Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data processing and standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Distributed Automatic Differentiation for Ptychography

Synchrotron radiation light source facilities are leading the way to ultrahigh resolution X-ray imaging. High resolution imaging is essential to understanding the fundamental structure and interaction of materials at the smallest length scale possible. Diffraction based methods achieve nanoscale imaging by replacing traditional objective lenses by pixelated area detectors and computational image reconstruction. Among these methods, ptychography is quickly becoming the standard for sub-30 nanometer imaging of extended samples, but at the expense of increasingly high data rates and volumes. This paper presents a new distributed algorithm for solving the ptychographic image reconstruction problem based on automatic differentiation. Input datasets are subdivided between multiple graphics processing units (GPUs); each subset of the problem is then solved either entirely independent of other subsets (asynchronously) or through sharing gradient information with other GPUs (synchronously). The algorithm was evaluated on simulated and real data acquired at the Advanced Photon Source, scaling up to 192 GPUs. The synchronous variant of our method outperformed an existing multi-GPU implementation in terms of accuracy while running at a comparable execution time.

distributed algorithms↗

Was there an early reionization component in our universe?

A deep understanding of the epoch of reionization is still missing in our knowledge of the universe. While future probes will allow us to test the precise evolution of the free electron fraction from redshifts between z 6 and 0z 2, at present one could ask what kind of reionization processes are allowed by present cosmic microwave background temperature and polarization measurements. An early contribution to reionization could imply a departure from the standard picture where star formation determines the reionization onset. By considering a broad class of possible reionization parameterizations, we find that current data do not require an early reionization component in our universe and that only one marginal class of models, based on a particular realization of reionization, may point to that. In addition, the frequentist Akaike information criterion (AIC) provides strong evidence against alternative reionization histories, favoring the most simple reionization scenario, which describes reionization by means of only one (constant) reionization optical depth τ.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the {beta}-{nu} correlation of {sup 21}Na using shakeoff electrons

The {beta}-{nu} correlation coefficient, a{sub {beta}}{sub {nu}}, is measured in {sup 21}Na by detecting the time of flight of the recoil nucleus detected in coincidence with the atomic electrons shaken off in {beta} decay. The sample of {sup 21}Na is confined in a magneto-optic trap. High detection efficiency allows low trap density, which suppresses the photoassociation of molecular sodium, which can cause a large systematic error. Suppressing the fraction of trapped atoms in the excited state by using a dark trap also reduces the photoassociation process, and data taken with this technique are consistent. The main remaining systematic uncertainties come from the measurement of the position and size of the atom trap and the subtraction of background. We find a{sub {beta}}{sub {nu}}=0.5502(60), in agreement with the Standard Model prediction of a{sub {beta}}{sub {nu}}=0.553(2), and disagreeing with a previous measurement, which was susceptible to an error introduced by the presence of molecular sodium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for a scalar or pseudoscalar dilepton resonance produced in association with a massive vector boson or top quark-antiquark pair in multilepton events at s = 13 TeV

A search for beyond the standard model spin-0 bosons, ϕ , that decay into pairs of electrons, muons, or tau leptons is presented. The search targets the associated production of such bosons with a W or Z gauge boson, or a top quark-antiquark pair, and uses events with three or four charged leptons, including hadronically decaying tau leptons. The proton-proton collision data set used in the analysis was collected at the LHC from 2016 to 2018 at a center-of-mass energy of 13 TeV, and corresponds to an integrated luminosity of 138 fb - 1 . The observations are consistent with the predictions from standard model processes. Upper limits are placed on the product of cross sections and branching fractions of such new particles over the mass range of 15 to 350 GeV with scalar, pseudoscalar, or Higgs-boson-like couplings, as well as on the product of coupling parameters and branching fractions. Several model-dependent exclusion limits are also presented. For a Higgs-boson-like ϕ model, limits are set on the mixing angle of the Higgs boson with the ϕ boson. For the associated production of a ϕ boson with a top quark-antiquark pair, limits are set on the coupling to top quarks. Finally, limits are set for the first time on a fermiophilic dilaton-like model with scalar couplings and a fermiophilic axion-like model with pseudoscalar couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signal processing and spectral modeling for the BeEST experiment

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.

