Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Development of an x-ray imaging system for the Laser Megajoule (LMJ)

This imaging system aims at recording images of the core size and shape of an imploding deuterium-tritium (DT) microballoon on LMJ inertial confinement fusion (ICF) experiments. Image acquisition is difficult due to the harsh surrounding created by the fusion reaction, which affects system specifications. This one is made of a scintillator, an optical relay, and a CCD camera shielded from the surrounding. The system was tested on different facilities at CEA/DIF, where a spatial resolution of 120 {mu}m was achieved and gamma dose up to 20 rad effects were measured. Setup and performed test are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of fast (sub-minute) micro-tomography

An x-ray fast micro-tomography system was developed at medical and imaging beamline BL20B2 in SPring-8. We attempted a 'continuous rotation method' whereby the sample keeps rotating in the beam during the measurement. The image acquisitions are synchronized with the trigger pulses branched from the stepper motor controller. An electron multiplier (EM)-CCD camera (C9100-02, 1000x1000 pixels, 30 fps, 8 {mu}m/pixel, Hamamatsu Photonics) and beam-monitor AA40P (Hamamatsu Photonics) were used as an image detector. The effective pixel size of the detector was 4.9 {mu}m/pixel and the spatial resolution was about 15 {mu}m. The total measurement time for 900 projections has been reduced to 36 s. The reconstruction time was also reduced using GPGPU and SSD system. Using these techniques, preliminary experiment for 4-D (time resolved 3-D) micro-imaging has also been performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grazing incidence wide angle x-ray scattering at the wiggler beamline BW4 of HASYLAB

We present an upgrade of the available measurement techniques at the wiggler beamline BW4 of the Hamburger Synchrotronstrahlungslabor (HASYLAB) to grazing incidence wide angle x-ray scattering (GIWAXS). GIWAXS refers to an x-ray diffraction method, which, based on the measurement geometry, is perfectly suited for the investigation of the material crystallinity of surfaces and thin films. It is shown that the overall experimental GIWAXS setup employing a movable CCD-detector provides the capability of reliable and reproducible diffraction measurements in grazing incidence geometry. Furthermore, the potential usage of an additional detector enables the simultaneous or successive measurement of GIWAXS and grazing incidence small angle x-ray scattering (GISAXS). The new capability is illustrated by the microbeam GIWAXS measurement of a thin film of the conjugated polymer poly(3-octylthiophene) (P3OT). The investigation reveals the semicrystalline nature of the P3OT film by a clear identification of the wide angle scattering reflexes up to the third order in the [100]-direction as well as the first order in the [010]-direction. The corresponding microbeam GISAXS measurement on the present morphology complements the characterization yielding the complete sample informa-tion from subnanometer up to micrometer length scales.

36 MATERIALS SCIENCE↗

Application of beam emission spectroscopy to NBI plasmas of Heliotron J

This paper describes the application of the beam emission spectroscopy (BES) to Heliotron J, having the nonsymmetrical helical-magnetic-axis configuration. The spectral and spatial profile of the beam emission has been estimated by the numerical calculation taking the collisional excitation processes between plasmas (electrons/ions) and beam atoms. Two sets of the sightlines with good spatial resolution are presented. One is the optimized viewing chords which have 20 sightlines and observe the whole plasma region with the spatial resolution {Delta}{rho} less than {+-}0.055 using the newly designed viewing port. The other is 15 sightlines from the present viewing port of Heliotron J for the preliminary measurement to discuss the feasibility of the density fluctuation measurement by BES. The beam emission has been measured by a monochromator with a CCD camera. A good consistency has been obtained between the spectral profiles of the beam emission measured by the monochromator and the beam emission spectrum deduced by the model calculation. An avalanche photodiode with an interference filter system was also used to evaluate the signal-to-noise (S/N) ratio of the beam emission in the present experimental setup. The modification of the optical system is being planned to improve the S/N ratio, which will enable us to estimate the density fluctuation in Heliotron J.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Parallel Image Detection System Using Annular Pupils for Scanning Transmission Electron Microscope

