Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical Research”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Developing Technologies for Biological Experiments in Deep Space

NASA Ames Research Center is the leader in developing autonomous nanosatellites or CubeSats to address strategic knowledge gaps about the effects of space travel on biological organisms, including GeneSat, PharmaSat, and EcAMSat. Now that NASA has set its sights on human exploration in deep space, such missions require significant technological and biomedical countermeasures to protect astronauts from chronic radiation exposure. CubeSats can inform these countermeasures by querying relevant space environments with model organisms and/or biosensors. BioSentinel will be the first interplanetary CubeSat to study the biological response to space radiation outside low Earth orbit in almost 50 years. BioSentinel is an autonomous platform able to support biology and to investigate the effects of space radiation on a model organism in interplanetary deep space. It will fly onboard Artemis-1, from which it will be deployed on a lunar fly-by trajectory and into a heliocentric orbit. BioSentinel, a 6U CubeSat (1U = 10-cm cube), will measure the DNA damage response to ambient space radiation in a model organism, which will be compared to information provided by an onboard radiation spectrometer and to data obtained on the ISS and on Earth. Even though the primary objective of the mission is to develop an autonomous spacecraft capable of conducting biological experiments in deep space, the 4U BioSensor science payload contained within the free-flyer is an adaptable instrument that can perform bio measurements with different microorganisms and in multiple space environments, including the ISS, lunar gateway, and on the surface of the Moon. Thus, nanosatellites like BioSentinel can be used to study the effects of both reduced gravity and space radiation and can house different organisms to answer specific science questions. In addition to their flexibility, nanosatellites also provide a low-cost alternative to more complex and larger missions, and require minimal crew support, if any

biosenses↗

Developing Technologies for Biological Experiments in Deep Space

NASA Ames Research Center is the leader in developing autonomous nanosatellites or CubeSats to address strategic knowledge gaps about the effects of space travel on biological organisms, including GeneSat, PharmaSat, and EcAMSat. Now that NASA has set its sights on human exploration in deep space, such missions require significant technological and biomedical countermeasures to protect astronauts from chronic radiation exposure. CubeSats can inform these countermeasures by querying relevant space environments with model organisms and/or biosensors. BioSentinel will be the first interplanetary CubeSat to study the biological response to space radiation outside low Earth orbit in almost 50 years. BioSentinel is an autonomous platform able to support biology and to investigate the effects of space radiation on a model organism in interplanetary deep space. It will fly onboard Artemis-1, from which it will be deployed on a lunar fly-by trajectory and into a heliocentric orbit. BioSentinel, a 6U CubeSat (1U = 10-cm cube), will measure the DNA damage response to ambient space radiation in a model organism, which will be compared to information provided by an onboard radiation spectrometer and to data obtained on the ISS and on Earth. Even though the primary objective of the mission is to develop an autonomous spacecraft capable of conducting biological experiments in deep space, the 4U BioSensor science payload contained within the free-flyer is an adaptable instrument that can perform bio measurements with different microorganisms and in multiple space environments, including the ISS, lunar gateway, and on the surface of the Moon. Thus, nanosatellites like BioSentinel can be used to study the effects of both reduced gravity and space radiation and can house different organisms to answer specific science questions. In addition to their flexibility, nanosatellites also provide a low-cost alternative to more complex and larger missions, and require minimal crew support, if any.

biosenses↗

SU-E-T-376: 3-D Commissioning for An Image-Guided Small Animal Micro- Irradiation Platform

Purpose: A 3-D radiochromic plastic dosimeter has been used to cross-test the isocentricity of a high resolution image-guided small animal microirradiation platform. In this platform, the mouse stage rotating for cone beam CT imaging is perpendicular to the gantry rotation for sub-millimeter radiation delivery. A 3-D dosimeter can be used to verify both imaging and irradiation coordinates. Methods: A 3-D dosimeter and optical CT scanner were used in this study. In the platform, both mouse stage and gantry can rotate 360° with rotation axis perpendicular to each other. Isocentricity and coincidence of mouse stage and gantry rotations were evaluated using star patterns. A 3-D dosimeter was placed on mouse stage with center at platform isocenter approximately. For CBCT isocentricity, with gantry moved to 90°, the mouse stage rotated horizontally while the x-ray was delivered to the dosimeter at certain angles. For irradiation isocentricity, the gantry rotated 360° to deliver beams to the dosimeter at certain angles for star patterns. The uncertainties and agreement of both CBCT and irradiation isocenters can be determined from the star patterns. Both procedures were repeated 3 times using 3 dosimeters to determine short-term reproducibility. Finally, dosimeters were scanned using optical CT scanner to obtain the results. Results: The gantry isocentricity is 0.9 ± 0.1 mm and mouse stage rotation isocentricity is about 0.91 ± 0.11 mm. Agreement between the measured isocenters of irradiation and imaging coordinates was determined. The short-term reproducibility test yielded 0.5 ± 0.1 mm between the imaging isocenter and the irradiation isocenter, with a maximum displacement of 0.7 ± 0.1 mm. Conclusion: The 3-D dosimeter can be very useful in precise verification of targeting for a small animal irradiation research. In addition, a single 3-D dosimeter can provide information in both geometric and dosimetric uncertainty, which is crucial for translational studies.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction

Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

Purpose: Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as intermediate endpoints of asthma severity and control. In particular, pulmonary {sup 1}H MRI can be used to provide quantitative lung structure-function measurements longitudinally and in response to treatment. However, to translate such biomarkers of asthma, robust methods are required to segment the lung from pulmonary {sup 1}H MRI. Therefore, their objective was to develop a pulmonary {sup 1}H MRI segmentation algorithm to provide regional measurements with the precision and speed required to support clinical studies. Methods: The authors developed a method to segment the left and right lung from {sup 1}H MRI acquired in 20 asthmatics including five well-controlled and 15 severe poorly controlled participants who provided written informed consent to a study protocol approved by Health Canada. Same-day spirometry and plethysmography measurements of lung function and volume were acquired as well as {sup 1}H MRI using a whole-body radiofrequency coil and fast spoiled gradient-recalled echo sequence at a fixed lung volume (functional residual capacity + 1 l). We incorporated the left-to-right lung volume proportion prior based on the Potts model and derived a volume-proportion preserved Potts model, which was approximated through convex relaxation and further represented by a dual volume-proportion preserved max-flow model. The max-flow model led to a linear problem with convex and linear equality constraints that implicitly encoded the proportion prior. To implement the algorithm, {sup 1}H MRI was resampled into ∼3 × 3 × 3 mm{sup 3} isotropic voxel space. Two observers placed seeds on each lung and on the background of 20 pulmonary {sup 1}H MR images in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.

60 APPLIED LIFE SCIENCES↗

SU-C-202-05: Pilot Study of Online Treatment Evaluation and Adaptive Re-Planning for Laryngeal SBRT

Purpose: We have instigated a phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for advanced-stage laryngeal cancer. We conducted this pilot dosimetric study to confirm the potential utility of online adaptive re-planning to preserve treatment quality. Methods: Ten cases of larynx cancer were evaluated. Baseline and daily SBRT treatment plans were generated per trial protocol. Daily volumetric images were acquired prior to every fraction of treatment. Reference simulation CT images were deformably registered to daily volumetric images using Eclipse. Planning contours were then deformably propagated to daily images. Reference SBRT plans were directly copied to calculate delivered dose distributions on deformed reference CT images. In-house software platform has been developed to calculate cumulative dose over a course of treatment in four steps: 1) deforming delivered dose grid to reference CT images using deformation information exported from Eclipse; 2) generating tetrahedrons using deformed dose grid as vertices; 3) resampling dose to a high resolution within every tetrahedron; 4) calculating dose-volume histograms. Our inhouse software was benchmarked with a commercial software, Mirada. Results: In all ten cases including 49 fractions of treatments, delivered daily doses were completely evaluated and treatment could be re-planned within 10 minutes. Prescription dose coverage of PTV was less than intended in 53% of fractions of treatment (mean: 94%, range: 84%–98%) while minimum coverage of CTV and GTV was 94% and 97%, respectively. Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. Conclusion: Although GTV and CTV coverage is preserved by in-room 3D image guidance of larynx SBRT, PTV coverage can vary significantly from intended plans. Online adaptive treatment evaluation and re-planning is potentially necessary and our procedure is clinically applicable to fully preserve treatment quality. This project is supported by CPRIT Individual Investigator Research Award RP150386.

60 APPLIED LIFE SCIENCES↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-F-I-38: Patient Organ Specific Dose Assessment in Coronary CT Angiograph Using Voxellaized Volume Dose Index in Monte Carlo Simulation

Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-system component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose. This work has been supported by the research chancellor of tehran university of medical sciences(tums), school of medicine, Tehran, Iran.

60 APPLIED LIFE SCIENCES↗

SU-F-I-49: Vendor-Independent, Model-Based Iterative Reconstruction On a Rotating Grid with Coordinate-Descent Optimization for CT Imaging Investigations

