Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

X-Ray Polarization of Z-Type Neutron Star Low-Mass X-Ray Binaries II. Spectropolarimetric Analysis

IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.

accretion↗

Method and system for imaging a radiation source

A method for imaging a radiation source, and a device that utilizes these methods that in one embodiment include the steps of: calculating at least one Compton cone of a first parameter of a radiation emission from information received from a sensor occurrence; and tracing this Compton cone on to a unit sphere having preselected characteristics using an estimated angular uncertainty to limit at least a portion of said tracing. In another embodiment of the invention at least two Compton cones are calculated and then intersected upon a predefined surface such as a sphere. These intersection points can then be iterated over a preselected series of prior events.

Myjak, Mitchell J↗

Computational modeling and sensitivity in uniform DT burn

Understanding deuterium-tritium (DT) fusion is essential to achieving ignition in inertial confinement fusion. A burning DT plasma in a three temperature (3T) approximation and uniform in space is modeled as a system of five non-linear coupled ODEs. Special focus is given to the effects of Compton coupling, Planck opacity, and electron-ion coupling terms. Semi-implicit differencing is used to solve the system of equations. Time step size is varied to examine the stability and convergence of each solution. Data from NDI, SESAME, and TOPS databases is extracted to create analytic fits for the reaction rate parameter, the Planck opacity, and the coupling frequencies of the plasma temperatures. The impact of different high order fits to NDI date (the reaction rate parameter), and using TOPS versus SESAME opacity data is explored, and the sensitivity to several physics parameters in the coupling terms are also examined. The base model recovers the accepted 3T results for the temperature and burn histories. The Compton coupling is found to have a significant impact on the results. Varying a coefficient of this term shows that the model results can give reasonably good agreement with the peak temperatures reported in multi-group results as well as the accepted 3T results. The base model assumes a molar density of 1 mol/cm{sup 3}, as well as a 5 keV intial temperature for all three temperatures. Different intial conditions are explored as well. Intial temperatures are set to 1 and 3 keV, the ratio of D to T is varied (2 and 3 as opposed to 1 in the base model), and densities are set to 10 mol/cm{sup 3} and 100 mol/cm{sup 3}. Again varying the Compton coefficient, the ion temperature results in the higher density case are in reasonable agreement with a recently published kinetic model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uniform DT 3T burn: computations and sensitivities

A numerical model was developed in C to integrate the nonlinear deutrium-tritium (DT) burn equations in a three temperature (3T) approximation for spatially uniform test problems relevant to Inertial Confinement Fusion (ICF). Base model results are in excellent agreement with standard 3T results. Data from NDI, SESAME, and TOPS databases is extracted to create fits for the reaction rate parameter, the Planck opacity, and the coupling frequencies of the plasma temperatures. The impact of different fits (e.g., TOPS versus SESAME opacity data, higher order polynomial fits ofNDI data for the reaction rate parameter) were explored, and sensitivity to several model inputs are presented including: opacity data base, Coulomb logarithm, and Bremsstrahlung. Sensitivity to numerical integration time step size, and the relative insensitivity to the discretized numerics and numerical integration method was demonstrated. Variations in the IC for densities and temperatures were explored, showing similar DT burn profiles in most cases once ignition occurs. A coefficient multiplying the Compton coupling term (default, A = 1) can be adjusted to approximate results from more sophisticated models. The coefficient was reset (A = 0.4) to match the maximum temperatures resulting from standard multi-group simulations of the base case test problem. Setting the coefficient to a larger value, (A = 0.6) matches maximum ion temperatures in a kinetic simulation of a high density ICF-like regime. Matching peak temperatures does not match entire temperature-time profiles, indicating the Compton coefficient is density and time dependent as the photon distribution evolves. In the early time burn during the ignition of the DT, the present model with modified Compton coupling provides a very simple method to obtain a much improved match to the more accurate solution from the multi-group radiation model for these DT burn regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Concept of a Gamma-gamma Higgs Factory Driven by Thin Laser Targets and Energy Recovery Linacs

