Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Deep-Learning based Reconstruction of the Shower Maximum $X_{\mathrm{max}}$ using the Water-Cherenkov Detectors of the Pierre Auger Observatory

The atmospheric depth of the air shower maximum X max is an observable commonly used for the determination of the nuclear mass composition of ultra-high energy cosmic rays. Direct measurements of X max are performed using observations of the longitudinal shower development with fluorescence telescopes. At the same time, several methods have been proposed for an indirect estimation of X max from the characteristics of the shower particles registered with surface detector arrays. In this paper, we present a deep neural network (DNN) for the estimation of X max . The reconstruction relies on the signals induced by shower particles in the ground based water-Cherenkov detectors of the Pierre Auger Observatory. The network architecture features recurrent long short-term memory layers to process the temporal structure of signals and hexagonal convolutions to exploit the symmetry of the surface detector array. We evaluate the performance of the network using air showers simulated with three different hadronic interaction models. Thereafter, we account for long-term detector effects and calibrate the reconstructed X max using fluorescence measurements. Finally, we show that the event-by-event resolution in the reconstruction of the shower maximum improves with increasing shower energy and reaches less than 25 g/cm 2 at energies above 2 × 10 19 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating image coaddition with the Nancy Grace Roman Space Telescope – I. Simulation methodology and general results

The upcoming Nancy Grace Roman Space Telescope will carry out a wide-area survey in the near-infrared. A key science objective is the measurement of cosmic structure via weak gravitational lensing. Roman data will be undersampled, which introduces new challenges in the measurement of source galaxy shapes; a potential solution is to use linear algebra-based coaddition techniques such as imcom that combine multiple undersampled images to produce a single oversampled output mosaic with a desired ‘target’ point spread function (PSF). We present here an initial application of imcom to 0.64 square degrees of simulated Roman data, based on the Roman branch of the Legacy Survey of Space and Time (LSST) Dark Energy Science Collaboration (DESC) Data Challenge 2 (DC2) simulation. We show that imcom runs successfully on simulated data that includes features such as plate scale distortions, chip gaps, detector defects, and cosmic ray masks. We simultaneously propagate grids of injected sources and simulated noise fields as well as the full simulation. We quantify the residual deviations of the PSF from the target (the ‘leakage’), as well as noise properties of the output images; we discuss how the overall tiling pattern as well as Moiré patterns appear in the final leakage and noise maps. We include appendices on interpolation algorithms and the interaction of undersampling with image processing operations that may be of broader applicability. The companion paper (‘Paper II’) explores the implications for weak lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

The Astro-E/XRS Calibration Program and Results

XRS is the microcalorimeter X-ray detector aboard the US-Japanese ASTRO-E observatory, which is scheduled to be launched in early 2000. XRS is a high resolution spectrometer- with less than 9 eV resolution at 3 keV and better than 14 eV resolution over its bandpass ranging from about 0.3 keV to 15 keV. Here we present the results of our first calibration of the XRS instrument. We describe the methods used to extract detailed information about the detection efficiency and spectral redistribution of the instrument. We also present comparisons of simulations and real data to test our detector models.

Gendreau, Keith C.↗

The Astro-E/XRS Calibration Program and Results

XRS is the microcalorimeter X-ray detector aboard the US-Japanese ASTRO-E observatory, which is scheduled to be launched in early 2000. XRS is a high resolution spectrometer- with less than 9 eV resolution at 3 keV and better than 14 eV resolution over its bandpass ranging from about 0.3 keV to 15 keV. Here we present the results of our first calibration of the XRS instrument. We describe the methods used to extract detailed information about the detection efficiency and spectral redistribution of the instrument. We also present comparison of simulations and read data to test our detector models.

Gendreau, Keith C.↗

The Astro -E/XRS Calibration Program and Results

XRS is the microcalorimeter X-ray detector aboard the US-Japanese ASTRO-E observatory, which is scheduled to be launched in early 2000. XRS is a high resolution spectrometer- with less than 9 eV resolution at 3 keV and better than 14 eV resolution over its bandpass ranging from about 0.3 keV to 15 keV. Here we present the results of our first calibration of the XRS instrument. We describe the methods used to extract detailed information about the detection efficiency and spectral redistribution of the instrument. We also present comparisons of simulations and real data to test our detector models

Gendreau, Keith C.↗

Fast time variations of supernova neutrino fluxes and their detectability

In the delayed explosion scenario of core-collapse supernovae, the accretion phase shows pronounced convective overturns and a low-multipole hydrodynamic instability, the standing accretion shock instability. These effects imprint detectable fast time variations on the emerging neutrino flux. Among existing detectors, IceCube is best suited to this task, providing an event rate of {approx}1000 ms{sup -1} during the accretion phase for a fiducial SN distance of 10 kpc, comparable to what could be achieved with a megaton water Cherenkov detector. If the standing accretion shock instability activity lasts for several hundred ms, a Fourier component with an amplitude of 1% of the average signal clearly sticks out from the shot noise. We analyze in detail the output of axially symmetric hydrodynamical simulations that predict much larger amplitudes up to frequencies of a few hundred Hz. If these models are roughly representative for realistic SNe, fast time variations of the neutrino signal are easily detectable in IceCube or future megaton-class instruments. We also discuss the information that could be deduced from such a measurement about the physics in the SN core and the explosion mechanism of the SN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyrotechnic Simulator/Stray-Voltage Detector

