Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69

Negative feedback regulation between microRNA let-7g and LOX-1 mediated hypoxia-induced PASMCs proliferation

Background: Pulmonary hypertension (PH) is a proliferative disorder associated with enhanced proliferation and suppressed apoptosis of pulmonary artery smooth muscle cells (PASMCs). Our lately study demonstrated that let-7g inhibited hypoxia-induced proliferation of PASMCs via repressing c-myc-Bmi-1-p16 signaling pathway. However, the upstream of let-7g has not yet been fully defined. Previous studies have shown that LOX-1, a target of let-7g, could also regulate the expression of let-7g in human aortic endothelial cells. In this present study, we aimed to investigate whether there is a negative feedback regulation between microRNA let-7g and LOX-1 in hypoxia-induced proliferation of PASMCs. Methods: SD Rats were exposed to hypoxia (10% O{sub 2}, 3 weeks) to induce PH. HE staining was used to evaluate pulmonary artery remodeling. in situ hybridization and immunohistochemistry were performed to assess the expression and distribution of let-7g and LOX-1, respectively. MTS, EDU and flow cytometry were performed to evaluate PASMCs proliferation. Quantitative real-time polymerase chain reaction (qRT-PCR) and Western blotting were conducted to assess the expression of let-7g, LOX-1, calpain-1,-2,-4, and OCT-1. Results: The expression of let-7g was significantly down-regulated in pulmonary arteries of hypoxia-induced PH rats accompanied by pulmonary vascular remodeling, whereas let-7g mimic inhibited hypoxia-induced proliferation of PASMCs and up-regulation of LOX-1 expression. LOX-1 blocking reversed hypoxia-induced down-regulation of let-7g expression. Calpains, protein kinase C and OCT-1 were involved in negative feedback regulation between let-7g and LOX-1. Conclusion: Negative feedback regulation between let-7g and LOX-1 mediated hypoxia-induced proliferation of in PASMCs.

60 APPLIED LIFE SCIENCES↗

TRPV4 is involved in irisin-induced endothelium-dependent vasodilation

Highlights: • Irisin caused an increase in [Ca{sup 2+}]{sub i} due to extracellular Ca{sup 2+} influx rather than Ca{sup 2+} release in endothelial cells. • Pretreatment with TRPV4 channel inhibitor completely abolished irisin-induced increases in [Ca{sup 2+}]{sub i}. • Irisin induced endothelium-dependent vasodilation, however, it had no effect on endothelium-independent vasodilation. • Pretreatment with TRPV4 channel inhibitor fully abrogated irisin-induced vasodilation. Irisin, an exercise-induced myokine, induces conversion of white into brown adipocytes, promoting mitochondrial biogenesis and energy expenditure. Irisin has a vascular protective effect on endothelial function in animals, including humans. Defects in irisin signaling pathways result in endothelial dysfunction in obesity and diabetes. However, the mechanisms underlying the effects of irisin on endothelial function have not been elucidated. Transient receptor potential vanilloid subtype 4 (TRPV4) channels are one of the most important Ca{sup 2+}-permeable cation channels in vascular endothelial cells. In this study, we hypothesized that irisin may induce endothelium-dependent vasodilation by activating Ca{sup 2+} influx into endothelial cells via TRPV4 channels. In primary cultured rat mesenteric artery endothelial cells, irisin caused an increase in [Ca{sup 2+}]{sub i} due to extracellular Ca{sup 2+} influx rather than release from Ca{sup 2+} stores. Moreover, irisin-induced increases in [Ca{sup 2+}]{sub i} were completely abolished by a TRPV4 inhibitor. In addition, irisin induced endothelium-dependent vasodilation of rat mesenteric arteries. However, irisin had no effect on endothelium-independent vasodilation. Furthermore, irisin-induced vasodilation was fully abolished in the presence of a TRPV4 inhibitor, indicating the involvement of TRPV4 channels in endothelium-dependent vasodilation. This study provides the first evidence that irisin-induced endothelium-dependent vasodilation is related to the stimulation of extracellular Ca{sup 2+} influx via TRPV4 channels in rat mesenteric arteries.

