Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Modeling the Impact of Flexible CHP on the Future Electric Grid In California

Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States. Typically fueled with natural gas, a CHP system combines a prime mover (such as a reciprocating engine) with a generator and heat recovery equipment, allowing operation at very high efficiencies (65–85%). Traditionally, CHP systems have been configured to serve local electrical and thermal loads at the sites where they are deployed. Units are sized to ensure a high capacity factor for the equipment, and the electricity generated tends to be used on site. CHP units in the United States already generate over 12% of the nation’s electricity. However, CHP’s potential benefits could be much greater if power generated could be used beyond the site, because the analysis was performed under the assumption that sites could use all the thermal output. Analysis of a few key sectors confirmed that this assumption is valid (for more information, see Appendix E). Those benefits could include improved grid reliability and resilience, as well as lower-cost options for providing energy and other grid services. The potential benefits also align well with grid modernization objectives, as shown in Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States., and greater electrification of loads, driven by carbon reduction priorities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MV Sea Change: Fuel Cell, Emissions, and Hydrogen Fueling Performance

The Sea Change Project, managed and financed by SWITCH Maritime, produced the first zero-emission 100% hydrogen fuel-cell powered commercial ferry in the world. The MV Sea Change is a 70-foot catamaran equipped with a 360-kW fuel cell powertrain and a 250-bar 246 kg capacity hydrogen storage system. The 75-passenger vessel began public passenger service in July 2024 as part of the San Francisco Bay Ferry system. Summarized here are aspects of the design of the vessel, its construction, and vessel bunkering with high-pressure hydrogen. Results from a fuel cell performance analysis are also presented, along with estimates of the greenhouse gas (GHG) and criterial pollutant emissions assuming different sourcings of hydrogen. Lessons learned from the project will be briefly reviewed.

08 HYDROGEN↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calibration-Free Quantitative Analysis of Lithium-Ion Battery (LiB) Electrode Materials Using Laser-Induced Breakdown Spectroscopy (LIBS)

Recent years have seen a surge in the demand for high-performance battery electrode materials for automotive and various electronic device applications. Improving battery performance requires precise knowledge of the structure–composition properties of active electrode materials. To this effect, quantitative and precise estimation of the composition of advanced electrode materials, containing trace amounts of dopants, provide immense value toward developing next-generation high-capacity battery materials. Herein, we demonstrate the application of calibration-free laser-induced breakdown spectroscopy (LIBS) as a powerful analytical tool for rapid and reliable quantitative spectrochemical characterizations of layered Li metal oxide cathodes containing Mo and Cr dopants (<5 atom %). Specifically, we employ the LIBS using an internal calibration methodology to establish the quantitative elemental ratios of major (Ni, Mn, Co) and trace dopant (Cr, Mo) transition metals to bulk Li contents in diverse cathode material samples such as LiNi 0.5 Mn 0.5 O 2 (NM-50/50), LiNi 0.33 Mn 0.33 Co 0.33 O 2 (NMC), LiNi 0.317 Mn 0.317 Co 0.317 Cr 0.05 O 2 (Cr-doped NMC), and LiNi 0.5– x /2 Mn 0.5– x /2 Mo x O 2 ( x = 0.03, 0.04, 0.05) (Mo-doped NM-50/50) that were synthesized via sol–gel routes. The LIBS-estimated elemental compositions are in good agreement with the nominal stoichiometric values. Furthermore, ex situ LIBS characterizations presented here pave the path for future high-efficacy application of calibration-free quantitative LIBS for rapid in situ analyses of elemental composition changes in battery electrode materials under operation that need not resort to off-site analytical techniques requiring cumbersome sample preparations and/or external standards.

