Non-linear Alfvén wave interaction leading to resonant excitation of an acoustic mode in the laboratory

The nonlinear three-wave interaction process at the heart of the parametric decay process is studied by launching counter-propagating Alfvén waves from antennas placed at either end of the Large Plasma Device [W. Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)]. A resonance in the beat wave response produced by the two launched Alfvén waves is observed and is identified as a damped ion acoustic mode based on the measured dispersion relation. Other properties of the interaction including the spatial profile of the beat mode and response amplitude are also consistent with theoretical predictions for a three-wave interaction driven by a nonlinear ponderomotive force. A simple damped, driven oscillator model making use of the MHD equations well-predicts most of the observations, but the width of the resonance curve is still under investigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray and optical observations of X-ray-selected BL Laceratae objects

Results from several X-ray and optical observations of five X-ray-selected BL Lacertae objects are reported. X-ray light curves covering periods of up to 6 yr reveal that the X-ray flux from these objects does not show large-amplitude trends over this time scale. Variations of up to 2 mag have been observed in the optical. The soft X-ray spectra of three objects have been measured with the Exosat Medium Energy detectors. Energy spectral indices range between one and two. In one case (1E 1415.6 + 2557), evidence for photoelectric absorption in excess of that due to the local interstellar medium has been found. A new optical flare from 1E 1402.3 + 0416, with rise and decay time of order of a few weeks, has been detected.

Giommi, P.↗

Trapped Particle Effects in the Parametric Instability of Near-Acoustic Plasma Waves

Quantitative experiments on the parametric decay instability of near-acoustic plasma waves provide strong evidence that trapped particles reduce the instability threshold below fluid models. At low temperatures, the broad characteristics of the parametric instability are determined by the frequency detuning of the pump and daughter wave, and the wave-wave coupling strength, surprisingly consistent with cold fluid, three-wave theories. Furthermore, at higher temperatures, trapped particle effects dominate, and the pump wave becomes unstable at half the threshold pump wave amplitude with similar exponential growth rates as for a cold plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the CP-violating phase ϕ s in B$_s^0$→J/ψϕ decays in ATLAS at 13 TeV

A measurement of the B$_s^0$→J/ψϕ decay parameters using 80.5 fb -1 of integrated luminosity collected with the ATLAS detector from 13 Te proton–proton collisions at the LHC is presented. The measured parameters include the CP-violating phase ϕ s , the width difference Δ Γ s between the B$_s^0$ meson mass eigenstates and the average decay width Γ s . The values measured for the physical parameters are combined with those from 19.2fb -1 of 7 and 8 Te data, leading to the following: ϕs=-0.087±0.036(stat.)±0.021(syst.)rad ΔΓ s =0.0657±0.0043(stat.)±0.0037(syst.)ps -1 Γ s =0.6703±0.0014(stat.)±0.0018(syst.)ps -1 Results for ϕ s and Δ Γ s are also presented as 68% confidence level contours in the ϕ s –Δ Γ s plane. Furthermore the transversity amplitudes and corresponding strong phases are measured. ϕ s and Δ Γ s measurements are in agreement with the Standard Model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Analytical Approach to the Design of an Automatic Discontinuous Control System

An analytical investigation was conducted concerning the design of an attitude-stabilization system for stabilizing a vehicle experiencing negligible external moments. The system studied was an automatic discontinuous control system employing a linear switching function including effects of pure time delays, rise and decay time, and neutral zone. Equations were developed which generalize the transient and limit-cycle performance of the control system. understanding of how the physical constants of the system affect its performance, the equations enable the optimization of the system with regard to most considerations that can be expressed mathematically. Design charts are presented which enable rapid calculation of the best thrust level and switching-function coefficient for minimizing power required to stabilize the vehicle within some amplitude, minimizing attitude error, and minimizing angular-velocity error after a period of operation.