60 APPLIED LIFE SCIENCES↗

Fibroblast growth factor 21 attenuates hypoxia-induced pulmonary hypertension by upregulating PPARγ expression and suppressing inflammatory cytokine levels

Highlights: • FGF21 Attenuates Hypoxia-induced Pulmonary Hypertension as a Potential drug. • FGF21 may Inhibit Vascular Remodeling Through Suppressing PASMCs Proliferation. • FGF21 Upregulates PPARγ Expression and Inhibits Inflammatory Cytokines. Hypoxia-induced pulmonary hypertension (HPH) is a progressive disease characterized by a sustained, elevated pulmonary arterial pressure and vascular remodeling. The latter pathogenesis mainly involves overproliferation of pulmonary artery smooth muscle cells (PASMCs). Fibroblast growth factor 21 (FGF21) has recently emerged as a novel regulator that prevents cardiac hypertrophic remodeling. However, its possible role in pulmonary remodeling remains unclear. The activation of peroxisome proliferator activated receptor γ (PPARγ) is reported to attenuate HPH by suppressing proliferative signals. Loss of PPARγ in the lung contributes to abnormal proliferation of PASMCs. FGF21 is a key regulator of PPARγ activity in adipocytes, but its role has not been elucidated in PASMCs. Therefore, we hypothesized that FGF21 may confer therapeutic effects in HPH by upregulating the expression of PPARγ. Sprague-Dawley rats were exposed to hypoxia and treated with FGF21 for 4 weeks. In parallel, hypoxic conditions and FGF21 were administered to rat PASMCs for 48 h. FGF21 attenuated the hypoxia-induced elevation in mean pulmonary arterial pressure (mPAP), right ventricular hypertrophy (RVH), medial thickening and overproliferation of PASMCs. Furthermore, FGF21 abrogated the reductions in PPARγ expression and increases in TNF-α, IL-1 and IL-6 levels in PASMC culture media. Collectively, these results demonstrate that FGF21 could potentially attenuate the pathogenic derangements of HPH by targeting PPARγ and inflammatory cytokines.

60 APPLIED LIFE SCIENCES↗

Defective autophagy in vascular smooth muscle cells enhances atherosclerotic plaque instability

Highlights: • We investigated the role of autophagy in SMCs on plaque instability in vivo. • We conducted to form a tandem stenosis in the carotid artery. • Thrombus was frequently found in KO mice. • Plaque hemorrhage was frequently found in KO mice. • Defective autophagy in SMCs enhances plaque instability. Autophagy is considered as an evolutionarily conserved cellular catabolic process. Defective autophagy has been implicated in various human diseases, including cardiovascular diseases. Recently, we and others demonstrated that defective autophagy in vascular smooth muscle cells (SMCs) promotes the progression of atherosclerosis. In this study, we investigated the role of autophagy in SMCs on plaque instability in vivo. We generated mice with a defect atg7in which is an essential gene for autophagy, in SMCs by crossing Atg7{sup f/f} mice with transgelin (Tagln) Cre{sup +/0} mice (Atg7cKO). Then, Atg7cKO and apolipoprotein E (apoe)-deficient (apoeKO) mice were crossed to generate Atg7cKO:apoeKO mice. To generate a mouse model of plaque instability, we conducted to form a tandem stenosis in the carotid artery of Atg7cKO:apoeKO mice and their controls (apoeKO mice) at the age of 10 weeks. At 5 weeks after surgery, the percentage of cross-sectional stenosis area in the operated common carotid artery of Atg7cKO:apoeKO mice was significantly higher than that in apoeKO mice. In addition, thrombus, which was not observed in apoeKO mice, was frequently found in Atg7cKO:apoeKO mice. Furthermore, the number of Berlin blue staining-positive areas, which indicated intraplaque hemorrhage, was significantly higher in Atg7cKO:apoeKO mice than in control apoeKO mice. Taken together, our data suggest that defective autophagy in SMCs enhances plaque instability and the risk of plaque rupture.

60 APPLIED LIFE SCIENCES↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Development and Validation of a Heart Atlas to Study Cardiac Exposure to Radiation Following Treatment for Breast Cancer

