Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Aerodynamic shape optimization using sensitivity analysis on third-order Euler equations

Two major advancements of an aerodynamic optimization method with two design variables are described. The first is represnted by an improved flow prediction method that uses the third-order accurate discretization of the Euler equations. This method makes it possible to predict the flowfield of a perturbed shape which generates shocks and other large gradients without intermediate CFD analysis. The second advancement is the use of every surface grid point as a design variable in the aerodynamic shape optimization problem. The improved algorithm is demonstrated by optimizing the ramp shape of a scramjet-afterbody configuration for maximum axial thrust. It is concluded that the improved flow-field prediction method eliminates most of the flow analysis and a priori guessing of all possible shapes from which the optimum is to be selected.

Baysal, Oktay↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers

Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.

02 PETROLEUM↗

Automated and efficient local adaptive regression for principal component-based reduced-order modeling of turbulent reacting flows

Principal Component Analysis can be used to reduce the cost of Computational Fluid Dynamics simulations of turbulent reacting flows by reducing the dimensionality of the transported variables through projection of the thermochemical state onto a lower-dimensional manifold. However, because of the nonlinearity of the principal component source terms, nonlinear regression techniques must be utilized for the source terms in terms of the principal components. Unfortunately, widely available and utilized nonlinear regression techniques can have prohibitive computational requirements and/or accuracy that is highly dependent on user experience in ad hoc tuning of model architecture and hyperparameters. Here, in this work, a new nonlinear regression approach is proposed that is both computationally efficient and automated so does not require any user input. The approach is evaluated through a priori prediction of principal component source terms using data from a Direct Numerical Simulation of a turbulent nonpremixed n-heptane/air jet flame. In particular, the proposed framework consists of local regressions whose complexity is adapted according to the local nonlinearity of the data: local linear regression when accurate enough and local Artificial Neural Networks when nonlinear regression is required. The number of local clusters for local regression is determined automatically using the Davies-Bouldin index. In addition, Bayesian optimization is utilized for model training (i.e., to select the best architectures and hyperparameters of the nonlinear regressions in an unsupervised fashion), eliminating ad hoc hand-tuning and/or expensive grid searches. Overall, compared to a single, global neural network, the new local adaptive regression approach is shown to have comparable accuracy but 69% less training time due to the utilization of local linear regression and faster training of local neural networks.

42 ENGINEERING↗

New calculations for photosynthesis measurement systems: what’s the impact for physiologists and modelers?

Measurement of carbon dioxide (CO 2 ) and water vapor (H 2 O) exchanged by leaves has been tremendously important for advancing understanding of plant physiology. Typically, photosynthesis measurement systems estimate the concentration of CO 2 and H 2 O in air that has passed over a leaf inside a leaf chamber. Together with additional information such as flow rate, leaf area, and measurement of environmental variables, the calculations of von Caemmerer & Farquhar (1981), hereafter vCF1981, are used to estimate CO 2 and H 2 O fluxes between the leaf and atmosphere. Furthermore, the combination of the vCF1981 calculations and photosynthesis measurement systems has enabled significant advances in the understanding and model representation of leaf-level photosynthesis and respiration.

54 ENVIRONMENTAL SCIENCES↗

Cost of Fish Exclusion and Passage Technologies for Hydropower

Hydropower represents a reliable source of renewable energy and accounts for approximately 7% of the total electrical generation in the United States. Future expansion of hydropower is likely to be in the form of either smaller new stream development projects or powering existing non-powered dams. For these new projects to be successful, careful analysis of risks, costs, and uncertainty to offset reduced power production as well as ensuring the protection and safe passage of migratory fish to gain public support, will be required. Exclusion and passage are two common approaches to protect fish from entrainment and impingement at hydropower facilities. The thresholds for entrainment risk and requirements for exclusion and passage often differ depending on the species involved, the characteristics of the facility, and the goals of stakeholders. While the costs associated with environmental mitigations represent a large proportion of the total costs required for the licensing of hydropower facilities, little quantitative information is present within the literature regarding the specific costs of fish exclusion and passage. Working with FOA awardee Natel Energy, scientists at Oak Ridge National Laboratory were tasked with assessing the capital construction costs for downstream fish exclusion and passage infrastructure. This report used keyword searches of an existing environmental mitigation cost data set and manual extraction of additional cost data associated with protection, mitigation, and enhancement (PM&E) measures related to positive barrier screening and passage from regulatory licensing documents available in the Federal Energy Regulatory Commission (FERC) eLibrary. This approach yielded a total of 50 PM&E mitigation measures with estimated capital construction costs pertaining to positive barrier screens, 142 pertaining to passage studies, and 26 pertaining to passage-related studies. PM&E measures associated with positive barrier screens represented <10% of the 171 total FERC project dockets available in the data set. These data were highly skewed toward conventional relicensing projects, as <7% were associated with new stream development (NSD) projects. Results from these data indicate highly variable costs associated with fish screening, with flow-normalized costs one to two orders of magnitude higher for screening with the highest exclusion capability (≤0.09 in. spacing) compared with coarser screening (1 to 2 in.). Furthermore, estimated capital costs of passage infrastructure were positively related to the scale of the project based on installed capacity for some, but not all, types of passage. These data provide an initial baseline for estimating exclusion and passage costs for hydropower development and may help developers consider options for more fish-friendly generation technologies, though gaps remain relating to a lack of data, particularly for NSD projects. More data may still be available within the FERC eLibrary, but significant effort will be required to manually identify and extract the data for future analyses.

