Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Radiative transfer effects behind reflected shock waves

Theoretical studies are reported which were largely centered on the nonequilibrium coupling of collisional, ionization, and radiative transfer processes behind reflected shock waves in nitrogen. Experimental studies included broad-band photomultiplier radiative intensity measurements, luminosity photographs of the reflected shock wave front, end-wall heat transfer measurements, and reflected shock velocity time-history measurements. The results of these activities are summarized, and comparisons between the theoretical and experimental results are discussed.

Nerem, R. M.↗

Visibility and aerosol measurement by diode-laser random-modulation CW lidar

Examples of diode laser (DL) random-modulation continuous wave (RM-CW) lidar measurements are reported. The ability of the measurement of the visibility, vertical aerosol profile, and the cloud ceiling height is demonstrated. Although the data shown here were all measured at night time, the daytime measurement is, of course, possible. For that purpose, accurate control of the laser frequency to the center frequency of a narrow band filter is required. Now a new system with a frequency control is under construction.

Takeuchi, N.↗

Automated measurement of the bit-error rate as a function of signal-to-noise ratio for microwave communications systems

The performance of microwave systems and components for digital data transmission can be characterized by a plot of the bit-error rate as a function of the signal to noise ratio (or E sub b/E sub o). Methods for the efficient automated measurement of bit-error rates and signal-to-noise ratios, developed at NASA Lewis Research Center, are described. Noise measurement considerations and time requirements for measurement accuracy, as well as computer control and data processing methods, are discussed.

Kerczewski, Robert J.↗

Phase Time and Envelope Time in Time-Distance Analysis and Acoustic Imaging

Time-distance analysis and acoustic imaging are two related techniques to probe the local properties of solar interior. In this study, we discuss the relation of phase time and envelope time between the two techniques. The location of the envelope peak of the cross correlation function in time-distance analysis is identified as the travel time of the wave packet formed by modes with the same w/l. The phase time of the cross correlation function provides information of the phase change accumulated along the wave path, including the phase change at the boundaries of the mode cavity. The acoustic signals constructed with the technique of acoustic imaging contain both phase and intensity information. The phase of constructed signals can be studied by computing the cross correlation function between time series constructed with ingoing and outgoing waves. In this study, we use the data taken with the Taiwan Oscillation Network (TON) instrument and the Michelson Doppler Imager (MDI) instrument. The analysis is carried out for the quiet Sun. We use the relation of envelope time versus distance measured in time-distance analyses to construct the acoustic signals in acoustic imaging analyses. The phase time of the cross correlation function of constructed ingoing and outgoing time series is twice the difference between the phase time and envelope time in time-distance analyses as predicted. The envelope peak of the cross correlation function between constructed ingoing and outgoing time series is located at zero time as predicted for results of one-bounce at 3 mHz for all four data sets and two-bounce at 3 mHz for two TON data sets. But it is different from zero for other cases. The cause of the deviation of the envelope peak from zero is not known.

Chou, Dean-Yi↗

The Electron Drift Technique for Measuring Electric and Magnetic Fields

The electron drift technique is based on sensing the drift of a weak beam of test electrons that is caused by electric fields and/or gradients in the magnetic field. These quantities can, by use of different electron energies, in principle be determined separately. Depending on the ratio of drift speed to magnetic field strength, the drift velocity can be determined either from the two emission directions that cause the electrons to gyrate back to detectors placed some distance from the emitting guns, or from measurements of the time of flight of the electrons. As a by-product of the time-of-flight measurements, the magnetic field strength is also determined. The paper describes strengths and weaknesses of the method as well as technical constraints.

Paschmann, G.↗

Time-Distance Helioseismology

Time-distance helioseismology is a method of ambient noise imaging using the solar oscillations. The basic realization that led to time-distance helioseismology was that the temporal cross correlation of the signals at two 'surface' (or photospheric) locations should show a feature at the time lag corresponding to the subsurface travel time between the locations. The temporal cross correlation, as a function of the location separation, is the Fourier transform of the spatio-temporal power spectrum of the solar oscillations, a commonly used function in helioseismology. It is therefore likely the characteristic ridge structure of the correlation function had been seen before without appreciation of its significance. Travel times are measured from the cross correlations. The times are sensitive to a number of important subsurface solar phenomena. These include sound speed variations, flows, and magnetic fields. There has been much interesting progress in the 17 years since the first paper on this subject (Duvall et al., Nature, 1993, 362, 430-432). This progress will be reviewed in this paper.