Purpose: Cardiac toxicity is an important sequela of breast radiotherapy. However, the relationship between dose to cardiac structures and subsequent toxicity has not been well defined, partially due to variations in substructure delineation, which can lead to inconsistent dose reporting and the failure to detect potential correlations. Here we have developed a heart atlas and evaluated its effect on contour accuracy and concordance. Methods and Materials: A detailed cardiac computed tomography scan atlas was developed jointly by cardiology, cardiac radiology, and radiation oncology. Seven radiation oncologists were recruited to delineate the whole heart, left main and left anterior descending interventricular branches, and right coronary arteries on four cases before and after studying the atlas. Contour accuracy was assessed by percent overlap with gold standard atlas volumes. The concordance index was also calculated. Standard radiation fields were applied. Doses to observer-contoured cardiac structures were calculated and compared with gold standard contour doses. Pre- and post-atlas values were analyzed using a paired t test. Results: The cardiac atlas significantly improved contour accuracy and concordance. Percent overlap and concordance index of observer-contoured cardiac and gold standard volumes were 2.3-fold improved for all structures (p < 0.002). After application of the atlas, reported mean doses to the whole heart, left main artery, left anterior descending interventricular branch, and right coronary artery were within 0.1, 0.9, 2.6, and 0.6 Gy, respectively, of gold standard doses. Conclusions: This validated University of Michigan cardiac atlas may serve as a useful tool in future studies assessing cardiac toxicity and in clinical trials which include dose volume constraints to the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of external beam treatment techniques for T1-2, N0, M0 glottic cancers

The purpose of this study was to compare 4 different external beam radiation therapy treatment techniques for the treatment of T1-2, N0, M0 glottic cancers: traditional lateral beams with wedges (3D), 5-field intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and proton therapy. Treatment plans in each technique were created for 10 patients using consistent planning parameters. The photon treatment plans were optimized using Philips Pinnacle{sub 3} v.9 and the IMRT and VMAT plans used the Direct Machine Parameter Optimization algorithm. The proton treatment plans were optimized using Varian Eclipse Proton v.8.9. The prescription used for each plan was 63 Gy in 28 fractions. The contours for spinal cord, right carotid artery, left carotid artery, and normal tissue were created with respect to the patient's bony anatomy so that proper comparisons of doses could be made with respect to volume. An example of the different isodose distributions will be shown. The data collection for comparison purposes includes: clinical treatment volume coverage, dose to spinal cord, dose to carotid arteries, and dose to normal tissue. Data comparisons will be displayed graphically showing the maximum, mean, median, and ranges of doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

HMGA2 contributes to vascular development and sprouting angiogenesis by promoting IGFBP2 production

Highlights: • Our findings demonstrates that HMGA2 promotes central arteries formation in zebrafish. • HMGA2 induces vascular development through modulation of IGFBP2 whatever in vivo or in vitro. • The mRNA expressions of HMGA2 and IGFBP2 increased significantly in peripheral blood of Hemangioma patients. • HMGA2-IGFBP2 are promising candidates towards therapeutical vascularization in vascular diseases like Hemangioma. Angiogenesis is the process by which new blood vessels form from preexisting vessels and regulates the processes of embryonic development, wound healing and tumorigenesis. HMGA2 is involved in the occurrence of several cancers, but its biological role and the exact downstream genes involved in vascular development and sprouting angiogenesis remain largely unknown. Here, we first found that HMGA2 knockdown in zebrafish embryos resulted in defects of central artery formation. RNA sequencing revealed that IGFBP2 was significantly downregulated by interference with HMGA2, and IGFBP2 overexpression reversed the inhibition of brain vascular development caused by HMGA2 deficiency. In vitro, we further found that HMGA2 knockdown blocked the migration, tube formation and branching of HUVECs. Similarly, IGFBP2 protein overexpression attenuated the impairments induced by HMGA2 deficiency. Moreover, the promotion of angiogenesis by HMGA2 overexpression was verified in a Matrigel plug assay. We next found that HMGA2 bound directly to a region in the IGFBP2 promoter and positively regulated IGFBP2 expression. Interestingly, the mRNA expression levels of HMGA2 and IGFBP2 were increased significantly in the peripheral blood of hemangioma patients, indicating that overexpression of HMGA2 and IGFBP2 results in vessel formation, consistent with the results of the in vivo and in vitro experiments. In summary, our findings demonstrate that HMGA2 promotes central artery formation by modulating angiogenesis via IGFBP2 induction.

