SU-F-T-146: Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPAS (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.

60 APPLIED LIFE SCIENCES↗

Determination of physically based pseudo-Voigt powder diffraction profile terms from the fundamental parameters approach

In this study, a methodology is developed where a fundamental parameters approach (FPA) description of a laboratory powder diffraction instrument (configured in divergent-beam Bragg–Brentano geometry) is used to determine GSAS-II profile parameters for peak asymmetry and instrumental peak widths. This allows the instrumental contribution to peak shapes to be robustly determined directly from a physical description of the instrument, even though GSAS-II does not directly implement FPA for peak shape computation. The FPA-derived parameters can be used as the starting point for instrument characterization, or to characterize sample broadening without the use of a standard to determine the instrument profile function. This new method can facilitate generation of training sets for machine learning. A plot is generated that shows the differences between the two approaches, demonstrating upper bounds for the accuracy of the GSAS-II profile model for a particular instrumental configuration.

47 OTHER INSTRUMENTATION↗

Designs and Materials for Better Coronagraph Occulting Masks

New designs, and materials appropriate for such designs, are under investigation in an effort to develop coronagraph occulting masks having broad-band spectral characteristics superior to those currently employed. These designs and materials are applicable to all coronagraphs, both ground-based and spaceborne. This effort also offers potential benefits for the development of other optical masks and filters that are required (1) for precisely tailored spatial transmission profiles, (2) to be characterized by optical-density neutrality and phase neutrality (that is, to be characterized by constant optical density and constant phase over broad wavelength ranges), and/or (3) not to exhibit optical- density-dependent phase shifts. The need for this effort arises for the following reasons: Coronagraph occulting masks are required to impose, on beams of light transmitted through them, extremely precise control of amplitude and phase according to carefully designed transmission profiles. In the original application that gave rise to this effort, the concern has been to develop broad-band occulting masks for NASA s Terrestrial Planet Finder coronagraph. Until now, experimental samples of these masks have been made from high-energy-beam-sensitive (HEBS) glass, which becomes locally dark where irradiated with a high-energy electron beam, the amount of darkening depending on the electron-beam energy and dose. Precise mask profiles have been written on HEBS glass blanks by use of electron beams, and the masks have performed satisfactorily in monochromatic light. However, the optical-density and phase profiles of the HEBS masks vary significantly with wavelength; consequently, the HEBS masks perform unsatisfactorily in broad-band light. The key properties of materials to be used in coronagraph occulting masks are their extinction coefficients, their indices of refraction, and the variations of these parameters with wavelength. The effort thus far has included theoretical predictions of performances of masks that would be made from alternative materials chosen because the wavelength dependences of their extinction coefficients and their indices of refraction are such that that the optical-density and phase profiles of masks made from these materials can be expected to vary much less with wavelength than do those of masks made from HEBS glass. The alternative materials considered thus far include some elemental metals such as Pt and Ni, metal alloys such as Inconel, metal nitrides such as TiN, and dielectrics such as SiO2. A mask as now envisioned would include thin metal and dielectric films having stepped or smoothly varying thicknesses (see figure). The thicknesses would be chosen, taking account of the indices of refraction and extinction coefficients, to obtain an acceptably close approximation of the desired spatial transmittance profile with a flat phase profile

Balasubramanian, Kunjithapatham↗

Generalized Procedure for Improved Accuracy of Thermal Contact Resistance Measurements for Materials With Arbitrary Temperature-Dependent Thermal Conductivity

Thermal contact resistance (TCR) is most commonly measured using one-dimensional steady-state calorimetric techniques. In the experimental methods we utilized, a temperature gradient is applied across two contacting beams and the temperature drop at the interface is inferred from the temperature profiles of the rods that are measured at discrete points. During data analysis, thermal conductivity of the beams is typically taken to be an average value over the temperature range imposed during the experiment. Our generalized theory is presented and accounts for temperature-dependent changes in thermal conductivity. The procedure presented enables accurate measurement of TCR for contacting materials whose thermal conductivity is any arbitrary function of temperature. For example, it is shown that the standard technique yields TCR values that are about 15% below the actual value for two specific examples of copper and silicon contacts. Conversely, the generalized technique predicts TCR values that are within 1% of the actual value. The method is exact when thermal conductivity is known exactly and no other errors are introduced to the system.

