Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. Furthermore, the full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of terahertz radiation generated using a metallic, corrugated pipe

Here, a method for producing narrow-band THz radiation proposes passing an ultra-relativistic beam through a metallic pipe with small periodic corrugations. We present results of a measurement of such an arrangement at Brookhaven's Accelerator Test Facility (ATF). Our pipe was copper and was 5 cm long; the aperture was cylindrically symmetric, with a 1 mm (radius) bore and a corrugation depth (peak-to-peak) of 60 µm. In the experiment we measured both the effect on the beam of the structure wakefield and the spectral properties of the radiation excited by the beam. We began by injecting a relatively long beam compared to the wavelength of the radiation, but with short rise time, to excite the structure, and then used a downstream spectrometer to infer the radiation wavelength. This was followed by injecting a shorter bunch, and then using an interferometer (also downstream of the corrugated pipe) to measure the spectrum of the induced THz radiation. For the THz pulse we obtain and compare with calculations: the central frequency, the bandwidth, and the spectral power—compared to a diffraction radiation background signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

In this paper, a four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm 2 and an absorption layer thickness of 110 μ m. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. Finally, for the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of modulated beams in spectral domain

General formalism for describing dynamics of modulated beams along linear beamlines is developed. We describe modulated beams with spectral distribution function which represents Fourier transform of the conventional beam distribution function in the 6-dimensional phase space. The introduced spectral distribution function is localized in some region of the spectral domain for nearly monochromatic modulations. It can be characterized with a small number of typical parameters such as the lowest order moments of the spectral distribution. We study evolution of the modulated beams in linear beamlines and find that characteristic spectral parameters transform linearly. The developed approach significantly simplifies analysis of various schemes proposed for seeding X-ray free electron lasers. We use this approach to study several recently proposed schemes and find the bandwidth of the output bunching in each case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impedance computations and beam-based measurements: A problem of discrepancy

High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. For this article, three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.

43 PARTICLE ACCELERATORS↗

Numerical study and test of the APS linac transverse deflecting cavity

The transverse deflecting cavity can be used to transform particle distributions in the 6D phase space, which makes it a promising component in phase space beam diagnostics and beam manipulations. In the Advanced Photon Source (APS) Linac, a LOLA-type traveling wave deflecting cavity was installed for the diagnostics of beam characteristics, such as the bunch length, bunch temporal profile, time-dependent energy spread and slice (time-correlated) transverse emittance. In this paper, this deflecting cavity is modeled and analyzed with the numerical method. The effects of the center cell and coupler cell dimensions on the performance of the whole structure are studied, which shows the coupler cell radius has a dominant effect over the coupler cell length and slot width on the global reflection coefficient and field flatness. Important RF parameters, such as S-11, field flatness and phase advance etc., of the LOLA-II cavity in tuning are calculated and discussed. After optimization, the field flatness of the cavity is 2.1%, the phase advance is 119.66 degrees degrees with a standard deviation smaller than 0.5 degrees and the bandwidth is 15.738 MHz when VSWR < 1.1 (i.e. the S-11, < -26 dB). Bead-pull measurements and RF conditioning have been also performed and discussed. Finally, the initial cavity commissioning with electron beam of 375 MeV is reported, and compared with simulation.

coupler↗

Study of a free-electron laser driven by a laser-plasma accelerated beam at Peking University

The percent level energy spread and large divergence of laser-plasma beam are the main challenges of realizing compact short-wavelength free-electron lasers based on laser-plasma accelerators. These issues can be solved with proposed transverse gradient undulator method or bunch decompression method along with proper transport design. We present a study of using an expected 500 MeV laser-plasma beam with 0.3 mm•mrad normalized emittance and 0.3 mrad divergence at Peking University to drive compact free-electron laser at 30 nm. We employ the bunch decompression method with a chromatic matching beamline as well as the transverse gradient undulator method with assumed matched beam. Simulation shows that 700 MW power, 9.7 fs pulse duration and 0.85% relative bandwidth FEL output can be obtained using chromatic matched bunch decompression method. As a result FEL with similar performance can be obtained using the transverse gradient undulator scheme.