Taylor, Lawrence W., Jr.↗

Gapless Higgs mode in the Fulde-Ferrell-Larkin-Ovchinnikov state of a superconductor

We report the Higgs mode associated with amplitude fluctuations of the superconducting gap in uniform superconductors is usually heavy, which makes its excitation and detection difficult. We report on the existence of a gapless Higgs mode in the Fulde-Ferrell-Larkin-Ovchinnikov states. This feature originates from the Goldstone mode associated with translation-symmetry breaking. The existence of the gapless Higgs mode is demonstrated by using both a phenomenological model and microscopic Bardeen-Cooper-Schrieffer (BCS) theory. The gapless Higgs mode can avoid the decay into other low-energy excitations, which renders it stable and detectable.

36 MATERIALS SCIENCE↗

Phenomenological study of the interplay between IR-improved DGLAP-CS theory and the precision of an NLO ME matched parton shower MC

We present a phenomenological study of the current status of the application of our approach of exact amplitude-based resummation in quantum field theory to precision QCD calculations, by realistic MC event generator methods, as needed for precision LHC physics. We discuss recent results as they relate to the interplay of the attendant IR-improved DGLAP-CS theory of one of us and the precision of exact NLO matrix-element matched parton shower MC’s in the Herwig6.5 environment as determined by comparison to recent LHC experimental observations on single heavy gauge boson production and decay. The level of agreement between the new theory and the data continues to be a reason for optimism. In the spirit of completeness, we discuss as well other approaches to the same theoretical predictions that we make here from the standpoint of physical precision with an eye toward the (sub-)1% QCD⊗EW total theoretical precision regime for LHC physics. - Highlights: • Using LHC data, we show that IR-improved DGLAP-CS kernels with exact NLO Shower/ME matching improves MC precision. • We discuss other possible approaches in comparison with ours. • We propose experimental tests to discriminate between competing approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperon Photoproduction from Polarized H and D: towards a complete N* experiment

New complete experiments in pseudoscalar meson photo-production are being pursued at several laboratories. Here the designation of complete refers to measurements of most if not all of the possible reaction observables, of which there are 16 involving spins of the beam, target and recoil baryon. Hyperon production to Λ or Σ{sup +} final states affords attractive opportunities, since their weak decays provide an efficient self-analysis of their polarization. When the beam and target are also polarized, the resulting triple polarization measurements determine the full suite of observables with a single target orientation. This has been a focus at Jefferson Lab in the recently completed g9/FROST and g14/HDice experiments now under analysis. Multipole analyses of γp->K{sup +}Λ have been carried out with a large though incomplete set of recently published polarization data, and the uniqueness of the extracted amplitudes has been studied. Experiments with realistically achievable uncertainties require a significantly greater number of spin asymmetries than the in-principle minimum needed for a mathematical solution of the amplitude.

Baryon resonances↗

Multiwavelength Observations of a Dramatic High-Energy Flare in the Blazar 3C 279

The blazar 3C 279, one of the brightest identified extragalactic objects in the gamma-ray sky, underwent a large (factor of approximately 10 in amplitude) flare in gamma-rays toward the end of a 3 week pointing by Compton Gamma Ray Observatory (CGRO), in 1996 January-February. The flare peak represents the highest gamma-ray intensity ever recorded for this object. During the high state, extremely rapid gamma-ray variability was seen, including an increase of a factor of 2.6 in approximately 8 hr, which strengthens the case for relativistic beaming. Coordinated multifrequency observations were carried out with Rossi X-Ray Timing Explorer (RXTE), Advanced Satellite for Cosmology and Astrophysics (ASCA; or, Astro-D), Roentgen Satellite (ROSAT), and International Ultraviolet Explorer (IUE) and from many ground-based observatories, covering most accessible wavelengths. The well-sampled, simultaneous RXTE light curve shows an outburst of lower amplitude (factor of approximately = 3) well correlated with the gamma-ray flare without any lag larger than the temporal resolution of approximately 1 day. The optical-UV light curves, which are not well sampled during the high-energy flare, exhibit more modest variations (factor of approximately 2) and a lower degree of correlation. The flux at millimetric wavelengths was near a historical maximum during the gamma-ray flare peak, and there is a suggestion of a correlated decay. We present simultaneous spectral energy distributions of 3C 279 prior to and near to the flare peak. The gamma-rays vary by more than the square of the observed IR-optical flux change, which poses some problems for specific blazar emission models. The synchrotron self-Compton (SSC) model would require that the largest synchrotron variability occurred in the mostly unobserved submillimeter/far-infrared region. Alternatively, a large variation in the external photon field could occur over a time-scale of a few days. This occurs naturally in the "mirror" model wherein the flaring region in the jet photoionizes nearby broad emission line clouds, which, in turn, provide soft external photons that are Comptonized to gamma-ray energies.