42 ENGINEERING↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

SU-E-T-386: A Monte Carlo Dose Calculation Framework for Electron Beams On Varian TrueBeam

Purpose: The design of the linac head is different for TrueBeam than Clinac, and there are differences in measured dose distributions in water phantoms between TrueBeam and Clinac for electron beams. Therefore, MC models for Clinac may not be applied directly to the Truebeam linac. The purpose of this study is to validate a Monte Carlo (MC) dose calculation framework for electron beams on Varian TrueBeam with phase space files provided by Varian. Methods: The particle histories from the phase space file were used as input for the down-stream simulation including jaws, applicators, and water phantom. MC packages BEAMnrc/DOSYXZnrc were used. The down-stream beam components were modeled according to manufacturer specifications and the dose distributions were compared with the measured data of standard cones. The measurements were performed in a water phantom with a p-type electron field diode (diameter 0.2cm) and ion chamber (CC13). Depth dose and orthogonal profiles at depths defined by R{sub 1} {sub 0} {sub 0}, R{sub 5} {sub 0}, Rp were compared. Results: Preliminary results for a 16 MeV phase space and 10x10, 15x15, and 20x20 cm{sup 2} applicator are presented. Simulations were run for a statistical uncertainty of <2% at depth of maximum dose for a voxel resolution of 0.5x0.5x0.2cm{sup 2}. Dose and range differences for the PDD profiles were within 2% and 1 mm, respectively. Dose differences within the central 80% of the beam width for the orthogonal profiles at depth of maximum dose were less than 2% for the 10x10, 15x15, and 20x20 cm{sup 2} applicator, respectively. Conclusion: Varian electron phase space files simulations are in agreement with measured commissioning data. These phase space files can be used in the simulation of TrueBeam linacs, and will provide reproducibility across publications. Analyses for all electron energies and standard applicators are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

Compact, low profile antennas for MSAT and mini-M and Std-M land mobile satellite communications

CAL Corporation has developed a new class of low profile radiating elements for use in planar phased array antennas. These new elements have been used in the design of a low cost, compact, low profile antenna unit for MSAT and INMARSAT Mini-M land mobile satellite communications. The antenna unit which measures roughly 32 cm in diameter by 5 cm deep incorporates a compact LNA and diplexer unit as well as a complete, low cost, beam steering system. CAL has also developed a low profile antenna unit for INMARSAT-M land mobile satellite communications. A number of these units, which utilize a microstrip patch array design, were put into service in 1994.

Strickland, P. C.↗

Caustics and Caustic-Diffraction in Laser Shadowgraphy of a Sessile Drop and Identification of Profile Near Contact Line

This paper presents an optical method based on the caustics and caustic-difraction in laser shadowgaphy of a sessile drop to identify and estimate the drop profile near the contact line. A parallel laser beam passes through a liquid sessile drop placed on a transparent substrate to produce a shadowgraphic image of the drop on the screen far from the substrate. Along the inflection line of the drop the Gaussian curvature of the wavefront deformed by the drop vanishes, and therefore the inflection line gives caustics in the far field of the wave, which can be seen on the screen. The neighboring light rays at both sides of the inflection line interfere with each other to form interference fringes at the inner side of the caustics. According to the pattern of the caustics, the drop-profile shape can be identified and estimated.

Zhang, Neng-Li↗

TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

60 APPLIED LIFE SCIENCES↗

Multiple Synchrotron Light Monitors for Transverse Matching and Monitoring at CEBAF

Beam setup at the Continuous Electron Beam Accelerator Facility (CEBAF) involves threading beam through the machine and monitoring global transfer functions to identify and address cumulative lattice errors. Transverse beam emittance may grow by as much as two orders of magnitude, mediated by synchrotron radiation. Re-matching the enlarged beam phase space into successive re-circulation arcs minimizes this emittance growth but requires knowledge of the actual beam distribution. This is now accomplished through quadrupole scans using wire profile monitors, the most time-consuming activity in our setup process. We propose to use Synchrotron Light Monitors (SLMs) to image the beam at homologous points in the four super-period recirculation arc lattices. Benefits include real-time monitoring of beam parameters and reduced elapsed time for initial setup.These SLMs will be installed in Arc 7 of the CEBAF machine, where Synchrotron Radiation contributes moderately to emittance growth. One of four required SLMs will be installed and commissioned this year, with the rest being installed next year.