25 ENERGY STORAGE↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

The effects of ultra-fine-grained structure and cryogenic temperature on adiabatic shear localization in titanium

The deformation at low temperatures (173 K and 77 K) in ultrafine-grained (100 and 500 nm) titanium is investigated and its effect on adiabatic shear localization is established. In comparison with coarse grained titanium, the strength of ultrafine-grained titanium is higher due to the classic Hall-Petch effect while the strain hardening approaches zero. Our results show that shear localization in dynamic deformation is also altered. The width of the shear band of coarse-grained titanium decreases from 30 to 18 mm (by 40%) with decreasing the initial deformation temperature to 77 K. In contrast, for 100 nm titanium, the width of shear band decreases more significantly, from 4 mmat room temperature to 1 mm (a 75% decrease) at 77 K. This difference is attributed to the combined effects of the decrease in the thermal conductivity and specific heat capacity, and the increase in thermal softening rate. These changes in the width are consistent with the predictions of the Grady and Bai-Dodd theories. Ultrafine- and nanorecrystallized grains are observed inside the bands which are dependent on initial grain size and initial deformation temperature. Here, the dislocation evolution is evaluated for the different conditions using a Kocks-Mecking formulation; the rotational dynamic recrystallization mechanism responsible for forming the ultrafine/nanosized grains (40-250 nm) is successfully modeled incorporating the differences in initial temperature and grain size. Our results and analysis are important in enhancing the understanding of the structural evolution processes under high strain-rates and cryogenic temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of High Energy Density Diaminocyclopropenium‐Phenothiazine Hybrid Catholytes for Non‐Aqueous Redox Flow Batteries

Abstract This report describes the design of diaminocyclopropenium‐phenothiazine hybrid catholytes for non‐aqueous redox flow batteries. The molecules are synthesized in a rapid and modular fashion by appending a diaminocyclopropenium (DAC) substituent to the nitrogen of the phenothiazine. Combining a versatile C‐N coupling protocol (which provides access to diverse derivatives) with computation and structure‐property analysis enabled the identification of a catholyte that displays stable two‐electron cycling at potentials of 0.64 and 1.00 V vs. Fc/Fc + as well as high solubility in all oxidation states (≥0.45 M in TBAPF 6 /MeCN). This catholyte was deployed in a high energy density two‐electron RFB, exhibiting >90 % capacity retention over 266 hours of flow cell cycling at >0.5 M electron concentration.

Yan, Yichao↗

Fluorinated Rocksalt Cathode with Ultra‐high Active Li Content for Lithium‐ion Batteries

Abstract The key to increasing the energy density of lithium‐ion batteries is to incorporate high contents of extractable Li into the cathode. Unfortunately, this triggers formidable challenges including structural instability and irreversible chemistry under operation. Here, we report a new kind of ultra‐high Li compound: Li 4+ x MoO 5 F x (1≤ x ≤3) for cathode with an unprecedented level of electrochemically active Li (>3 Li + per formula), delivering a reversible capacity up to 438 mAh g −1 . Unlike other reported Li‐rich cathodes, Li 4+ x MoO 5 F x presents distinguished structure stability to immunize against irreversible behaviors. Through spectroscopic and electrochemical techniques, we find an anionic redox‐dominated charge compensation with negligible oxygen release and voltage decay. Our theoretical analysis reveals a “reductive effect” of high‐level fluorination stabilizes the anionic redox by reducing the oxygen ions in pure‐Li conditions, enabling a facile, reversible, and high Li‐portion cycling.

Pei, Yi↗

Lead tolerance and bioremoval by four strains of green algae from Nigerian fish ponds

