Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Paint Analysis

Lewis Research Center (LEW) has assisted The Cleveland Museum of Art (CMA) in analyzing the museum's paintings. Because of the many layers of paint that are often involved, this is a complex process. The cross-section of a paint chip must be scanned with a microscope to determine whether a paint layer is original or a restoration. The paint samples, however, are rarely flat enough for high magnification viewing and are frequently scratched. LEW devised an automated method that produces intact, flat, polished paint cross-sections. A sophisticated microprocessor-controlled grinding and polishing machine was manually employed in preparation of exotic samples for aerospace research was a readily adaptable technique. It produced perfectly flat samples with clearly defined layers. The process has been used successfully on a number of paintings, and LEW and CMA are considering additional applications.

Source record↗

Genesis Discovery Mission: Science Canister Processing at JSC

Genesis addresses questions about materials and processes involved in the origins of the solar system by providing precise knowledge of solar isotopic and elemental compositions. Solar wind ions are collected and returned to Earth for analyses. The spacecraft has two primary instruments to collect solar wind: a set of collector arrays each of which can deploy to sample different solar wind regimes, and a concentrator that is an electrostatic mirror to concentrate and focus low mass ions onto a 6 cm target. One of the key challenges to obtaining a good sample of solar wind, uncontaminated by terrestrial atoms, is to have clean collection surfaces in a clean sample canister and clean facilities to handle the samples for allocation and future reference. The Johnson Space Center (JSC) is responsible for contamination control for the mission, for ensuring the cleanliness of collection surfaces, and for providing a clean environment for handling of the samples. The level of cleanliness required is high; at the time of analysis (after sample return), the surface contamination by C, N, O must each be <10(exp 15) atoms/sq cm and for other elements the number of atoms/sq cm of each surface contaminant shall not exceed the estimated solar wind fluence of the species (varies by element between U at approx. 10(exp 4) atoms/sq cm to Fe, Si, Mg, and Ne at approx. 10(exp 12) atoms/sq cm).

Stansbery, E. K.↗

Post-Flight Microbial Analysis of Samples from the International Space Station Water Recovery System and Oxygen Generation System

The Regenerative, Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS) includes the the Water Recovery System (WRS) and the Oxygen Generation System (OGS). The WRS consists of a Urine Processor Assembly (UPA) and Water Processor Assembly (WPA). This report describes microbial characterization of wastewater and surface samples collected from the WRS and OGS subsystems, returned to KSC, JSC, and MSFC on consecutive shuttle flights (STS-129 and STS-130) in 2009-10. STS-129 returned two filters that contained fluid samples from the WPA Waste Tank Orbital Recovery Unit (ORU), one from the waste tank and the other from the ISS humidity condensate. Direct count by microscopic enumeration revealed 8.38 x 104 cells per mL in the humidity condensate sample, but none of those cells were recoverable on solid agar media. In contrast, 3.32 x lOs cells per mL were measured from a surface swab of the WRS waste tank, including viable bacteria and fungi recovered after S12 days of incubation on solid agar media. Based on rDNA sequencing and phenotypic characterization, a fungus recovered from the filter was determined to be Lecythophora mutabilis. The bacterial isolate was identified by rDNA sequence data to be Methylobacterium radiotolerans. Additional UPA subsystem samples were returned on STS-130 for analysis. Both liquid and solid samples were collected from the Russian urine container (EDV), Distillation Assembly (DA) and Recycle Filter Tank Assembly (RFTA) for post-flight analysis. The bacterium Pseudomonas aeruginosa and fungus Chaetomium brasiliense were isolated from the EDV samples. No viable bacteria or fungi were recovered from RFTA brine samples (N= 6), but multiple samples (N = 11) from the DA and RFTA were found to contain fungal and bacterial cells. Many recovered cells have been identified to genus by rDNA sequencing and carbon source utilization profiling (BiOLOG Gen III). The presence of viable bacteria and fungi from WRS and OGS subsystems demonstrates the need for continued monitoring of ECLSS during future ISS operations and investigation of advanced antimicrobial controls.