6 ≤ A ≤ 19↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

A search for new phenomena in pp collisions at $\sqrt{s} = 13\,\text {TeV} $ in final states with missing transverse momentum and at least one jet using the $\alpha _{\mathrm {T}}$ variable

A search for new phenomena is performed in final states containing one or more jets and an imbalance in transverse momentum in pp collisions at a centre-of-mass energy of 13 $\,\text {TeV}$ . The analysed data sample, recorded with the CMS detector at the CERN LHC, corresponds to an integrated luminosity of 2.3 $\,\text {fb}^{-1}$ . Several kinematic variables are employed to suppress the dominant background, multijet production, as well as to discriminate between other standard model and new physics processes. The search provides sensitivity to a broad range of new-physics models that yield a stable weakly interacting massive particle. The number of observed candidate events is found to agree with the expected contributions from standard model processes, and the result is interpreted in the mass parameter space of fourteen simplified supersymmetric models that assume the pair production of gluinos or squarks and a range of decay modes. For models that assume gluino pair production, masses up to 1575 and 975 $\,\text {GeV}$ are excluded for gluinos and neutralinos, respectively. For models involving the pair production of top squarks and compressed mass spectra, top squark masses up to 400 $\,\text {GeV}$ are excluded.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An alkali-free method to manufacture ramie fiber

Ramie is one of the most significant fiber resources and it needs the degumming process to produce fibers. The traditional manufacturing process of ramie fibers requires a large amount of alkali, which causes serious environmental issues. This paper presents a novel path to manufacture ramie fibers without alkali. In this study, ramie bast was pretreated by steam explosion and then treated with deep eutectic solvent. The properties of ramie fibers prepared by the novel alkali-free method, including physical properties, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and X-ray diffraction (XRD), were compared with that produced by the traditional alkali process. Results showed that the fiber qualities, including residual gum content (4.68%), average fiber fineness (1419.99 N m ) and breaking tenacity (5.98 cN/dtex), were comparable with the traditional alkali process, which all meet the requirement of the relevant Chinese National Standards. The FTIR, SEM and XRD results all confirmed the degumming ability of the novel method to manufacture ramie fibers. Furthermore, the novel method was proved to be eco-friendly. Taken together, these data indicate that the novel alkali-free method is green and effective in manufacturing ramie fibers.

42 ENGINEERING↗

Improving Transparency in the Reporting of Safeguards Implementation: FY11 Update

In 2008, the Standing Advisory Group on Safeguards Implementation (SAGSI) indicated that the International Atomic Energy Agency's (IAEA) Safeguards Implementation Report (SIR) has not kept pace with the evolution of safeguards and provided the IAEA with a set of recommendations for improvement. The SIR is the primary mechanism for providing an overview of safeguards implementation in a given year and reporting on the annual safeguards findings and conclusions drawn by the Secretariat. As the IAEA transitions to State-level safeguards approaches, SIR reporting must adapt to reflect these evolutionary changes. This evolved report will better reflect the IAEA's transition to a more qualitative and information-driven approach, based upon State-as-a-whole considerations. This paper applies SAGSI's recommendations to the development of multiple models for an evolved SIR and finds that an SIR repurposed as a 'safeguards portal' could significantly enhance information delivery, clarity, and transparency. In addition, this paper finds that the 'portal concept' also appears to have value as a standardized information presentation and analysis platform for use by Country Officers, for continuity of knowledge purposes, and the IAEA Secretariat in the safeguards conclusion process. Accompanying this paper is a fully functional prototype of the 'portal' concept, built using commercial software and IAEA Annual Report data and available for viewing at http://safeguardsportal.pnnl.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Addendum to the Closure Report for Corrective Action Unit 271: Areas 25, 26, and 27 Septic Systems Nevada Test Site, Nevada, Revision 0 with ROTC 1

This document constitutes an addendum to the August 2004, Closure Report for Corrective Action Unit 271, Areas 25, 26, and 27 Septic Systems as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of: • This cover page that refers the reader to the UR Modification document for additional information • The cover and signature pages of the UR Modification document • The NDEP approval letter • The corresponding section of the UR Modification document This addendum provides the documentation justifying the modification of the UR for CAS 27-05-02, Leachfield. This UR was established as part of a Federal Facility Agreement and Consent Order (FFACO) corrective action and is based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since this UR was established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, this UR was re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This re-evaluation consisted of comparing the original data (used to define the need for the UR) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to modify the UR to an administrative UR. Administrative URs differ from standard URs in that they do not require onsite postings (i.e., signs) or other physical barriers (e.g., fencing, monuments), and they do not require periodic inspections (see Section 6.2 of the Industrial Sites Project Establishment of Final Action Levels [NNSA/NSO, 2006c]). This Administrative UR was based on an “Occasional Use Area” future land use scenario that was used to calculate the FAL. The administrative UR will protect workers from an exposure exceeding that used in the calculation of the FAL (i.e., 400 total work hours). Any proposed activity within this use restricted area that would potentially cause an exposure exceeding this exposure limit would require approval from the Nevada Division of Environmental Protection (NDEP). Requirements for inspecting and maintaining postings at this UR will be canceled, and the postings and signage at this site will be removed. Fencing and posting may be present at this site that are unrelated to the FFACO UR such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at this site.