Heavy metals from industry pose threats to human and environmental health. Microalgae are prime candidates to remove heavy metals from water and soil due to their metal-binding affinities, high growth rates, and contamination tolerance. Strain selection and composition of resulting contaminated biomass must be considered for downstream processing. In this study, we assessed the ability of four microalgae strains (Chlorophyceae) that were isolated from contaminated Nigerian fish ponds to take up dissolved lead at environmentally relevant concentrations (<0.05 mg L -1 – WHO standard). In a microplate assay, all strains grew in the presence of lead, tolerating concentrations up to 60 ppm, though the addition of dissolved lead affected the growth of the four strains. In a photobioreactor assay, all strains demonstrated the ability to take up dissolved lead, with removal efficiencies ranging from 86 to 93%. The concentrations of lead in contaminated biomass, removal efficiencies, and bioconcentration factors were greatest in one of the isolates Chlorella sp. MOW 12. Our results reinforce the fact that live microalgae have a greater biosorption capacity. Lead recovery from freeze-dried biomass using five different reagents showed that a 0.1 M hydrochloric acid solution was the most effective, with 83.4% recovery. We also showed that presence of lead in the culture medium resulted in an increase in the quantity of protein in the biomass. Elemental analysis of lead-bound biomass showed an increase in elements including boron and copper and a decrease in cobalt and sodium. Synergystic and antagonystic effect in uptake of other elements was strain specific, suggesting the possibility of tailored wastewater treatments depending on specific requirements.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LaNi x Fe 1–x O 3 as flexible oxygen or carbon carriers for tunable syngas production and CO 2 utilization

The current study reports LaFe 1–x Ni x O 3–δ redox catalysts as flexible oxygen or carbon carriers for CO2 utilization and tunable production of syngas at relatively low temperatures (~700 °C), in the context of a hybrid redox process. Specifically, perovskite-structured LaFe 1–x Ni x O 3–δ with seven different compositions (x = 0.4–1) were prepared and investigated. Cyclic experiments under alternating methane and CO 2 flows indicated that all the samples exhibited favorable reactive performance: CH 4 and CO 2 conversions varied between 85% and 98% and 70–88%, respectively. While H 2 /CO ratio from Fe-rich redox catalysts was ~2.3:1 in the methane conversion step, Ni-rich catalysts produced a concentrated (~ 93.7 vol%) hydrogen stream via methane cracking. The flexibility of LaFe 1–x Ni x O 3–δ to produce syngas (or hydrogen) with tunable compositions was found to be governed by the iron/nickel (Fe/Ni) ratio. Redox catalysts with higher Fe contents act as a lattice oxygen carrier via chemical looping partial oxidation (CLPOx) of methane whereas those with higher Ni contents function as a carbon carrier via chemical looping methane cracking (CLMC) scheme. XRD analysis and temperature-programmed reactions revealed that both types of catalysts involve the formation of La 2 O 3 and Ni 0 /Ni-Fe phases under the methane environment. The ability to re-incorporate La 2 O 3 and Ni/Fe into a perovskite structure gives rise to oxygen-carrying capacity whereas stable Ni 0 or Ni/Fe phases would catalyze methane cracking without lattice oxygen exchange in the reaction cycles. Here, temperature programmed oxidation and Raman spectroscopy indicated the presence of graphitic and amorphous carbon species, which were effectively gasified by CO 2 to produce concentrated CO. Stability tests over LaFe 0.5 Ni 0.5 O 3 and LaNiO 3 revealed that the redox performance was stable over a span of 50 cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SMATool: Strength of materials analysis toolkit

The study of the strength of materials is a cornerstone in material science and engineering, playing a critical role in shaping the progress and application of materials in diverse industrial sectors. The strength of a material is meticulously examined to understand the behavior of the material under different stress conditions and environments, thereby guiding material selection and structural design. Herein, we introduce the SMATool, a computational toolkit for the efficient calculation and analysis of material strength at both zero and finite temperatures for 3D, 2D, 1D, and tubular 2D-based nanostructures and nanotubes, as well as 1D nanoribbons. The toolkit is capable of calculating tensile, shear, ultimate, yield, and indentation (Vickers' hardness) strengths in various dimensions, as well as the energy storage capacity. We conducted several calculations both at zero and finite temperatures to validate the accuracy and reliability of the developed software. Here, the results show that the SMATool package provides accurate predictions that align with existing data on material strength. SMATool integrates seamlessly with widely used electronic structure codes like VASP and Quantum Espresso, providing a user-friendly interface catering to academic researchers and industry professionals.