Birmele, Michele N.↗

Waypoint Following Dynamics of a Quaternion Error Feedback Attitude Control System

Closed-loop attitude steering can be used to implement alternative attitude maneuvers by using a conventional attitude control system to track a non-standard attitude profile sampled as a series of sequential commands. The idea has been employed in practice to perform zero-propellant maneuvers on the International Space Station and minimum time maneuvers on NASA’s TRACE space telescope. A challenge for operational implementation of the idea is the finite capacity of a space vehicle’s command storage buffer. One approach to mitigate the problem is to downsample-and-hold the attitude commands so that the attitude control system to follows a set of waypoints. This paper explores the waypoint following dynamics of a quaternion error feedback control law for downsample-and-hold. It is shown that downsample-and-hold induces a ripple between downsamples that causes the satellite angular rate to significantly overshoot the desired limit. Analysis in the z-domain is carried out in order to understand the phenomenon. An interpolating Chebyshev-type filter is proposed that allows attitude commands to be encoded in terms of a small set of filter coefficients. Using the interpolating filter, commands can be issued at the ACS rate but with significantly reduced memory requirements. The attitude control system of NASA’s Lunar Reconnaissance Orbiter is used as an example to illustrate the behavior of a practical attitude control system.

Mark Karpenko↗

Neuromorphic Learning From Noisy Data

Two reports present numerical study of performance of feedforward neural network trained by back-propagation algorithm in learning continuous-valued mappings from data corrupted by noise. Two types of noise considered: plant noise which affects dynamics of controlled process and data-processing noise, which occurs during analog processing and digital sampling of signals. Study performed with view toward use of neural networks as neurocontrollers to substitute for, or enhance, performances of human experts in controlling mechanical devices in presence of sensor and actuator noise and to enhance performances of more-conventional digital feedback electronic process controllers in noisy environments.

Merrill, Walter C.↗

Dietary and Urinary Sulfur can Predict Changes in Bone Metabolism During Space Flight

Mitigating space flight-induced bone loss is critical for space exploration, and diet can play a major role in this effort. Previous ground-based studies provide evidence that dietary composition can influence bone resorption during bed rest. In this study we examined the role of dietary intake patterns as one factor that can influence bone mineral loss in astronauts during space flight. Crew members were asked to consume, for 4 days at a time, prescribed menus with either a low (0.3-0.6 g/mEq) or high (1.0-1.3 g/mEq) ratio of animal protein to potassium (APro:K). Menus were developed for each crewmember, and were designed to meet both crew preferences and study constraints. Intakes of energy, total protein, calcium, and sodium were held relatively constant between the two diets. The order of the menus was randomized, and crews completed each set (low and high) once before and twice during space flight, for a total of 6 controlled diet sessions. One inflight session and three postflight sessions (R+30, R+180, R+365) monitored typical dietary intake. As of this writing, data are available from 14 crew members. The final three subjects' inflight samples are awaiting return from the International Space Station via Space-X. On the last day of each of the 4-d controlled diet sessions, 24-h urine samples were collected, along with a fasting blood sample on the morning of the 5th day. Preliminary analyses show that urinary excretion of sulfate (normalized to lean body mass) is a significant predictor of urinary n-telopeptide (NTX). Dietary sulfate (normalized to lean body mass) is also a significant predictor of urinary NTX. The results from this study, will be important to better understand diet and bone interrelationships during space flight as well as on Earth. This study was funded by the Human Health Countermeasures Element of the NASA Human Research Program.

Zwart, Sara R.↗

Overview of CFD Validation Experiments for Circulation Control Applications at NASA

Circulation control is a viable active flow control approach that can be used to meet the NASA Subsonic Fixed Wing project s Cruise Efficient Short Take Off and Landing goals. Currently, circulation control systems are primarily designed using empirical methods. However, large uncertainty in our ability to predict circulation control performance has led to the development of advanced CFD methods. This paper provides an overview of a systematic approach to developing CFD tools for basic and advanced circulation control applications. This four-step approach includes "Unit", "Benchmar", "Subsystem", and "Complete System" experiments. The paper emphasizes the ongoing and planned 2-D and 3-D physics orientated experiments with corresponding CFD efforts. Sample data are used to highlight the challenges involved in conducting circulation control computations and experiments.

