Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

A continuous calibration of the ATLAS flavour-tagging classifiers via optimal transportation maps

A calibration of the ATLAS flavour-tagging algorithms using a new calibration procedure based on optimal transportation maps is presented. Simultaneous, continuous corrections to the b-jet, c-jet, and light-flavour jet classification probabilities from jet-tagging algorithms in simulation are derived for b-jets using $t\bar{t} \rightarrow e\mu \nu \nu bb$ data. After application of the derived calibration maps, closure between simulation and observation is achieved for jet flavour observables used in ATLAS analyses of Large Hadron Collider (LHC) Run 2 proton-proton collision data. This continuous calibration opens up new possibilities for the future use of jet flavour information in LHC analyses and also serves as a guide for deriving high-dimensional corrections to simulation via transportation maps, an important development for a broad range of inference tasks.

Aad, G. [Aix-Marseille Université] (ORCID:00000002↗

Jet energy calibration at the LHC

In this study, jets are one of the most prominent physics signatures of high energy proton–proton (p–p) collisions at the Large Hadron Collider (LHC). They are key physics objects for precision measurements and searches for new phenomena. This review provides an overview of the reconstruction and calibration of jets at the LHC during its first Run. ATLAS and CMS developed different approaches for the reconstruction of jets, but use similar methods for the energy calibration. ATLAS reconstructs jets utilizing input signals from their calorimeters and use charged particle tracks to refine their energy measurement and suppress the effects of multiple p–p interactions ( pileup ). CMS, instead, combines calorimeter and tracking information to build jets from particle flow objects. Jets are calibrated using Monte Carlo (MC) simulations and a residual in situ calibration derived from collision data is applied to correct for the differences in jet response between data and Monte Carlo.

43 PARTICLE ACCELERATORS↗

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗

Microsimulation model calibration using incremental mixture approximate Bayesian computation

Microsimulation models (MSMs) are used to inform policy by predicting population-level outcomes under different scenarios. MSMs simulate individual-level event histories that mark the disease process (such as the development of cancer) and the effect of policy actions (such as screening) on these events. MSMs often have many unknown parameters; calibration is the process of searching the parameter space to select parameters that result in accurate MSM prediction of a wide range of targets. We develop Incremental Mixture Approximate Bayesian Computation (IMABC) for MSM calibration which results in a simulated sample from the posterior distribution of model parameters given calibration targets. IMABC begins with a rejection-based ABC step, drawing a sample of points from the prior distribution of model parameters and accepting points that result in simulated targets that are near observed targets. Next, the sample is iteratively updated by drawing additional points from a mixture of multivariate normal distributions and accepting points that result in accurate predictions. Posterior estimates are obtained by weighting the final set of accepted points to account for the adaptive sampling scheme. We demonstrate IMABC by calibrating CRC-SPIN 2.0, an updated version of a MSM for colorectal cancer (CRC) that has been used to inform national CRC screening guidelines.

97 MATHEMATICS AND COMPUTING↗

Calibration of V-Notch and Compound Weirs for Subsurface Drainage Water Level Control Structures

Highlights Accurate discharge estimation is important when evaluating edge-of-field conservation practices. V-notch weir equations were developed for three sizes of subsurface drainage water level control structures. Compound weir equations were developed for subsurface drainage water level control structures. The compound weir equation accurately estimates discharge for flows within and overtopping the V-notch. Abstract.Numerous edge-of-field conservation practices use subsurface drainage water level control structures to monitor water levels and estimate discharge. In a control structure, procedures for calculating discharge when flow depth (head) exceeds the V-notch depth and overflows in the rectangular portion of the compound weir (CW) are ambiguous. In this study, we developed calibration equations for V-notch weirs in Agri Drain inline water level control structures of different sizes for flows within the V-notch and overtopping flow events. The discharge equation for overtopping events (Q CW , L s -1 ) was determined as: Q CW = a 1 (h b1 -h 1 b1 )+a 2 (W e -W v )h 1 b2 , where h and h 1 are heads above vertex/bottom and top of V-notch (cm), respectively, W is the effective crest width of rectangular weir (cm), W v is the top width of V-notch (cm), a 1 and b 1 are parameters for V-notch weir obtained by calibration, and a 2 and b 2 are calibration parameters for rectangular weir obtained from literature. Results were compared with a weir equation available in the literature (Q V+R ), which combines a V-notch equation with a head equal to V-depth and a rectangular weir equation for flow above V-depth. Discharge at overflow was estimated with high accuracy with Q CW, whereas Q V+R underestimated discharge (e.g., PBIAS of 0.67% vs. 17.82% for a 15.2 cm structure). An example using Q V+R resulted in a 14% lower annual estimation of nitrate-N load diverted to a saturated buffer than Q CW due to underestimation of drainage discharge during overflow events. Results suggest that the developed equation (Q CW ) accurately estimates discharge and will thus improve the estimated N load compared to Q V+R . Keywords: Compound weir, Flow monitoring, Subsurface drainage, V-notch weir, Water level control structure, Weir calibration.