01 COAL, LIGNITE, AND PEAT↗

Search for $B_s \to \mu^+\mu^-$ and $B_d \to \mu^+\mu^-$ Decays with CDF II

A search has been performed for B{sub s}{sup 0} {yields} {mu}{sup +}{mu}{sup -} and B{sup 0} {yields} {mu}{sup +}{mu}{sup -} decays using 7 fb{sup -1} of integrated luminosity collected by the CDF II detector at the Fermilab Tevatron collider. The observed number of B{sup 0} candidates is consistent with background-only expectations and yields an upper limit on the branching fraction of {Beta}(B{sup 0} {yields} {mu}{sup +}{mu}{sup -}) < 6.0 x 10{sup -9} at 95% confidence level. We observe an excess of B{sub s}{sup 0} candidates. The probability that the background processes alone could produce such an excess or larger is 0.27%. The probability that the combination of background and the expected standard model rate of B{sub s}{sup 0} {yields} {mu}{sup +}{mu}{sup -} could produce such an excess or larger is 1.9%. These data are used to determine {Beta}(B{sub s}{sup 0} {yields} {mu}{sup +}{mu}{sup -}) = (1.8{sub -0.9}{sup +1.1}) x 10{sup -8} and provide an upper limit of {Beta}(B{sub s}{sup 0} {yields} {mu}{sup +}{mu}{sup -}) < 4.0 x 10{sup -8} at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the Transparency of IAEA Safeguards Reporting

In 2008, the Standing Advisory Group on Safeguards Implementation (SAGSI) indicated that the International Atomic Energy Agency's (IAEA) Safeguards Implementation Report (SIR) has not kept pace with the evolution of safeguards and provided the IAEA with a set of recommendations for improvement. The SIR is the primary mechanism for providing an overview of safeguards implementation in a given year and reporting on the annual safeguards findings and conclusions drawn by the Secretariat. As the IAEA transitions to State-level safeguards approaches, SIR reporting must adapt to reflect these evolutionary changes. This evolved report will better reflect the IAEA's transition to a more qualitative and information-driven approach, based upon State-as-a-whole considerations. This paper applies SAGSI's recommendations to the development of multiple models for an evolved SIR and finds that an SIR repurposed as a 'safeguards portal' could significantly enhance information delivery, clarity, and transparency. In addition, this paper finds that the 'portal concept' also appears to have value as a standardized information presentation and analysis platform for use by Country Officers, for continuity of knowledge purposes, and the IAEA Secretariat in the safeguards conclusion process. Accompanying this paper is a fully functional prototype of the 'portal' concept, built using commercial software and IAEA Annual Report data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AI-Driven Crack Detection for Remanufacturing Cylinder Heads Using Deep Learning and Engineering-Informed Data Augmentation

Detecting cracks in cylinder heads traditionally relies on manual inspection, which is time-consuming and susceptible to human error. As an alternative, automated object detection utilizing computer vision and machine learning models has been explored. However, these methods often face challenges due to a lack of sufficiently annotated training data, limited image diversity, and the inherently small size of cracks. Addressing these constraints, this paper introduces a novel automated crack-detection method that enhances data availability through a synthetic data generation technique. Unlike general data augmentation practices, our method involves copying cracks from one location to another, guided by both random and informed engineering decisions about likely crack formations due to cyclic thermomechanical loads. The innovative aspect of our approach lies in the integration of domain-specific engineering knowledge into the synthetic generation process, which substantially improves detection accuracy. We evaluate our method’s effectiveness using two metrics: the F2 score, which emphasizes recall to prioritize detecting all potential cracks, and mean average precision (MAP), a standard measure in object detection. Experimental results demonstrate that, without engineering insights, our method increases the F2 score from 0.40 to 0.65, while maintaining a stable MAP. Incorporating detailed engineering knowledge further enhances the F2 score to 0.70 and improves MAP to 0.57, representing increases of 63% and 43%, respectively. These results confirm that our approach not only mitigates the limitations of traditional data augmentation but also significantly advances the reliability and precision of crack detection in industrial settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recognizability of Demographically Altered Computerized Facial Approximations in an Automated Facial Recognition Context for Potential Application in Unidentified Persons Data Repositories