13 HYDRO ENERGY↗

Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

Hydropower Capacity Factor Trends & Analytics for the United States

This data repository contains all code, input data, and data generated for Turner et al. (2024)—“Hydropower capacity factors trending down in the United States”. File descriptions: – hydro-cf-trends-inputs.zip: Full set of input data used in this study, organized for direct entry into “/data” directory of hydro-cf-trends data processing pipeline. – hydro-cf-trends.zip: Full data processing pipeline, coded using the R {targets} framework. This is a snapshot release (v1.0) of the code repository stored at https://code.ornl.gov/turnersw/hydro-cf-trends/. – hydro-cf-trends-results.zip: Provides all dam level results required to reproduce results and graphics in Turner et al. (2024). Dams are identified by the “complxID” (root of the hydropower plant ID in the Existing Hydropower Assets Database, inherited from HILARRI). Results include: • dam_CF_trends.csv: Table of long-term trends in annualized capacity factors for 610 dams and modeled annualized capacity factors for 362 modeled dams (naturalized and assimilated flows). • dam_annualized_CF_gen.csv: Annualized time series of the following variables for each of 610 hydropower dams with nameplate > 5MW – Reported nameplate capacity (MW) – Implied maximum annual generation (MWh) – Reported net generation (MWh) – Computed annual capacity factor – Modeled annual capacity factor (362 modeled plants only)

13 HYDRO ENERGY↗

Outdoor flat-plate collector performance prediction from solar simulator test data

Solar collector performance data obtained from tests with a simulator was modified for real-life conditions. The data obtained with the simulator was corrected for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered outdoors. Modification of simulator data was accomplished by combining experiment with theory. The technique was demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analysis and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

Outdoor flat-plate collector performance prediction from solar simulator test data

This paper describes how collector performance obtained from test data with a simulator can be modified for real-life conditions. The approach taken is to correct the performance data obtained with the simulator for the variable conditions of ambient temperature, wind, incident angle, flow rate, etc., that are encountered in outdoor conditions. Modification of simulator data is accomplished by combining experiment with theory. The technique is demonstrated by application to a spectrally selective and a nonselective type of collector. This kind of modified simulator collector performance data should be valuable in solar systems analyses and for collector performance ranking based on all-day calculated conditions.

Simon, F. F.↗

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

Heat pipe heat rejection system

A prototype of a battery heat rejection system was developed which uses heat pipes for more efficient heat removal and for temperature control of the cells. The package consists of five thermal mock-ups of 100 amp-hr prismatic cells. Highly conductive spacers fabricated from honeycomb panels into which heat pipes are embedded transport the heat generated by the cells to the edge of the battery. From there it can be either rejected directly to a cold plate or the heat flow can be controlled by means of two variable conductance heat pipes. The thermal resistance between the interior of the cells and the directly attached cold plate was measured to be 0.08 F/Watt for the 5-cell battery. Compared to a conductive aluminum spacer of equal weight the honeycomb/heat pipe spacer has approximately one-fifth of the thermal resistance. In addition, the honeycomb/heat pipe spacer virtually eliminates temperature gradients along the cells.

Kroliczek, E. J.↗

Singularity computations

Direct descriptions of the structure of a singularity would describe the radial and angular distributions of the field quantities as explicitly as practicable along with some measure of the intensity of the singularity. This paper discusses such an approach based on recent development of numerical methods for elastoplastic flow. Attention is restricted to problems where one variable or set of variables is finite at the origin of the singularity but a second set is not.

Swedlow, J. L.↗