Wehrle, A. E.↗

Chaotic dynamics and diffusion in a piecewise linear equation

Genetic interactions are often modeled by logical networks in which time is discrete and all gene activity states update simultaneously. However, there is no synchronizing clock in organisms. An alternative model assumes that the logical network is preserved and plays a key role in driving the dynamics in piecewise nonlinear differential equations. We examine dynamics in a particular 4-dimensional equation of this class. In the equation, two of the variables form a negative feedback loop that drives a second negative feedback loop. By modifying the original equations by eliminating exponential decay, we generate a modified system that is amenable to detailed analysis. In the modified system, we can determine in detail the Poincaré (return) map on a cross section to the flow. By analyzing the eigenvalues of the map for the different trajectories, we are able to show that except for a set of measure 0, the flow must necessarily have an eigenvalue greater than 1 and hence there is sensitive dependence on initial conditions. Further, there is an irregular oscillation whose amplitude is described by a diffusive process that is well-modeled by the Irwin-Hall distribution. There is a large class of other piecewise-linear networks that might be analyzed using similar methods. The analysis gives insight into possible origins of chaotic dynamics in periodically forced dynamical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the lineshape of the χ c1 (3872) state

A study of the lineshape of the χ c1 (3872) state is made using a data sample corresponding to an integrated luminosity of 3 fb –1 collected in pp collisions at center-of-mass energies of 7 and 8 TeV with the LHCb detector. Candidate χ c1 (3872) and ψ(2S) mesons from b-hadron decays are selected in the J/ψπ + π – decay mode. Describing the lineshape with a Breit-Wigner function, the mass splitting between the χ c1 (3872) and ψ(2S) states, Δm, and the width of the χ c1 (3872) state, Γ BW , are determined to be Δm=185.598 ± 0.067 ± 0.068 MeV, Γ BW = 1.39 ± 0.24 ± 0.10 MeV, where the first uncertainty is statistical and the second systematic. Using a Flatté-inspired model, the mode and full width at half maximum of the lineshape are determined to be mode = 3871.69+0.00+0.05 – 0.04–0.13 MeV, FWHM=0.22 +0.07+0.11–0.06–0.13 MeV. An investigation of the analytic structure of the Flatté amplitude reveals a pole structure, which is compatible with a quasibound D 0 D¯ *0 state but a quasivirtual state is still allowed at the level of 2 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective conductivity of wire mesh reflectors for space deployable antenna systems

This report summarizes efforts to characterize the measurement of conductive mesh and smooth surfaces using proximity measurements for a dielectric resonator. The resonator operates in the HEM11 mode and is shown to have an evanescent field behavior in the vicinity of the sample surface, raising some question to the validity of measurements requiring near normal incidence on the material. In addition, the slow radial field decay outside of the dielectric resonator validates the sensitivity to the planar supporting structure and potential radiation effects. Though these concerns become apparent along with the sensitivity to the gap between the dielectric and the material surface, the basic concept of the material measurement using dielectric resonators has been verified for useful comparison of material surface properties. The properties, particularly loss, may be obtained by monitoring the resonant frequency along with the resonator quality factor (Q), 3 dB bandwidth, or the midband transmission amplitude. Comparison must be made to known materials to extract the desired data.