Duvall, Thomas L., Jr.↗

Dynamic Measurement of Temperature, Velocity, and Density in Hot Jets Using Rayleigh Scattering

A molecular Rayleigh scattering technique was utilized to measure time-resolved gas temperature, velocity, and density in unseeded gas flows at sampling rates up to 10 kHz. A high power continuous-wave (cw) laser beam was focused at a point in an air flow field and Rayleigh scattered light was collected and fiber-optically transmitted to a Fabry-Perot interferometer for spectral analysis. Photomultipler tubes operated in the photon counting mode allowed high frequency sampling of the total signal level and the circular interference pattern to provide time-resolved density, temperature, and velocity measurements. Mean and rms velocity and temperature, as well as power spectral density calculations, are presented for measurements in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at the NASA Glenn Research Center (GRC). The Rayleigh measurements are compared with particle image velocimetry data and CFD predictions. This technique is aimed at aeronautics research related to identifying noise sources in free jets, as well as applications in supersonic and hypersonic flows where measurement of flow properties, including mass flux, is required in the presence of shocks and ionization occurrence.

Mielke, Amy F.↗

Flow Visualization for Plume-Surface Interaction at Martian-Relevant Lander Environments

This paper describes a jet impingement experiment performed in a large-scale vacuum chamber at Martian-relevant ambient pressure conditions, with the motivation of studying plume-surface interaction (PSI) caused by the exhaust plume of a lander interacting with the planetary surface. Flow visualization of an inert supersonic jet was performed using planar laser-induced fluorescence (PLIF), which is a molecular-based, two-dimensional measurement technique. Representative instantaneous and time-averaged visualizations of the impinging jet at two different nozzle flow conditions corresponding to the underexpanded and overexpanded jet regimes are presented for up to six different dimensionless altitudes h/De. The time-averaged measured spatial distribution of impingement pressures at these conditions is also reported. The PLIF visualizations appear to be critical towards explaining unexpected behavior in the impingement pressure, such as a higher impingement pressure for the underexpanded condition at h/De = 10, compared to a lower altitude of h/De = 8. This behavior can be attributed to differences in the stagnation shock structure observed in the PLIF images. The PLIF images also reveal significant flow separation at the nozzle exit for the overexpanded jet conditions. Further analysis of the test data as well as combined flow visualization and surface diagnostics for future ground tests will help inform engineering designs for landings on the Martian surface while mitigating PSI risks.

PLIF↗

Flow Visualization for Plume-Surface Interaction at Martian-Relevant Lander Environments

This paper describes a jet impingement experiment performed in a large-scale vacuum chamber at Martian-relevant ambient pressure conditions, with the motivation of studying plume-surface interaction (PSI) caused by the exhaust plume of a lander interacting with the planetary surface. Flow visualization of an inert supersonic jet was performed using planar laser-induced fluorescence (PLIF), which is a molecular-based, two-dimensional measurement technique. Representative instantaneous and time-averaged visualizations of the impinging jet at two different nozzle flow conditions corresponding to the underexpanded and overexpanded jet regimes are presented for up to six different dimensionless altitudes h/De. The time-averaged measured spatial distribution of impingement pressures at these conditions is also reported. The PLIF visualizations appear to be critical towards explaining unexpected behavior in the impingement pressure, such as a higher impingement pressure for the underexpanded condition at h/De = 10, compared to a lower altitude of h/De = 8. This behavior can be attributed to differences in the stagnation shock structure observed in the PLIF images. The PLIF images also reveal significant flow separation at the nozzle exit for the overexpanded jet conditions. Further analysis of the test data as well as combined flow visualization and surface diagnostics for future ground tests will help inform engineering designs for landings on the Martian surface while mitigating PSI risks.

PLIF↗

Advances in Time-Distance Helioseismology

Time-distance helioseismology is a way to measure travel times between surface locations for waves traversing the solar interior. Coupling the travel with an extensive modeling effort has proven to be a powerful tool for measuring flows and other wave speed inhomogeneities in the solar interior. Problems receiving current attention include studying the time variation of the meridional circulation and torsional oscillation and active region emergence and evolution, current results on these topics will be presented.