60 APPLIED LIFE SCIENCES↗

Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of Vasa Vasorum Density in Multi-Slice Computed Tomographic Coronary Angiograms: Role of Computed Tomographic Image Voxel Size

This study is motivated by the possibility of using computed tomography (CT) to detect early coronary atherosclerosis by the increased CT values within the arterial wall resulting from vasa vasorum proliferation. Coronary arteries (n = 5) with early atherosclerotic changes were injected with Microfil and scanned (micro-CT). Noise was added to the CT projection data sets (to represent the radiation exposure of current clinical CT scanners) and then reconstructed to generate 3-dimensional images at different voxel sizes. Higher CT values were detected because of contrast agent in vasa vasorum if voxel size was less than (150 {micro}m){sup 3}. Contrast in the main lumen increased the CT values dramatically at voxels greater than (100 {micro}m){sup 3}, whereas CT values of the same specimen without contrast in the main lumen remained constant. Voxel sizes less than (200 {micro}m){sup 3} are needed to quantitate arterial wall opacification due to vasa vasorum proliferation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Relationship of creatine kinase, aspartate aminotransferase, lactate dehydrogenase, and proteinuria to cardiomyopathy in the owl monkey (Aotus vociferans)

The purpose of this study was to determine serum reference values for crea- tine kinase (CK), aspartate aminotransferase (AST), and lactate dehydroge- nase (LDH) in captive-born and wild-caught owl monkeys to assess their usefulness for diagnosing myocardial disease. Urine samples were also collected and semi-quantitative tests performed. There was no statistically significant difference between CK, AST, and LDH when comparing both groups. However, when comparing monkeys with proteinuria to those without proteinuria, a statistically significant difference in CK value was observed (P = 0.021). In addition, the CK/AST ratio revealed that 29% of the animals included in this study had values suggesting cardiac infarction. Grossly, cardiac concentric hypertrophy of the left ventricle and small, pitted kidneys were the most common findings. Microscopically, myocardial fibrosis, contraction band necrosis, hypertrophy and hyperplasia of coronary arteries, medium-sized renal arteries, and afferent glomerular arteriolae were the most significant lesions, along with increased mesangial matrix and hypercellularity of glomeruli, Bowman’s capsule, and peritubular space fibroplasia. These findings suggest that CK, AST, and LDH along with urinalysis provide a reliable method for diagnosing cardiomyopathies in the owl monkey. In addition, CK/AST ratio, proteinuria, and the observed histological and ultrastructural changes suggest that Aotus vociferans suffer from arterial hypertension and chronic myocardial infarction.

59 BASIC BIOLOGICAL SCIENCES↗

SU-D-18C-02: Feasibility of Using a Short ASL Scan for Calibrating Cerebral Blood Flow Obtained From DSC-MRI

Purpose: This study aimed to evaluate the feasibility of using a short arterial spin labeling (ASL) scan for calibrating the dynamic susceptibility contrast- (DSC-) MRI in a group of patients with internal carotid artery stenosis. Methods: Six patients with unilateral ICA stenosis enrolled in the study on a 3T clinical MRI scanner. The ASL-cerebral blood flow (-CBF) maps were calculated by averaging different number of dynamic points (N=1-45) acquired by using a Q2TIPS sequence. For DSC perfusion analysis, arterial input function was selected to derive the relative cerebral blood flow (rCBF) map and the delay (Tmax) map. Patient-specific CF was calculated from the mean ASL- and DSC-CBF obtained from three different masks: (1)Tmax< 3s, (2)combined gray matter mask with mask 1, (3)mask 2 with large vessels removed. One CF value was created for each number of averages by using each of the three masks for calibrating the DSC-CBF map. The CF value of the largest number of averages (NL=45) was used to determine the acceptable range(< 10%, <15%, and <20%) of CF values corresponding to the minimally acceptable number of average (NS) for each patient. Results: Comparing DSC CBF maps corrected by CF values of NL (CBFL) in ACA, MCA and PCA territories, all masks resulted in smaller CBF on the ipsilateral side than the contralateral side of the MCA territory(p<.05). The values obtained from mask 1 were significantly different than the mask 3(p<.05). Using mask 3, the medium values of Ns were 4(<10%), 2(<15%) and 2(<20%), with the worst case scenario (maximum Ns) of 25, 4, and 4, respectively. Conclusion: This study found that reliable calibration of DSC-CBF can be achieved from a short pulsed ASL scan. We suggested use a mask based on the Tmax threshold, the inclusion of gray matter only and the exclusion of large vessels for performing the calibration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Direct exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.

