Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vulnerabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms

Grid-scale battery energy storage systems (BESSs) are vulnerable to false data injection attacks (FDIAs), which could be used to disrupt state of charge (SoC) estimation. Inaccurate SoC estimation has negative impacts on system availability, reliability, safety, and the cost of operation. In this article a combination of a Cumulative Sum (CUSUM) algorithm and an improved input noise-aware extended Kalman filter (INAEKF) is proposed for the detection and identification of FDIAs in the voltage and current sensors of a battery stack. The series-connected stack is represented by equivalent circuit models, the SoC is modeled with a charge reservoir model and the states are estimated using the INAEKF. Further, the root mean squared error of the states’ estimation by the modified INAEKF was found to be superior to the traditional EKF. By employing the INAEKF, this article addresses the research gap that many state estimators make asymmetrical assumptions about the noise corrupting the system. Additionally, the INAEKF estimates the input allowing for the identification of FDIA, which many alternative methods are unable to achieve. The proposed algorithm was able to detect attacks in the voltage and current sensors in 99.16% of test cases, with no false positives. Utilizing the INAEKF compared to the standard EKF allowed for the identification of FDIA in the input of the system in 98.43% of test cases.

25 ENERGY STORAGE↗

A Framework to Design Consumer-Centric Operational Strategies for Resilience Enhancement

Extreme temperature-related events like heat waves or cold snaps can significantly stress the power distribution grid as electricity demand spikes leading to brownouts or blackouts if not managed properly. In addition, such extreme events can exacerbate inequity, with vulnerable populations (for example, houses with poor insulation, located in non-critical zones, and lack of local resources) at greater risk. There is a growing deployment of distribution systems automation technologies such as advanced metering infrastructure, sensors, and automated control systems to enhance the visibility of the entire distribution grid while meeting resilience objectives. Here, this paper proposes a framework for investigating how automation can improve the distribution system's resilience and ensure customers' health and safety during such extremes. The proposed framework's efficacy will be demonstrated for the Electricity Reliability Council of Texas (ERCOT) during winter storm Uri with varying levels of distribution automation technologies such as feeder isolation using smart switches, remote outage signals using advanced meters, and comfort-aware outage using advanced analytics and communication. Simulation results show that an outage strategy involving advanced grid technology and communication can reduce the occupant exposure to severe cold by 93% and, simultaneously, reduce expected energy not served by 73.2% when compared against feeder isolation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

DFF Layout Variations in CMOS SOI—Analysis of Hardening by Design Options

Four D flip-flop (DFF) layouts were created from the same schematic in Sandia National Laboratories’ CMOS7 silicon-on-insulator (SOI) process. Single-event upset (SEU) modeling and testing showed an improved response with the use of shallow (not fully bottomed) N-type metal-oxide-semiconductor field-effect transistors (NMOSFETs), extending the size of the drain implant and increasing the critical charge of the transmission gates in the circuit design and layout. This research also shows the importance of correctly modeling nodal capacitance, which is a major factor determining SEU critical charge. Accurate SEU models enable the understanding of the SEU vulnerabilities and how to make the design more robust.

42 ENGINEERING↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

A Double-side Cooled SiC MOSFET Power Module with Sintered-silver Interposers: I. Design, Simulation, Fabrication, and Performance Characterization

Planar, double-side cooled power modules are emerging in electric-drive inverters because of their low profile, better heat extraction, and lower package parasitic inductances. However, there is still concern about their reliability due to the rigid interconnection between the device chips and two substrates of the power module. In this paper, a porous interposer made of low-temperature sintered silver is introduced to reduce the thermo-mechanical stresses in the module. A double-side cooled half-bridge module consisting of two 1200 V, 149 A SiC MOSFETs was designed, fabricated, and characterized. By using the sintered-Ag instead of solid copper interposers, our simulation results showed that at a total power loss of 200 W, the thermo-mechanical stress at the most vulnerable interfaces (interposer-attach layer) was reduced by 42 % and in the SiC MOSFET by 50 % with a trade-off of only 3.6 % increase in junction temperature. The sintered-Ag interposers were readily fabricated into desired dimensions without post-machining and did not require any surface finishing for die-bonding and substrate interconnection by silver sintering. Here, the porous interposers were also deformable under a low force or pressure, which helped to accommodate chip thickness and/or substrate-to-substrate gap variations in the planar module structure, thus simplifying module fabrication. Experimental results on the electrical performance of the fabricated SiC modules validated the success of using the porous silver interposers for fabricating planar, double-side cooled power modules.

42 ENGINEERING↗

Theoretical Analysis and Experimental Validation of Flying-Capacitor Multilevel Converters Under Short-Circuit Fault Conditions

Addressing the increasing demand for high- efficiency and high-power-density converters, the flying-capacitor multilevel converter has shown itself as a promising topology. A key advantage of this topology is the reduced voltage rating of the switches, though also makes it vulnerable to device failure during short-circuit conditions. Despite large interest in fault-tolerant operation of these converters, alongside detailed descriptions of flying capacitor balancing, little research has focused on the converter short-circuit fault analysis, which may cause a switch failure if not properly designed for. Therefore, this work presents a comprehensive model describing the large- signal short-circuit switching behavior of a general N -level flying- capacitor multilevel converter. Highly simplified models used to predict the evolution of the switch current and voltage stress during the fault are proposed, targeted at practicing engineers for conservative design guidelines. These models are used to determine the critical time for remedial action of the converter before reaching some predefined maximum conditions. A 2-to-10- level fully-configurable flying-capacitor multilevel converter and a fault circuit hardware prototype are used to experimentally perform different short-circuit tests that show a good match to the measured behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Framework for Analysis and Quantification of Wide-Area Control Resilience for Power Systems

