Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Building America Best Practices Series - Volume 12: Builders Challenge Guide to 40% Whole-House Energy Savings in the Cold and Very Cold Climates

This best practices guide is the twelfth in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the cold and very cold climates can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and thos erequirements are highlighted in the text. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Builders Challenge↗

Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. It presents a unique opportunity to evaluate and prioritize the wide-range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy savings benefits of improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishing a Commercial Buildings Energy Data Framework for India: A Comprehensive Look at Data Collection Approaches, Use Cases and Institutions

Enhancing energy efficiency of the commercial building stock is an important aspect of any national energy policy. Understanding how buildings use energy is critical to formulating any new policy that may impact energy use, underscoring the importance of credible data. Data enables informed decision making and good quality data is essential for policy makers to prioritize energy saving strategies and track implementation. Given the uniqueness of the buildings sector and challenges to collecting relevant energy data, this study characterizes various elements involved in pertinent data collection and management, with the specific focus on well-defined data requirements, appropriate methodologies and processes, feasible data collection mechanisms, and approaches to institutionalizing the collection process. This report starts with a comprehensive review of available examples of energy data collection frameworks for buildings across different countries. The review covers the U.S. experience in the commercial buildings sector, the European experience in the buildings sector and other data collection initiatives in Singapore and China to capture the more systematic efforts in Asia in the commercial sector. To provide context, the review includes a summary and status of disparate efforts in India to collect and use commercial building energy data. Using this review as a key input, the study developed a data collection framework for India with specific consideration to relevant use cases. Continuing with the framework for data collection, this study outlines the key performance indicators applicable to the use cases and their collection feasibility, as well as immediate priorities of the participating stakeholders. It also discusses potential considerations for data collection and the possible approaches for survey design. With the specific purpose of laying out the possible ways to structure and organize data collection institutionally, the study collates existing mechanisms to analyze building energy performance in India and opportunities for standardizing data collection. This report describes the existing capacities and resources for establishing an institutional framework for data collection, the legislation and mandates that support such activity, and identifies roles and responsibilities of the relevant ministries and organizations. Finally, the study presents conclusions and identifies two major data collection strategies within the existing legal framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Advanced Lighting Controls Retrofit Demonstration

Awareness of the economic costs and environmental consequences of electric energy use in buildings is steadily growing. Implementing energy efficiency measures for reducing energy consumption in buildings can be an effective strategy for managing these impacts. Within commercial buildings in the United States, electricity use for lighting accounts for 26% (around 346 TWh in 2010) and represents a large potential energy savings source. Significant lighting energy savings have already been achieved through the widespread adoption of efficient fluorescent lamps and ballasts in the past several decades. Looking towards efficient lighting operations’ innovations, wireless advanced lighting controls technology represents an increasingly viable option for capturing the next major level of lighting energy savings in new construction and building retrofits. Fundamentally, lighting is the most amenable building end use load for producing deep energy savings because of its dynamic controllability. Advanced lighting controls encompass control strategies from occupancy sensing to continuous dimming, institutional tuning and daylight harvesting. These strategies offer greater flexibility and higher granularity of control than traditional basic control methods. Historically, advanced control systems have required extensive control wiring, which has driven system costs. However, recently developed wireless lighting controls systems can be used to network lighting components, while potentially minimizing installation time and labor costs during retrofit in comparison to wired control systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Superefficient Refrigerators: Opportunities and Challenges for Efficiency Improvement Globally

As an energy-intensive mainstream product, residential refrigerators present a significant opportunity to reduce electricity consumption through energy efficiency improvements. Refrigerators expend a considerable amount of electricity during normal use, typically consuming between 100 to 1,000 kWh of electricity per annum. This paper presents the results of a technical analysis done for refrigerators in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative. Beginning from a base case representative of the average unit sold in India, we analyze efficiency improvement options and their corresponding costs to build a cost-versus-efficiency relationship. We then consider design improvement options that are known to be the most cost effective and that can improve efficiency given current design configurations. We also analyze and present additional super-efficient options, such as vacuum-insulated panels. We estimate the cost of conserved electricity for the various options, allowing flexible program design for market transformation programs toward higher efficiency. We estimate ~;;160TWh/year of energy savings are cost effective in 2030, indicating significant potential for efficiency improvement in refrigerators in SEAD economies and China.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet)

