Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

EVAP: A two-photon imaging tool to study conformational changes in endogenous Kv2 channels in live tissues

A primary goal of molecular physiology is to understand how conformational changes of proteins affect the function of cells, tissues, and organisms. Here, we describe an imaging method for measuring the conformational changes of the voltage sensors of endogenous ion channel proteins within live tissue, without genetic modification. We synthesized GxTX-594, a variant of the peptidyl tarantula toxin guangxitoxin-1E, conjugated to a fluorophore optimal for two-photon excitation imaging through light-scattering tissue. We term this tool EVAP (Endogenous Voltage-sensor Activity Probe). GxTX-594 targets the voltage sensors of Kv2 proteins, which form potassium channels and plasma membrane–endoplasmic reticulum junctions. GxTX-594 dynamically labels Kv2 proteins on cell surfaces in response to voltage stimulation. To interpret dynamic changes in fluorescence intensity, we developed a statistical thermodynamic model that relates the conformational changes of Kv2 voltage sensors to degree of labeling. We used two-photon excitation imaging of rat brain slices to image Kv2 proteins in neurons. We found puncta of GxTX-594 on hippocampal CA1 neurons that responded to voltage stimulation and retain a voltage response roughly similar to heterologously expressed Kv2.1 protein. Our findings show that EVAP imaging methods enable the identification of conformational changes of endogenous Kv2 voltage sensors in tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Scaling of pulsed nanosecond capillary plasmas at different specific energy deposition

Nano-second, capillary discharges (nCDs) are unique plasma sources in their ability to sustain high specific energy deposition ω dep approaching 10 eV/molecule in molecular gases. This high energy loading on short timescales produces both high plasma densities and high densities of molecular exited states. These high densities of electrons and excited states interact with each other during the early afterglow through electron collision quenching and associative ionization. In this paper we discuss results from a two-dimensional computational investigation of a nCD sustained in air at a pressure of 28.5 mbar and with a voltage amplitude 20 kV. Discharges were investigated for two circuit configurations—a floating low voltage electrode and with the low voltage electrode connected to ground through a ballast resistor. The first configuration produced a single ionization wave from the high to low voltage electrode. The second produced converging ionization waves beginning at both electrodes. With a decrease of the tube radius, the velocity of the ionization fronts decreased while the shape of the ionization wave changed from the electron density being distributed smoothly in the radial direction, to being hollow shaped where there is a higher electron density near the tube wall. For sufficiently small tubes, the near-wall maxima merge to have the higher density on the axis of the capillary tube. In the early afterglow, the temporal and radial behavior of the N 2 (C 3 Π u ) density is a sensitive function of ω dep due to electron collision quenching. Finally, these trends indicate that starting from ω dep $\geqslant$ 0.3 eV/molecule, it is necessary to take into account interactions of electrons with electronically excited species during the discharge and early afterglow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Zonal Volt/VAR Control Mechanism for High PV Penetration Distribution Systems

This paper presents a zonal Volt/VAR control scheme for regulating voltage in unbalanced 3-phase distribution systems using inverter-based resources (IBR). First, the dependency between nodal voltage changes and IBR reactive power injections is derived via voltage sensitivity studies. Then, a fast-incremental clustering method is used to divide the distribution circuit into weakly-coupled zones based on correlations between nodal voltage sensitivities. The weak-coupling allows the voltage to be regulated independently within each zone using a rule-based voltage controller to dispatch IBR for voltage corrections. Simulation results on actual distribution feeder show that the proposed zone-based Volt/VAR control method maintains system voltages within their operational limits while reducing the runtime of the Volt/VAR controller from tens of second to a couple of milliseconds compared with centralized, optimization-based Volt/VAR control methods.

Alrushoud, Asmaa↗

A Medium-/Low-Voltage Joint State Estimator Through Linear Uncertainty Propagation

Traditionally, distribution system state estimations (DSSE) are challenged by the lack of measurements at both primary and secondary sides of the system. The widely available cable television (CATV) voltage sensors installed in low-voltage (LV) networks bring opportunities to achieve higher quality DSSE covering a broader area of the distribution network. This study proposes a medium-/low-voltage (MV/LV) joint distribution system state estimation approach using the untapped CATV measurements. It aims at addressing the need for system situational awareness at the grid edge while improving the estimation accuracy at both the primary and secondary sides compared to its disjointed counterpart. Linearized measurement functions and boundary condition uncertainty propagation rules are derived to ensure the computational efficiency and accuracy of the joint state estimator. Numerical experiments are conducted on an IEEE test feeder to demonstrate the efficacy of the proposed method and the value of CATV measurements.

joint state estimation↗

Characteristics and mathematical modeling of apple slice drying in an electrohydrodynamic system with a needle‐plate electrode