A parallel image detection system using an annular pupil for electron optics were developed to realize an increase in the depth of focus, aberration-free imaging and separation of amplitude and phase images under scanning transmission electron microscopy (STEM). Apertures for annular pupils able to suppress high-energy electron scattering were developed using a focused ion beam (FIB) technique. The annular apertures were designed with outer diameter of oe 40 {mu}m and inner diameter of oe32 {mu}m. A taper angle varying from 20 deg. to 1 deg. was applied to the slits of the annular apertures to suppress the influence of high-energy electron scattering. Each azimuth angle image on scintillator was detected by a multi-anode photomultiplier tube assembly through 40 optical fibers bundled in a ring shape. To focus the image appearing on the scintillator on optical fibers, an optical lens relay system attached with CCD camera was developed. The system enables the taking of 40 images simultaneously from different scattered directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a full profile sub-cm ruby laser based Thomson scattering system for MAST

A major upgrade to the ruby Thomson scattering (TS) system has been designed and implemented on the Mega-ampere spherical tokamak (MAST). MAST is equipped with two TS systems, a Nd:YAG laser system and a ruby laser system. Apart from common collection optics each system provides independent measurements of the electron temperature and density profile. This paper focuses on the recent upgrades to the ruby TS system. The upgraded ruby TS system measures 512 points across the major radius of the MAST vessel. The ruby laser can deliver one 10 J 40 ns pulse at 1 Hz or two 5 J pulses separated by 100-800 {mu}s. The Thomson scattered light is collected at F/15 over 1.4 m. This system can resolve small (7 mm) structures at 200 points in both the electron temperature and density channels at high optical contrast; {approx}50% modulated transfer function. The system is fully automated for each MAST discharge and requires little adjustment. The estimated measurement error for a 7 mm radial point is <4% of T{sub e} and <3% of n{sub e} in the range of 40 eV to 2 keV, for a density of n{sub e}=2x10{sup 19} m{sup -3}. The photon statistics at lower density can be increased by binning in the radial direction as desired. A new intensified CCD camera design allows the ruby TS system to take two snapshots separated with a minimum time of 230 {mu}s. This is exploited to measure two density and temperature profiles or to measure the plasma background light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fizeau interferometer system for fast high resolution studies of spectral line shapes

A monochromator/Fizeau interferometer/intensified CCD camera system is described that was developed for the measurement of the shape of spectral lines that are rapidly time varying. The most important operating parameter that determines the performance of the instrument is the size of the entrance aperture as this determines both the light throughput and the effective interferometer wavelength resolution. This paper discusses, both theoretically and experimentally, the effect of the finite source area on the instrumental resolution to assist in optimizing the choice of this parameter. A second effect that often produces a practical limit to the quality of the spectra is drift of the interferometer plates. Measurements of the shapes of spectral lines of ions and atoms ejected from the cathode spot of continuous and pulsed cathodic arcs are presented to demonstrate the utility of this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on ultra-fine w-EDM with on-machine measurement-assisted

The purpose of this study was to develop the on-machine measurement techniques so as to precisely fabricate micro intricate part using ultra-fine w-EDM. The measurement-assisted approach which employs an automatic optical inspection (AOI) is incorporated to ultra-fine w-EDM process to on-machine detect the machining error for next re-machining. The AOI acquires the image through a high resolution CCD device from the contour of the workpiece after roughing in order to further process and recognize the image for determining the residual. This facilitates the on-machine error detection and compensation re-machining. The micro workpiece and electrode are not repositioned during machining. A fabrication for a micro probe of 30-{mu}m diameter is rapidly machined and verified successfully. Based on the proposed technique, on-machine measurement with AOI has been realized satisfactorily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral-domain phase microscopy with improved sensitivity using two-dimensional detector arrays

In this work we demonstrate the use of two-dimensional detectors to improve the signal-to-noise ratio (SNR) and sensitivity in spectral-domain phase microscopy for subnanometer accuracy measurements. We show that an increase in SNR can be obtained, from 82 dB to 105 dB, using 150 pixel lines of a low-cost CCD camera as compared to a single line, to compute an averaged axial scan. In optimal mechanical conditions, phase stability as small as 92 {mu}rad, corresponding to 6 pm displacement accuracy, could be obtained. We also experimentally demonstrate the benefit of spatial-averaging in terms of the reduction of signal fading due to an axially moving sample. The applications of the improved system are illustrated by imaging live cells in culture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Pleiades Using Astronomical Spectroscopic Technique within the Range of H-{alpha} Region