60 APPLIED LIFE SCIENCES↗

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Rationale for and Preliminary Results of Proton Beam Therapy for Mediastinal Lymphoma

Purpose: To evaluate the potential of three-dimensional proton beam therapy (3D-PBT) for reducing doses to normal structures in patients with mediastinal lymphomas compared with conventional photon radiation therapy (RT). Methods and Materials: We treated 10 consecutive patients with mediastinal masses from lymphomas with 3D-PBT between July 2007 and February 2009 to 30.6-50.4 cobalt-Gray equivalents (CGE). Of those patients, 7 had primary refractory or recurrent disease, and 8 had Hodgkin lymphoma. Dosimetric endpoints were compared with those from conventional RT plans. Results: PBT delivered lower mean doses to the lung (6.2 vs. 9.5 Gy), esophagus (9.5 vs. 22.3 Gy), and heart (8.8 vs. 17.7 Gy) but not the breasts (5.9 vs. 6.1 Gy) than did conventional RT. Percentages of lung, esophagus, heart, and coronary artery (particularly the left anterior descending artery) volumes receiving radiation were consistently lower in the 3D-PBT plans over a wide range of radiation doses. Of the 7 patients who had residual disease on positron emission tomography before PBT, 6 (86%) showed a complete metabolic response. Conclusions: In patients with mediastinal lymphomas, 3D-PBT produced significantly lower doses to the lung, esophagus, heart, and coronary arteries than did the current conventional RT. These lower doses would be expected to reduce the risk of late toxicities in these major organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 1D–0D–3D coupled model for simulating blood flow and transport processes in breast tissue

In this work, we present mixed dimensional models for simulating blood flow and transport processes in breast tissue and the vascular tree supplying it. These processes are considered, to start from the aortic inlet to the capillaries and tissue of the breast. Large variations in biophysical properties and flow conditions exist in this system necessitating the use of different flow models for different geometries and flow regimes. In total, we consider four different model types. First, a system of 1D nonlinear hyperbolic partial differential equations (PDEs) is considered to simulate blood flow in larger arteries with highly elastic vessel walls. Second, we assign 1D linearized hyperbolic PDEs to model the smaller arteries with stiffer vessel walls. The third model type consists of ODE systems (0D models). It is used to model the arterioles and peripheral circulation. Finally, homogenized 3D porous media models are considered to simulate flow and transport in capillaries and tissue within the breast volume. Sink terms are used to account for the influence of the venous and lymphatic systems. Combining the four model types, we obtain two different 1D–0D–3D coupled models for simulating blood flow and transport processes: The first model results in a fully coupled 1D–0D–3D model covering the complete path from the aorta to the breast combining a generic arterial network with a patient specific breast network and geometry. The second model is a reduced one based on the separation of the generic and patient specific parts. The information from a calibrated fully coupled model is used as inflow condition for the patient specific sub-model allowing a significant computational cost reduction. Several numerical experiments are conducted to calibrate the generic model parameters and to demonstrate realistic flow simulations compared to existing data on blood flow in the human breast and vascular system. Moreover, we use two different breast vasculature and tissue data sets to illustrate the robustness of our reduced sub-model approach.

multiscale blood flow models↗

Investigating the Role of VR in a Simulation-Based Medical Planning System for Coronary Interventions

Virtual reality (VR) based computational fluid dynamics (CFD) simulations are emerging as a viable solution to guide complex surgical or invasive procedures, such as percutaneous coronary intervention (PCI), as they enable a realistic first-person experience of underlying patient anatomy and physiology. Realistic VR experience can be assessed by immersion, an objective VR property. However, it remains unclear how immersion influences virtual PCI procedures and what level of immersion is required. This study answers both these questions by evaluating the application of a CFD-based VR system and comparing semi-immersive and fully immersive VR displays. Nine patient-specific arterial models were simulated using CFD and used to conduct a quantitative user evaluation (n = 31) with both types of VR displays. The findings of this study reveal that VR immersion significantly improves the accuracy of simulated stent placement in complex arterial geometries, relative to traditional desktops with no immersion (p < 0.05). Higher accuracy is noted by the use of semi-immersive VR display, which offers higher display fidelity as compared to the fully immersive VR display (p < 0.05). Interestingly, CFD data mapped on to arterial geometries strongly influences the location of stent placement. This finding is demonstrated by the lack of significant accuracy deviation between the two immersive displays when CFD data is shown. This study provides compelling evidence that a CFD-based VR system rendered on semi-immersive displays can enable more accurate and efficient stent placement.

Vardhan, Madhurima↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