47 OTHER INSTRUMENTATION↗

Optimization of a superconducting adiabatic radio frequency neutron resonant spin flipper

The neutron radio frequency (RF) spin flipper is one of the key components to implement neutron resonance spin echo (NRSE) for high resolution measurements of dynamics in materials. Various types of RF flippers have been built and implemented including adiabatic and non-adiabatic RF flippers. For a pulsed neutron source, adiabatic RF flipper is more favorable due to its wide operation bandwidth. However, the optimization criteria of an adiabatic RF flipper is still lacking. Also they are difficult to be operated in bootstrap mode, which can be use to minimize the phase aberration and increase the achievable resolution. In the report by Dadisman et al. (2019), an adiabatic RF flipper has been built for the first time with superconducting technologies, which allows bootstrap mode. Here in this article, the method of optimizing the device and the detailed design will be discussed for each component of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent improvements in beam orbit feedback at NSLS-II

This paper discusses improvements made to the fast orbit feedback (FOFB) system at NSLS-II in 2019. We first characterized the system by measuring the transfer function and the closed-loop gain of the system. We also constructed a model to predict the performance, which was based on physical behaviors. After finding and fixing the sources of the latency, we improved the closed-loop gain’s bandwidth from 250 Hz to 400 Hz in the horizontal plane and 250 Hz to 300 Hz in the vertical plane. As a result, the orbit beam instability improved by 30% and 10% in the horizontal and vertical planes, respectively.

36 MATERIALS SCIENCE↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Shielded radiography with a laser-driven MeV-energy X-ray source

We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 10 7 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ~100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam’s inherently low-divergence angle (~mrad) is advantageous and effective for interrogation at standoff distance. Furthermore, these results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation shielding analysis of the small-angle X-ray scattering flight tube end station of APS upgrade project

The CSSI beamline of the APSU will have a 20.5 m long, 2.75 m diameter SS end station designed to accept pink beam. In this work, the radiation shielding analysis of this end station is analyzed using STAC8 and FLUKA codes. Effect of mirror properties such as reflectivity, coating, inclination and roughness as well as variation in the steel composition are also studied. 8 mm thick SS is found to be adequate if the source is defined by a pinhole and the white beam is reflected with two mirrors inclined at 3.0 mradian or more. The dose rates from monochromatic beams are found to be below the desired levels when the XOP calculated bandwidth (BW) are used while the use of a flat 0.1% BW requires the mirror inclinations to be above 2.5 mradian or more. STAC8 results are consistently higher than the FLUKA results by about 1.5–2.0 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital phase demodulation for low-coherence interferometry-based fiber-optic sensors

In this paper, we describe a digital phase demodulation scheme for low-coherence interferometry-based fiber-optic sensors by employing a simple generation of phase-shifted signals at the interrogation interferometer. The scheme allows a real-time calibration process and offers capability of measuring large variations (up to the coherence of the light source) at the bandwidth that is only limited by the data acquisition system. Finally, the proposed phase demodulation method is analytically derived and its validity and performance are experimentally verified using fiber-optic Fabry–Perot sensors for measurement of strains and vibrations.

47 OTHER INSTRUMENTATION↗

Implementation and Evaluation of Active Storage in Modern Parallel File Systems

Active Storage is a technology aimed at reducing the bandwidth requirements of current supercomputing systems, and leveraging the processing power of the storage nodes used by some modern file systems. Active Storage achieves both objectives by moving certain processing tasks to the storage nodes, near the data they manage. Our proposal for Active Storage has several key features: user-space implementation which facilitates the port to different file systems, analytical model to anticipate the performance of Active Storage with respect to a traditional system, support for striped files and complex format files such as netCDF, scientific-friendly programming and runtime environment, etc.

99 GENERAL AND MISCELLANEOUS↗

Petascale solvers for anisotropic PDEs in atmospheric modelling on GPU clusters

Memory bound applications such as solvers for large sparse systems of equations remain a challenge for GPUs. Fast solvers should be based on numerically efficient algorithms and implemented such that global memory access is minimised. To solve systems with trillions ( O ( 10 12 ) ) unknowns the code has to make efficient use of several million individual processor cores on large GPU clusters. We describe the multi-GPU implementation of two algorithmically optimal iterative solvers for anisotropic PDEs which are encountered in (semi-) implicit time stepping procedures in atmospheric modelling. In this application the condition number is large but independent of the grid resolution and both methods are asymptotically optimal, albeit with different absolute performance. In particular, an important constant in the discretisation is the CFL number; only the multigrid solver is robust to changes in this constant. We parallelise the solvers and adapt them to the specific features of GPU architectures, paying particular attention to efficient global memory access. We achieve a performance of up to 0.78 PFLOPs when solving an equation with 0.55 · 10 12 unknowns on 16384 GPUs; this corresponds to about 3% of the theoretical peak performance of the machine and we use more than 40% of the peak memory bandwidth with a Conjugate Gradient (CG) solver. Although the other solver, a geometric multigrid algorithm, has a slightly worse performance in terms of FLOPs per second, overall it is faster as it needs less iterations to converge; the multigrid algorithm can solve a linear PDE with half a trillion unknowns in about one second.

Computer Science↗