Jones, G. S.↗

Experiment K-7-28: Lung Morphology Study

There are no previous studies investigating the effect of microgravity exposure during spaceflight on lung tissue. We examined the ultrastructure of the left lungs of 5 Czechoslovakian Wistar rats flown on the 13 day, 19+ hr. Cosmos 2044 mission, and compared them to 5 vivarium and 5 synchronous controls at 1-g conditions, and 5 rats exposed to 14 days of tail-suspension. Within 10 minutes of sacrifice by decapitation, the lungs were removed and immersed in 3% glutaraldehyde in 0.1M phosphate buffer (total osmolarity of the fixative: 560 mOsm; pH = 7.4). The tissue stored at 5 C was transported to our laboratory where it was processed for light and electron microscopy. No significant perivascular cuffing caused by interstitial edema was present in the tissue samples. Some of the flight, tail-suspended, and synchronous control rats showed alveolar edema, while vivarium controls did not. The pulmonary capillaries appeared to be more congested in the flight animals than in the other groups. This could be related to the increased hematocrit due to the microgravity exposure. In all 5 flight, 4 tail-suspended, and 3 synchronous rats, red blood cells (RBC) were present in the alveolar spaces. The RBC were either suspended free in the alveoli or observed lining the alveolar wall. The frequency of RBC lining the alveolar walls appeared greater in the dorsal (gravity non-dependent) than in ventral (gravity dependent) regions of the lung in these three animal groups. In 3 of the vivarium controls, a few RBC were found in the alveolar spaces. Intra-capillary fluid-filled vesicles were observed in the flight, tail-suspended and synchronous animals, but not in the vivarium controls. The formation of intra-capillary fluid-filled vesicles has been previously associated with pulmonary hypertension induced by high altitude exposure and mitral stenosis. In conclusion, pulmonary hemorrhage and alveolar edema of unknown origin occurred to a greater extent in the flight, tail-suspended, and synchronous control animals, and in the dorsal regions of the lung when compared to the vivarium controls. The etiology of these changes, which are possibly due to an increase in pulmonary vascular pressure, requires further investigation.

West, J. B.↗

On the continuous dependence with respect to sampling of the linear quadratic regulator problem for distributed parameter system

The convergence of solutions to the discrete- or sampled-time linear quadratic regulator problem and associated Riccati equation for infinite-dimensional systems to the solutions to the corresponding continuous time problem and equation, as the length of the sampling interval (the sampling rate) tends toward zero(infinity) is established. Both the finite-and infinite-time horizon problems are studied. In the finite-time horizon case, strong continuity of the operators that define the control system and performance index, together with a stability and consistency condition on the sampling scheme are required. For the infinite-time horizon problem, in addition, the sampled systems must be stabilizable and detectable, uniformly with respect to the sampling rate. Classes of systems for which this condition can be verified are discussed. Results of numerical studies involving the control of a heat/diffusion equation, a hereditary or delay system, and a flexible beam are presented and discussed.

Rosen, I. G.↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161 – 18 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch, a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes are proving an effective control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Formulation and verification of frequency response system identification techniques for large space structures

For the past several years much effort has been given to the development of techniques for designing control systems for large space structures (LSS's). The main objective of these efforts has been to develop a LSS control methodology that produces designs that meet strenuous performance requirements and are robust to model inaccuracies. Unfortunately, performance and robustness are conflicting requirements. Because LSS's can not be fully tested on ground, it has become an accepted fact that the design of LSS control systems to meet performance requirements can not be completed until the LSS is placed on-orbit and tested and an accurate model is extracted from on-orbit test results. Modern MIMO sampled-data frequency response design techniques are viable candidates for designing LSS control systems. First, this paper presents techniques for performing MIMO system identification (ID) from test data. Then, techniques for improving the performance of the system ID process in the presence of noise are presented. Finally, practical utility of the system ID approaches are validated by the presentation of results obtained from application on the LSS Ground Test Facility at Marshall Space Flight Center.

