable energy landscapes across the Pacific Rim and beyond.

green versus green, renewable energy↗

Energy Snapshot - St. Lucia

This profile provides a snapshot of the electricity capacity and generation profile of Saint Lucia, one of six Caribbean countries that make up the Windward Islands - the southern arc of the Lesser Antilles chain - at the eastern end of the Caribbean Sea.

44 EE - Strategic Programs, Energy Transition Init↗

Hybrid solar system

A hybrid solar system including a hybrid solar collector using non-imaging optics and photovoltaic components and a heat transfer and storage system in thermal communication with the hybrid solar collector, the heat transfer and storage system using particle laden gas as thermal media to simultaneously generate and store electricity and high temperature dispatchable heat.

14 SOLAR ENERGY↗

Method and system for arbitrary optical pulse generation

A system, method, and apparatus for continuous seed laser pulses supplied to a CW pumped pre-amplifier and/or power-amplifier chain comprises an optical modulator configured to impress pulse signals on an optical signal, a waveform generator configured to establish a structure of the optical signal, and a keep-alive circuit that generates a continuous electrical pulse pattern provided to the optical modulator, wherein the system provides a continuous seed laser pulse structure.

Johnson, David↗

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Low-frequency atomic electrometry

In a method of atomic electrometry, EIT spectroscopy is performed on host atoms of an alkali metal in a vapor cell. The EIT spectroscopy indicates a resonant energy of a probed Rydberg state of the host atoms. The vapor cell is exposed to an ambient electric field. A shift in the resonant energy as indicated by the EIT spectroscopy is observed and interpreted as a measurement of the ambient field. During the measurement of the ambient field, a bias electric field is generated inside the vapor cell by shining light into the vapor cell from a light source situated outside of the cell. The bias field is useful for increasing the sensitivity of the measurement.

Jau, Yuan-Yu↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

The role of nuclear in China’s energy future: insights from integrated assessment

China, the world’s largest electricity consumer, has strong motivations to deploy nuclear power due to increasing electricity demand and environmental concerns. However, there are social, institutional, and technical barriers to future nuclear expansion. This paper provides an updated assessment of nuclear energy potential in China with analyses at both national and provincial levels and compares results with studies previously conducted. Using an integrated assessment model, this paper considers the interactions among different socioeconomic development pathways, technology options, climate policies, and social/political concerns on inland siting. Among all factors explored, climate policies have the most significant impact on accelerating the deployment of nuclear technologies. Inland siting of nuclear power plants increases total capacity, but the impact is limited without climate policy. The amount of annual nuclear generation across scenarios and studies is unlikely to rise above 11% by 2030 and 30% by 2050 of total Chinese electricity generation. A dramatic increase in total Chinese nuclear energy generating capacity – around 3900 TWh of nuclear generation by 2050 – is only possible in scenarios where China sees electricity demand increase substantially, sticks to and tightens its current Paris Accord commitments, achieves low costs of nuclear technologies, and allows inland siting of nuclear power plants.

China, integrated assesment, Nuclear Power Plants↗

Comparison of Long-Term Bioenergy with Carbon Capture and Storage to Reference Power Generation Technologies Using CO2 Avoidance Cost in the U.S.

Bioenergy with carbon capture and storage (BECCS) can sequester atmospheric CO2, while producing electricity. The CO2 avoidance cost (CAC) is used to calculate the marginal cost of avoided CO2 emissions for BECCS as compared to other established energy technologies. A comparative analysis using four different reference-case power plants for CAC calculations is performed here to evaluate the CO2 avoidance cost of BECCS implementation. Results from this work demonstrate that BECCS can generate electricity at costs competitive with other neutral emissions technologies, while simultaneously removing CO2 from the atmosphere. Approximately 73% of current coal power plants are approaching retirement by the year 2035 in the U.S. After considering CO2 sequestered from the atmosphere and coal power plant CO2 emissions displaced by BECCS, CO2 emissions can be reduced by 1.4 billion tonnes per year in the U.S. alone at a cost of $88 to $116 per tonne of CO2 removed from the atmosphere, for 10% to 90% of available biomass used, respectively. CAC calculations in this paper indicate that BECCS can help the U.S. and other countries transition to a decarbonized electricity grid, as simulations presented in this paper predict that BECCS power plants operate at lower CACs than coal plants with CCS.

25 ENERGY STORAGE↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Climate Influences on Capacity Expansion Planning with Application to the Western U.S

Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.

13 HYDRO ENERGY↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Technology in Focus: Power-to-X

Power-to-X is the process that converts electricity into energy carriers that can be used in industries and applications not connected to the electricity grid. By creating a product with direct process connected generation, contracted generation, or grid-delivered electricity that is in excess of current demand, production of electricity can be managed to time arbitrage energy and mitigate generation curtailment or inefficient operational reductions. In addition, creating a product potentially develops a secondary revenue stream that aids economics of the facility. This document is a high-level factsheet that provides an overview of what Power-to-X is and what it means.

24 POWER TRANSMISSION AND DISTRIBUTION↗