A gamma-gamma collider has long been considered an option for a Higgs Factory. Such photon colliders usually rely on Compton back-scattering for generating high energy gamma photons and further Higgs bosons through gamma-gamma collisions. The presently existing proposals or design concepts all have chosen a very thick laser target (i.e., high laser photon intensity) for Compton scatterings. In this paper, we present a new design concept of a gamma-gamma collider utilizing a thin laser target (i.e., relatively low photon density), thus leading to a low electron to gamma photon conversion rate. This new concept eliminates most useless and harmful low energy soft gamma photons from multiple Compton scattering so the detector background is improved. It also greatly relaxes the requirement of the high peak power of the laser, a significant technical challenge. A high luminosity for such a gamma-gamma collider can be achieved through an increase of the bunch repetition rate and current of the driven electron beam. Further, multi-pass recirculating linac could greatly reduce the linac cost and energy recovery is required to reduce the needed RF power.

43 PARTICLE ACCELERATORS↗

Plastic Scintillators Light Yield Energy Calibration.

Currently we are investigating the inclusion of organotin compounds in polystyrene material to improve plastic scintillators full gamma-ray energy sensitivity with the ultimate goal of achieving spectroscopy. Accurate evaluation of light yield from the newly developed scintillators is crucial to assess merits of compounds and chemical process used in the scintillators development. Full gamma-ray energy peak in measured gammaray spectrum, resulting from total absorption of gamma-ray energy, would be ideal in evaluating the light yield from the new scintillators. However, full energy sensitivity achieved thus far is not statistically viable for fast and accurate light yield energy calibration from the new scintillators. The Compton edge in measured gamma-ray spectrum has been found as an alternate gamma-ray spectrum feature that can be exploited for characterizing the light yield energy from the newly developed plastic scintillators. In this study we present technique implemented for accurate light yield energy calibration using the Compton edge. Results obtained were very encouraging and promise the possibility of using the Compton edge for energy calibration in detectors with poor energy resolution such as plastic and liquid scintillators.

36 MATERIALS SCIENCE↗

Constraints on the Redshift Evolution of Astrophysical Feedback with Sunyaev-Zeldovich Effect Cross-Correlations

An understanding of astrophysical feedback is important for constraining models of galaxy formation and for extracting cosmological information from current and future weak lensing surveys. The thermal Sunyaev-Zel'dovich effect, quantified via the Compton-$y$ parameter, is a powerful tool for studying feedback, because it directly probes the pressure of the hot, ionized gas residing in dark matter halos. Cross-correlations between galaxies and maps of Compton-$y$ obtained from cosmic microwave background surveys are sensitive to the redshift evolution of the gas pressure, and its dependence on halo mass. In this work, we use galaxies identified in year one data from the Dark Energy Survey and Compton-$y$ maps constructed from Planck observations. We find highly significant (roughly $12\sigma$) detections of galaxy-$y$ cross-correlation in multiple redshift bins. By jointly fitting these measurements as well as measurements of galaxy clustering, we constrain the halo bias-weighted, gas pressure of the Universe as a function of redshift between $0.15 \lesssim z \lesssim 0.75$. We compare these measurements to predictions from hydrodynamical simulations, allowing us to constrain the amount of thermal energy in the halo gas relative to that resulting from gravitational collapse.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Electron Beam Polarimetry in Hall C at Jefferson Lab

The electron beam polarization in experimental Hall C at Jefferson Lab is measured using two devices. The Hall-C/Basel M\o ller polarimeter measures the beam polarization via electron-electron scattering and utilizes a novel target system in which a pure iron foil is driven to magnetic saturation (out of plane) using a superconducting solenoid. A Compton polarimeter measures the polarization via electron-photon scattering, where the photons are provided by a high-power, CW laser coupled to a low gain Fabry-Perot cavity. In this case, both the Compton-scattered electrons and backscattered photons provide measurements of the beam polarization. Results from both polarimeters, acquired during the Q-Weak experiment in Hall C, will be presented. In particular, the results of a test in which the M\o ller and Compton polarimeters made interleaving measurements at identical beam currents will be shown. In addition, plans for operation of both devices after completion of the Jefferson Lab 12 GeV Upgrade will also be discussed.