Mitchell, Jerrel R.↗

Repurposing Drilling Control Diagnostics for Subsurface Edge Detection and Boundary Advisement During Planetary Drilling

Informed decision-making during lunar drilling and sampling missions will require data monitoring tools and specialized ground data systems. Accurate and updated situational awareness, with ongoing data monitoring, is critical for timely responses by to incoming science data. Traverse plans and scheduled activities may need to be flexibly changed in order to react to unexpected data or situations. Unlike (for example) Mars missions, the relative lightspeed closeness of the Moon allows for near-real-time ground processing of incoming mission and instrument data. An Apollo-class lunar regolith drill will in a sense “travel” a meter or two vertically at a given subsurface characterization site. As the drill penetrates into lunar regolith, it is likely to encounter a range of material densities, orientations, fracture toughness, and (perhaps) ice percentages. Lunar drill telemetry can provide science teams with a valuable first look into the subsurface structure, the regolith bulk properties, and constituents at each drilled site. Real-time AI-based recognition and reaction to downhole situations has been developed for automated deeper drilling on Mars and beyond. We can leverage the same knowledge bases and pattern-matching as areal-time interpreter of the subsurface, a situational awareness tool during drilling operations. We recently (Sept. 2019) demonstrated this AI drilling monitoring and analysis capability, in control of in-situ drilling and sampling operations, mounted on a KREX-2 rover in Chile’s Atacama Desert. Terrestrial automated drilling log analyses in oil exploration have used similar machine learning techniques in classifying and identifying features in drilling logs –but these typically are designed assuming a drilling fluid influencing downhole measurements and data (permeability, resistivity). Drilling models and existing AI software designed to detect and respond to drilling faults and hard materials can be repurposed, for near-real-time (ground-based) interpretation of drilling telemetry –a potentially valuable advisory tool for strata boundaries and changes in drilling parameters. On the Moon, this approach could be used to study the structure and to some extent the composition of lunar regolith vs. borehole depth, based on recognizable variations in fracture hardness, drilling energy and penetration rates while actively drilling. Since the early 2000s, a series of increasingly-capable real-time drilling telemetry interpretation and characterization software tools have been developed. These subsurface models and software tools have monitored the real-time drilling data received, and automatically identified changes in drill behavior (e.g., encountering a harder target layer, bit inclusions, drill choking due to infall downhole, and others) correlating these with subsurface structures and features. We discuss the mappings between drill borehole parameters, faults or events detected, and modeled changes in rock layer boundaries, in examples drawn from field testing at analog sites in an Arctic impact crater, Rio Tinto, and Chile’s Atacama Desert. These demonstrate how subsurface structural boundaries led to fault detections and responses by the software.

drilling advisor↗

Tritium trick

Large controlled amounts of helium in uniform concentration in thick samples can be obtained through the radioactive decay of dissolved tritium gas to He3. The term, tritium trick, applies to the case when helium, added by this method, is used to simulate (n,alpha) production of helium in simulated hard flux radiation damage studies.

Green, W. V.↗

Bearing strength of lunar soil.

Bearing load vs penetration curves have been measured on a 1.3 g sample of lunar soil from the scoop of the Surveyor 3 soil mechanics surface sampler, using a circular indentor 2 mm in diameter. Measurements were made in an Earth laboratory, in air. This sample provided a unique opportunity to evaluate earlier, remotely controlled, in-situ measurements of lunar surface bearing properties. Bearing capacity, measured at a penetration equal to the indentor diameter, varied from 0.02-0.04 N/sq cm at bulk densities of 1.15 g/cu cm to 30-100 N/sq cm at 1.9 g/cu cm. Deformation was by compression directly below the indentor at bulk densities below 1.61 g/cu cm, by outward displacement at bulk densities over 1.62 g/cu cm. Preliminary comparison of in-situ remote measurements with those on returned material indicates good agreement if the lunar regolith at Surveyor 3 has a bulk density of 1.6 g/cu cm at 2.5 cm depth.

Jaffe, L. D.↗

Geographic applications of ERTS-1 data to landscape change

The analysis of landscape change requires large area coverage on a periodic basis in order to analyze aggregate changes over an extended period of time. To date, only the ERTS program can provide this capability. Three avenues of experimentation and analysis are being used in the investigation: (1) a multi-scale sampling procedure utilizing aircraft imagery for ground truth and control; (2) a densitometric and computer analytical experiment for the analysis of gray tone signatures, comparisons and ultimately for landscape change detection and monitoring; and (3) an ERTS image enhancement procedure for the detection and analysis of photomorphic regions.

Rehder, J. B.↗