The concept for a dual test item has been developed for use in simulating live initiators/detonators during ground testing to verify the proper operation of the safing and firing circuitry for ground and flight systems ordnance as well as continuous monitoring for any stray voltages. Previous ordnance simulators have consisted of fuses, flash bulbs, inert devices with bridge wires, and actual live ordnance items mounted in test chambers. Stray voltage detectors have included devices connected to the firing circuits for continuous monitoring and a final no-voltage test just prior to ordnance connection. The purpose of this combined ordnance simulation and stray-voltage detection is to provide an improved and comprehensive method to ensure the ordnance circuitry is verified safe and operational.

Greenfield, Terry↗

DRiFT - Release 1.0.0 Organic Scintillators

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that postprocesses output from the extensively validated radiation transport code, MCNP [1], and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. Although DRiFT development has included scintillator [2], gas [3], and semiconductor features [4], the focus of this release is on organic scintillator and associated capabilities. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts [5, 6]. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

61 RADIATION PROTECTION AND DOSIMETRY↗

DRiFT - Release 1.1.1: Organic Scintillators

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that postprocesses output from the extensively validated radiation transport code, MCNP, and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. Although DRiFT development has included scintillator, gas, and semiconductor features, the focus of this release is on organic scintillator and associated capabilities. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic Efficiency Calibration Considering Geometric Factors in Gamma-ray Computed Tomography for Radioactive Waste Assay

In radioactive waste assay with gamma-ray computed tomography, calibration for intrinsic efficiency of the system is important to the reconstruction of radioactivity distribution. Due to the geometric characteristics of the system, the non-uniformity of intrinsic efficiency for gamma-rays with different incident positions and directions are often un-negligible. Intrinsic efficiency curves versus geometric parameters of incident gamma-ray are obtained by Monte-Carlo simulation, and two intrinsic efficiency models are suggested to characterize the intrinsic efficiency determined by relative source-detector position and system geometry in the system matrix. Monte-Carlo simulation is performed to compare the different intrinsic efficiency models. Better reconstruction results of radioactivity distribution are achieved by both suggested models than by the uniform intrinsic efficiency model. And compared to model based on detector position, model based on point response increases reconstruction accuracy as well as complexity and time of calculation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SUPERNOVA NEUTRINO LIGHT CURVES AND SPECTRA FOR VARIOUS PROGENITOR STARS: FROM CORE COLLAPSE TO PROTO-NEUTRON STAR COOLING

We present a new series of supernova neutrino light curves and spectra calculated by numerical simulations for a variety of progenitor stellar masses (13-50 M {sub Sun }) and metallicities (Z = 0.02 and 0.004), which would be useful for a broad range of supernova neutrino studies, e.g., simulations of future neutrino burst detection by underground detectors or theoretical predictions for the relic supernova neutrino background. To follow the evolution from the onset of collapse to 20 s after the core bounce, we combine the results of neutrino-radiation hydrodynamic simulations for the early phase and quasi-static evolutionary calculations of neutrino diffusion for the late phase, with different values of shock revival time as a parameter that should depend on the still unknown explosion mechanism. We describe the calculation methods and basic results, including the dependence on progenitor models and the shock revival time. The neutrino data are publicly available electronically.

79 ASTRONOMY AND ASTROPHYSICS↗

Engineering challenges for detectors at the ILC

Over the last years two proposals for experiments at the ILC have been developed, ILD and SID. Extensive R&D has been carried out around the world to develop the needed technologies. Furthermore a first round of engineering studies was made as part of the ILC TDR to understand the integration of these different sub-systems into coherent and integrated detector concepts. Among the key challenges for the sub detectors are the extreme low mass/low power requirements or the extreme channel densities needed in particle flow based detectors. Throughout these studies special care was taken to ensure that the engineering models and the simulation models, used in studies of the physics capabilities of the detectors, stay synchronized. In the near future, the models will need to be evolved to take the special requirements of the potential ILC site in Japan into account. Furthermore, the state of the integration of the detectors, and the future directions, will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Noise Amplifiers and Superconducting Flex Circuits for Frequency Domain Multiplexed Readout of Detector Arrays