Gaskell, David↗

Application of the PHDS Germanium Gamma-ray Imager (GeGI) in Facility Decontamination Assessment - 19471

As part of a site wide investigation, U.S. EPA Region 5 had to assess the nature and extent of contamination in a former radioactive source manufacturing facility. This work involved verification of the radioisotope expected, ensuring no other radioisotopes were present, and quantification of the activity and areal extent of contamination throughout the facility. The device used to support this assessment work was the Germanium Gamma-ray Imager (GeGI) manufactured by PHDS Co. of Knoxville, Tennessee. GeGI is a germanium-semiconductor imaging detector system that provides identification, location, and quantification of radioactive materials within its field of view. GeGI provides the highest fidelity radiological assay information including the best gamma-ray energy resolution and spatial localization of any existing technology, including gamma-ray energy resolution of ∼0.3% full-width half-max (FWHM) at 662 keV and angular location resolution ∼ +/-1 degree. The GeGI is a mechanically cooled, portable system well-suited to field operations. PHDS Co. also provided on-site support during assessment operations and performed subsequent data analysis. Gamma-ray spectral data and associated images were collected with GeGI in six primary areas of the facility having significant residual contamination. A total of 61 gamma-ray spectrum/image sets were collected over the course of three working days (22 Compton images and 39 Pinhole/Compton images). During data collection, Compton imaging was used as the means by which to identify and prioritize hotspots. After contaminated regions were identified via Compton imaging, short-distance Pinhole spectrum/image sets were collected for additional analysis. All of the spectrum/image sets were analyzed to determine the radioisotope distribution within the GeGI field of view, as well as to provide an estimate of the activity associated with each hotspot. It was determined that the nature of residual contamination present was distributed across specific areas of elevated activity, where in some areas there was significant accumulation of contaminated material. It was also determined that no discrete sources of high-activity were present, as would be expected in the case of radioactive material product intended for sealed source manufacture. Results included the activity of residual contamination for each of the areas assessed, and an estimate of the physical area over which that contamination was distributed. It was anticipated by EPA that if decontamination were to be performed that it would involve some type of concrete scabbling or other means of physical removal of contaminated material. The GeGI data could be used to estimate the areal extent (square footage) of concrete removal that would be required for decontamination. Using the activity estimate data from the GeGI along with an estimated depth of concrete removal, planning could be performed for decontamination work (equipment and personnel), waste collection, packaging, transportation, and disposal, along with an associated cost estimate. With regard to health and safety, use of the GeGI reduced the radiation dose to the EPA R5 staff performing the assessment work. The GeGI is a non-destructive device that supports assessment of radioactively contaminated areas and sources from a distance, reducing the need for close contact to radiation, and the time necessary for personnel to operate near such hazards. Use of the GeGI in this facility assessment was our first attempt to apply this technology in what proved to be a quick and efficient decontamination assessment method. The GeGI can assess the nature and extent of residual contamination in a facility, first by quickly identifying the areas of elevated activity, followed by refined measurement and assessment of those elevated areas. The GeGI data can then be used to develop planning and a cost estimate of required decontamination and waste management activities. Since it's a non-destructive gamma identification and imaging device, it can reduce the distance of workers from radioactive sources and the dose incurred from assessment work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanostructured Lanthanum Halides and CeBr3 for Nuclear Radiation and Detection

