Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

The compact neutron spectrometer at ASDEX Upgrade

The first neutron spectrometer of ASDEX Upgrade (AUG) was installed in November 2008. It is a compact neutron spectrometer (CNS) based on a BC501A liquid scintillating detector, which can simultaneously measure 2.45-MeV and 14-MeV neutrons emitted from deuterium (D) plasmas and {gamma} radiation. The scintillating detector is coupled to a digital pulse shape discrimination data acquisition (DPSD) system capable of count rates up to 10{sup 6} s{sup -1}. The DPSD system can operate in acquisition and processing mode. With the latter n-{gamma} discrimination is performed off-line based on the two-gate method. The paper describes the tests of the CNS and its installation at AUG. The neutron emission from the D plasma measured during a discharge with high auxiliary heating power was used to validate the CNS performance. The study of the optimal settings for the DPSD data processing to maximize the n-{gamma} discrimination capability of the CNS is reported. The CNS measured both 2.45-MeV and 14-MeV neutrons emitted in AUG D plasmas with a maximum count rate of 5.4 x10{sup 5} s{sup -1} (>10 times higher than similar spectrometers previously achieved) with an efficiency of 9.3 x 10{sup -10} events per AUG neutron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of compact linear accelerator in KBSI

The compact linear accelerator using a 28 GHz ECRIS is under construction in KBSI, South Korea. The main capability of this facility is the production of fast neurons for the neutron radiography. The designing of a superconducting magnet, microwave transmission system, beam extraction, and plasma chamber of ECRIS were finished. The nominal axial design fields of the magnets are 3.6 T at injection and 2.2 T at extraction; the nominal radial design field strength at the plasma chamber wall is 2.1 T. We already installed 10 kW, 28 GHz gyrotron, and tested a microwave power from gyrotron using a dummy load. The current status will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Technical use of compact micro-onde devices

Due to the very small size of a COMIC (Compact MIcrowave and Coaxial) device [P. Sortais, T. Lamy, J. Medard, J. Angot, L. Latrasse, and T. Thuillier, Rev. Sci. Instrum. 81, 02B31 (2010)] it is possible to install such plasma or ion source inside very different technical environments. New applications of such a device are presented, mainly for industrial applications. We have now designed ion sources for highly focused ion beam devices, ion beam machining ion guns, or thin film deposition machines. We will mainly present new capabilities opened by the use of a multi-beam system for thin film deposition based on sputtering by medium energy ion beams. With the new concept of multi-beam sputtering (MBS), it is possible to open new possibilities concerning the ion beam sputtering (IBS) technology, especially for large size deposition of high uniformity thin films. By the use of multi-spots of evaporation, each one corresponding to an independent tuning of an individual COMIC ion source, it will be very easy to co-evaporate different components.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact microwave ion source for industrial applications

A 2.45 GHz microwave ion source for ion implanters has many good properties for industrial application, such as easy maintenance and long lifetime, and it should be compact for budget and space. But, it has a dc current supply for the solenoid and a rf generator for plasma generation. Usually, they are located on high voltage platform because they are electrically connected with beam extraction power supply. Using permanent magnet solenoid and multi-layer dc break, high voltage deck and high voltage isolation transformer can be eliminated, and the dose rate on targets can be controlled by pulse duty control with semiconductor high voltage switch. Because the beam optics does not change, beam transfer components, such as focusing elements and beam shutter, can be eliminated. It has shown the good performances in budget and space for industrial applications of ion beams.

43 PARTICLE ACCELERATORS↗

A very low energy compact electron beam ion trap for spectroscopic research in Shanghai

In this paper, a new compact low energy electron beam ion trap, SH-PermEBIT, is reported. This electron beam ion trap (EBIT) can operate in the electron energy range of 60-5000 eV, with a current density of up to 100 A/cm{sup 2}. The low energy limit of this machine sets the record among the reported works so far. The magnetic field in the central drift tube region of this EBIT is around 0.5 T, produced by permanent magnets and soft iron. The design of this EBIT allows adjustment of the electron gun's axial position in the fringe field of the central magnetic field. This turned out to be very important for optimizing the magnetic field in the region of the electron gun and particularly important for low electron beam energy operation, since the magnetic field strength is not tunable with permanent magnets. In this work, transmission of the electron beam as well as the upper limit of the electron beam width under several conditions are measured. Spectral results from test operation of this EBIT at the electron energies of 60, 315, 2800, and 4100 eV are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration of a compact high efficient relativistic magnetron with directly axial radiation