Davis, William A.↗

Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging

State-of-the art X-ray imaging cameras using silicon sensors for X-ray detection have demonstrated a frame-rate of 10 MHz and excellent performance for X-ray energies below 20 keV. We proposed a pixelated ultrafast inorganic scintillator-based front imager for GHz hard X-ray imaging. Here, the proposed imager is featured with a total absorption for hard X-ray photons, and provides sub-ns scintillation pulse width crucial for X-ray bunches of a few ns spacing foreseen at the proposed MaRIE facility. We measured temporal response of a dozen ultrafast and fast inorganic scintillators at the 10-ID-B site of the Advanced Photon Source (APS) of ANL. Crystal's response to hybrid X-ray beam of 30 keV, consisting of singlet bunches of 50 ps width and septuplet bunches of 27 ps width with 2.83 ns bunch spacing, was measured. Ultrafast inorganic scintillators, such as BaF 2 :Y and ZnO:Ga, show clearly resolved X-ray bunches for septuplets, as well as no degradation of amplitude for continuous eight septuplets, providing a proof of principle for the ultrafast inorganic scintillator-based total absorption front imager for the proposed MaRIE project.

47 OTHER INSTRUMENTATION↗

Multiwavelength Observations of a Dramatic High-Energy Flare in the Blazar 3C 279

The blazar 3C 279, one of the brightest identified extragalactic objects in the gamma-ray sky, underwent a large (factor of approx. 10 in amplitude) flare in gamma-rays toward the end of a 3 week pointing by Compton Gamma Ray Observatory (CGRO), in 1996 January-February. The flare peak represents the highest gamma-ray intensity ever recorded for this object. During the high state, extremely rapid gamma-ray variability was seen, including an increase of a factor of 2.6 in approx. 8 hrs., which strengthens the case for relativistic beaming. Coordinated multifrequency observations were carried out with Rossi X-Ray Timing Explorer (RXTE), Advanced Satellite for Cosmology and Astrophysics (ASCA; or, Astro-D), Roentgen Satellite (ROSAT), and International Ultraviolet Explorer (IUE) and from many ground-based observatories, covering most accessible wavelengths. The well-sampled, simultaneous RXTE light curve shows an outburst of lower amplitude (factor of approx. or equal to 3) well correlated with the gamma-ray flare without any lag larger than the temporal resolution of approx. 1 day. The optical-UV light curves, which are not well sampled during the high-energy flare, exhibit more modest variations (factor of approx. 2) and a lower degree of correlation. The flux at millimetric wavelengths was near a historical maximum during the gamma-ray flare peak, and there is a suggestion of a correlated decay. We present simultaneous spectral energy distributions of 3C 279 prior to and near to the flare peak. The gamma-rays vary by more than the square of the observed IR-optical flux change, which poses some problems for specific blazar emission models. The synchrotron self-Compton (SSC) model would require that the largest synchrotron variability occurred in the mostly unobserved submillimeter/far-infrared region. Alternatively, a large variation in the external photon field could occur over a time scale of a few days. This occurs naturally in the "mirror" model wherein the flaring region in the jet photoionizes nearby broad emission line clouds, which, in turn, provide soft external photons that are Comptonized to gamma-ray energies.

Wehrle, A. E.↗

Resistance of virus to extinction on bottleneck passages: study of a decaying and fluctuating pattern of fitness loss

RNA viruses display high mutation rates and their populations replicate as dynamic and complex mutant distributions, termed viral quasispecies. Repeated genetic bottlenecks, which experimentally are carried out through serial plaque-to-plaque transfers of the virus, lead to fitness decrease (measured here as diminished capacity to produce infectious progeny). Here we report an analysis of fitness evolution of several low fitness foot-and-mouth disease virus clones subjected to 50 plaque-to-plaque transfers. Unexpectedly, fitness decrease, rather than being continuous and monotonic, displayed a fluctuating pattern, which was influenced by both the virus and the state of the host cell as shown by effects of recent cell passage history. The amplitude of the fluctuations increased as fitness decreased, resulting in a remarkable resistance of virus to extinction. Whereas the frequency distribution of fitness in control (independent) experiments follows a log-normal distribution, the probability of fitness values in the evolving bottlenecked populations fitted a Weibull distribution. We suggest that multiple functions of viral genomic RNA and its encoded proteins, subjected to high mutational pressure, interact with cellular components to produce this nontrivial, fluctuating pattern.