Freeman, B.↗

TH-AB-201-03: Characterization of Electron Beam Out-Of-Field Doses and Neutron Contamination from Modern Varian and Elekta Linear Accelerators

Purpose: To investigate out-of-field electron doses and neutron production from electron beams from modern Varian and Elekta linear accelerators. Methods: Electron dose measurements were made using 10×10cm{sup 2} applicators on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at energies from 6 to 20 MeV. Out-of-field dose profiles and PDD curves were measured in a Wellhofer water phantom using a Farmer chamber. Neutron measurements were made with a combination of moderator buckets and gold activation-foils placed on the treatment couch at various locations in the patient plane on both the 21iX and Versa HD linear accelerators. Results: Electron doses were highest for the highest electron energies. Dose profile curves for the Varian units were found to be lower than those from the Versa HD unit, and were lower than photon beams. Elekta’s dose profiles were higher and exhibited a second dose peak around 20–30 cm from central-axis. Electron doses in this region (0.8–1.3% of dmax at central-axis) were close to 5 times (2.5–4.8) greater than doses from photon beams with similar energies. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Q-values and neutron dose equivalent increased with energy and were typically higher on central-axis. 18 MV photon beam neutron dose equivalents were greater than any electron beam, being approximately 40 times greater than for the 20 MeV electron beam (21iX). Conclusion: The Versa HD exhibited higher than expected out-of-field electron doses in comparison to typical radiotherapy photon beams. Fortunately, out-of-field electron doses can be substantially reduced by applying a water-equivalent bolus with thickness of E(MeV)/4 in cm. Neutron contamination from clinical electron beams can be considered negligible in relation to photon beams but may need to be considered for special cases. This work was supported by Public Health Service Grant CA180803 awarded by the National Cancer Institute, United States Department of Health and Human Services.

07 ISOTOPE AND RADIATION SOURCES↗

Charge exchange recombination spectroscopy at Wendelstein 7-X

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, to include typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

47 OTHER INSTRUMENTATION↗

SU-G-BRA-14: Dose in a Rigidly Moving Phantom with Jaw and MLC Compensation

Purpose: To validate dose calculation for a rigidly moving object with jaw motion and MLC shifts to compensate for the motion in a TomoTherapy™ treatment delivery. Methods: An off-line version of the TomoTherapy dose calculator was extended to perform dose calculations for rigidly moving objects. A variety of motion traces were added to treatment delivery plans, along with corresponding jaw compensation and MLC shift compensation profiles. Jaw compensation profiles were calculated by shifting the jaws such that the center of the treatment beam moved by an amount equal to the motion in the longitudinal direction. Similarly, MLC compensation profiles were calculated by shifting the MLC leaves by an amount that most closely matched the motion in the transverse direction. The same jaw and MLC compensation profiles were used during simulated treatment deliveries on a TomoTherapy system, and film measurements were obtained in a rigidly moving phantom. Results: The off-line TomoTherapy dose calculator accurately predicted dose profiles for a rigidly moving phantom along with jaw motion and MLC shifts to compensate for the motion. Calculations matched film measurements to within 2%/1 mm. Jaw and MLC compensation substantially reduced the discrepancy between the delivered dose distribution and the calculated dose with no motion. For axial motion, the compensated dose matched the no-motion dose within 2%/1mm. For transverse motion, the dose matched within 2%/3mm (approximately half the width of an MLC leaf). Conclusion: The off-line TomoTherapy dose calculator accurately computes dose delivered to a rigidly moving object, and accurately models the impact of moving the jaws and shifting the MLC leaf patterns to compensate for the motion. Jaw tracking and MLC leaf shifting can effectively compensate for the dosimetric impact of motion during a TomoTherapy treatment delivery.