Abstract The drying of apple slices in an electrohydrodynamic (EHD) system with a needle‐plate electrode was characterized and mathematically modeled at voltages of 30, 40, and 50 kV and with distances between needles of 5, 6, and 7 cm. The results showed that the drying rate, effective water diffusion coefficient, and rehydration ratio of the apple slices, and specific energy consumption of drying, all increased with increasing voltage. Initially, there was a period when the drying rate was approximately constant in the low‐voltage EHD, but not in the high voltage conditions. At the same voltage, the drying rate was highest when the distance between needles was 6 cm. The voltage and distance between needles had a significant ( p < .05) interactive effect on the effective water diffusion coefficient and specific energy consumption, but not on the rehydration ratio. General mathematical models for drying can be used to represent the drying behavior of apple slices. The Midilli and Kucuk model and the Logarithmic model had the best fits, with correlation coefficients of 0.998803 and 0.998267, respectively. Predictive functions for the moisture ratio of apple slices based on voltage and distance between needles were established and verified. The results indicated that the Logarithmic model could more accurately predict the moisture ratio of apple slices dried using the EHD method. Practical Applications As a new drying technology, electrohydrodynamic (EHD) drying has unequaled advantages. According to the results, using the appropriate voltage and distance between needles improves not only drying efficiency, but also the rehydration ratio of apple slices, which reflects the quality of dried products. The Logarithmic model can accurately predict the EHD drying behavior of apple slices, which is of great significance in optimizing actual production.

Li, Bowen↗

High-Current Density Durability of Pt/C and PtCo/C Catalysts at Similar Particle Sizes in PEMFCs

The durability of carbon supported PtCo-alloy based nanoparticle catalysts play a key role in the longevity of proton-exchange membrane fuel cells (PEMFC) in electric vehicle applications. To improve its durability, it is important to understand and mitigate the various factors that cause PtCo-based cathode catalyst layers (CCL) to lose performance over time. These factors include i) electrochemical surface area (ECSA) loss, ii) specific activity loss, iii) H + /O 2 -transport changes and iv) Co 2+ contamination effects. We use a catalyst-specific accelerated stress test (AST) voltage cycling protocol to compare the durability of Pt and PtCo catalysts at similar average nanoparticle size and distribution. Our studies indicate that while Pt and PtCo nanoparticle catalysts suffer from similar magnitudes of electrochemical surface area (ECSA) losses, PtCo catalyst shows a significantly larger cell voltage loss at high current densities upon durability testing. The distinctive factor causing the large cell voltage loss of PtCo catalyst appears to be the secondary effects of the leached Co 2+ cations that contaminate the electrode ionomer. A 1D performance model has been used to quantify the cell voltage losses arising from various factors causing degradation of the membrane electrode assembly (MEA).

08 HYDROGEN↗

Time-Resolved Spectroscopy of Insulator-Metal Transitions: Exploring Low-Energy Dynamics in Strongly Correlated Systems. Final Report

Transition metal oxides (TMOs) have attracted much attention in recent years. The strong coupling between charge, spin, and orbital degrees of freedom creates novel functional properties. The research at the interplay between ferromagnetism, ferroelectricity and conductivity provides a promising way to the development of future spintronic devices. The interface characterization of multifunctional oxide heterostructures is crucial to understand deeply the magnetic response, spin injection and spin transport. In year one, we characterized optically the magnetic property with the method of magnetization-induced second-harmonic generation (MSHG), which is a sensitive technique to selectively probe the interface where the spatial inversion symmetry is broken. The interface of n-type BaTiO 3 (BTO)/La 0.67 Sr 0.33 MnO 3 (LSMO) forms a Schottky barrier and displays a good diode effect. By applying an external electric field across the sample, we observe the magnetoelectric (ME) coupling effect to modulate the interface magnetization. The voltage dependent magnetic contrast sharply vanishes at positive voltage (applied to LSMO contact) and reveals a ferromagnetic (FM)-to- antiferromagnetic (AFM) transition occurring at the interface, while the magneto-optic Kerr effect (MOKE) indicates that the bulk property is not affected. The strain mediated mechanism and ferroelectric (FE) polarization induced charge medicated mechanism are both discussed, but they do not play an important role in the observed magnetization transition. A new mechanism is proposed - the injected minority spins through strong Hund's interaction with the local magnetic moments at positive voltage weaken the double-exchange interaction of nearby Mn e g electrons, thereby reducing the ferromagnetic (FM) ordering. The dominant superexchange interaction of localized t 2g electrons finally leads to the AFM configuration. By reducing the electron carrier concentration of BTO, a positive voltage shift of the transition is observed. The oxygen richer sample with lower carrier concentration requires a higher voltage to increase the hole doping level of LSMO to induce the interfacial AFM phase. By inserting a thin (1nm) La 0.5 Ca 0.5 MnO 3 layer between BTO and LSMO, the interface magnetic response from LSMO is enhanced. In year two, a non-multiferroic heterostructure SrTiO 3 (STO)/ La 0.5 Ca 0.5 MnO 3 (LCMO)/La 0.67 Sr 0.33 MnO 3 (LSMO) was studied. In this system, the interface FM-AFM transition is observed at negative voltage. The STO layer may act as a hole-donating layer, which induces the hole transfer to LSMO making it overdoped, while the LCMO interlayer at the 0.5 hole doping level displays complicated CE type AFM phase. Thus the AFM phase is dominant at the interface and electron accumulation is required to induce the FM phase by applying a negative voltage. For oxygen rich sample, the magnetic MSHG loop reappears at high positive voltage (around +2.5 V). At high doping level (x > 0.5), LSMO exhibits A-type AFM order, consisting of AFM superexchange coupling between adjacent layers and intralayer FM double-exchange coupling. The less tensile strain of STO and LSMO due to a smaller lattice mismatch as compared to BTO would result in a weaker interlayer coupling . Thus, interfacial A-type AFM order can occur in STO/LCMO/LSMO heterostructure at high hole doping concentration. The study of ME coupling of multifunctional oxide heterostructures is definitely important to the development and performance of future spintronic devices. The results presented here regarding the interfacial magnetic transition controlled by an external electric field offer some new perspective to study the spin transport of magnetic tunnel junctions.