The Pleiades is an open star cluster located in the constellation of Taurus, which mainly consists of hot and luminous B-type stars. Observations were conducted over five-day period in December 2009 at Langkawi National Observatory, Malaysia by using 20-inch telescope diameter of Ritchey-Chretien reflector telescope, together with SBIG Self Guided Spectrograph and SBIG ST-7 CCD camera. The spectra of seven main members of the cluster, namely Alcyone; Atlas; Celaeno; Electra; Maia; Merope and Taygeta; and of Alcyone B; a smaller component of Alcyone quadruple system, were obtained in the optical range of approximately 6300 A to 7100 A. This range was picked due to the vicinity of Balmer H-{alpha} spectral line at 6562.852 A. Alcyone, Electra and Merope were found to have H-{alpha} emissions possibly caused by the presence of equatorial circumstellar disks or envelopes made up of ejected matter. Electra and Merope in particular exhibited peculiar asymmetric double emission peaks, which could be evidence of one-armed density wave in each of their circumstellar disks. Atlas, Celaeno, Merope, Taygeta and Alcyone B showed strong H-{alpha} absorptions with broadening characteristic of high rotational velocities. As deduced from the spectra, the stars were found to have atmospheres with similar chemical content, with spectral lines characteristics of singly ionized silicon, singly ionized iron and singly ionized oxygen. The measured radial velocities of all eight stars also suggest that the cluster could someday disperse.

79 ASTRONOMY AND ASTROPHYSICS↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional space resolving flat-field holographic grating soft x-ray framing camera spectrograph for laser plasma diagnostics

A 1D space resolving x-ray spectrum diagnostic system has been developed to study the radiation opacity of hot plasma on SG-II laser facility. The diagnostic system consists of a 2400 lines/mm flat-field holographic grating and a gated microchannel plate coupled with an optical CCD and covers the wavelength range of 5-50 A. The holographic grating was compared with a ruled one by measuring the emission spectra from a laser-produced molybdenum plasma. The results indicate that the holographic grating possesses better sensitivity than the ruled grating having nearly similar spectral resolution. The spectrograph has been used in radiative opacity measurement of Fe plasma. Simultaneous measurements of the backlight source and the transmission spectrum in appointed time range in one shot have been accomplished successfully with the holographic grating spectrometer. The 2p-3d transition absorption of Fe plasma near 15.5A in has been observed clearly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal structure of 0.9 GHz microplasma

Argon microplasmas generated at 0.9 GHz by a split-ring resonator form a single filament-shaped nonequilibrium glow discharge. The internal structure of these microplasmas is probed using laser diode absorption and imaging emission spectrometry. These two-dimensional diagnostics are then Abel inverted to reveal that the core of the filament has a strongly depleted central metastable argon population. The microdischarges are approximately 0.2 mm in width at 1 atm and expand with increasing input power between 0.05-1.5 W. The relative electron density and the Ar(4p) density are estimated from the emission detected by a CCD camera through various bandpass filters. Absolute Ar(4s) densities, on the other hand, are determined by Ar 801.4 nm absorption. The Ar(4s) profile transitions from center-peaked at low power (0.05 W) to center-depleted above 0.25 W, saturating at 10{sup 19} m{sup -3}. The electron density profile within the microplasma, however, remains center-peaked regardless of the power. The spatially-resolved gas temperature was estimated from the broadening of the Ar 801.4 nm absorption profile. The error in this gas temperature measurement due to the depletion of the metastable atoms is corrected using numerical heat transfer models and shown to be 1650 K if the plasma power is 1.2 W. Differences between the peak and average temperatures based on the nitrogen rotational spectrum are also explained using nitrogen emission imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aplanatic Three-Mirror Objective for High-Magnification Soft X-Ray Microscopy

An innovative solution for high-magnification microscopy, based on attaching afocal optics for focal length reduction, is proposed. The solution, consisting of three spherical mirrors, allows one to enhance a magnification of a laboratory based soft x-ray microscope over 1000x, where movies with diffraction-limited resolution can be observed with an x-ray CCD. The design example, having a numerical aperture of 0.25, was successfully demonstrated both a high magnification and a large field of view.