A compact relativistic magnetron with axial microwave radiation is experimentally investigated. Under the modified magnetic field distribution, only connecting a special horn antenna in the axial direction, the relativistic magnetron can stably radiate high power and high efficiency microwaves. The total length of the device is {approx}0.3 m, and the volume is {approx}0.014m{sup 3}. In such working condition that the applied voltage is 539 kV and the magnetic field is {approx}0.38 T, the output microwave power is {approx}1.24 GW. Correspondingly, the total efficiency is about 34.1%. The radiating frequency is 2.35GHz, which is in agreement with the {pi} mode frequency of the theoretical expectation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact filament-discharge multi-cusp H{sup -} ion source

A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H{sup -} ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H{sup -} ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA/25 keV H{sup -} beam with an emittance of 0.3 {pi} mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.

43 PARTICLE ACCELERATORS↗

Compact cryogenic source of periodic hydrogen and argon droplet beams for relativistic laser-plasma generation

We present a cryogenic source of periodic streams of micrometer-sized hydrogen and argon droplets as ideal mass-limited target systems for fundamental intense laser-driven plasma applications. The highly compact design combined with a high temporal and spatial droplet stability makes our injector ideally suited for experiments using state-of-the-art high-power lasers in which a precise synchronization between the laser pulses and the droplets is mandatory. We show this by irradiating argon droplets with multi-terawatt pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tuneable ultra-compact high-power, ultra-short pulsed, bright gamma-ray source based on bremsstrahlung radiation from laser-plasma accelerated electrons

The laser driven plasma wakefield accelerator is a very compact source of high energy electrons. When the quasi-monoenergetic beam from these accelerators passes through dense material, high energy bremsstrahlung photons are emitted in a collimated beam with high flux. We show how a source based on this emission process can produce more than 10{sup 9} photons per pulse with a mean energy of 10 MeV. We present experimental results that show the feasibility of this method of producing high energy photons and compare the experimental results with GEANT4 Montecarlo simulations, which also give the scaling required to evaluate its suitability as method to produce radioisotopes via photo-nuclear reactions or for imaging applications.

07 ISOTOPE AND RADIATION SOURCES↗

Compact 'diode-based' multi-energy soft x-ray diagnostic for NSTX

A novel and compact, diode-based, multi-energy soft x-ray (ME-SXR) diagnostic has been developed for the National Spherical Tokamak Experiment. The new edge ME-SXR system tested on NSTX consists of a set of vertically stacked diode arrays, each viewing the plasma tangentially through independent pinholes and filters providing an overlapping view of the plasma midplane which allows simultaneous SXR measurements with coarse sub-sampling of the x-ray spectrum. Using computed x-ray spectral emission data, combinations of filters can provide fast (>10 kHz) measurements of changes in the electron temperature and density profiles providing a method to 'fill-in' the gaps of the multi-point Thomson scattering system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment

A three-channel 1 mm wave interferometer has been designed, assembled, and installed on the Compact Toroidal Hybrid torsatron (CTH). The interferometer design makes novel use of a subharmonic mixer for detection, which simplifies alignment. It employs a single electronically tunable source that is repetitively chirped using a sawtooth waveform of frequency up to 1 MHz. The 15.25 GHz drive oscillator is multiplied in two stages to 122 GHz before a final doubler stage brings it to 244 GHz. Local oscillator (LO) power at 122 GHz is directed through waveguide to the LO input of the subharmonic mixer of each viewing chord, simplifying alignment. Phase detection is performed by directly digitizing the amplified mixer outputs at 50 MHz and processing them with a software algorithm. Initial measurements made with the central chord of the new interferometer agree with those from the existing 4 mm system at low densities. The 1 mm system performs well in current-driven discharges reaching densities over 10{sup 19} m{sup -3}, whereas the lower frequency interferometer is found to be less reliable due to loss of fringes. This is a critical improvement for experiments studying the onset, avoidance, and vacuum magnetic transform dependence of disruptions in the CTH device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in compact proton spectrometers for inertial-confinement fusion and plasma nuclear science