36 MATERIALS SCIENCE↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed control of electric power grids

A method for determining power output levels of a plurality of nodes in an electric power system includes receiving, at a first node of the plurality of nodes, voltage information and multipliers of all neighboring nodes of the first node within the electric power system, determining, by the first node, a local power generation and a local voltage using the voltage information and the multipliers of the neighboring nodes and distributing the local power generation and the local voltage to the neighboring nodes, determining, by the first node, an estimated voltage of each of the neighboring nodes and distributing the estimated voltage to each of the neighboring nodes, and updating, by the first node, a local multiplier using the voltage information received from the neighboring nodes and the estimated voltage of each of the neighboring nodes determined by the node.

Ghosh, Soumyadip↗

Power management for wireless nodes

A system includes a rectifier having an input configured to receive a variable AC input voltage and convert the AC input voltage to a rectified output voltage. A power converter has an input coupled to receive the rectified output voltage and to provide a DC supply voltage at an output thereof. A low drop-out regulator has an input coupled to receive the supply voltage and is configured provide a regulated voltage. A sensor is coupled to receive the regulated voltage as a power source and is configured to sense a condition and provide sensor data indicative of the sensed condition.

Feng, Philip X. L.↗

High-data throughput reconfigurable computing platform

A reconfigurable computing platform includes a reconfigurable computing device, electro-optical transceiver, and first voltage converter disposed on a multilayer board. The electro-optical transceiver converts an optical signal at least one of to and from an electrical signal, and the electrical signal is operatively coupled to the reconfigurable computing device. The electro-optical transceiver is disposed in proximity to the reconfigurable computing device, and the first voltage converter is operatively coupled to a common voltage distributed around a periphery of the multilayer board. The first voltage converter converts the common voltage to a first operating voltage, and the first voltage converter is disposed in proximity to the reconfigurable computing device. The first operating voltage is provided to the reconfigurable computing device as a first power source. A reconfigurable computing system includes a plurality of reconfigurable computing platforms operatively coupled together using an optical signal. A corresponding method of providing a reconfigurable computing platform is also disclosed.

Tang, Shaochun↗

Enhanced Performance of Dual Inverter with a Floating Capacitor for Motor Drive Applications

This paper studies a dual inverter supplied by a DC-link and a floating capacitor (FC), emerged as a promising inverter topology for motor drive applications. For this type of inverter, the voltage ratio between the DC-link and the FC can be actively controlled. This ratio design is crucial as it essentially defines both the DC-link voltage utilization and the inverter output quality. Several voltage ratios have previously been discussed to enhance the dual inverter performance, but only one aspect, either the voltage utilization or the output quality, is investigated. As a result, although one performance aspect can be improved, the other aspect has been adversely affected. In this work, a comparative study considering both aspects is carried out for all the possible voltage ratios. Based on this analysis, the optimal ratios for different inverter modulation indices are identified. This is followed by proposing a ratio selection strategy to double the voltage utilization without degrading the output quality. Furthermore, this strategy enables an electric drive to work at a higher maximum speed without flux weakening for a given DC-link voltage. The claimed advantages have been proved by experimental tests on an open-end windings induction motor drive.