Achieving aggressive energy efficiency targets requires tight coordination and clear communication among owners, designers, builders, and subcontractors. For this townhome project, MassDevelopment, the quasi-governmental agency owner, selected Metric Development of Boston, teaming with the U.S. Department of Energy (DOE) Consortium for Advanced Residential Buildings (CARB) and Cambridge Seven Architects, to build very high performing market-rate homes. Fort Devens is part of a decommissioned army base in working-class Harvard, Massachusetts, approximately one hour northwest of Boston. The team proposed 12 net zero energy-ready townhomes, meaning that the application of renewable energy systems would result in annual net zero energy use in the homes. The homes were also designed to achieve a Home Energy Rating System (HERS) Index Score of 41 before adding renewables. For this project, CARB drew on its experience working with Rural Development Inc. on a series of affordable townhomes in northern Massachusetts. The team carefully planned the site to maximize solar access, daylighting, and efficient building forms. The basic strategy was to design a very efficient thermal enclosure while minimizing incremental cost increases compared with standard construction. Using BEopt modeling software, the team established the requirements of the enclosure and investigated multiple assembly options. They settled on double-wall construction with dense-pack cellulose fill. High performance vinyl windows (U-0.24, solar heat gain coefficient [SHGC]-0.22), a vented R-59 attic, and exceptional air sealing completed the package.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Jcpenney Buying into Energy Efficiency

Jcpenney partnered with the Department of Energy (DOE) to develop and implement solutions to build new, low-energy buildings that are at least 50% below Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air- Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

CBP↗

Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing

The overarching goal of this work is to advance the capabilities of technology evaluators in evaluating the building-level baseline modeling capabilities of Energy Management and Information System (EMIS) software. Through their customer engagement platforms and products, EMIS software products have the potential to produce whole-building energy savings through multiple strategies: building system operation improvements, equipment efficiency upgrades and replacements, and inducement of behavioral change among the occupants and operations personnel. Some offerings may also automate the quantification of whole-building energy savings, relative to a baseline period, using empirical models that relate energy consumption to key influencing parameters, such as ambient weather conditions and building operation schedule. These automated baseline models can be used to streamline the whole-building measurement and verification (M&V) process, and therefore are of critical importance in the context of multi-measure whole-building focused utility efficiency programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Campus Built on Efficiency - UC Merced

The University of California (UC), Merced partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit two existing buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Buildings Partnerships (CBP) Program.1 Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program. This case study reports expected savings from proposed design recommendations for the campus, which are subject to change in final construction. It is estimated that UC Merced will achieve the 30% reduction in the two participating buildings, the central plant and the Science & Engineering (S&E) building. The savings from retrofits of those buildings represent about 17% of whole-campus energy use. In addition, the energy saved by the CBP retrofits supports a broader goal, UC Merced’s “Triple Zero” commitment to zero net energy, zero landfill waste, and zero net greenhouse gas emissions by 2020. Although the campus has already made progress toward that goal with its efficient building construction and operation, opportunities for deeper savings remain, as the CBP project demonstrates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Is Every kWh the Same? How Do Energy Efficiency Measures Stack Up Across Regions?

The U.S. residential building sector is responsible for thirty-eight percent of electricity use, as well as for 49%, 8%, 19% and 2% of U.S. SO2, NOx, CO2 and PM2.5 emissions, respectively. The residential building sector is also a key target of customer funded energy efficiency programs, which have typically been designed to reduce energy consumption (kWh). Today, energy efficiency is also being used to meet air emissions goals. However, not every kWh saved has the same mitigation potential. The goal of this work is to evaluate energy efficiency potential in the U.S. residential building sector and determine how energy conservation measures (ECMs) that reduce electricity consumption correlate to air emissions reductions. To assess energy efficiency potential, this analysis uses Scout, a software program developed by the U.S. Department of Energy that estimates the energy and CO2 impact potential of various ECMs on the U.S. residential and commercial building sectors. Here, Scout is first used to assess the total long term national energy (electricity, gas, and oil), CO2, and cost savings of deploying residential ECM portfolios. Then, electricity savings results from Scout in 2021 are used to assess the regional differences in emissions reductions with the Avoided Emissions and geneRation Tool (AVERT) model from different end uses. Better understanding the relationship between ECMs and cost-effective emission reductions will enable states, municipalities and other interested parties to meet multiple policy objectives through energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Commercial Building Energy Asset Rating: Market Research and Program Direction