Scintillator materials are used to detect, and in some cases identify, gamma rays. Higher performance scintillators are expensive, hard to manufacture, fragile, and sometimes require liquid nitrogen or cooling engines. But whereas lower-quality scintillators are cheap, easy to manufacture, and more rugged, their performance is lower. At issue: can the desirable qualities of high-and low-performance scintillators be combined to achieve better performance at lower cost? Preliminary experiments show that a LaF{sub 3}:Ce oleic acid-based nanocomposite exhibits a photopeak when exposed to {sup 137}Cs source gamma-radiation. The chemical synthesis of the cerium-doped lanthanum halide nanoparticles are scalable and large quantities of material can be produced at a time, unlike typical crystal growth processes such as the Bridgeman process. Using a polymer composite (Figure 1), produced by LANL, initial measurements of the unloaded and 8% LaF{sub 3}:Ce-loaded sample have been made using {sup 137}Cs sources. Figure 2 shows an energy spectrum acquired for CeF{sub 3}. The lighter plot is the measured polymer-only spectrum and the black plot is the spectrum from the nanocomposite scintillator. As the development of this material continues, the energy resolution is expected to improve and the photopeak-to-Compton ratio will become greater at higher loadings. These measurements show the expected Compton edge in the polymer-only sample, and the Compton edge and photo-peak expected in the nanophosphor composites that LANL has produced. Using a porous VYCORR with CdSe/ZnS core shell quantum dots, Letant has demonstrated that he has obtained signatures of the 241Am photopeak with energy resolution as good at NaI (Figure 3). We begin with the fact that CeBr{sub 3} crystals do not have a self-activity component as strong as the lanthanum halides. The radioactive 0.090% {sup 138}La component of lanthanum leads to significant self-activity, which will be a problem for very large detector volumes. Yet a significant strength of the nanostructure detector concept is the ability to create extremely large detector volumes by mixing nanoparticles into a transparent matrix. This would argue for use of nanoparticles other than lanthanum halides. Nanocomposites are easy to prepare; it is much less costly to use nanocomposites than to grow large whole crystals of these materials. The material can be fabricated at an industrial scale, further reducing cost. This material potentially offers the performance of $300/cc material (e.g., lanthanum bromide) at a cost of $1/cc. Because the material acts as a plastic, it is rugged and flexible, and can be made in large sheets, increasing the sensitivity of a detector using it. It would operate at ambient temperatures. Very large volumes of detector may be produced at greatly reduced cost, enhancing the non-proliferation posture of the nation for the same dollar value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropic Decomposition of Energetic Materials

Using a white x-ray synchrotron beam, we have dynamically studied radiation-induced decomposition in single crystalline PETN and TATB. By monitoring the integrated intensity of selected diffraction spots via a CCD x-ray camera as a function of time, we have found that the decomposition rate varies dramatically depending upon the orientation of the crystalline axes relative to polarized x-ray beam and for differing diffracting conditions (spots) within the same crystalline orientation. We suggest that this effect is due to Compton scattering of the polarized x-rays with electron clouds that is dependent upon their relative orientation. This novel effect may yield valuable insight regarding anisotropic detonation sensitivity in energetic materials such as PETN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DVCS with longitudinally polarized target using CLAS at 6 GeV

Deeply Virtual Compton Scattering (DVCS) is one of the simplest processes that can be described in terms of Generalized Parton Distributions (GPDs). The target single-spin asymmetry (target SSA) in the reaction ep-vector{yields}ep{gamma} is directly proportional to the imaginary part of the DVCS amplitude, and gives access to a combination of GPDs namely H-tilde, H, and E. This asymmetry will be measured in a dedicated experiment at Jefferson Lab using the CEBAF 6-GeV polarized electron beam, a polarized solid-state {sup 14}NH{sub 3} target, and the CEBAF Large Acceptance Spectrometer (CLAS) together with the Inner Calorimeter (IC). The expected asymmetry from leading-order calculations is in the range of 20% to 40%, depending on the kinematics and on the GPD model used. The DVCS amplitude will be mapped out in the Q{sup 2} region from 1 to 4 GeV{sup 2}, x{sub B} from 0.15 to 0.55 and -t from 0.1 to 2 GeV{sup 2} providing new constraints on the GPDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GPDs and DVCS with Positrons

The beam charge asymmetry helps to isolate the real part of the deeply virtual Compton scattering (DVCS) amplitude. It is discussed what information can be gained both from the real and imaginary part of the DVCS amplitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Positrons at Jefferson Lab

We review the compelling case for establishing a capability to accelerate positrons at Jefferson Lab. The potential applications range from the study of two-photon exchange and deeply-virtual Compton scattering to exploiting the charged current weak interaction to probe the flavor structure of hadrons and nuclei. There are also fascinating ideas for using such a capability to discover new physics beyond the Standard Model of nuclear and particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Generalized Parton Distribution program after the Jefferson Lab 12 GeV upgrade