07 ISOTOPE AND RADIATION SOURCES↗

Angle-resolved cathodoluminescence spectroscopy

We present a cathodoluminescence spectroscopy technique which combines deep subwavelength excitation resolution with angle-resolved detection capabilities. The cathodoluminescence emission is collected by a paraboloid mirror (effective NA = 0.96) and is projected onto a 2D CCD array. The azimuthal and polar emission pattern is directly deduced from the image. As proof of principle, we use the technique to measure the angular distribution of transition radiation from a single crystalline gold surface under 30 keV electron irradiation. We find that the experiment matches very well with theory, illustrating the potential of this technique for the characterization of photonic structures with deep subwavelength dimensions.

36 MATERIALS SCIENCE↗

Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use

Solid Nuclear Track Detectors (SNTDs), CR-39 type, are usually adopted to monitor radon gas concentrations. In order to characterize the detectors according to track geometrical parameters, detectors were irradiated inside a vacuum chamber by alpha particles at twelve energy values, obtained by different Mylar foils in front of a {sup 241}Am source. The alpha energy values were verified using a Si detector. After the exposure to the alpha particles, the detectors were chemically etched to enlarge the tracks, which were then analyzed by means of a semiautomatic system composed of an optical microscope equipped with a CCD camera connected to a personal computer to store images. A suitable routine analyzed the track parameters: major and minor axis length and mean grey level, allowing us to differentiate tracks according to the incident alpha energy and then to individuate the discrimination factors for radon alpha tracks. The combined use of geometrical and optical parameters allows one to overcome the ambiguity in the alpha energy determination due to the non-monotonicity of each parameter versus energy. After track parameter determination, a calibration procedure was performed by means of a radon chamber. The calibration was verified through an inter-comparing survey.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of self-generated magnetic fields in laser produced plasmas using a three-channel polaro-interferometer

Self-generated magnetic fields produced in laser plasmas at moderate laser intensities have been measured using a three-channel polaro-interferometer. The main elements of this device are two birefringent calcite wedges placed between two crossed polarizers. Using this device, the spatial profiles of (a) the rotation angle (polarometry), (b) the electron density (interferometry), and (c) the transmitted probe beam intensity (shadowgraphy) are recorded simultaneously using a digital camera with a large format CCD in a single laser shot. Magnetic fields of 2-4 MG had been estimated in aluminum plasma at laser intensities {approx}10{sup 13} W/cm{sup 2}. It is also possible to use this device in other configurations to get time resolved information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high accuracy femto-/picosecond laser damage test facility dedicated to the study of optical thin films

A laser damage test facility delivering pulses from 100 fs to 3 ps and designed to operate at 1030 nm is presented. The different details of its implementation and performances are given. The originality of this system relies the online damage detection system based on Nomarski microscopy and the use of a non-conventional energy detection method based on the utilization of a cooled CCD that offers the possibility to obtain the laser induced damage threshold (LIDT) with high accuracy. Applications of this instrument to study thin films under laser irradiation are presented. Particularly the deterministic behavior of the sub-picosecond damage is investigated in the case of fused silica and oxide films. It is demonstrated that the transition of 0-1 damage probability is very sharp and the LIDT is perfectly deterministic at few hundreds of femtoseconds. The damage process in dielectric materials being the results of electronic processes, specific information such as the material bandgap is needed for the interpretation of results and applications of scaling laws. A review of the different approaches for the estimation of the absorption gap of optical dielectric coatings is conducted and the results given by the different methods are compared and discussed. The LIDT and gap of several oxide materials are then measured with the presented instrument: Al{sub 2}O{sub 3}, Nb{sub 2}O{sub 5}, HfO{sub 2}, SiO{sub 2}, Ta{sub 2}O{sub 5}, and ZrO{sub 2}. The obtained relation between the LIDT and gap at 1030 nm confirms the linear evolution of the threshold with the bandgap that exists at 800 nm, and our work expands the number of tested materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