36 MATERIALS SCIENCE↗

Evaluating temperature dependent degradation mechanisms of silicon-graphite electrodes and the effect of fluoroethylene carbonate electrolyte additive

Understanding and overcoming the relatively high rate of degradation observed with silicon (Si)-based anodes in lithium (Li)-ion batteries (LiBs) is crucial for developing cells with increased energy density. The capacity fade of Si-graphite (Gr) electrodes in electrolytes with and without 10 wt% fluoroethylene carbonate (FEC) is explored during cycling at temperatures of 25, 45, and 70 °C, focusing on the complex degradation modes arising from loss of active material, loss of Li inventory, and cell resistance growth. We first show the common half-cell testing cannot be used at elevated temperatures as the performance of Li metal overshadows the behavior of Si-Gr electrode. Symmetric cell configuration successfully eliminates the effect of foreign materials, and reveals that while the presence of FEC provides better passivation of Si, it also results in greater parasitic reactions at 70 °C and faster capacity fade. The electrolyte without FEC, on the other hand, shows higher capacity retention at 70 °C. Finally, we propose a multi-step test protocol which can successfully deconvolute the information on loss of Li inventory and of active material. By combining half-cell and symmetric cell test methods, we demonstrate that loss of active material is reduced at higher temperatures and the dominant mechanisms of capacity loss for Si-Gr electrodes at elevated temperatures is loss of Li inventory.

25 ENERGY STORAGE↗

Human α-defensin 5 suppressed colon cancer growth by targeting PI3K pathway

Defensins are highly conserved antimicrobial peptides, which ubiquitously expressed in different species. In addition to the functions in host defense, their aberrant expression have also been documented in cancerous tissue including breast cancer, lung caner and renal carcinoma etc. Whereas, roles of Defensin Alpha 5 (DEFA5) in colon cancer has not been explored. Bioinformatic analysis was used to study the expression of DEFA5 and its correlation with clinical outcomes; Western blot, qPCR, Co-immunoprecipitation, xenograft models were used to the study the molecular mechanism. Decreased expression of DEFA5 at protein level was observed in colon tissues. Colon cancer cell lines proliferation and colony formation capacity were significantly suppressed by DEFA5 overexpression. Moreover, in vivo tumor growth in nude mice was also suppressed by DEFA5 overexpression, suggesting a tumor suppressor role of DEFA5 in colon cancer. Mechanistically, DEFA5 directly binds to the subunits of PI3K complex, thus attenuates the downstream signaling transduction, leads to delayed cell growth and metastasis. Collectively, we concluded that DEFA5 showed an inhibitory effect in colon cancer cell growth and may serve as a potential tumor suppressor in colon cancer.

60 APPLIED LIFE SCIENCES↗

Electronic Structure and Safety Insights into Prussian Blue Analog Cathode Behavior at Elevated Temperatures in Sodium-Ion Batteries

Prussian blue analogs (PBAs) represent promising cathode materials for sodium-ion batteries (SIBs) due to their high theoretical capacity, open framework structure, and use of earth-abundant elements. However, the high-temperature structural evolution, water content effects, and thermal safety of PBAs, particularly in charged states, remain poorly understood, hindering their practical deployment. Here, we investigate Na 2 Fe[Fe(CN) 6 ]·2H 2 O using thermogravimetric analysis (TGA), ex situ and in situ temperature-dependent X-ray absorption spectroscopy (XAS), and accelerated rate calorimetry (ARC). TGA and ex situ XAS confirm water loss between 150 and 200 °C, resulting in Fe 2+ oxidation, enhanced local symmetry, and uniform redox behavior that improves electrochemical performance. In situ XAS reveals irreversible structural changes above 240 °C, including ligand loss, Fe site distortion, and increased disorder, while ARC on charged electrodes shows minimal self-heating rates (<0.1 °C/min) up to 300 °C, indicating exceptional thermal stability without lattice oxygen release. These insights elucidate PBA thermal dynamics, demonstrating improved electrochemical performance of water-deficient PBAs and informing future material design and safety assessment for SIB applications.

batteries↗