Duvall, Thomas L., Jr.↗

EPCAPE-PT-LANL Measurements: Ground based counterflow virtual impactor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Ground based counter flow virtual impactor (Brechtel Inc) Data Notes: A factor of 6.7 needs to be applied to all cloud droplet residual concentration to correct the enhancement of the concentration because all the residual samples collected at 100 lpm were delivered into the 15 lpm of CVI sample flow. [https://amt.copernicus.org/articles/5/1259/2012/amt-5-1259-2012.html] Header: - Visibility[m]: The atmospheric visibility at the time of measurement, expressed in meters. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement passed quality control checks. - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage

54 ENVIRONMENTAL SCIENCES↗

Compensated time of flight telescope for spaceborne cosmic ray measurements

A large area time-of-flight telescope has been studied for future application in space-borne cosmic ray experiments. A new compensation technique for propagation delays inside the scintillators has been applied, which is operative in two perpendicular directions. This technique, superior to conventional one-dimensional compensations, allows high rejection probability for upward moving single particles at very short counter distances. Besides mechanical advantages a short counter distance is desirable because it permits a large field of view for the detector. A measurement of light transit times in scintillators is presented and based on it, directionality for shower events is discussed.

Rothermel, H.↗

Aircraft/lidar turbulence comparison

Very good agreement between remotely sensed winds using a ground-based Doppler lidar and in situ measurements with an instrumented aircraft is possible. Results show that turbulence intensities computed from time histories measured with the aircraft and time histories of the radial wind measured with lidar can be analyzed statistically to provide turbulence intensities and turbulence spectra which agree well with one another. The results further show that the second moment data, as presently compared with the NASA/MSFC algorithms, do not provide meaningful comparisons with turbulence intensities measured with the aircraft. This disagreement, however, must be investigated further in terms of the accuracy of the second moment data determined by both the lidar hardware and the algorithm for computing the second moment.

Huang, Kao-Huah↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

Time-Energy Uncertainty Relation for Noisy Quantum Metrology

Detection of very weak forces and precise measurement of time are two of the many applications of quantum metrology to science and technology. To sense an unknown physical parameter, one prepares an initial state of a probe system, allows the probe to evolve as governed by a Hamiltonian 𝐻 for some time 𝑡, and then measures the probe. If 𝐻 is known, we can estimate 𝑡 by this method; if 𝑡 is known, we can estimate classical parameters on which 𝐻 depends. The accuracy of a quantum sensor can be limited by either intrinsic quantum noise or by noise arising from the interactions of the probe with its environment. In this work, we introduce and study a fundamental trade-off, which relates the amount by which noise reduces the accuracy of a quantum clock to the amount of information about the energy of the clock that leaks to the environment. Specifically, we consider an idealized scenario in which a party Alice prepares an initial pure state of the clock, allows the clock to evolve for a time that is not precisely known, and then transmits the clock through a noisy channel to a party Bob. Meanwhile, the environment (Eve) receives any information about the clock that is lost during transmission. We prove that Bob’s loss of quantum Fisher information about the elapsed time is equal to Eve’s gain of quantum Fisher information about a complementary energy parameter. We also prove a similar, but more general, trade-off that applies when Bob and Eve wish to estimate the values of parameters associated with two noncommuting observables. We derive the necessary and sufficient conditions for the accuracy of the clock to be unaffected by the noise, which form a subset of the Knill-Laflamme error-correction conditions. A state and its local time-evolution direction, if they satisfy these conditions, are said to form a metrological code. We provide a scheme to construct metrological codes in the stabilizer formalism. We show that there are metrological codes that cannot be written as a quantum error-correcting code with similar distance in which the Hamiltonian acts as a logical operator, potentially offering new schemes for constructing states that do not lose any sensitivity upon application of a noisy channel. We discuss applications of the trade-off relation to sensing using a quantum many-body probe subject to erasure or amplitude-damping noise.

metrology↗

Applications of Kalman filtering to real-time trace gas concentration measurements

A Kalman filtering technique is applied to the simultaneous detection of NH3 and CO2 with a diode-laser-based sensor operating at 1.53 micrometers. This technique is developed for improving the sensitivity and precision of trace gas concentration levels based on direct overtone laser absorption spectroscopy in the presence of various sensor noise sources. Filter performance is demonstrated to be adaptive to real-time noise and data statistics. Additionally, filter operation is successfully performed with dynamic ranges differing by three orders of magnitude. Details of Kalman filter theory applied to the acquired spectroscopic data are discussed. The effectiveness of this technique is evaluated by performing NH3 and CO2 concentration measurements and utilizing it to monitor varying ammonia and carbon dioxide levels in a bioreactor for water reprocessing, located at the NASA-Johnson Space Center. Results indicate a sensitivity enhancement of six times, in terms of improved minimum detectable absorption by the gas sensor.

Non-NASA Center↗