60 APPLIED LIFE SCIENCES↗

Laser-driven collisionless shock acceleration of ions from near-critical plasmas

Here, this paper overviews experimental and numerical results on acceleration of narrow energy spread ion beams by an electrostatic collisionless shockwave driven by 1 μm (Omega EP) and 10 μm (UCLA Neptune Laboratory) lasers in near critical density CH and He plasmas, respectively. Shock waves in CH targets produced high-energy ~50 MeV protons (ΔE/E of ≤30%) and 314 MeV C 6+ ions (ΔE/E of ≤10%). Observation of acceleration of both protons and carbon ions to similar velocities is consistent with reflection of particles off the moving potential of a shock front. For shocks driven by CO 2 laser in a gas jet, ~30 MeV peak in He ion spectrum was detected. Particle-in-cell simulations indicate that regardless of the target further control over its density profile is needed for optimization of accelerated ion beams in part of energy spread, yield and maximum kinetic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Redirection and reshaping of intense extreme-ultraviolet radiation

The goal to control short-wavelength radiation for the investigation and manipulation of ultrafast dynamics in quantum systems coevolves with the growing availability of extreme-ultraviolet (XUV) and x-ray sources from high-harmonic generation and free-electron lasers. Here, we present an XUV spatio-spectral phase modulator based on an intense XUV laser beam propagating through an optically thick resonant target, introducing dispersion profile variations around the resonance both perpendicular to and along the laser propagation direction. The resulting dipole radiation gets spectrally reshaped and becomes more divergent as compared to the original beam in the far field. As an experimental demonstration, the intense-XUV–induced double-peak off-axis structure in the far-field spectrum obtained at the Free-Electron Laser in Hamburg (FLASH) shows indications of the underlying XUV-driven Rabi dynamics and resonant pulse propagation effects. The presented work highlights a ubiquitous phenomenon occurring when an intense laser beam passes through a resonant medium.

He, Yu [Max-Planck-Institut für Kernphysik, Heidel↗

Pulsed laser Rayleigh scattering diagnostic for hydrogen/oxygen rocket exit plane flowfield velocimetry

A Doppler-resolved, pulsed laser Rayleigh scattering diagnostic has been developed to obtain local flowfield velocity measurements at the exit plane of a low thrust hydrogen/oxygen rocket engine operating in a high-altitude test facility. Fiberoptic signal collection was employed to obtain the forescatter and backscatter Doppler shifts necessary to resolve the axial and radial velocity components. A radial profile was obtained by traversing the collection probes along the beam path at the nozzle exit. The results are compared with theoretical predictions from a full Navier-Stokes model (RK/RPLUS). Significant discrepancies between the measured and predicted axial velocity profiles are observed, in terms of both magnitude and character. Radial velocity measurements exhibit excellent agreement with predictions near the centerline but show some departure off-axis. The discrepancies between theory and experiment are potentially the result of enhanced mixing between the core and fuel-film region beyond that predicted, and/or flow stratification between the hydrogen and oxygen injected into the central core region.

Zupanc, Frank J.↗

SU-F-T-511: Feasibility Study of Using Flattening-Filter-Free Photon Beams to Deliver Conventional Flat Beam

Purpose: Various dosimetric benefits such as increased dose rate, and reduced leakage and out of field dose has led to the growth of FFF technology in the clinic. In this study, we concentrate on investigating the feasibility of using flattening-filter-free (FFF) beams to deliver conventional flat beams (CFB), since completely getting rid of the flattening-filter module from the gantry head can not only simplify the gantry design but also decrease the workload on machine maintain and quality assurance. Methods: The sliding window based IMRT technique was utilized to generate the CFB from the FFF beam for various beam configurations on the Elekta Versa HD. The flat beam reproducibility and MU efficiency were compared for each beam configuration among FFF planning, delivery and CFB planning. Results: Compared to the CFB plan, the 3%3mm passing rates of the FFF beams from both measurement and plan are 100% and 95%(or better) for 15×15 cm{sup 2} or smaller field size and for any field size greater than 15×15 cm{sup 2}at 10 cm depth, respectively. The largest discrepancy is about 5% and typically appears at the field shoulder area. The MU increase average was 80% for FFF compared to CFB, however has a minimal impact on treatment delivery time. Conclusion: The ability to deliver conventional flat treatments is not absent when operating in FFF mode. With proper TPS manipulation and beam modulation, FFF mode can achieve reasonable flat profiles and comparable dose coverage as CFB does for various conventional treatment techniques, such as four field box, or long spine treatment techniques. The ability to deliver most clinical treatments from the same treatment unit, will allow for less quality assurance as well as maintenance, and completely eliminate the need for the flattening filter on modern linacs.

60 APPLIED LIFE SCIENCES↗