Serial Passage↗

Temporal coherent control of resonant two-photon double ionization of the hydrogen molecule via doubly excited states

Here, we use time-delayed, counter-rotating, circularly polarized few-cycle attosecond nonoverlapping pulses to study the temporal coherent control of the resonant process of two-photon double ionization (TPDI) of hydrogen molecule via doubly excited states for pulse propagation direction along $\hat k$ either parallel or perpendicular to the molecular axis $\hat R$. For $\hat k$∥ $\hat R$ and a pulse carrier frequency of 36 eV resonantly populating the Q 2 1 Π$^+_u$ (1) doubly excited state as well as other 1 Π$^+_u$ doubly excited states, we find that the indirect ionization pathway through these doubly excited states changes the character of the kinematical vortex-shaped momentum distribution produced by the two direct ionization pathways from fourfold to twofold rotational symmetry. This result is similar to what found in TPDI of the He atom involving 1 P$^ o_ {±1}$ doubly excited states; however, angular distributions exhibiting a quantum beat effect between the ground state and a doubly excited state seen for the He atom are observed here for its molecular counterpart with an anomaly in shape and magnitude, not in frequency. The sixfold differential probability integrated over the azimuthal angle of the photoelectron pair shows that this anomaly is due to autoionization decays and quantum beats between doubly excited states. For $\hat k$⟂$\hat R$ and a broadband pulse carrier frequency of 30 eV populating the Q 1 1 Π$^+_u$(1), Q 1 1 Σ$^+_u$(1), Q 2 1 Π$^+_u$(1) , and Q 1 1 Σ$^+_u$ (2) doubly excited states, the momentum distribution is shown to exhibit dynamical electron vortices with four spiral arms, which originates from the interplay between the 1 Δ$^+_ g$ , 1 Π$^+_ g$, and 1 Σ$^+_ g$ dynamical ionization amplitudes. Our treatment within either the adiabatic-nuclei approximation or fixed-nuclei approximation shows that the latter provides a very good account for this correlated process.

74 ATOMIC AND MOLECULAR PHYSICS↗

Converting dark matter to dark radiation does not solve cosmological tensions

Tensions between cosmological parameters (in particular the local expansion rate H 0 and the amplitude of matter clustering S8) inferred from low-redshift data and data from the cosmic microwave background (CMB) and large-scale structure (LSS) experiments have inspired many extensions to the standard cosmological model, LCDM. Models which simultaneously lessen both tensions are of particular interest. We consider one scenario with the potential for such a resolution, in which some fraction of the dark matter has converted into dark radiation since the release of the CMB. Such a scenario encompasses and generalizes the more standard "decaying dark matter" model, allowing additional flexibility in the rate and time at which the dark matter converts into dark radiation. In this paper, we constrain this scenario with a focus on exploring whether it can solve (or reduce) these tensions. We find that such a model is effectively ruled out by CMB data, in particular by the reduced peak-smearing due to CMB lensing on the power spectrum and the excess integrated Sachs--Wolfe (ISW) signal caused by the additional dark energy density required to preserve flatness after dark matter conversion into dark radiation. Thus, such a model does not have the power to reduce these tensions without further modifications. This conclusion extends and generalizes related conclusions derived for the standard decaying dark matter model.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic-Field-Response Measurement-Acquisition System

A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a response inflection. The "transmit-receive-compare" of sequential harmonics is repeated until the inflection is identified. The harmonic producing the amplitude inflection is the sensor resonant frequency. Resonant frequency and response amplitude are stored and then correlated to calibration data.

Woodward, Stanley E.↗