42 ENGINEERING↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High accuracy in-situ direct gas analysis of Li-ion batteries

Cycling of lithium-ion batteries containing Ni-rich NMC cathodes at high voltage involves intense gas generation. From the safety standpoint, it is critical to understand how different gas species respond to changes of upper cut-off voltages. In this manuscript, we introduce a novel experimental set up for real-time analysis of gas generation in prismatic pouch cells. In a typical experiment, a lithium-ion pouch cell is directly connected to a quadruple mass spectrometer by glass capillary. Pressure difference helps move the generated gases to the mass spectrometer column for full analysis. The gaseous species are probed during both formation cycle and aging cycles in Li-ion pouch cells comprising NMC811 cathode and graphite anode. The gases are generated upon the creation of the solid electrolyte interphase on graphite during the first formation charge. Besides ethylene gas, C 2 H 4 , whose occurrence is related to the decomposition of ethylene carbonate, a minor solvent decomposition happened at a lower voltage is demonstrated to be associated with residue water on the electrode. For aging cycles, three upper cut-off voltages have been selected to investigate the gas evolution behavior upon charging to 4.2, 4.4 and 4.6 V. Higher upper cut-off voltages do not affect the amount of O 2 measured as a part of the generated oxygen could have reacted with electrolytes. Quite similar and low amounts of O 2 remain in the cells upon charging to the selected cut-off voltages. On the other hand, the generation of CO 2 has been found to be very sensitive to upper cut-off voltage. During similar aging cycles, 6167 nmol $g_{NMC}^{-1}$ of CO 2 is generated at 4.6 V, versus 1650 nmol $g_{NMC}^{-1}$ of CO 2 at 4.4 V, versus 91 nmol $g_{NMC}^{-1}$ of CO 2 at 4.2 V.

25 ENERGY STORAGE↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast rise breakdown in dielectric filled air gap for surge protection

Electric discharge across an air gap can be self-healing, providing a unique capability for repetitive, fast, high-voltage/current switching applications through arc conduction. Furthermore, incorporating dielectric granules in the air gap stimulates gas ionization, which lowers the breakdown voltage and narrows breakdown voltage distribution, thereby enabling engineered surge protection from multiple lightning strikes on aerospace vehicles and sensitive solid-state electronics in critical systems. This study investigates the effect of the permittivity of dielectric granules, gap filling, surface roughness, and metal work function on fast-rising, high-voltage breakdowns. In addition to the air gap width, these factors play important roles in gas ionization, field concentration, and initiation of electrical discharge and arcing. Therefore, they could potentially be used to control and narrow operational breakdown voltages for practical applications. Additionally, a modified Langevin–Debye model is developed to correlate the breakdown voltage and the permittivity of the dielectric filler. These investigations identify and highlight key underpinning mechanisms governing the gas discharge behavior across a dielectric filled air gap during voltage surge events.

42 ENGINEERING↗

Pulsed photoemission induced plasma breakdown

Abstract This article characterises the effects of cathode photoemission leading to electrical discharges in an argon gas. We perform breakdown experiments under pulsed laser illumination of a flat cathode and observe Townsend to glow discharge transitions. The breakdown process is recorded by high-speed imaging, and time-dependent voltage and current across the electrode gap are measured for different reduced electric fields and laser intensities. We employ a 0D transient discharge model to interpret the experimental measurements. The fitted values of transferred photoelectron charge are compared with calculations from a quantum model of photoemission. The breakdown voltage is found to be lower with photoemission than without. When the applied voltage is insufficient for ion-induced secondary electron emission to sustain the plasma, laser driven photoemission can still create a breakdown where a sheath (i.e. a region near the electrode surfaces consisting of positive ions and neutrals) is formed. This photoemission induced plasma persists and decays on a much longer time scale ( ∼ 10 s μ s) than the laser pulse length ( 30 ps). The effects of different applied voltages and laser energies on the breakdown voltage and current waveforms are investigated. The discharge model can accurately predict the measured breakdown voltage curves, despite the existence of discrepancy in quantitatively describing the transient discharge current and voltage waveforms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis and Characterization of Four-quadrant Switches based Commutation Cell

A four-quadrant switch (FQS) blocks either polarity voltage and controls current flow in both directions. Unlike voltage-source converters, in which two-quadrant switches operate over a narrow voltage range, four-quadrant switches are required to operate over a wide range of both voltage and current in applications such as matrix converters and current-source converters. Furthermore, matrix converters require multi-step commutation schemes compared to two-step schemes for current-bidirectional switch based voltage-source converters and voltage-bidirectional switch based current-source converters. This paper provides a generalized overview of commutation schemes used for two and four quadrant switches based two-level commutation cells, identifies comparison indices for FQS commutation schemes, and discusses the need for adaptive commutation-step times for wide voltage and current variation applications. Also, the static and dynamic characteristics of 1.2 kV rated FQS implementations utilizing commercial SiC MOSFETs from four different manufacturers and novel monolithic SiC BiDirectional Field Effect Transistor (BiDFET) have been reported.

Commutation cell, four quadrant switch, SiC Bidire↗