Purpose: Iterative reconstruction methods show promise for improving image quality and lowering the dose in helical CT. We aim to develop a novel model-based reconstruction method that offers potential for dose reduction with reasonable computation speed and storage requirements for vendor-independent reconstruction from clinical data on a normal desktop computer. Methods: In 2012, Xu proposed reconstructing on rotating slices to exploit helical symmetry and reduce the storage requirements for the CT system matrix. Inspired by this concept, we have developed a novel reconstruction method incorporating the stored-system-matrix approach together with iterative coordinate-descent (ICD) optimization. A penalized-least-squares objective function with a quadratic penalty term is solved analytically voxel-by-voxel, sequentially iterating along the axial direction first, followed by the transaxial direction. 8 in-plane (transaxial) neighbors are used for the ICD algorithm. The forward problem is modeled via a unique approach that combines the principle of Joseph’s method with trilinear B-spline interpolation to enable accurate reconstruction with low storage requirements. Iterations are accelerated with multi-CPU OpenMP libraries. For preliminary evaluations, we reconstructed (1) a simulated 3D ellipse phantom and (2) an ACR accreditation phantom dataset exported from a clinical scanner (Definition AS, Siemens Healthcare). Image quality was evaluated in the resolution module. Results: Image quality was excellent for the ellipse phantom. For the ACR phantom, image quality was comparable to clinical reconstructions and reconstructions using open-source FreeCT-wFBP software. Also, we did not observe any deleterious impact associated with the utilization of rotating slices. The system matrix storage requirement was only 4.5GB, and reconstruction time was 50 seconds per iteration. Conclusion: Our reconstruction method shows potential for furthering research in low-dose helical CT, in particular as part of our ongoing development of an acquisition/reconstruction pipeline for generating images under a wide range of conditions. Our algorithm will be made available open-source as “FreeCT-ICD”. NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.

60 APPLIED LIFE SCIENCES↗

SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm{sup 2}) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

60 APPLIED LIFE SCIENCES↗

Design and structural basis of selective 1,4-dihydropyridine inhibitors of the calcium-activated potassium channel K Ca 3.1

The 1,4-dihydropyridines, drugs with well-established bioavailability and toxicity profiles, have proven efficacy in treating human hypertension, peripheral vascular disorders, and coronary artery disease. Every 1,4-dihydropyridine in clinical use blocks L-type voltage-gated calcium channels. We now report our development, using selective optimization of a side activity (SOSA), of a class of 1,4-dihydropyridines that selectively and potently inhibit the intermediate-conductance calcium-activated K + channel K Ca 3.1, a validated therapeutic target for diseases affecting many organ systems. One of these 1,4-dihydropyridines, DHP-103, blocked K Ca 3.1 with an IC 50 of 6 nM and exhibited exquisite selectivity over calcium channels and a panel of >100 additional molecular targets. Using high-resolution structure determination by cryogenic electron microscopy together with mutagenesis and electrophysiology, we delineated the drug binding pocket for DHP-103 within the water-filled central cavity of the K Ca 3.1 channel pore, where bound drug directly impedes ion permeation. DHP-103 inhibited gain-of-function mutant K Ca 3.1 channels that cause hereditary xerocytosis, suggesting its potential use as a therapeutic for this hemolytic anemia. In a rat model of acute ischemic stroke, the second leading cause of death worldwide, DHP-103 administered 12 h postischemic insult in proof-of-concept studies reduced infarct volume, improved balance beam performance (measure of proprioception) and decreased numbers of activated microglia in infarcted areas. K Ca 3.1-selective 1,4-dihydropyridines hold promise for the many diseases for which K Ca 3.1 has been experimentally confirmed as a therapeutic target.

Ong, Seow Theng [Lee Kong Chian School of Medicine↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. Results: The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. Conclusions: These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-03: Advances in CBCT for Orhtopaedics and Bone Health Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-04: Advances in CBCT for Breast Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-CD-304-11: Veritas 2.0: A Cloud-Based Tool to Facilitate Research and Innovation

Purpose: We introduce Veritas 2.0, a cloud-based, non-clinical research portal, to facilitate translation of radiotherapy research ideas to new delivery techniques. The ecosystem of research tools includes web apps for a research beam builder for TrueBeam Developer Mode, an image reader for compressed and uncompressed XIM files, and a trajectory log file based QA/beam delivery analyzer. Methods: The research beam builder can generate TrueBeam readable XML file either from scratch or from pre-existing DICOM-RT plans. DICOM-RT plan is first converted to XML format and then researcher can interactively modify or add control points to them. Delivered beam can be verified via reading generated images and analyzing trajectory log files. Image reader can read both uncompressed and HND-compressed XIM images. The trajectory log analyzer lets researchers plot expected vs. actual values and deviations among 30 mechanical axes. The analyzer gives an animated view of MLC patterns for the beam delivery. Veritas 2.0 is freely available and its advantages versus standalone software are i) No software installation or maintenance needed, ii) easy accessibility across all devices iii) seamless upgrades and iv) OS independence. Veritas is written using open-source tools like twitter bootstrap, jQuery, flask, and Python-based modules. Results: In the first experiment, an anonymized 7-beam DICOM-RT IMRT plan was converted to XML beam containing 1400 control points. kV and MV imaging points were inserted into this XML beam. In another experiment, a binary log file was analyzed to compare actual vs expected values and deviations among axes. Conclusions: Veritas 2.0 is a public cloud-based web app that hosts a pool of research tools for facilitating research from conceptualization to verification. It is aimed at providing a platform for facilitating research and collaboration. I am full time employee at Varian Medical systems, Palo Alto.

60 APPLIED LIFE SCIENCES↗