Compact wedge-range-filter proton spectrometers cover proton energies {approx}3-20 MeV. They have been used at the OMEGA laser facility for more than a decade for measuring spectra of primary D{sup 3}He protons in D{sup 3}He implosions, secondary D{sup 3}He protons in DD implosions, and ablator protons in DT implosions; they are now being used also at the National Ignition Facility. The spectra are used to determine proton yields, shell areal density at shock-bang time and compression-bang time, fuel areal density, and implosion symmetry. There have been changes in fabrication and in analysis algorithms, resulting in a wider energy range, better accuracy and precision, and better robustness for survivability with indirect-drive inertial-confinement-fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact multichannel spectrometer for Thomson scattering

The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact Kirkpatrick–Baez microscope mirrors for imaging laser-plasma x-ray emission

Compact Kirkpatrick–Baez microscope mirror components for use in imaging laser-plasma x-ray emission have been manufactured, coated, and tested. A single mirror pair has dimensions of 14 × 7 × 9 mm and a best resolution of ~5 μm. The mirrors are coated with Ir providing a useful energy range of 2-8 keV when operated at a grazing angle of 0.7°. The mirrors can be circularly arranged to provide 16 images of the target emission a configuration best suited for use in combination with a custom framing camera. As a result, an alternative arrangement of the mirrors would allow alignment of the images with a fourstrip framing camera.

47 OTHER INSTRUMENTATION↗

Photo-fusion reactions in a new compact device for ELI

In the last few years significant progress on technological, experimental and numerical studies on fusion process in high density and high temperature plasmas produced by a high intensity laser pulse interaction with clusters in a high external applied magnetic field, enable us to propose a compact photo-fusion magnetic device for high neutron production. For the purpose of the project a pulsed magnetic field driver with values up to 110 Tesla has been developed which allows increasing the trapping time of the high density plasma in the device and improving the neutron yield. Numerical simulations show that the proposed device is capable of producing up to 10{sup 9}-10{sup 10} neutrons per laser shot with an external magnetic field of 150 Tesla. The proposed device can be used for experiments and numerical code validation concerning different conventional and (or) exotic fusion fuels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact steady-state and high-flux Falcon ion source for tests of plasma-facing materials

This paper describes the design and operation of the Falcon ion source. It is based on conventional design of anode layer thrusters. This ion source is a versatile, compact, affordable, and highly functional in the research field of the fusion materials. The reversed magnetic field configuration of the source allows precise focusing of the ion beam into small spot of Almost-Equal-To 3 mm and also provides the limited capabilities for impurity mass-separation. As the result, the source generates steady-state ion beam, which irradiates surface with high heat (0.3 - 21 MW m{sup -2}) and particle fluxes (4 Multiplication-Sign 10{sup 21}- 3 Multiplication-Sign 10{sup 23} m{sup -2}s{sup -1}), which approaches the upper limit for the flux range expected in ITER.

43 PARTICLE ACCELERATORS↗

Sensitivity in X-ray grating interferometry on compact systems

The optimization of compact X-ray grating interferometry systems is crucial for the progress of this technique in industrial devices. Here, an analytical formulation for the sensitivity of the phase contrast image acquisition is derived using previous results from noise analyses. Furthermore, experimental measurements of the sensitivity for different configurations are compared, providing further insight into the dependence on polychromatic radiation. Finally, strategies for the geometrical optimization are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of a compact P-band coaxial relativistic backward wave oscillator with three periods slow wave structure

A compact P-band coaxial relativistic backward wave oscillator with three periods slow wave structure was investigated experimentally. The experimental results show that the frequency of the P-band coaxial relativistic backward wave oscillator is 897 MHz and the microwave power is 1.47 GW with an efficiency of about 32% in the case in which the diode voltage is 572 kV, the beam current is 8.0 kA, and the guide magnetic field is about 0.86 T. In addition, the device can generate a 3.14 GW microwave radiation as the guide magnetic field increases to 1.2 T at the diode voltage of 997 kV and the beam current of 15.3 kA. The experimental results are in good agreement with those obtained earlier by numerical simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