This paper presents the development of a voluntary energy asset rating system, to evaluate the physical characteristics and as-built energy efficiency of new and existing commercial buildings. The energy asset rating system is intended to enable commercial building stakeholders to directly compare expected as-built energy performance among similar buildings and to analyze the potential for capital improvements to increase energy efficiency cost-effectively. Market research has been performed to understand the market demand and how to communicate energy and cost savings to owners, investors, financiers, and others to overcome market barriers and motivate capital investment in building energy efficiency. The paper discusses the findings of the market research. Building owners are concerned about redundancy, conflicting requirements, and cost. They also pointed out a data gap and desire a rating program that identifies improvement opportunities. A meaningful linkage between the energy asset rating and other rating systems is essential. Based on the findings, criteria for a successful energy asset rating program have been developed to direct the program design, including validity of ratings, actionable, cost effective recommendations, effective quality control, integration with other rating systems, and necessary training and education. In addition to the rating system, an asset rating tool is being developed to reduce cost and increase standardization, allowing for consistent and reliable comparisons among and between buildings. The asset rating tool is the first step in the process by which owners can enter information about their building structure and receive information on the building’s modeled performance and recommended efficiency measures.

commercial building, energy asset rating, market r↗

Low temperature polyolefin deconstruction via tandem cracking-hydrogenation

The use of aluminum chloride in dichloromethane to crack polyolefin chains in tandem with alkylation of the resulting products has been previously reported as an efficient polyolefin recycling route. Building off this work, we report that a tandem cracking-hydrogenation system also efficiently converts polyolefins into gasoline-range light alkanes at mild temperatures without needing a hydrocarbon co-reactant. This Lewis acid and hydrogenation bifunctional system uses anhydrous aluminum chloride as the acid catalyst and Pd/C as a hydrogenation catalyst to achieve nearly 80 % conversion of low-density polyethylene (LDPE) at 70 °C in three hours, with 90+% selectivity towards gasoline-range (C 4 -C 12 ) branched alkanes. By combining the endothermic cracking reaction with the exothermic hydrogenation reaction, the thermodynamic limitations to low-temperature polyolefin deconstruction can be overcome. In using hydrogenation instead of alkylation, the system’s carbon efficiency is greatly improved, the cost of the reactants is reduced and the overall mass of both reactants and products reduced as well.

Alkylation↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2013 Building America Research Planning Meeting Summary

The Building America (BA) Research Planning Meeting was held October 28-30, 2013, in Washington, DC. This meeting provides one opportunity each year for the research teams, national laboratories and Department of Energy (DOE) managers to meet in person to share the most pertinent information and collaboration updates. This report documents the presentations, highlights key program updates, and outlines next steps for the program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Conversation on Zero Net Energy Buildings

Recently, zero net energy (ZNE) buildings have moved from state-of-the-art small project demonstrations to a more widely adopted approach across the country among various building types and sizes. States such as California set policy goals of all new residential construction to be NZE by 2020 and all commercial buildings to be NZE by 2030. However, the market for designing, constructing, and operating ZNE buildings is still relatively small. We bring together distinguished experts to share their thoughts on making ZNE buildings more widespread and mainstream from a broad perspective, including governments, utilities, energy-efficiency research institutes, and building owners. This conversation also presents the benefits of ZNE and ways to achieve that goal in the design and operation of buildings. The following is a roundtable conducted by ASHRAE Journal and Bing Liu with Charles Eley, Smita Gupta, Cathy Higgins, Jessica Iplikci, Jon McHugh, Michael Rosenberg, and Paul Torcellini.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Best Practices Series - Volume 15: 40% Whole-House Energy Savings in the Hot-Humid Climate

This best practices guide is the 15th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.

Building America↗