Agriculture↗

Absolute calibration of optical streak cameras on picosecond time scales using supercontinuum generation

Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Calibration Including Time Delay Estimation for GNSS/INS-Assisted Pushbroom Scanners Onboard UAV Platforms

Unmanned aerial vehicles (UAVs ) equipped with imaging sensors and integrated global navigation satellite system/inertial navigation system (GNSS/INS ) units are used for numerous applications. Deriving reliable 3D coordinates from such UAVs is contingent on accurate geometric calibration, which encompasses the estimation of mounting parameters and synchronization errors. Through a rigorous impact analysis of such systematic errors, this article proposes a direct approach for spatial and temporal calibration (estimating system parameters through a bundle adjustment procedure) of a GNSS/INS -assisted pushbroom scanner onboard a UAV platform. The calibration results show that the horizontal and vertical accuracies are within the ground sampling distance of the sensor. Unlike for frame camera systems, this article also shows that the indirect approach is not a feasible solution for pushbroom scanners due to their limited ability for decoupling system parameters. This finding provides further support that the direct approach is recommended for spatial and temporal calibration of UAV pushbroom scanner systems.

47 OTHER INSTRUMENTATION↗

Hadron Monitor Calibration System for NuMI

NuMI (Neutrinos at Main Injector) beamline at Fermi National Accelerator Laboratory provides neutrinos to various neutrino experiments. The hadron monitor consisting of a 5 by 5 array of ionization chambers is part of the diagnostics for the beamline. In order to calibrate the hadron monitor, a gamma source is needed. We present the status and progress of the development of the calibration system for the hadron monitor. The system based on Raspberry Pi controlled CNC system, motors, and position sensors would allow us to place the gamma source precisely to calibrate the signal gain of individual pixels. The ultimate outcome of the study is a prototype of the calibration system.

43 PARTICLE ACCELERATORS↗

Bayesian calibration of the Community Land Model using surrogates

We present results from the Bayesian calibration of hydrological parameters of the Community Land Model (CLM), which is often used in climate simulations and Earth system models. A statistical inverse problem is formulated for three hydrological parameters, conditional on observations of latent heat surface fluxes over 48 months. Our calibration method uses polynomial and Gaussian process surrogates of the CLM, and solves the parameter estimation problem using a Markov chain Monte Carlo sampler. Posterior probability densities for the parameters are developed for two sites with different soil and vegetation covers. Our method also allows us to examine the structural error in CLM under two error models. We find that surrogate models can be created for CLM in most cases. The posterior distributions are more predictive than the default parameter values in CLM. Climatologically averaging the observations does not modify the parameters' distributions significantly. The structural error model reveals a correlation time-scale which can be used to identify the physical process that could be contributing to it. While the calibrated CLM has a higher predictive skill, the calibration is under-dispersive.

54 ENVIRONMENTAL SCIENCES↗

The DarkSide-50 Experiment: Electron Recoil Calibrations and A Global Energy Variable

Over the course of decades, there has been mounting astronomical evidence for non-baryonic dark matter, yet its precise nature remains elusive. A favored candidate for dark matter is the Weakly Interacting Massive Particle (WIMP) which arises naturally out of extensions to the Standard Model. WIMPs are expected to occasionally interact with particles of normal matter through nuclear recoils. DarkSide-50 aims to detect this type of particle through the use of a two-phase liquid argon time projection chamber. To make a claim of discovery, an accurate understanding of the background and WIMP search region is imperative. Knowledge of the backgrounds is done through extensive studies of DarkSide-50's response to electron and nuclear recoils. The CALibration Insertion System (CALIS) was designed and built for the purpose of introduc- ing radioactive sources into or near the detector in a joint eort between Fermi National Laboratory (FNAL) and the University of Hawai'i at Manoa. This work describes the testing, installation, and commissioning of CALIS at the Laboratori Nazionali del Gran Sasso. CALIS has been used in mul- tiple calibration campaigns with both neutron and sources. In this work, DarkSide-50's response to electron recoils, which are important for background estimations, was studied through the use of calibration sources by constructing a global energy variable which takes into account the anti- correlation between scintillation and ionization signals produced by interactions in the liquid argon. Accurately reconstructing the event energy correlates directly with quantitatively understanding the WIMP sensitivity in DarkSide-50. This work also validates the theoretically predicted decay spectrum of 39Ar against 39Ar decay data collected in the early days of DarkSide-50 while it was lled with atmospheric argon; a validation of this type is not readily found in the literature. Finally, we show how well the constructed energy variable can predict energy spectra for the calibration sources and for 39Ar.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculational Model of the Radiation Calibration Lab (RCL) and the Neutron Measurements performed at the Facility, with a 252 Cf Source