Wide-area control helps damp the inter-area oscillations in modern power systems. However, compared to traditional local control, it is more vulnerable to cyber attacks due to its dependence on remote real-time-communicated measurements. In this paper, a formal mathematical framework for analyzing resilience of various wide-area controllers under adversarial scenarios is proposed. A novel resilience index based on the $\H_2$ norm of the post-attack closed-loop system is defined. Computation of such an index is, in general, challenging due to the combinatorial nature of the attack profiles and the bilinear nature of the problem. To address these difficulties, a gradient-based path-following-like solution is developed in this paper to solve a relaxed version of the original non-convex problem. Case studies on IEEE 39-bus system are performed to demonstrate the usage of the proposed framework.

Marinovici, Laurentiu D.↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Employing Interacting Qubits for Distributed Microgrid Control

To empower flexible and scalable operations, distributed control of multi-inverter microgrids, based on classical communication networks among distributed energy resources, has attracted considerable attention as it can guarantee synchronization and provide suitable remedies to the problem of improper power sharing. Notwithstanding this, resilience of the current schemes on classical communication makes microgrids vulnerable to cyber attacks. Inspired by recent revolutionary breakthroughs in quantum communication, in this paper, we devise a novel synchronization mechanism. We extend the synchronization framework utilized in distributed control algorithms to networks of quantum systems by generating pinning terms and coupling mechanism for the new synchronization rule via exploiting proper quantum jump operators and observables, and show that the quantum system will converge to a time-variant target state. Our devised quantum distributed controller (QDC) gives rise to a novel quantum communication scheme for distributed control of microgrids and enables microgrids to exploit the state-of-the-art quantum communication frameworks as communication infrastructure. Finally, test results on two representative AC and DC networked microgrids validate the efficacy and universality of the quantum distributed control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Robust Power System Stability Assessment Against Adversarial Machine Learning-Based Cyberattacks via Online Purification

The increasing complexity associated with renewable generation brings more challenges to power system stability assessment (SA). Data-driven approaches based on machine learning (ML) techniques for stability assessment have received significant research interest and shown their promising performance. However, ML-based models are recognized to be vulnerable to adversarial disturbances, where a slight perturbation to power system measurements could lead to unacceptable errors. To address this issue, this paper develops a novel lightweight mitigation strategy, i.e., robust online stability assessment (ROSA), to enhance the ML-based assessment model against both white-box and the black-box adversarial disturbances (i.e., purification) in the online implementation. The ROSA involves a supervised learning-based module for the primary stability assessment and a self-supervised learning-based module. Further, the two modules are trained jointly with different objective (loss) functions and implemented in sequence. A suitable purification objective and various time-series data augmentation methods are designed for SA applications to tackle adversarial disturbances adaptively. Case studies are performed, and the comparative results have clearly illustrated the competitive, robust accuracy against various adversarial scenarios and verified the effectiveness of the proposed online purification strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Probabilistic Resilience-Oriented Assessment Approach for Transmission Networks Under Wildfires

The rising threat of wildfires poses significant challenges to power transmission networks, particularly in areas prone to such disasters. Traditional approaches for wildfire risk assessment neglect some potential wildfire scenarios. Here, this paper introduces a probabilistic resilience-oriented assessment approach for power transmission networks to address this gap. Initially, a probabilistic wildfire model is developed to capture uncertainties in ignition, intensity, and fire spread. Next, a spatiotemporal fragility model is constructed to assess the impact of wildfires on transmission corridors, incorporating Thermal Aging (TA) and Dynamic Thermal Rate (DTR) change. Finally, a comprehensive resilience metric is defined to evaluate system performance, leveraging the fragility model to determine component and system-level resilience. The approach employs a combinatorial enumeration method to generate potential wildfire scenarios, enhanced by an impact-increment-based state enumeration (IISE) method for computational efficiency. The proposed method provides critical insights for identifying system vulnerabilities and developing robust strategies to protect transmission networks from wildfires. The efficacy of this approach is validated through extensive scenarios of the RTS-GMLC system across Southern California, Nevada and Arizona.

Vahedi, Soroush [Univ. of Connecticut, Storrs, CT ↗

Programmable Quantum Networked Microgrids

Quantum key distribution (QKD) provides a potent solution to securely distribute keys for two parties. However, QKD itself is vulnerable to denial of service (DoS) attacks. A flexible and resilient QKD-enabled networked microgrids (NMs) architecture is needed but does not yet exist. In this article, we present a programmable quantum NMs (PQNMs) architecture. It is a novel framework that integrates both QKD and software-defined networking (SDN) techniques capable of enabling scalable, programmable, quantum-engineered, and ultra-resilient NMs. Equipped with a software-defined adaptive post-processing approach, a two-level key pool sharing strategy and an SDN-enabled event-triggered communication scheme, these PQNMs mitigate the impact of DoS attacks through programmable post-processing and secure key sharing among QKD links, a capability unattainable using existing technologies. Through comprehensive evaluations, we validate the benefits of PQNMs and demonstrate the efficacy of the presented strategies under various circumstances. Extensive results provide insightful resources for building QKD-enabled NMs in practice.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