The next-generation ground-based cosmic microwave background (CMB) experimental program aims to provide definitive measurements of the early universe using telescopes configured with large focal plane arrays requiring ~100,000 detectors and associated readout amplifiers and interconnecting components that are currently unavailable commercially. We describe research to demonstrate the feasibility of developing low-noise cryogenic amplifiers based on series SQUID arrays that are suitable for frequency domain multiplexed readout of large numbers of CMB detectors, and the feasibility of developing robust superconducting flex cables that will simplify cryogenic systems integration for large CMB instruments. Two iterations of prototype series SQUID array amplifier designs were completed. The designs were optimized using modeling and simulation tools to meet the requirements for CMB detector readouts. Two fabrication runs were completed, and a large number of devices from each design iteration were tested and characterized at 4 K. We also completed the development of processes for the fabrication of prototype superconducting flex cables on 4" wafers. Samples were tested for strength and robustness, and to determine the critical current at 4 K as a function of trace width. The new generation of series SQUID array amplifier designs exhibit excellent performance characteristics – very smooth output characteristics that simplify tuning and operation, low input inductance, low current noise referred to the input, and low power dissipation that for the first time will enable these devices to be operated at the focal plane array stage of CMB instruments. The processes developed in Phase I to produce superconducting flex cables were used to complete the fabrication of a full wafer with several test and sample flex circuits. The 6-micron thick flex material is very strong with a breaking strength of several pounds for a 20-mm wide strip. Critical current density was reasonable and scaled with trace width as expected.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of Nuclear Data Measurement and Analysis at RPI [Slides]

This presentation discusses the experimental, simulation, and nuclear data methods that were validated for the RPI γ-Multiplicity Detector. When the neutron capture γ-cascade data is well-known, the γ-emission spectra can be accurately calculated using the modified simulation tools. The RPI γ-Multiplicity Detector system is now ready for analysis and recommendations for isotopes with deficiencies in γ-ray data. The presentation also discusses future work which includes developing a method for analyzing and adjusting nuclear data for 59 Co, 55 Mn and other measured isotopes including 181 Ta. Additionally, future work includes comparing experimental γ-emission spectra with MCNP-6.2/DICEBOX simulations for 238 U and 235 U. In summation, new capture and transmission measurements for 54 Fe will help improve resonance parameter evaluation. Neutron capture gamma cascade spectra and yields were measured in the resolved resonance region and compared to evaluations. In addition, the pulsed neutron die-away method was developed as a tool to provide data for validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test results and in-orbit operation of the Infrared Astronomical Satellite circumvention circuit

The IRAS circumvention circuit (CC) eliminates the unwanted charged-particle pulses from the IR signal. The operation of the CC along with preflight and in-orbit testing is described. Ground testing of the brassboard circuit using a simulated preamplifier output showed that the CC would perform the circumvention function as designed. When all flight detectors and preamplifiers became available, the CC was tested using a gamma source to simulate charged-particle sources; with the low energy deposited in the detectors (20 keV average) the noise was reduced by up to 5 times with the CC turned on. In-orbit results show that the CC decreases the unwanted charged-particle background noise by up to two orders of magnitude. The difference in the results with the CC on and off is so great that the science team has recommended that no data be taken with the CC off.

Long, E. C.↗

Simulations for the global quantum efficiency of MicroBooNE optical units

The MicroBooNE detector uses scintillation light from particle interactions in liquid argon as a data acquisition trigger. This scintillation light has wavelengths in the vacuum ultra violet (VUV) range, and must be converted into visible light to be detected by photomultiplier tubes (PMTs). To convert the light, MicroBooNE uses wavelength shifting plates coated with Tetraphenyl butadiene (TPB) placed in front of its PMTs. While basic tuning of this plate-PMT system is sufficient for triggering, precise calibration of the system makes additional calorimetry possible. This note will outline how a photon simulation which accounts for the geometry and optical details of the MicroBooNE detector can accompany a measurement of observed photoelectrons in a plate-PMT test stand, and how the results may be used to determine a "global quantum efficiency" for the plate-PMT system. This global quantum efficiency is one required ingredient for improving the capabilities of the light collection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytic Perturbation Method for Estimating Ground Flash Fraction from Satellite Lightning Observations

An analytic perturbation method is introduced for estimating the lightning ground flash fraction in a set of N lightning flashes observed by a satellite lightning mapper. The value of N is large, typically in the thousands, and the observations consist of the maximum optical group area produced by each flash. The method is tested using simulated observations that are based on Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) data. National Lightning Detection NetworkTM (NLDN) data is used to determine the flash‐type (ground or cloud) of the satellite-observed flashes, and provides the ground flash fraction truth for the simulation runs. It is found that the mean ground flash fraction retrieval errors are below 0.04 across the full range 0‐1 under certain simulation conditions. In general, it is demonstrated that the retrieval errors depend on many factors (i.e., the number, N, of satellite observations, the magnitude of random and systematic measurement errors, and the number of samples used to form certain climate distributions employed in the model).

Koshak, William↗