Calibration of detectors measuring gamma, neutron, alpha and beta radiation, and of personal dosimeters used at Lawrence Livermore National Laboratory (LLNL), is performed at the Radiation Calibration Lab (RCL). The calibrations done with a standard calibrated 252 Cf source are a function of the energy spectra, fluence and dose of the source. A detailed calculational model of the RCL has been carried out with the MCNP6 code. The calculations have also reproduced quite well the measurements of the fluence and dose rates for the bare and moderated 252 Cf source carried out by R. Radev using the Rospec Spectrometer and by Clark and Wilson using a Passive Neutron Spectrometer. The importance of having the calculational model of the RCL facility is to calculate the dose rates expected for a given planned measurement, optimizing the choice of detectors, design and shielding materials before the actual measurement are carried out, resulting in a more efficient and time saving measurement. Furthermore, an accurate model of the facility allows to detect possible problems with the measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Anisotropic Elastic-Plastic Model Calibration

The purpose of this study was to first assess the sensitivity of the parameters of elasticplastic material models with anisotropic yield to choices in the calibration procedure. Two models were considered: Hill's 1948 and Barlat's Y1d2004-18p. Subsequently, it was shown that calibration choices can have an effect on the values of the stress and strain at the ultimate point in uniaxial specimen responses. Finally, the calibrated Barlat model was able to reasonably reproduce the load-deflection and strain fields of a validation specimen that experienced multiaxial states of stress. Overall, it was found that the Barlat model resulted in a closer fit to the measurements and that the parameters of the calibration procedure should be varied to assess the sensitivity of the results.

36 MATERIALS SCIENCE↗

Statistically Rigorous Uncertainty Quantification for Physical Parameter Model Calibration with Functional Output

In experiments conducted on the Z-machine at Sandia National Laboratories, dynamic material properties cannot be analyzed using traditional analytic methods, necessitating solving an inverse problem. Bayesian model calibration is a statistical framework for solving an inverse problem to estimate parameters input into a computational model in the presence of multiple uncertainties. Disentangling input parameter uncertainty and model misspecification is often poorly identified problem. When using computational models for physical parameter estimation, the issue of parameter identifiability must be carefully considered to obtain accurate and precise estimates of physical parameters. Additionally, in dynamic material properties applications, the experimental output is a function, velocity over time. While we can sample an arbitrarily large number of points from the measured velocity, these curves only contain a finite amount of information about the calibration parameters. In this report, we propose modifications to the Bayesian model calibration framework to simplify and improve the estimation of physical parameters with functional outputs. Specifically, we propose scaling the likelihood function by an effective sample size rather than modeling the discrepancy function; and modularizing input nuisance parameters with weakly identified parameters. We evaluate the performance of these proposed methods using a statistical simulation study and then apply these methods to estimate parameters of the tantalum equation of state. We conclude that these proposed methods can provide simple, fast, and statistically valid alternatives to the full Bayesian model calibration procedure; and that these methods can be used to estimate parameters of the equation of state for tantalum.

97 MATHEMATICS AND COMPUTING↗

3D Hall Probe Calibration Procedure

Hall probes are commonly used to measure local magnetic field, however they need to be calibrated. This technical note describes the accurate 3D Hall probe calibration system developed by the NSLS-II Insertion devices group at BNL. The calibration procedure and the calibration curves of an Arepoc 3D Hall probe have been presented.

36 MATERIALS SCIENCE↗

GoldSim E-Area Low-Level Waste Facility Aquifer Zone Model Calibration Methodology

This report documents the development and calibration of the E-Area Low-Level Waste Facility (ELLWF) Gold Sim aquifer model. It provides a methodology on how a Gold Sim aquifer model can be calibrated to specific PORFLOW-based aquifer predictions. The calibration activity presented within this report focuses on the Slit Trench #06 (ST06) location that resides within the center set of Slit Trenches. This Gold Sim-based aquifer model is a generic model capable of being calibrated to any of the other trench locations within E-Area. In addition, subsequent activities (beyond the scope of this effort) will couple this GoldSim-based aquifer model to various GoldSim-based trench models, with the intent of performing stochastic analyses that couple all pertinent fate and transport processes from the ground surface up to the 100-m point of assessment (POA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Re-calibration of PBX9501 SURF model

PBX 9501 is a plastic bonded explosive composed of 95 wt % HMX and a binder; see [Gibbs and Popolato, 1980, pp. 109–119]. SURF is a reactive burn model for shock initiation and propagation of detonation waves. It has previously been calibrated for PBX 9501. Here the SURF model is recalibrated for PBX 9501; specifically, lot 730-010 at ρ = 1.837 g/cc 3 . The new calibration uses the Davis reactants and products EOS calibrated for the AWSD model [Aslam et al., 2020]. The burn rate in the shock initiation regime is fit to the Pop plot from 5 embedded gauge shock-to-detonation transition (SDT) experiments from [Gustavsen et al., 1999, see fig 12 and table 5]. In the propagation regime, the burn rate is fit to curvature effect data (detonation speed as function of front curvature); see [Aslam, 2007]. Also the burn parameters are adjusted to fit the gap-stick experiment [Hill et al., 2018]. Simulating the detonation wave speed in this experiment requires a model that is accurate for initiation with complex shock loading; in particular, a pressure decreasing gradient behind a curved lead shock. This is more difficult than calibrating to the standard SDT experiments which are 1-D and driven by a sustained shock. Simulations of the gap-stick experiment for PBX 9501 with the SURF model will be discussed in a subsequent report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