The Generalized Parton Distribution framework was introduced in the late 90's and describes the nucleon in a revolutionary way, correlating the information from both momentum and transverse position space into experimentally accessible functions. After a brief introduction, this article reviews the Jefferson Lab 6 GeV measurements of Deeply Virtual Compton Scattering in Halls A and B, which give a unique access to Generalized Parton Distributions (GPD). The second half of this article reviews the Jefferson Lab 12 GeV upgrade in general terms, and then focuses on the GPD program in Halls A and B. This second generation of experiments will yield more accurate, more complete data in a wider kinematical range than any experiment ever before, using the full capability of a higher beam energy, higher luminosities, upgraded detectors and refined extraction techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Results in DIS, SIDIS and DES from Jefferson Lab

Jefferson Lab's electron accelerator in its present incarnation, with a maximum beam energy slightly above 6 GeV, has already enabled a large number of experiments expanding our knowledge of nucleon and nuclear structure (especially in Deep Inelastic Scattering--DIS--at moderately high x, and in the resonance region). Several pioneering experiments have yielded first results on Deeply Virtual Compton Scattering (DVCS) and other Deep Exclusive Processes (DES), and the exploration of the rich landscape of transverse momentum-dependent (TMD) structure functions using Semi-Inclusive electron scattering (SIDIS) has begun. With the upgrade of CEBAF to 12 GeV now underway, a significantly larger kinematic space will become available. The 12 GeV program taking shape will complete a detailed mapping of inclusive, TMD and generalized distribution functions for quarks, antiquarks and gluons in the valence region and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chiral dynamics and partonic structure at large transverse distances

In this paper, we study large-distance contributions to the nucleon’s parton densities in the transverse coordinate (impact parameter) representation based on generalized parton distributions (GPDs). Chiral dynamics generates a distinct component of the partonic structure, located at momentum fractions x≲M π /M N and transverse distances b~1/M π . We calculate this component using phenomenological pion exchange with a physical lower limit in b (the transverse “core” radius estimated from the nucleon’s axial form factor, R core =0.55 fm) and demonstrate its universal character. This formulation preserves the basic picture of the “pion cloud” model of the nucleon’s sea quark distributions, while restricting its application to the region actually governed by chiral dynamics. It is found that (a) the large-distance component accounts for only ~1/3 of the measured antiquark flavor asymmetry d¯-u¯ at x~0.1; (b) the strange sea quarks s and s¯ are significantly more localized than the light antiquark sea; (c) the nucleon’s singlet quark size for x<0.1 is larger than its gluonic size, (b 2 ) q+q¯ >(b 2 ) g , as suggested by the t-slopes of deeply-virtual Compton scattering and exclusive J/ψ production measured at HERA and FNAL. We show that our approach reproduces the general N c -scaling of parton densities in QCD, thanks to the degeneracy of N and Δ intermediate states in the large-N c limit. Finally, we also comment on the role of pionic configurations at large longitudinal distances and the limits of their applicability at small x.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scattering Observables from One- and Two-body Densities: Formalism and Application to $\pmb \gamma $ ${}^3\hbox {He}$ Scattering

We introduce the transition-density formalism, an efficient and general method for calculating the interaction of external probes with light nuclei. One- and two-body transition densities that encode the nuclear structure of the target are evaluated once and stored. They are then convoluted with an interaction kernel to produce amplitudes, and hence observables. Here, by choosing different kernels, the same densities can be used for any reaction in which a probe interacts perturbatively with the target. The method therefore exploits the factorisation between nuclear structure and interaction kernel that occurs in such processes. We study in detail the convergence in the number of partial waves for matrix elements relevant in elastic Compton scattering on 3 He. The results are fully consistent with our previous calculations in Chiral Effective Field Theory. But the new approach is markedly more computationally efficient, which facilitates the inclusion of more partial-wave channels in the calculation. We also discuss the usefulness of the transition-density method for other nuclei and reactions. Calculations of elastic Compton scattering on heavier targets like 4 He are straightforward extensions of this study, since the same interaction kernels are used. And the generality of the formalism means that our 3 He densities can be used to evaluate any 3 He elastic-scattering observable with contributions from one- and two-body operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