This study examined the recognizability of demographically altered facial approximations for potential utility in unidentified persons tracking systems. Five computer-generated approximations were generated for each of 26 African male participants using the following demographic parameters: (i) African male (true demographics), (ii) African female, (iii) Caucasian male, (iv) Asian male, and (v) Hispanic male. Overall, 62% of the true demographic facial approximations for the 26 African male participants examined were matched to a corresponding life photo within the top 50 images of a candidate list generated from an automated blind search of an optimally standardized gallery of 6159 photographs. When the African male participants were processed as African females, the identification rate was 50%. In contrast, less congruent identification rates were observed when the African male participants were processed as Caucasian (42%), Asian (35%), and Hispanic (27%) males. The observed results suggest that approximations generated using the opposite sex may be operationally informative if sex is unknown. The performance of approximations generated using alternative ancestry assignments, however, was less congruent with the performance of the true demographic approximation (African male) and may not yield as operationally constructive data as sex-altered approximations.

59 BASIC BIOLOGICAL SCIENCES↗

NREL Pyrheliometer Comparisons: September 24 - October 5, 2018 (NPC-2018)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ASR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an International Pyrheliometer Comparison (IPC) for transferring the WRR to participating radiometers quinquennialy by invitation. NREL has represented the U.S. Department of Energy (DOE) in each IPC since 1980. As a result, NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR. NPC-2018 was September 24 through October 5, 2018. Participants operated 43 ACRs to simultaneously measure clear-sky direct normal solar irradiance during this period. The Transfer Standard Group (TSG) of reference radiometers for NPC-2018 consisted of four NREL radiometers with direct traceability to the WRR, having participated in the Twelfth International Pyrheliometer Comparisons (IPC-XII) in the fall of 2015. As a result of NPC-2018, each participating absolute cavity radiometer was assigned a new WRR-TF, computed as the reference irradiance determined by the TSG divided by the observed irradiance from the participating radiometer. The performance of the TSG during NPC-2018 was consistent with previous comparisons, including IPC-XII. The measurement performance of the TSG allowed the transfer of the WRR to each participating radiometer with an estimated uncertainty of plus/minus 0.36% with respect to the International System of Units.

14 SOLAR ENERGY↗

Model-Form Epistemic Uncertainty Quantification for Modeling with Differential Equations: Application to Epidemiology

Modeling real-world phenomena to any degree of accuracy is a challenge that the scientific research community has navigated since its foundation. Lack of information and limited computational and observational resources necessitate modeling assumptions which, when invalid, lead to model-form error (MFE). The work reported herein explored a novel method to represent model-form uncertainty (MFU) that combines Bayesian statistics with the emerging field of universal differential equations (UDEs). The fundamental principle behind UDEs is simple: use known equational forms that govern a dynamical system when you have them; then incorporate data-driven approaches – in this case neural networks (NNs) – embedded within the governing equations to learn the interacting terms that were underrepresented. Utilizing epidemiology as our motivating exemplar, this report will highlight the challenges of modeling novel infectious diseases while introducing ways to incorporate NN approximations to MFE. Prior to embarking on a Bayesian calibration, we first explored methods to augment the standard (non-Bayesian) UDE training procedure to account for uncertainty and increase robustness of training. In addition, it is often the case that uncertainty in observations is significant; this may be due to randomness or lack of precision in the measurement process. This uncertainty typically manifests as “noisy” observations which deviate from a true underlying signal. To account for such variability, the NN approximation to MFE is endowed with a probabilistic representation and is updated using available observational data in a Bayesian framework. By representing the MFU explicitly and deploying an embedded, data-driven model, this approach enables an agile, expressive, and interpretable method for representing MFU. In this report we will provide evidence that Bayesian UDEs show promise as a novel framework for any science-based, data-driven MFU representation; while emphasizing that significant advances must be made in the calibration of Bayesian NNs to ensure a robust calibration procedure.

97 MATHEMATICS AND COMPUTING↗